HPE 513778-B21 Getting Started Guide

QuickSpecs
HPE Smart Array P711m Controller
Overview
Page 1
HPE Smart Array P711m Controller
The HPE Smart Array P711m is a PCI-Express (PCIE) mezzanine card supporting shared and direct attached SAS Storage. It is one of the highest performing controllers in the storage performance for Supports up to 108 zoned direct attached SAS or SATA hard drives per HPE Smart Array P711m Controller.
HPE Smart Array P711m Controller
What's New
Support for HPE MSA 2040 Storage
Models
HPE Smart Array P711m/1G 6Gb FBWC 4-ports Ext Mezzanine SAS Controller
513778-B21
NOTE: For MDS600 host connectivity, P711m firmware 5.32 or higher, 6Gb BL SAS switch firmware 2.0.1.0
switch firmware 2.0.1.0or higher and D2600/D2700 firmware 1.34 or higher are required.
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
HPE 6Gb/s SAS portfolio and provides new levels of reliability, connectivity, and
HPE Blade servers through its support of the latest SCSI technology and advanced RAID capabilities.
or higher and MDS600 firmware 3.44 are required.
NOTE: For D2600/D2700 support in Blade configuration, P711m firmware 5.32 or higher, 6Gb BL SAS
QuickSpecs
HPE Smart Array P711m Controller
Standard Features
Page 2
The Smart Array Advantage
The innovative design of Hewlett Packard Enterprise and integration work within the Smart
Failure Warranty means Systems Insight Manager not only reports
Key Features
Smart Array PCIe mezzanine card that connects to a HPE 6Gb/s SAS BL Switch through the c-
paths are load balanced for improved performance when
Online Management Features
Performance
Eight (8) 6Gb/s SAS physical links distributed across 4 external 2x ports which supports up to
attaching 2 SAS cables from any quad of 6G SAS Switch ports to the 2 ports on the MDS600
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HPE Smart Array family brings an unparalleled return on investment.
Data Compatibility Data Compatibility with all Serial Smart Array controllers allows simple
and easy upgrades any time needs for higher performance, capacity, and availability increase.
Consistent Configuration and Management Tools. All Smart Array products utilize a
standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain HPE server storage.
Pre-Failure Warranty Pre-
when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HPE Support Center or refer to your HPE Server documentation
Class enclosure high-speed mid-plane supporting shared SAS storage.
Eight (8) 6Gb/s SAS physical links distributed across 4 external 2x ports to supports up to 4
6Gb/s SAS Switches
Storage interface (SAS/SATA)
o 6Gb/s SAS technology delivers up to 600 MB/s per physical link. o 3Gb/s SATA technology delivers up to 300 MB/s for directly attached SATA drives. o Mix-and-match SAS and SATA drives. Deploy drive technology as needed to fit the
computing environment.
o Support for SAS tape drives, SAS tape autoloaders and SAS tape libraries.
RAID controller features
o 1 GB flash-backed write cache (not all of which is available for user data) o RAID 0, 1, , 5, 6, 50, 60 o RAID configuration for shared storage is controlled by the Array Controller of
enclosure the array
RAID 0.1.3, 5.6.10.50
License key for Smart Array Advanced Pack (SAAP) included
Software consistency among all Smart Array family products: Array Configuration Utility,
Systems Insight Manager, Array Diagnostic Utility (ADU) and SmartStart
1G Flash Backed Write Cache (FBWC) provides indefinite write cache data retention in the
case of unexpected power outage.
Multi-path support available in Smart Array firmware when using zoned direct attached
storage. Both direct attached storage using the enclosure in dual domain mode using SAS HDDs.
Online Array Expansion
Online RAID Level Migration Online Stripe Size Migration Online Spares (Global)
User Selectable Expand and Rebuild Priority
Online Logical Drive Extension Availability
4 6Gb/s SAS Switches
6Gb/s SAS (600MB/s bandwidth per physical link)
The P711m supports higher performance between the 6G SAS Switch and MDS600 by
QuickSpecs
HPE Smart Array P711m Controller
Standard Features
Page 3
IO module to create an 8x wide SAS port
Capacity
Dependent upon attached enclosures and arrays.
NOTE:
https://www.hpe.com/h20195/v2/gethtml.aspx?d
(
https://www.hpe.com/h20195/v2/gethtml.aspx?docname=c04140213
(
https://www.hpe.com/h20195/v2/gethtml.aspx?docname=c04168365
(HPE P2000 G3 Modular Smart Array Systems)
Availability
Provides increased server uptime by providing advanced storage functionality:
Fault Tolerance RAID Descriptions
Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including:
(Distributed Data Guarding): Supported with a minimum of 3 drives. This allocates one
parity group can sustain a single drive failure without
NOTE:
Module Option Kit or to D2600/D2700 with dual domain SAS HDDs paths to each HDD, enabling the server to endure P711m port failures, switch failures, cable pulls, cable failures, and MDS600 IO module failures without interruption of normal storage I/O.
NOTE:
Arrays at: https://www.hpe.com/h20195/v2/gethtml.aspx?docname=c04168365
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
1G Flash Backed Write Cache
Please see the QuickSpecs for Technical Specifications and additional information:
ocname=c04123144
HPE MSA 2040 Storage)
HPE 600 Modular Disk System)
Online RAID Level Migration (between any RAID level)
Online Capacity Expansion
Logical Drive Capacity Extension
Global Online Spare
Pre-Failure Warranty
RAID 6 (Advanced Data Guarding): Supported with a minimum of 4 drives. This allocates two
sets of parity data across drives. This level of fault tolerance can withstand a double drive failure without downtime or data loss.
RAID 60: Supported with a minimum of 8 drives. This volume is composed of two or more
RAID 6 sub-volumes (parity groups) where data is striped across each parity group as if it were a single physical drive. Each RAID 6 parity group can sustain up to two drive failures without incurring data loss.
RAID 5
set of parity data across drives. This level of fault tolerance can withstand a single drive failure without downtime or data loss.
RAID 50: Supported with a minimum of 6 drives. This volume is composed of two or more
RAID 5 sub-volumes (parity groups) where data is striped across each parity group as if it were a single physical drive. Each RAID 5 incurring data loss.
RAID 1 & 10 (Drive Mirroring): Supported with a minimum of 2 drives. This allocates half of
the drive array to the data and the other half to the mirrored data, providing two copies of the data.
RAID 1 ADM & 10 ADM (Advanced Data Mirroring): Supported with a minimum of 3 drives.
RAID 1 ADM creates redundant copies of the data using 3 drives. RAID 10 ADM stripes data across two or more sets of RAID 1 ADM volumes. This level of fault tolerance can withstand a double drive failure within a RAID 1 ADM volume without downtime or data loss.
When the P711m is connected to the MDS600 configured with the HPE MDS600 Dual I/O
See Enclosure QuickSpecs for descriptions of RAID levels specific to the HPE P2000 G3
, there are multiple physical
QuickSpecs
HPE Smart Array P711m Controller
Standard Features
Page 4
Fault Recovery
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure
corruption. A new version of firmware can be flashed to the ROM while the controller maintains
rking version of firmware. If the firmware becomes corrupt, the controller will
Ease of Use
Consistency and Upgradeability make the Smart Array family unique in the industry:
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
Recovery ROM: This feature provides unique redundancy that protects from a ROM image
the last known wo revert back to the previous version of firmware and continue operating. This reduces the risk of flashing firmware to the controller.
On-Line Spares: There is no limit to the number of spare drives that can be installed prior to
drive failure. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically.
GUI based configuration, management and diagnostic software tools
Common data format between generations of products