HPE 698529-B21 Getting Started Guide

QuickSpecs
HPE Smart Array P430 Controller
Overview
Page 1
HPE Smart Array P430 Controller
The HPE Smart Array P430 Controller is a low profile, PCIe3 x8, 12Gb/s capable Serial Attached SCSI (SAS) RAID controller that provides enterprise class storage performance and data protection for select features eight internal physical links and delivers increased server uptime by providing advanced storage functionality, incl online RAID level migration (between any RAID levels) with flash back write cache, global online Data compatibility between HPE Smart Array Controllers means customers can easily upgrade to future Smart Array Controllers.
What's New
HPE Smart Array P430 controller with 4GB Flash Backed Write Cache kit with battery
Models
HPE Smart Array P430
HPE Smart Array P430/2GB FBWC 12Gb 1-port Int SAS Controller
698529-B21
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
HPE ProLiant Gen8 rack and tower servers. It
uding
spare, and pre-failure warning.
HPE Secure Encryption is supported on P430 as an option
12Gb/s SAS performance when used on a DL580 Gen8 with 12Gb/s devices (SSDs or HDDs)
Controller
QuickSpecs
HPE Smart Array P430 Controller
Standard Features
Page 2
The Smart Array Advantage
HPE's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much low The HPE Smart Array family brings an unparalleled return on investment through:
Data Compatibility among most current shipping Smart Array controllers allows simple and easy upgrades any time as needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers.
Consistent Configuration and Management Tools. Most current shipping Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HPE server storage.
SmartDrive Carrier form factor is used across multiple Hewlett Packard Enterprise servers. With compatibility across many enterprise platforms, you are free to deploy and re quickly deliver increased storage capacity, migrat drives.
Pre-Failure Warranty means HPE Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the Support Center or refer to your
Key Features
The SA-P430 Controller supports up to 27 drives depending on the server implementation.
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
er Total Cost of Ownership (TCO) than any other server storage RAID product.
-deploy these drives to
e data between systems, and easily manage spare
HPE Server documentation.
Seamless upgrades from past generations and upgrades to next generation HPE high
performance and high capacity Serial Attached SCSI Smart Array controllers.
12Gb/s SAS performance when used on a DL580 Gen8 with 12Gb/s devices (SSDs or HDDs)
6Gb/s SAS technology delivers high performance and data bandwidth and contains full
compatibility with 6Gb/s SATA technology.
PCI Express Gen3 x8 link width delivers high performance and data bandwidth up to 8 GT/s
theoretical maximum bandwidth
2 or 4 GiBytes Flash Backed Write Cache (FBWC) provides read ahead caching and write back
caching with indefinite write cache data retention in the case of unexpected power outage
Standard on the P430 are RAID 6 ADG, RAID 60 ADG, RAID 1 ADM, Capacity Expansion,
mirror split, recombine, and rollback in Online Mode, Drive Erase, Performance Optimization­Degraded Reads and Read Coalescing, Move/Delete any individual LUNS and Online Split Mirror.
Capable of supporting both legacy and UEFI boot operation on a DL580 Gen8 server
The HPE SSD Smart Path feature included in the Smart Array software stack improves SSD
read for all RAID levels and RAID 0 write operations by optimizing the path to each SSD attached to the controller
The HPE SmartCache feature (HPE Smart Cache license is required on P430) is a controller-
based read caching solution in a DAS environment that caches the most frequently accessed data ("hot" data) onto lower latency SSDs to dynamically accelerate application workloads.
The HPE Secure Encryption, available as an option, is a Smart Array controller-based data
encryption solution for ProLiant Gen 8 servers that protect sensitive, mission critical data.
Mix-and-match SAS and SATA hard drives lets you deploy drive technology as needed to fit
your computing environment.
Software consistency on most current shipping Smart Array products: HPE Smart Storage
Administrator, HPE Systems Insight Manager (SIM), and HPE Intelligent Provisioning. The HPE Smart Storage Administrator configures and manages a host of Smart Array Controllers and other storage devices using a single interface. It replaces the HPE Array Configuration Utility (ACU) with an updated design and configuration enhancements.
Low-profile PCI Express form factor - ships with a full size and a low profile bracket for
deployment flexibility based on slot availability.
HPE
QuickSpecs
HPE Smart Array P430 Controller
Standard Features
Page 3
Management Features
Online array expansion
Ports
Eight (8) SAS physical links on 1 internal x8 Mini-SAS double-wide connector
Performance
12Gb/s SAS (1200 MB/s theoretical bandwidth per physical lane) on a DL580 Gen8
Availability
Provides increased server uptime by providing advanced storage functionality:
Fault Prevention
The following features offer detection of possible failures before they occur, allowing preventive action to be taken:
Fault Tolerance
Keeps data available and server running while a failed drive is being replaced; several fault tolerance
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
Online capacity expansion
Online logical drive extension
Online RAID level migration
Online stripe size migration
Online mirror split, recombine and rollback
Online and high performance offline Rapid Parity Initialization (RPI)
Unlimited global online spare assignment
User selectable expand and rebuild priority
User selectable RAID level and stripe size
User selectable read and write cache sizes
Supports Predictive Spare Activation
6Gb/s SAS (600MB/s theoretical bandwidth per physical lane)
x8 6Gb/s SAS physical lane (compatible with 6Gb/s SATA )
2 GiBytes 72-bit wide DDR3-1600MHz Flash Back Write Cache provides up to 12.8GB/s
maximum cache bandwidth or 4 GiBytes 72-bit wide DDR3-1866 Flash Back Write Cache provides up to 14.9GB/s maximum cache bandwidth
PCI Express Gen3 x8 link width
Read ahead caching
Write-back caching
Online RAID level migration between any RAID levels
Online stripe size migration
Online capacity expansion
Online logical drive extension
Online active drive replacement
Online drive firmware upgrade
Unlimited global online spare
Pre-Failure Warranty
S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HPE detects
possible hard disk failure before it occurs, allowing replacement of the hard drive before a real failure occurs.
Drive Parameter Tracking monitors drive operational parameters, predicting failure and
notifying the administrator.
Dynamic Sector Repairing continually performs background surface scans on the hard disk
drives during inactive periods and automatically remaps bad sectors, ensuring data integrity.
Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure
preventative maintenance.
QuickSpecs
HPE Smart Array P430 Controller
Standard Features
Page 4
configurations are supported including:
(Distributed Data Guarding): Supported with a minimum of 3 drives. This allocates one
re without
Fault Recovery
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure
Ease of Use
Consistency and upgradeability on most current shipping Smart Array products make them unique in the industry:
HPE SSD Smart Path
The HPE SSD Smart Path feature included in the Smart Array software stack improves Solid State Disk (SSD) read performance. With up to 4x better SSD read performance,
s the optimum path to the SSD and accelerates reads for all RAID levels and RAID 0 writes. Path requires updated firmware, drivers, and configuration utility available at:
http://www.hp.com/go/hpssa
included as a base feature on are supported by the
Microsoft Windows Server 2008 R2
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
RAID 6 (Advanced Data Guarding): Supported with a minimum of 4 drives. This allocates two
sets of parity data across drives. This level of fault tolerance can withstand a double drive failure without downtime or data loss.
RAID 60: Supported with a minimum of 8 drives. This volume is composed of two or more
RAID 6 sub-volumes (parity groups) where data is striped across each parity group as if it were a single physical drive. Each RAID 6 parity group can sustain up to two drive failures without incurring data loss.
RAID 5
set of parity data across drives. This level of fault tolerance can withstand a single drive failure without downtime or data loss.
RAID 50: Supported with a minimum of 6 drives. This volume is composed of two or more
RAID 5 sub-volumes (parity groups) where data is striped across each parity group as if it were a single physical drive. Each RAID 5 parity group can sustain a single drive failu incurring data loss.
RAID 1 & 10 (Drive Mirroring): Supported with a minimum of 2 drives. This allocates half of
the drive array to the data and the other half to the mirrored data, providing two copies of the data.
RAID 1 ADM & 10 ADM (Advanced Data Mirroring): Supported with a minimum of 3 drives.
RAID 1 ADM creates redundant copies of the data using 3 drives. RAID 10 ADM stripes data across two or more sets of RAID 1 ADM volumes. This level of fault tolerance can withstand a double drive failure within a RAID 1 ADM volume without downtime or data loss.
Recovery ROM: This feature protects the user from a firmware image corruption by storing a
redundant copy of the firmware image. If the active firmware image becomes corrupt, the controller will use the redundant firmware image and continue operating.
On-Line Spares: There is no limit to the number of spare drives that can be installed prior to
drive failure. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically.
DRAM ECC detects and corrects data bit errors
GUI based configuration, management and diagnostic software tools with the HPE Smart
Storage Administrator
Common data format between generations of products
Data migration between servers and external Modular Smart Array enclosures and Disk
Enclosures
. HPE SSD Smart Path is ideal for read intensive workloads and is
HPE Smart Array P-series controllers. The following operating systems
HPE SSD Smart Path feature:" Microsoft Windows Server 2008
HPE SSD Smart Path choose
HPE SSD Smart
QuickSpecs
HPE Smart Array P430 Controller
Standard Features
Page 5
Microsoft Windows Server 2012
HPE SmartCache
The HPE SmartCache feature is a controller-based read caching solution in a DAS environment that caches the most frequently accessed data ("hot" data) onto lower latency SSDs to dynamically accelerate application workloads. The ProLiant Gen8 supported HDD for bulk storage and any accelerator.
HPE
The basic
: The final element is metadata, information held in the FBWC that maps the location
For more information please visit:
HPE Secure Encryption
HPE Secure Encryption is a Smart Array controller-based data encryption solution for ProLiant Gen 8 servers that protects sensitive, mission critical data. This is an enterprise data at rest on any bulk storage attached (with the exception of tape or external arrays such as P2000 and MSA 2040) to the supported cache memory of the controller.
The solution Management Mode is focused on single server deployment where there is one Master key per controller that is managed by the user. All volumes still have their own unique key( encryption. Remote Key Management Mode is for enterprise wide deployments and requires Integrated Lights Out (iLO) Advanced or Scale Out editions v 1.40 or later and Key Manager (ESKM) 3.1 or any later release. The
ESKM manages all the encryption deployments
from just a few servers to thousands of servers and 2 million keys per
For more information please visit http://www.hp.com/go/hpsecureencryption
Warranty
The warranty for this device is 3-years parts only.
Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre Support Center or refer to your
Warranty Upgrade Options
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
Red Hat Enterprise Linux 6.1, 6.2, 6.3, 6.4, and 6.5
SUSE Linux Enterprise Server 11 (SP1, SP2, SPA)
VMware ESXi 5.0 U3
VMware vSphere 5.1 U2 and vSphere 5.5
HPE SmartCache architecture is flexible and supports any HPE
HPE ProLiant Gen8 supported SSD as an
SmartCache is deployed and managed using the HPE SmartStorage Administrator (HPE SSA).
HPE SmartCache architecture is comprised of the following three elements:
Bulk storage: The first element is the bulk storage device, which is any supported HDD
attached to the HPE Smart Array controller.
Accelerator: The second element, the accelerator, is a faster/lower latency SSD device that
caches data.
Metadata
of information residing on the accelerator and bulk storage devices.
http://www.hp.com/go/smartcache
HPE Smart Array Px3x family of controllers including data on the
is available for both local and remote key management mode deployments. Local Key
HPE
-Failure (replacement) Warranty. For complete details, consult the HPE
HPE Server Documentation.
Response - Upgrade on-site response from next business day to same day 4 hours
Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
Duration - Select duration of coverage for a period of 1, 3, or 5 years
Warranty upgrade options can come in the form of Care Packs, which are sold at the HPE
System level to which this product attaches.
-class encryption solution for
s) for data
HPE
HPE Enterprise Secure
HPE ESKM 3.1 cluster.
Loading...
+ 10 hidden pages