A HPE BladeSystem solutions start with an either a c7000 or c3000 enclosure. For the c3000 enclosure, key
enclosure components include hot
redundant BladeSystem Onboard Administrator module. Once the enclosure and its key components have
been selected
server blades, expansion blades, and optional
NOTE:
server blades, subject to support requirements of the Onboard Administrator. Certain
blades and options may require a specific version of the Onboard Administrator firmware. This firmware
release may a
Service Pack for ProLiant (SPP) website
Blades
A BladeSystem c3000
total blades) plus redundant network and storage interconnects. It includes a shared, multi
midplane for wire
a pooled power backplane that en
Each c3000 enclosure is built with the following functions:
height server blades, and expansion
blades, please see the section titled "Server Blade, Expansion Blade, and Fan Population Guidelines"
An Onboard Administrator management module is built in to the enclosure with the following functions:
A BladeSystem c3000 enclosure provides the following benefits:
-Class c3000
-plug power supplies, hot-plug HPE Active Cool 100 Fans, and an optional
, the following components can be added: interconnect modules, HPE ProLiant and Integrity
HPE Insight Control for BladeSystem management software.
HPE BladeSystem c3000 and c7000 Enclosures support G1 through Gen10 ProLiant and Integrity
lso require other subsystem firmware upgrades. For further information, please see the HPE
and the HPE Support Center document “HPE ProLiant Server
- Compatibility with HPE BladeSystem c7000 and c3000 Enclosures and Firmware”.
Enclosure holds up to 8 server blades and up to 4 expansion blades (not exceeding 8
• Up to 8 half-height server blades, 4 full-height server blades, and/or 4 expansion blades per enclosure
(not exceeding 8 total blades).
NOTE: For information on mixing half-height server blades, full-
-once connectivity of server blades to network and shared storage. Power is delivered through
sures the full capacity of the power supplies is available to all blades.
later in this document.
• Up to 2 redundant I/O interconnect fabrics (Ethernet, Fibre Channel, iSCSI, SAS, etc.) supported
simultaneously within the enclosure.
• A single-phase power subsystem for flexibility in connecting to datacenter power, UPSs, or low-line
(100VAC to 110VAC) wall outlets.
CAUTION: when connecting directly to wall outlets, customers should determine the maximum
amperage of the wall outlet circuit to prevent power overload.
• Choice of AC power supplies.
• PARSEC enclosure design - Parallel, redundant and scalable cooling and airflow design.
• Up to six (6) hot-plug HPE Active Cool 100 Fans.
interconnect modules, and optional redundant BladeSystem Onboard Administrator management
module.
HPE ProLiant server
-terabit high-speed
• Robust, multiple enclosure setup and control.
• Reports asset and inventory information for the devices in the enclosure.
• Reports thermal and power information, including real-time actual power usage per server and per
enclosure.
• Front-mounted Insight Display for easy management at the deployment site.
• Integrated access to all server blade iLOs from a single cable.
• Provides integrated access to interconnect bay device management ports from the single Onboard
Administrator cable.
• Single sign-on capability for all devices in the enclosure.
• Role-based security locally and/or with LDAP directory services.
• Provides a wizard-based initial setup process for easy configuration.
• An optional DVD drive for local software deployment, and HPE SmartStart deployment
• An optional local KVM interface for connection to KVM switches.
Page
QuickSpecs
HPE BladeSystem c3000 Enclosure
Standard Features
Page 3
• With local and remote hardware management integrated across the solution, one full enclosure can be
HPE ProLiant &
Integrity Server
Blades
Delivering best-in-class performance, choice and reliability on AMD Opteron™, Intel® Xeon® and Intel® Itanium®
processors for Windows, Linux, Solaris, OpenVMS, or
supports a variety of application requirements for scale
one
information please visit:
HPE D2200sb
Storage Blade
Direct attached storage
The D2220sb Storage Blade delivers direct attached storage for c
support for up to twelve hot plug small form factor (SFF) SAS or SATA Midline hard disk drives or SAS/SATA
SSDs. The enclosure backplane provides a PCI Express connection to an adjacent c
enables high performance
an onboard Smart Array P420i controller with 2GB flash
data protection. Up to four D2220sb storage devices can be supported
Enclosure for up to 57.6 TB of capacity.
Tape blades are ideal for HPE BladeSystem c-Class customers who need a data protection solution but are not
connected into a storage area network (SAN). They provide direct attach data protection for the adjacent
server and network backup protection for all other data within the enclo
industry's first bladed tape drives and are developed exclusively for the BladeSystem c
For more information, please visit:
h
HPE BladeSystem
c
Interconnect
Options
Hewlett Packard Enterprise offers one of the broadest selections of interconnect fabric options in the industry
to provide network, SAN/network at
interconnects provide:
• Management and network interconnects extend scalability beyond a single enclosure, allowing
resources to be pooled and shared across multiple enclosures.
• Accommodates multiple server and network designs in one enclosure.
• Lower costs per server in comparison to rack-mounted servers
• Lower power consumption in comparison to rack-mounted servers.
• Reduced and simplified cabling in comparison to rack-mounted servers.
• Investment protection supporting G1 through Gen10 server blades.
HP-UX based servers; the HPE portfolio of server blades
-, two-, four- and eight -processor server blades, with the widest range of performance, and form factors. For
https://www.hpe.com/us/en/integrated-systems/bladesystem.html .
tached storage (NAS), and cluster connectivity. HPE BladeSystem
• HPE Virtual Connect devices, designed to reduce networking costs and simplify network configuration
and provisioning.
• Seamless integration of Ethernet, FC, iSCSI, and SAS fabrics: Standard-based switch options include
Cisco, Brocade, and Hewlett Packard Enterprise products that integrate within your existing standards.
• Built-in redundancy: rear-mounting interconnect modules designed for redundant interconnections
between server blades and switches.
• Cable reduction: Interconnect switches provide up to 32-to-1 network cable reductions per server
blade enclosure
BladeSystem c-Class Interconnect and Mezzanine Components:
-Class server blade and
-Class enclosures.
QuickSpecs
HPE BladeSystem c3000 Enclosure
Standard Features
Page 4
Factory Express
Portfolio for
Servers and
Storage
HPE Factory Express offers configuration, customization, integration and deployment services for Hewlett
Packard Enterprise servers
tested, integrated, shipped and deployed.
Factory Express offers service packages for simple conf
and design services as well as individual factory services, such as image loading, asset tagging and custom
packaging.
servers and storage:
HPE
switches.
For more informa
representative or go to:
HPE Simple
Configurator
One Config Simple (OCS) is a guided self-service tool to help sales and non-technical people provide customers
with initial configurations in 3 to 5 minutes. You may then send the configuration on for configuration help, or
use in your existing ordering processes. If you require "custom" rack configuration or configuration for products
not
assistance.
HPE Insight
Insight Management
Managing the growing number of servers can be complex and expensive for your
organization. IT managers need to address changing business needs with tools that
meet the challenges of managing today's complex D
HPE
providing you with best
HPE
Environment. Insight Management increases your productivity and reduces your
operating costs to get you higher value from your
Electronic download of Insight Management Media
Insight Management software media is ava
license entitlement certificates) at this
website:
Software media available for download includes:
Customers will receive an Insight Control or Matrix Operating Environment license
entitlement certificate via physical shipment or email. The license
entitlement certificate must be redeemed online or via fax in order to
obtai
One year of 24x7 Software Technical Support and Updates are included with your
purchased licenses.
Hewlett Packard Enterprise provides
services to
infrastructure. For more information about support services and licensing
options, see the following website:
and storage products. Customers can choose how their factory solutions are built,
Hewlett Packard Enterprise products supported through Factory Express include: a wide array of
Insight Management lowers the cost of running your HPE ProLiant servers by
-in-class management tools, including HPE Insight Control,
Virtual Connect Enterprise Manager (VCEM), and HPE Matrix Operating
atacenters.
HPE ProLiant servers.
ilable for free download (not including
http://www.hpe.com/info/servermanagement
• HPE Insight Control
• HPE Insight Control for Microsoft® System Center
• HPE Insight Control for VMware vCenter Server
• HPE Virtual Connect Enterprise Manager (VCEM)
• HPE Matrix Operating Environment
n the license activation key(s).
a complete range of installation and support
ensure the successful deployment and operations of your server
http://www.hpe.com/info/servermanagement
QuickSpecs
HPE BladeSystem c3000 Enclosure
Standard Features
Page 5
Insight Software Media Kit (DVDs)
Physical media (DVDs) are also available for purchase from
Enterprise
Service Pack for
ProLiant (SPP)
Customers should use the HPE Service Pack for ProLiant
and related utilities:
HPE Integrated LightsOut (iLO)
HPE Integrated Lights-Out (iLO) simplifies server setup, health monitoring, power and
thermal control, and lights
servers.
location via a web browser.
Manager, Insight Control and Insight Dynamics for ProLiant, helping customers unleash
the value of the P
For more information, visit:
HPE Insight Control
HPE Insight Control, a product option, delivers essential infrastructure management
that can help save time and money by making it easy to deploy, migrate, monitor,
remote control, and optimize your IT infrastructure through a single, simple
management consol
see
HPE
Update Service ensuring rapid access to
proactive delivery of software updates. For more information about this service, please
visit:
HPE Matrix Operating
Environment
The HPE Matrix Operating Environment (Matrix OE) for ProLiant and Integrity servers
is an integrated comma
demands. This advanced infrastructure management software lets you reduce the cost
of common data center tasks by up to 40 percent while keeping pace with your
changing business.
The
management capabilities for
cloud and Infrastructure as a Service (IaaS).
For more information, see
HPE Power
The HPE Power Advisor is a tool provided by Hewlett Packard Enterprise to assist in the estimation of power
consumption and proper selection of components including power supplies at a system, rack, and multi
level. A variety of additional features are also provided including a condensed bill of materials, a cost of own
ship calculator, and a power report. The
products in a single environment.
Hewlett Packard Enterprise
power su
maximum system power ratings for facilities planning purposes.
HPE
Warranty
Warranty - This product is covered by a global limited warranty and supported by HPE Services and a
worldwide network of
and repair is available for three years from date of purchase. Support for software and initial setup is available
Hewlett Packard
or from your authorized reseller (PN 436222-B21)
to update firmware, drivers,
https://www.hpe.com/servers/spp/
-out remote administration of ProLiant ML, DL, and BL
HPE iLO functions without additional software and can be accessed from any
HPE iLO works hand-in-hand with HPE Systems Insight
roLiant platform and deliver the highest possible quality of IT service.
http://www.hpe.com/info/ilo
e. For more information,
http://www.hpe.com/info/servermanagement
Insight Control includes one year of 24 x 7 HPE Software Technical Support and
Hewlett Packard Enterprise support staff and
http://www.hpe.com/info/servermanagement
nd center that helps you instantly adjust to dynamic business
HPE Matrix OE includes the automated provisioning, optimization, and recovery
HPE CloudSystem Matrix, the ideal platform for private
http://www.hpe.com/info/matrixoe.
Advisor
HPE Power Advisor allows for the mixing of rack, blade, and other
highly recommends using the HPE Power Advisor tool to ensure the number of
pply options you have selected can fully support your BladeSystem configuration and to review
Power Advisor is available at: http://www.hpe.com/info/hppoweradvisor
Hewlett Packard Enterprise Authorized Channel Partners. Hardware diagnostic support
-rack
er
QuickSpecs
HPE BladeSystem c3000 Enclosure
Standard Features
Page 6
for 90 days from date of purchase. Additional support may be covered under the warranty or available for an
additional fee. Enhancements to warranty services are available through
customized service agreements.
Hard drives have either a one year or three year warranty; refer to specific hard drive QuickSpecs for details.
HPE Pointnext operational services or
• Enclosure: Three-year parts and labor, on-site limited global warranty. Certain restrictions and
exclusions apply
• Enclosure options: Fans, Power Supplies, BladeSystem Onboard Administrator, 1 Year parts only or
enclosure warranty
• HPE BladeSystem Interconnects: 1 Year parts and labor, on-site regardless of the warranty period for
the system in which they are installed
• HPE Storage Fibre Channel switches have a maximum warranty period of one (1) year regardless of
the warranty period for the system in which they are installed
QuickSpecs
HPE BladeSystem c3000 Enclosure
Service and Support
7
Service and
Support
HPE Technology Services for Industry Standard Servers and BladeSystem
Capitalizing on
understands your increasingly complex bu
up with the people who know
experienced professionals at
Protect your business beyond warranty with
HPE Pointnext operational services offer complete care and support expertise with committed response choices
designed to meet your IT and business needs.
HPE
and software. You can choose the type and level of service that is most suitable for your IT and business needs.
HPE
advanced technical response.
unique customer business needs.
Choose recommended services for your c3000 BladeSystem enclosure or contact your
Enterprise
services
Recommended HPE Pointnext operational services for your HPE product
Optimized Care
3-Year HPE 6 hour Call to Repair Response, Proactive Care
Combined reactive and proactive support for hardware and software helping optimize your systems and
delivering high levels of availability through proactive service management and advanced technical response.
Hardware problem resolution to return the hardware in operating condition within 6 hours of the initial service
request. A Technical Account Manager, as your single point of contact, will own your call or issue end to end
until resolved.
HPE
Provides for hardware installation (c
Interconnects and Virtual Connect) and software installation and startup of a BladeSystem c3000 Infrastructure
in a single enclosure including deployment of OS on all blades or deployment of OS (two blades) and
Insight Control, plus Server Deployment (formerly RDP).
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0
HPE
Provides for the configuration and testing of BladeSystem Ethernet interconnect switche
to facilitate proper implementation of network protocols and access to advanced features.
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0
Standard Care
3-Year HPE 24x7 4 hour response, Proactive Care Service
This service gives you combined reactive and proactive support including rapid access to our Advanced
Solution Center to manage and prevent problems and a Technical Support Specialist with a bro
technical knowledge that will engage with additional technical expertise as needed from
Enterprise
HPE
P
Interconnects and Virtual Connect) and software installation and startup of a BladeSystem c3000 Infrastructure
in a single enclosure including deploym
Insight Control, plus Server Deployment (formerly RDP).
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0-5964enw.pdf
HPE ProLiant server and HPE BladeSystem capabilities requires a service partner who
siness technology environment. That's why it makes sense to team
Hewlett Packard Enterprise infrastructure hardware and software best - the
HPE Services.
HPE Pointnext operational services
Foundation Care services offer scalable reactive support-packages for Hewlett Packard Enterprise servers
Proactive Care delivers high levels of system availability through proactive service management and
HPE Datacenter Care provides highly flexible environmental support to address
Hewlett Packard
sales representative or authorized HPE ServiceOne partner for additional HPE Pointnext operational
information
Installation and Startup Service for HPE BladeSystem c-Class Infrastructure for c3000 enclosure
-Class ProLiant and Integrity server blades, storage blades, Ethernet
-5964enw.pdf
Installation and Startup Service for HPE BladeSystem c-Class Enhanced Network
vast global resources.
Installation and Startup Service for HPE BladeSystem c-Class Infrastructure for c3000 enclosure
rovides for hardware installation (c-Class ProLiant and Integrity server blades, storage blades, Ethernet
ent of OS on all blades or deployment of OS on two blades and HPE
-5969enw.pdf
HPE
s and Virtual Connect
ad level of
the Hewlett Packard
Page
QuickSpecs
HPE BladeSystem c3000 Enclosure
Service and Support
Page 8
HPE
Hewlett Packard Enterprise provides
switches to facilitate proper implementation of network protocols
https://www.hpe.com/h20195/v2/getpdf.aspx/4aa0
Related Services
HPE Proactive Care Personalized Support - Environmental Option
The Pe
from across the industry plus extra technical skills to your IT team. This option is only available as an add
HPE
HPE
Provides a flexible way to purchase
Proactive Select Service Credits when you purchase your hardware and then use the credits over the next 12
months.
Additional
https://www.hpe.com/us/en/services/it
Insight Online /
Insight Remote
Support
HPE Insight Remote Support provides 24 X 7 remote monitoring, proactive notifications, and problem
resolution. This comes at no additional cost with your
(
(
NOTE:
BladeSystem enclosure must be at the same service level.
HPE Support
Center
Personalized online support portal with access to information, tools and experts to support Hewlett Packard
Enterprise business products
collaborate with peers. Learn more
The HPE Support
live support. Now, you can get access to personalized IT support anywhere, anytime.
HPE
Packard Enterprise
agreement
NOTE:
Parts and
Materials
Hewlett Packard Enterprise will provide HPE-supported replacement parts and materials necessary to maintain
the covered hardware product in operating condition, including parts and materials for available and
recommended engineering improvements.
Parts and components that have reached their maximum supported lifetime and/or the maximum usage
limitations as set forth in the manufacturer's operating manual, product quick
data sheet will not be provided, repaired, or replaced as part of these services.
The defective media retention service feature option applies o
by Hewlett Packard Enterprise due to malfunction.
For more
information
To learn more on HPE ProLiant servers and HPE BladeSystem servers, please contact your Hewlett Packard
Enterprise sales
visit: https://www.hpe.com/us/en/integrated-systems/bladesystem.html
Installation and Startup Service for HPE BladeSystem c-Class Enhanced Network
for the configuration and testing of BladeSystem Ethernet interconnect
and access to advanced features.
-5964enw.pdf
rsonalized Support option provides an assigned Account Support Manager who can bring best practices
-on to
Proactive Care Support.
Proactive Select Service
HPE best-in-class consultancy and technical services. You can buy
Insight Remote Support is a prerequisite for Proactive Care. All blades within a single HPE
. Submit support cases online, chat with HPE experts, access support resources or
https://www.hpe.com/us/en/support.html
Center Mobile App allows you to resolve issues yourself or quickly connect to an agent for
Insight Remote Support and HPE Support Center are available at no additional cost with a Hewlett
warranty, HPE Pointnext operational or Hewlett Packard Enterprise contractual support
.
HPE Support Center Mobile App is subject to local availability.
-specs, or the technical product
representative or Hewlett Packard Enterprise Authorized ServiceOne partner. Or
nly to Disk or eligible SSD/Flash Drives replaced
QuickSpecs
HPE BladeSystem c3000 Enclosure
Configuration Information Factory Integrated Models
9
HPE Recommended Options have the best performance, value and availability.
Recommended
workloads and market segments.
provide the best fit
Extended Options
requiring the utmost in performance or value.
Options represent great value and performance
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations
are ordered,
Integrated Model product offerings and requirements.
For a configuration of the HPE BladeSystem, please do the following:
Step 1: Select desired model, configuration, and quantity of HPE ProLiant server and expansion
blades per enclosure (required)
NOTE: Each HPE BladeSystem c-Class Server Blade Enclosure holds up to 8 half-height server blades, 4 full-height server
blades, and/or 4 expansion blades per enclosure (not exceeding 8 tota
NOTE:
to support requirements of the Onboard Administrator.
version of the Onboard Administrator firmware. This firmware release may also require other subsystem firmware upgrades. For
further information, please see the
ProLiant Server Blades - Compatibility with HPE BladeSystem c7000 and c3000 Enclosures and Firmware”.
NOTE: For server and expansion blade (storage, tape, and PCI Expansion) information, please visit:
https://www.hpe.com/us/en/integrated
Step 2: Determine the HPE BladeSystem c3000 Enclosure(s) and choose required options
(One of the following from each list unless otherwise noted)
Select the base server blade enclosure configuration
HPE BladeSystem
c3000 c
Server Blade
Enclosures
HPE BladeSystem c3000 c-Class Server Blade Enclosures - Recommended
NOTE: The enclosures listed below include 6 HPE Active Cool 100 Fans, a DVD drive, rack rails, and a single
DDR2 Onboard Administrator module.
NOTE:
NOTE:
fan, power, and redundant OA module blanking panels) as required per the ordered configuration. If t
configuration is modified at a later date, additional blanking panels (ordered separately) may be required.
NOTE:
configurations, subject to support requirem
suggested for configurations primarily used with Integrity blades.
HPE BLc3000 Platinum Configure-to-order Enclosure with 6 Fans ROHS Trial Insight
Control License (Recommended)
696910-B21
HPE Integrity BLc3000 CTO Enclosure (Recommended)
AH257C
Options have been selected by Hewlett Packard Enterprise experts to provide the right technology for a range of
Fully integrated into the ProLiant management and security experience, Recommended Options
with timely availability. View the list for your region.
provide an extended catalog of products tailored for customers in specific markets or with specific workloads,
Fully integrated into the ProLiant management and security experience, Extended
but typically have a longer lead-time.
Hewlett Packard Enterprise recommends contacting your local sales representative for information on Factory
l blades).
HPE BladeSystem c3000 and c7000 Enclosures support G1 through Gen10 ProLiant and Integrity server blades, subject
Certain HPE ProLiant server blades and options may require a specific
-Class
HPE Service Pack for ProLiant (SPP) website and the HPE Support Center document “HPE
-systems/bladesystem.html
The power supply kits, power cables, interconnects, etc. are added per the steps below.
The enclosures listed below include the required blanking panels (device bay, interconnect module,
he
All c-Class enclosures support HPE ProLiant, Integrity and blades in either mixed or homogenous
ents of the Onboard Administrator. The AH257C enclosure is
Page
QuickSpecs
HPE BladeSystem c3000 Enclosure
Configuration Information Factory Integrated Models
Page 10
Select the type and quantity of power supply kits
HPE c3000
Enclosure Power
Supplies
HPE c3000 Enclosure Power Supplies - Recommended
NOTE: Each enclosure must include only one type of power supply. Mixing of power
supplies is not supported, except during hot swaps to different level or higher efficient
power supplies. The Onboard Administrator will exhibit a mismatch error due to mixed
power
NOTE:
B21 meets the
80 PLUS Platinum power 94% efficiency requirement. The 80 PLUS program is a unique
forum that unites electric utilities, the com
bring energy efficient technology solutions to the marketplace. 80 PLUS independently
tests power supply efficiency and publically posts the results on 80Plus.org.
NOTE:
of power supply options you have selected can fully support your BladeSystem
configuration and t
purposes. HPE Power Advisor is available at:
.
NOTE:
N+1 redundant configuration or 6 power supplies to support an N+N redundan
configuration.
HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply Kit (Recommended)
656364-B21
NOTE: Platinum power supplies are required to enable power discovery services.
NOTE:
NOTE: Certain HPE ProLiant server blades and options require the latest version of the
Onboard Administrator firmware. This firmware release may also require other subsystem
firmware upgrades. For information on the latest firmware versions, please see the Blad
Firmware Maintenance website at:
NOTE: For use with PDUs accepting C20 power cords.
NOTE:
HPE C13-NEMA 6-15P 10A/250V 3.6m Black Power Cord (Extended)
A0N33A
Step 4: Select one to four interconnects
The following is a list of various HPE BladeSystem c-Class interconnect modules (Virtual Connect, Ethernet, Fibre Channel, and
SAS interconnects). A pair of interconnects must be ordered if redundancy is required. For detailed interconnect options cons
the
HPE Virtual Connect Flex-10/10D Module for c-Class BladeSystem (Recommended)
638526-B21
HPE 10GbE Ethernet Pass-Thru Module for c-Class BladeSystem (Recommended)
538113-B21
supplies until all power supplies are matched.
The HPE AC Common Slot Platinum Plus Power Supply PN 656364-
puter industry, and consumers in an effort to
HPE highly recommends using the HPE Power Advisor tool to ensure the number
o review maximum system power ratings for facilities planning
http://www.hpe.com/info/hppoweradvisor
For a full enclosure, you can either order 4 or more power supplies to support an
t
Includes a 6ft C13 to C14 PDU power cord.
es
https://www.hpe.com/us/en/product-
-enclosures/pip.models.hpe-onboard-
Order 1 for each power supply.
specific interconnect QuickSpecs: https://www.hpe.com/h20195/v2/getpdf.aspx/c04284204.pdf?ver=10
Options to specific c-Class interconnects are not included in the list below. Consult the individual interconnect QuickSpecs
obtain part numbers for interconnect options such as cables, SFPs, etc.
Interconnect Bay 1 must contain one of the Network Interconnects.
The HPE BladeSystem c-Class interconnects ship as single units unless otherwise noted. Interconnects must be ordered
-Class Network
ult
QuickSpecs
Configuration Information Factory Integrated Models
Page 11
HPE 10GbE Ethernet Pass-Thru TAA-compliant Module II for c-Class BladeSystem
(Recommended)
854194-B22
HPE Cisco B22HP Fabric Extender for BladeSystem c-Class (Recommended)
641146-B21
HPE Cisco B22HP Fabric Extender with 16 FET for BladeSystem c-Class (Recommended)
HPE 1GB Ethernet Pass-Thru Module for c-Class BladeSystem (Extended)
406740-B21
NOTE: Includes 16 Cisco Fabric Extender Transceivers. These transceivers can be used to
connect the Fabric Extender with a parent Nexus 5000 over optical cable up to 100
meters using OM3 grade fiber.
HPE SAS Switch
HPE 6Gb SAS Switch Single Pack for HPE BladeSystem c-Class
BK763A
HPE 6Gb SAS Switch Dual Pack for HPE BladeSystem c-Class
BK764A
NOTE: Please see the QuickSpecs for Technical Specifications and additional information
at:
(Worldwide)
HPE BladeSystem
c
Interconnects
HPE BladeSystem c-Class FC SAN Interconnects - Recommended
HPE 4GB Fibre Channel Pass-thru Module for c-Class BladeSystem (Recommended)
403626-B21
HPE BladeSystem c-Class FC SAN Interconnects - Extended
Select HPE PDUs and UPSs are listed later in this document. For additional HPE PDUs and UPSs, please
http://www.hpe.com/info/rackandpower
(For connection to standard wall outlets)
Select one wall outlet power cord for each power supply when plugging the power supplies into a wall outlet.
Wall Outlet power cords should only be used with low-line (100VAC to 110VAC) power sources. If high-
A standard 6ft PDU power cord (C13 to C14) is included with each AC power supply, so these wall outlet power cords are
Order the appropriate power cord for your countries standard electrical outlets.
For additional power cable information, please visit: http://www.hpe.com/info/rackandpower
QuickSpecs
HPE BladeSystem c3000 Enclosure
Configuration Information Factory Integrated Models
NOTE: Contains 1 each of c3000/c7000 Active Cool Fan blank, c3000/c7000
interconnect module blank, c7000 Onboard Administrator blank, c3000 local KVM blank,
c3000 power supply blank, c7000 power supply blank, c3000 DVD blank, and a c3000
mini
NOTE:
HPE c-Class BladeSystem Bay Blank with Coupler Option (Recommended)
412150-B21
NOTE: This is option contains one half-height device blank and a coupler that can be used
for the c3000 and c7000 enclosures.
NOTE: Second Onboard Administrator Module for the DDR2 OA module.
NOTE:
NOTE:
HPE c-Class Power
Supply
HPE c-Class Power Supply - Recommended
NOTE: Each enclosure must include only one type of power supply. Mixing of power
supplies is not supported, except during hot swaps to different level or higher efficient
power supplies. The Onboard Administrator will exhibit a mismatch error due to mixed
power
NOTE:
B21 meets the
80 PLUS Platinum power 94% efficiency requirement. The 80 PLUS program is a unique
forum that unites electric utilities, the computer industry, and consumers in an effort to
bring e
tests power supply efficiency and publically posts the results on 80Plus.org.
NOTE:
of power supply o
configuration and t
purposes. HPE Power Advisor is available at:
.
NOTE:
N+1 redundant configuration or 6 power supplies to support an N+N redundant
configuration.
have been selected by Hewlett Packard Enterprise experts to provide the right technology for a range of
. Fully integrated into the ProLiant management and security experience, Recommended Options
View the list for your region.
provide an extended catalog of products tailored for customers in specific markets or with specific workloads,
Fully integrated into the ProLiant management and security experience, Extended
-time.
-divider.
This kit should only be ordered to replace lost or damaged blanks.
Order quantity of one 412150-B21 for filling a half-height bay; the coupler is not
Order quantity of two 412150-B21 for filling a full-height bay. One coupler is
-height blanks to be connected together to create a full-
This kit should only be ordered to replace lost or damaged blanks.
Support for second Order Administrator Module for c3000 Enclosure.
This module fits into an HPE c3000 DDR2 Onboard Administrator.
supplies until all power supplies are matched.
The HPE AC Common Slot Platinum Plus Power Supply PN 656364-
nergy efficient technology solutions to the marketplace. 80 PLUS independently
HPE highly recommends using the HPE Power Advisor tool to ensure the number
ptions you have selected can fully support your BladeSystem
o review maximum system power ratings for facilities planning
http://www.hpe.com/info/hppoweradvisor
For a full enclosure, you can either order 4 or more power supplies to support an
Page
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
Page 14
HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply Kit (Recommended)
656364-B21
NOTE: Platinum power supplies are required to enable power discovery services
NOTE:
Brocade 8/24c Power Pack+ SAN Switch for BladeSystem c-Class
AJ822C
Brocade 8/16Gb Embedded FC Switch 12-port Upgrade LTU
T5517A
HPE iLO Advanced
for BladeSystem
License
HPE iLO Advanced for BladeSystem 8-server License with 1yr Support on iLO Licensed
Features
512489-B21
HPE Virtual
Connect Enterprise
Manager
HPE Virtual Connect Enterprise Manager including 1yr 24x7 Support Single c3000
Enclosure LTU
459867-B21
NOTE: This license allows 1 BL-c3000 enclosure to be managed with VCEM. Customer will
receive a printed license entitlement certificate via physical shipment. The license
entitlement certificate must be redeemed online or via fax to obtain the license activatio
key(s). Includes one year of 24 x 7 HPE Software Technical Support and Update Service.
Options to specific c-Class interconnects are NOT included in the list below.
QuickSpecs to obtain part numbers for interconnect
Interconnect Bay 1 must contain one of the Ethernet capable interconnect
The HPE BladeSystem c-Class interconnects ship as single units unless otherwise
n
QuickSpecs
HPE BladeSystem c3000 Enclosure
Related Options
Page 15
NOTE:
visit:
(Worldwide)
HPE c-Class
Storage Blades
HPE c-Class Storage Blades - Recommended
HPE 10GbE Ethernet Pass-Thru Module II for c-Class BladeSystem (Recommended)
854194-B21
HPE D2220sb Build-to-order Storage Blade
QW917A
NOTE: Includes 3yr NBD Parts-Only Warranty Service
HPE D2220sb Configure-to-order Storage Blade
QW918A
NOTE: Includes 3yr NBD Parts-Only Warranty Service
NOTE: The D2220sb requires a c7000 Enclosure configuration with 10 fans.
NOTE: Please see the HPE D2220sb Storage Blade QuickSpecs for technical specifications
NOTE: For additional information regarding KVM switches, Serial Console servers, rack
mount monitors, keyboards and all related options please see the following
URL:
Rack Options - Extended
HPE Advanced Series Rack Tie Down Kit (Extended)
AF076A
NOTE: For additional information regarding Rack Options, please see the following
URL:
HPE Pointnext
operational
services
NOTE: Some options, such as Fibre Channel switches for the HPE c-Class BladeSystem,
are not covered under the c3000 enclosure Care Packs and carry separate Care Packs.
Care Pack service level support for these options should always be uplifted to match
existing storage or server service l
Please view the option QuickSpecs or contact your Hewlett Packard Enterprise sales
representative or Hewlett Packard Enterprise Authorized ServiceOne partner for Care
Pack information.
Proactive Care Services
HPE 3 year Proactive Care 24x7 c3000 Enclosure Service
U3C42E
HPE 3 year Proactive Care Call to Repair c3000 Enclosure Service
U3C45E
HPE 3 year Proactive Care 24x7 c3000 Enclosure with Insight Control Service
U3P19E
HPE 3 year Proactive Care Call to Repair c3000 Enclosure with Insight Control Service
U3P22E
Installation & Start-up Services
HPE Installation c3000 Enclosure and Server Blade Service
UH749E
HPE BladeSystem c3000 Infrastructure Startup Service
UF817E
HPE BladeSystem c3000 + OS Startup Service
UF818E
HPE BladSys c3000 Encd Network Startup Service
UF814E
HPE Hardware Install c-Class Enclosure and Server Blade Service
UE494E
NOTE:Additional HPE Pointnext operational services can be found
at: https://www.hpe.com/us/en/services/it-support.html
Please see the QuickSpecs for Technical Specifications and additional
HPE 1200W Common Slot Platinum Hot Plug Power Supply Kit
Part Number
656364-B21
Input Voltage Range ( V rms )
100-240
Frequency Range (Nominal) ( Hz )
50 / 60
Nominal Input Voltage (
100 120 200 208 220 230 240
Maximum Rated Output Wattage
800
900
1200
1200
1200
1200
1200
Nominal Input Current ( A rms )
9.1
8.4
6.7
6.4
6.1
5.8
5.5
Maximum Rated Input Wattage Rating ( Watts )
897
999
1321
1319
1317
1315
1314
Maximum Rated VA ( Volt-Amp )
909
1012
1338
1337
1334
1332
1331
Efficiency ( % )
89.2
90.1
90.9
91.0
91.1
91.2
91.3
Power Factor
0.998
Leakage Current ( mA )
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Maximum Inrush Current (A peak )
30
Maximum Inrush Current duration ( mS )
20
Maximum British Thermal Unit Rating ( BTU-Hr )
3061
3408
4506
4501
4493
4487
4483
HPE 1200W Common Slot Silver Hot Plug Power Supply Kit
Part Number
500172-B21
Input Voltage Range ( V rms )
100-240
Frequency Range (Nominal) ( Hz )
50 / 60
Nominal Input Voltage ( Vrms )
100
120
200
208
220
230
240
Maximum Rated Output Wattage
800 900 1200
1200
1200
1200
1200
Nominal Input Current ( A rms )
9.7
9.0
7.0
6.8
6.4
6.1
5.9
Maximum Rated Input Wattage Rating ( Watts )
930
1034
1348
1348
1348
1348
1348
Maximum Rated VA ( Volt-Amp )
970 1079
1406
1406
1406
1406
1406
Efficiency ( % )
86
87
89
89
89
89
89
Power Factor
0.97
Leakage Current ( mA )
0.42 0.50 0.83 0.87 0.92 0.96
1.00
Maximum Inrush Current (A peak )
30
Maximum Inrush Current duration ( mS )
20
Maximum British Thermal Unit Rating ( BTU-Hr )
3174
3530
4600
4600
4600
4600
4600
Specifications
Vrms )
Page
QuickSpecs
HPE BladeSystem c3000 Enclosure
Server Blade, Expansion Blade, and Fan Population Guidelines
20
Fan & power supply bay numbering
Rack power supply bay numbering
Fan bay numbering
Power supplies and fans must be placed in the following bays
Number of Fans
Fan Bays Used
4
2,4,5, 6
6
All bays filled
Number of Power Supplies
(for PS Redundant or non-redundant mode)
Power Supply Bays Used
2
1 & 2
3
1, 2, & 3
4
1, 2, 3, & 4
5
1 through 5
6 All bays
Number of Power Supplies (for AC Redundant mode)
Place Power Supplies in Bays:
2
1 & 4
4
1, 2, 4, & 5
6
All bays filled
NOTE: With four fans, the enclosure will support only 4 half-height server blades in the bottom half of the enclosure device bays.
With six fans, all 8 server bays may be filled.
NOTE:
ct bays. The Onboard Administrator will ensure
that fans and blades are correctly placed before allowing the system to power on.
The c3000 enclosure is divided into 2 zones by the horizontal support metalwork. The lower zone (zone 1) includes bays 1,
and 6. The upper zone (zone 2) contains bays 3, 4, 7, and 8. Within each zone a removable bay divider is used to support half
height devices. To install a full
NOTE:
Guide" for more information on the use, installation, and removal of bay dividers.
For correct operation, fans and server blades must be installed in the corre
2, 5,
-
-height blade in either zone this bay divider must be removed.
Please read the RTF card (included with each c3000 enclosure) and the "HPE BladeSystem c3000 Setup and Installation
Page
QuickSpecs
HPE BladeSystem c3000 Enclosure
Server Blade, Expansion Blade, and Fan Population Guidelines
Page 21
Half-height server blade bay numbering
HPE BladeSystem c3000 Enclosure – Racks
1.
Device Bay 1
2.
Device Bay 2
3.
Device Bay 3
4.
Device Bay 4
5.
Device Bay 5
6.
Device Bay 6
7.
Device Bay 7
8.
Device Bay 8
NOTE: Half-height server blades should be populated from the bottom half of the enclosure, in the following order (bays 1, 5, 2,
6, 3, 7, 4, & 8)
Full-height server blade bay numbering
HPE BladeSystem c3000 Enclosure – Racks
1.
Device Bay 1
2.
Device Bay 2
3.
Device Bay 3
4.
Device Bay 4
NOTE:
bays can be used. With six fans, all bays can be used.
Full-height servers should be populated from the bottom to the top (bays 1 through 4). With four fans, only the bottom 2
QuickSpecs
HPE BladeSystem c3000 Enclosure
Server Blade, Expansion Blade, and Fan Population Guidelines
Page 22
Full-height and half-height server blade mixed configurations
Each enclosure zone can support up to 1 full-height, double wide server blade, up to 2 full-height, single-wide server blades, or up to
4 half
server blades. A mixture of blades sizes is not supported in zone 1.
An overview of the mixed server blade population rule best practices are summarized below. For detailed expansion blade rules
guidelines, please see the documentation that ships with the enclosure and server blade.
NOTE:
Guide" for more information on the use, installation, and removal of bay dividers and the mini
NOTE:
information, please see the "Expansion blades" section later in this document.
Expansion blades
Expansion blades consist of storage blades, tape blades, and the PCI Expansion Blade. Up to 4 expansion blades are supported per
HPE
sin
installed directly above a server blade, also known as a partner server blade. An overview of the expansion blade population
best practices are summarized below. For detailed expansion blade rules and guidelines, please see the documentation that shi
with the enclosure and expansion blade.
Expansion blade population best practices for half
Expansion blade population best practices for full
height devices directly
NOTE:
Guide" for more information on using bay dividers and the mini
NOTE:
expansion blade.
-height server blades. Additionally, zone 2 supports a mix of 1 full-height, single-wide server blade and up to 2 half-height
1. One full-height, single-wide server and up two half-height servers may be mixed in zone 2 (the upper zone); mixing is not
allowed in zone 1 (the lower zone).
2. The full-height, single wide server must be installed in the lower bays 3 and 7 and half-height server(s) directly above in
bays 4 and 8.
3. Half-height server blades should be installed in the order of bays 4 then 8.
4. Before installing any full-height server blades, remove the bay divider that is used to support half-height devices.
5. A mini-divider is installed between bays 4 and 8. A mini-divider is shipped with each c3000 enclosure.
Please read the RTF card (included with each c3000 enclosure) and the "HPE BladeSystem c3000 Setup and Installation
-divider for mixed configurations.
Expansion blades can be installed in zone 2 along with both full-height, single-wide and half-height blades. For more
and
BladeSystem c-Class c3000 Enclosure. Expansion blades may be installed in the same zone as half-height and full-height,
gle-wide server blades. Expansion blades are not supported with full-height, double-wide server blades. An expansion blade is
rule
1. One half-height partner server blade supports one expansion blade.
2. Identify the partner server blade to be installed with the expansion blade. The two blades always occupy a pair of slots as
follows: 1 & 2, 3 & 4, 5 & 6, and 7 & 8.
3. Each c3000 zone contains a removable divider (also known as a device bay shelf) that is used to support half-height
devices. This divider is remains installed whether the half-height devices are server or expansion blades.
-height server blades:
-height, single-wide server blades:
1. A full-height, single-wide server blade may be mixed with half-height expansion blades in zone 2 (the upper zone) of the
c3000 enclosure; mixing is not allowed in zone 1 (the lower zone).
2. The full-height, single-wide partner server blade must be installed in the lower bays 3 and 7 and half-
above in bays 4 and 8.
3. The full-height, single-wide server partner blade supports one or two expansion blades in bays 4 and 8.
4. Before installing any full-height, single-wide server blades, remove the bay divider that is used to support half-height
devices.
5. A mini-divider is installed between bays 4 and 8. A mini-divider is shipped with each c3000 enclosure.
6. If installing only one expansion blade, install the expansion blade in bay 8. The remaining half-height bay (bay 4) may be
populated with either a half-height device bay blank of a half-height server blade; the half-height server blade may not be
partnered with the expansion blade.
7. If installing two expansion blades, the expansion blades may be two storage blades, two tape blades, two PCI Expansion
Blades, or a mixture of any two.
8. Expansion blades are not supported with full-height, double-wide server blades.
Please read the RTF card (included with each c3000 enclosure) and the "HPE BladeSystem c3000 Setup and Installation
-divider for mixed configurations.
For detailed expansion blade rules and guidelines, please see the documentation that ships with the enclosure and
ps
QuickSpecs
Technical Specifications
23
Enclosure Unit
Dimensions
(with bezel)
10.4 x 19.1 x 32.977 in (265 x 485 x 835 mm)
Weight
Maximum
(one enclosure with 8 blades
and 4 interconnects installed)
300 lb (136 kg)
Minimum
(one enclosure without blades
and interconnects)
To review typical system power ratings use the Power Calculator online tool located at
URL: https://paonline56.itcs.hpe.com/?Page=Index
Power Supply Output
Rated Steady-State Power
800 W (at 100 VAC)
900 W (at 120 VAC)
1200 W (at 200 to 240 VAC)
Maximum Peak Power
880 W (at 100 VAC)
990 W (at 120 VAC)
1350 W (at 200 to
System Inlet
Operating
10° to 35°C (50° to 95°F) at sea level with an altitude
derating of 1.0°C per every 305 m (1.8°F per every
1000 ft) above sea level to a maximum of 3050 m
(10,000 ft), no direct sustained sunlight. Maximum ra
of change is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options installed.
System performance may be reduced if operating with
a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change
is 20°C/hr (36°F/hr).
Relative Humidity
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet
Altitude
Operating
3050 m (10,000 ft). This value may be limited by the
type and number of options installed. Maximum
HPE BladeSystem c3000 Enclosure
(H x W x D)
(approximate)
(per AC power supply)
264 VAC
(per power supply)
Temperature
240 VAC)
te
(non-condensing)
bulb temperature, non-condensing.
Page
QuickSpecs
HPE BladeSystem c3000 Enclosure
Technical Specifications
Page 24
allowable altitude change rate is 457 m/min (1500
ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared average
bystander position A
operati
accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296
(ECMA 109).
Idle
depends on server configuration & mix of server blades
Operating
varies by CPU utilization, server configuration, and mix
of server blades
Option Kits
Power Supply
Size
Height: 1.515 in (38.48 mm)
Width: 3.4 in (86.36 mm)
Depth: 7.5 in (190.5 mm)
Weight
2.5 lbs (1.13 kg)
Fan Option Shipping
Size
Height: 8.75 in (223 mm)
Width: 9.75 in (248 mm)
Depth: 15.88 in (403 mm)
Weight
4.0 lbs (1.8 kg)
Environment-
End-of-life
Hewlett Packard Enterprise offers end-of-life Hewlett Packard Enterprise product
return
information, please go to:
. To recycle your product,
please go to:
Packard Enterprise sales
be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment
information for each product type for use by treatment facilities. This information
(product disassembly instru
site at:
recyclers and other WEEE treatment facilities as well as
OEM customers who integrate and re-sell Hewlett Packard Enterprise equipment.
-Weighted sound pressure levels (LpAm) when the product is
ng in a 23°C ambient environment. Noise emissions were measured in
friendly Products
and Approach
Dimensions
Dimensions
Management and
Recycling
, trade-in, and recycling programs in many geographic areas. For trade-in
http://www.hpe.com/info/recycle
http://www.hpe.com/info/recycle or contact your nearest Hewlett
office. Products returned to Hewlett Packard Enterprise will
ctions) is posted on the Hewlett Packard Enterprise web
http://www.hpe.com/info/recycle. These instructions may be used by
Hewlett Packard Enterprise
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
25
Date
Version History
Action
Description of Change
06-Aug-2018
Version 71
Changed
Standard Features section was updated.
Removed
SKU was deleted: 461384-B21
04-Jun-2018
Version 70
Changed
Overview, Configuration Information - Factory Integrated Models, and Related
Options.
Removed
Obsolete SKUs were deleted:
H5M75A, BW903A, BW904A.
23-Oct-2017
Version 69
Changed
Care Pack naming and Service and Support- Parts and Materials updated.
12-Jun-2017
Version 68
Added
SKU added in Configuration Information Factory Integrated Models section:
854194-B22
Removed
Obsolete SKUs were deleted:
C6N32ABE, C6N33ABE.
03-Apr-2017
Version 67
Changed
URLs in document were updated.
Removed
Obsolete SKUs were deleted:
590863-B21, 431643-B21.
13-Feb-2017
Version 66
Changed
Configuration Information Factory Integrated Models and Related Options
sections were updated.
Added
SKU added:
854194-B21
Removed
Obsolete SKUs were deleted:
BD883A, BS580B.
10-June 2016
Version 65
Changed
Overview, Configuration Information Factory Integrated Models, Related
Options, and Power Specifications sections were updated.
Removed
Removed discontinued -48VDC product and notes from QuickSpecs:
437573-B21.
25-Mar-2016
Version 64
Changed
SKUs updated in Configuration Information - Factory Integrated Models and
AJ822C.
22-Jun-2015
Version 63
Changed
Related Options section was updated
Removed
Obsolete SKUs were deleted:
UF540E
20-Jan-2015
Version 62
Changed
Overview and Related Options sections were updated
Removed
Deleted SKU AF500A
B7E01A, AF506A, AF914A
07-Nov-2014
Version 61
Changed
Overview, Pre-configured Models and Configuration Information Factory
Integrated Models sections were updated
09-Sep-2014
Version 60
Changed
What's new, Configuration Information Factory Integrated Models, Related
Options sections were updated
Added
SKU Added:
696910-B21
Removed
Obsolete SKUs were removed:
AF603A, TC318A, AF508A, 498358-B21
Configuration Information and Related Options were revised.
10-Dec-2013
Version 55
Changed
Changes were made throughout the QuickSpecs.
22
Version 54
Section
13
Version 53
were revised.
15-Mar-2013
Version 52
Changed
Overview: Updated What's New section
Supply Kit and Note to section.
Removed
Removed "Platinum" reference throughout QS.
Removed NOTE from Technical Specifications section.
01-Mar-2013
Version 51
Removed
Related Options: Removed TC276AAE and TC277AAE from HPE Insight
Software section.
19-Feb-2013
Version 50
Changed
Changes made throughout the QS to reflect the title changes to HPE
Other changes made in the Configuration Information and Related Options.
14-Dec-2012
Version 49
Added
Configuration Information Factory Integrated Models: added models
Related Options: added parts in HPE Rack Series
24-Sep-2012
Version 48
Changed
Changes made throughout the QuickSpecs.
31-Aug-2012
Version 47
Changed
Changes made throughout the QuickSpecs.
14-May-2010
Version 46
Changed
Changes made in the Related Options section.
26-Mar-2012
Version 45
Changed
Changes made throughout the QuickSpecs.
06-Mar-2012
Version 44
Added
Added a reference to Gen8.
14-Nov-2011
Version 42
Changed
HPE Insight management software, Optimized, Standard and Basic Care
Packages and HPE c-Class Power Supply were revised.
29-Sep-2011
Version 41
Changed
Revisions made in the Configuration Information and Related Options sections.
26-Sep-2011
Version 40
Changed
Power Supplies, HPE BladeSystem c-Class Interconnects, HPE Ultrium Tape
What's New was added to the Overview
30-Aug-2011
Version 39
Changed
Standard and Basic Care Packages were updated in Service and Support
Models and Related Options
12-Aug-2011
Version 38
Changed
Link corrections were made in the Related Options section.
24-Jun-2011
Version 37
Changed
Changes made throughout the QuickSpecs. Including the removal of ProCurve
& StorageWorks.
03-Jun-2011
Version 36
Changed
Changes made to North America and Canada only.
29-Apr-2011
Version 35
Changed
The Service and Support section was completely revised and other changes
made throughout the QuickSpecs.
11-Feb-2011
Version 34
Changed
Mixed Configuration - Full Height and Half Height Population was revised
HPE c3000 Enclosure Options was removed from Related Options
14-Jan-2011
Version 33
Changed
HPE BladeSystem c-Class Interconnect and Mezzanine Components URLs
HPE Uninterruptible Power Systems product descriptions were revised
-Nov-2013
-Sep-2013
RemovedRemoved the What's New Section
Removed part number from the Related Options/ HPE c Class Power Supply
ChangedConfiguration Information Factory Integrated Models and Related Options
Models: Updated HPE BladeSystem c-Class Server Blade Enclosures
HPE BladeSystem c-Class Overview: Updated HPE ProLiant & Integrity Server
Blades and HPE D2200sb Storage Blade.
Configuration Information Factory Integrated Models: Updated Step 2.
Related Options: Updated HPE Onboard Administrator, HPE c-class Power
Supply, HPE Insight Software and HPE Storage Blade.
Power Specifications: HPE 1200W Common Slot Platinum Hot Plug Power
BladeSystem c3000 Platinum Enclosure.
Models section was updated.
Service and Support section was completely revised.
Blades and HPE Pointnext operational services were revised
Changes were made throughout Configuration Information Factory Integrated
HPE R5500 UPS Tower Conversion Kit was removed from HPE
Uninterruptible Power Systems - Rack
were modified in HPE BladeSystem c-Class Interconnects Options
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
Page 27
These fans are for the HPE BladeSystem c3000 CTO Enclosure note was
10-Jan-2011
Version 32
Changed
HPE StorageWorks D2200sb Storage Blade was added and HPE
HPE BladeSystem c-Class Ethernet Interconnects
15-Nov-2010
Version 31
Changed
Product descriptions were revised throughout, Brocade SAN Switch for HPE
Servers was removed.
08-Oct-2010
Version 30
Changed
HPE Tape Backup and HPE Pointnext operational services were revised
to Keyboards and Monitors
Removed
HPE BladeSystem c3000 Enclosure Tower was removed
HPE Disk Backup was removed from Related Options
02-Jul-2010
Version 29
Added
Mixing of the Active Cool 100 and Active Cool 200 in a c3000 enclosure is
not supported note was added to HPE c-Class Active Cool Fans.
Removed
Part numbers 508669-B21, AF600A and AF602A were removed and 2x16
Options.
21-Jun-2010
Version 28
Changed
HPE Rack 10000 G2 Series and HPE Rack Options were completely revised
HPE Insight Control for Linux was added to HPE Insight Software
Removed
HPE 1Gb Virtual Connect Ethernet Module for c-Class BladeSystem, HPE
audio, 6-2-pack were removed from HPE KVM Switch Options
28-Apr-2010
Version 27
Removed
Removed part number AH351B from a Note in Step 2A of the Configuration
Information section.
12-Mar-2010
Version 26
Changed
NOTE was added to HPE 1200W -48V DC Common Slot Power Supply and all
AF601A, were removed.
16-Feb-2010
Version 25
Changed
Changes were made throughout the Configuration Information Factory
Integrated Models and Related Options sections.
25-Nov-2009
Version 24
Changed
Minor edits were made within the QuickSpecs.
16-Nov-2009
Version 23
Changed
Changes were made throughout the QuickSpecs.
02-Oct-2009
Version 22
Changed
Changes made throughout the QuickSpecs except for the Models and
Technical Specifications sections.
25-Sep-2009
Version 21
Changed
Changes made to the North America and Canada versions only.
28-Aug-2009
Version 20
Changed
Changes made to the North America and Canada versions only.
removed from HPE c-Class Active Cool Fan in Step 2
HPE PCI Express Mezzanine pass-thru card for HPE BladeSystem was
removed from HPE c-Class Storage Blades
StorageWorks SB40c Storage Blade was removed
HPE Insight Control for BladeSystem Licenses, HPE Uninterruptible Power
Systems - Rack, HPE Insight Software and HPE Virtual Connect Enterprise
Manager product descriptions were revised
HPE Virtual Connect FlexFabric 10Gb/24-port Module for c-Class
BladeSystem is not compatible with the c3000 enclosure note was added to
BladeSystem c-Class was added and HPE StorageWorks Network Storage
Service and Support was added
HPE TFT7600 G2 KVM Console Rackmount Keyboard Monitors were added
What's New was removed from the Overview
HPE c3000 Enclosure DVD Drive was removed
HPE 4Gb Virtual Connect Fibre Channel Module for c-Class BladeSystem was
removed from Step 3
HPE Insight Control, Single-Server License including 1 year of 24x7 Technical
Support and Update was removed from HPE Insight Software
Console Switch with Virtual Media was removed from HPE KVM Switch
10Gb Ethernet BL-c Switch and 10GbE Dual Port Mezzanine Adapter for HPE
BladeSystem c-Class were removed from HPE BladeSystem c-Class Ethernet
Interconnects
HPE Brocade 4/12 SAN Switch, HPE Brocade 4/24 SAN Switch Power Pack
and HPE Brocade 4/24 SAN Switch were removed from HPE BladeSystem cClass FC SAN Interconnects
4x1x16 IP Console Switch with Virtual Media and HPE USB KVM Cable with
references to 2 x 1 x 16 IP Console Switch with Virtual Media, part number
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
Page 28
17-Jul-2009
Version 19
Changed
Revisions were made in the HPE BladeSystem c-Class Overview and Related
Options sections.
12-Jun-2009
Version 18
Added
Rack Rails to NOTE for HPE BladeSystem c3000 CTO Enclosure- Rack in Step
Related Options section
Changed
Updated the Keyboards and Monitors in the Related Options section
2A of the Configuration Information - Factory Integrated Models section
27-Apr-2009
Version 17
Added
HPE ProLiant Onboard Administrator to the HPE BladeSystem c-Class
Active Cool 100 Fan throughout the QuickSpecs
Changed
NOTE for HPE iLO Advanced Pack for BladeSystem or iLO Advanced and
HPE Modular Cooling from the Related Options section
26-Jan-2009
Version 16
Changed
Changes made throughout the entire QuickSpecs.
17-Nov-2008
Version 15
Changed
Changes were made to the following sections:
HPE BladeSystem c-Class Ethernet Interconnects
2 of the Configuration Information - Factory Integrated Models section
HPE StorageWorks D2D2504i Backup System to Data Protection in the
HPE BLc3000 Rack Rails was removed from Other Enclosure Options in Step
Overview section
purchase information NOTE for HPE Insight Control Suite (ICE) in the HPE
BladeSystem c-Class Overview section and a NOTE was added to HPE Insight
Control suite in the Related Options section
Replaced "ProLiant" with "Insight" for HPE Insight Essentials Foundation Pack
in Core Infrastructure Management in the HPE BladeSystem c-Class Overview
section
Revised Onboard Administrator for Tower Model and removed Power Supplies
from Step 2 of the Configuration Information Factory Integrated Models
section
Revised Additional c3000 Power Supplies and HPE Insight Control suite for
BladeSystem Licenses and added Redundant Onboard Administrator to Step
2a of the Configuration Information Factory Integrated Models section
Updates were made throughout the Models section and to the NOTES section
of the Configuration Information Factory Integrated Models section
Completely revised HPE StorageWorks Ultrium Tape Blades, HPE Insight
Control suite (ICE) and Server Management Stand Alone Software Products in
the HPE BladeSystem c-Class Overview and Related Options sections and
Data Protection in the Related Options section
Revisions were made throughout Step 2 and Step 2A in the Configuration
Information Factory Integrated Models section and to Service and Support
Offerings in the Related Options section
Removed 10642 G2 (42U) Rack Cabinet from HPE Rack 10000 G2 Series,
10642 Rear Extension Kit from Rack Options for Rack 10000 G2 Series and
Overview
What's New
At A Glance
HPE BladeSystem c-Class Overview
HPE BladeSystem Overview
HPE SB40c Storage Blade
HPE StorageWorks Tape Blades
HPE BladeSystem c-Class Interconnect Enclosure
HPE Insight Control Environment for BladeSystem Management Suite
Server Management Stand Alone Software
HPE Enterprise Configurator
Configuration Information Factory Integrated Models
Step 2A: Select additional optional enclosure options
Step 3: Select additional (one to four) interconnects
Related Options
Other c3000 enclosure options
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
Page 29
HPE BladeSystem c-Class FC SAN Interconnects
30-Oct-2008
Version 14
Removed
Removed model number 409513-B22 from the Related Options section.
15-Sep-2008
Version 13
Changed
Changes were made to the following sections:
HPE Monitored Power Distribution Unit
14-Jul-2008
Version 12
Added
Additions made to the Overview, HPE BladeSystem c-Class Overview,
HPE D2D Backup Systems
Changed
Change was made to MSA1000 in Factory Express Portfolio in the HPE
section
11-Apr-2008
Version 11
Changed
Changes made to the North America and Canada QuickSpecs only.
31-Mar-2008
Version 9 to 10
Added
Cisco Catalyst Blade Switch 3120X, Part #451439-B21 and Cisco Catalyst
Blade, Part #461273-001, was added to the Smart Buys section.
Changed
Changes were made in the Overview, HPE BladeSystem c-Class Overview,
Configuration Information and Related Options sections.
14-Mar-2008
Version 9
Changed
Changes made to the North America and Canada QuickSpecs only.
03-Mar-2008
Version 8
Changed
Changes made to the North America and Canada QuickSpecs only.
11-Feb-2008
Version 7
Changed
Changes were made throughout the QuickSpecs.
18-Jan-2007
Version 6
Changed
Changes made to the North America and Canada QuickSpecs only.
14-Jan-2008
Version 5
Added
The HPE BladeSystem c3000 Enclosure - Tower Model option was added.
Changed
Changes were made throughout the QuickSpecs to reflect the addition of the
tower option.
02-Nov-2007
Version 4
Changed
Changes made to the At A Glance section.
05-Oct-2007
Version 3
Changed
Changes made to the Service and Support Offerings section of Related
Options.
Overview
What's New
At A Glance
HPE BladeSystem c-Class Overview
HPE BladeSystem Overview
HPE BladeSystem c-Class c3000 Enclosure
HPE Insight Control Environment for BladeSystem Management Suite
Configuration Information Factory Integrated Models
Step 2: Determine quantity of HPE BladeSystem c-3000 Enclosures to
purchase and choose Required Options
Step 2A: Select additional optional enclosure options
Step 3: Select additional (one to four) interconnects
Step 4: Select rack power distribution for installing the enclosure into a rack.
Related Options
c3000 Enclosure Options
HPE BladeSystem c-Class c3000 Enclosure
Other c3000 enclosure options
HPE BladeSystem c-Class FC SAN Interconnects
Configuration Information and Related Options sections:
HPE 8/12 and 8/24 SAN Switch c-Class BladeSystem
Power Cord, C20 C13, 15A, Universal Jumper, 2m
BladeSystem c-Class Overview section and to Data Protection in the Related
Options section
HPE Insight Control Environment for BladeSystem Management Suite
Server Management Stand Alone Software Product
NOTES section for HPE NC512m Dual Port 10GbE Multifunction BL-c
Adapter in HPE BladeSystem c-Class Ethernet Connects
Headings for HPE Modular Power Distribution Unit and Uninterruptible Power
System in Step 4 of the Configuration Information Factory Integrated Models
section
Monitors and Keyboards and HPE KVM Switch Options in the Related Options
Blade Switch 3120G, Part #451438-B21, were added to the Configuration
Information and Related Options sections and BL460c Smart Buy Server
QuickSpecs
HPE BladeSystem c3000 Enclosure
Summary of Changes
Page 30
01-Oct-2007
Version 2
Changed
Changes made to the North America and Canada QuickSpecs only.
subject to change without notice. The only warranties for Hewlett Packard Enterprise products and
services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise
shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel, the Intel logo,
Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. AMD is a US
registered trademark of AMD Corporation.