QuickSpecs
Overview
HP Smart Array P712m Controller
The HP Smart Array P712m mezzanine card is the preferred high value solution for 6Gb/s Shared SAS Storage for the HP ProLiant BladeSystem servers. It is one of the highest performing controllers in the SAS portfolio and provides new levels of reliability for the HP BladeSystem through its support of the latest SCSI technology and advanced RAID capabilities. Supports up to 4 P2000 Smart Arrays.
What's New
Support for HP MSA 2040 Storage
Models
HP Smart Array P712m/ZM 2-ports Int PCIe x8 SAS Controller HP Smart Array P712m/256 6Gb 2-ports Int/2-ports Ext Mezzanine SAS Controller
NOTE:
In order to support SAS Hard Drives the server blade must have a P712m Controller installed in server
mezzanine slot 1 or mezzanine slot 2.
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 1
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Standard Features
The Smart Array Advantage
Key Features
HP's innovative design and integration work within the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HP Smart Array family brings an unparalleled return on investment.
Data Compatibility
upgrades any time needs for higher performance, capacity, and availability increase.
Consistent Configuration and Management Tools
management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain HP server storage.
Pre-Failure Warranty
drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation.
HP Smart Array P712m Controller
. Data Compatibility with all Serial Smart Array controllers allows simple and easy
. All Smart Array products utilize a standard set of
. Pre-Failure Warranty means Systems Insight Manager not only reports when a
Storage interface (SAS/SATA)
6 Gb/s SAS technology delivers up to 600 MB/s per physical link. 3 Gb/s SATA technology delivers up to 300 MB/s for directly attached SATA drives. Mix-and-match SAS and SATA drives. Deploy drive technology as needed to fit the computing environment. Support for SAS tape drives, SAS tape autoloaders and SAS tape libraries.
RAID controller features
256 MB cache RAID 0, 1 RAID 0, 1, 3, 5, 6, 10, 50 on P2000 G3 SA (for shared storage)
NOTE:
RAID for Shared Storage is controlled by the controller of the array.
Recovery ROM protects against ROM corruption. Smart Array PCIe mezzanine card that connects to a HP 6Gb/s SAS BL Switch through the c-Class enclosure high-speed mid-plane supporting shared SAS storage. Four (4) 6Gb/s SAS physical links distributed across 2 external 2x ports to supports up to 2 6Gb/s SAS Switches Two (2) 6Gb/s SAS physical links distributed across 2 internal 1x ports to support up to 2 6Gb/s SAS HDDs Software consistency among all Smart Array family products: Array Configuration Utility, Systems Insight Manager, Array Diagnostic Utility (ADU) and SmartStart
Online Management Features
Online array expansion (with cache) Online logical drive extension (with cache) Online RAID level migration (with cache) Online strip size migration (with cache) User selectable rebuild priority User selectable RAID level and stripe size
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 2
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Standard Features
HP P2000 G3 Modular Smart Array Systems
Online Management Features:
HP Storage Management Utility (SMU).
P2000 G3 Smart Array Systems - RAID 0, 1, 3, 5, 6, 10, 50:
In addition to the usual RAID levels, the P2000 G3 features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through the addition of RAID 0, particularly during writes.
HP Smart Array P712m Controller
Management access, out-of-band:
WEB GUI, CLI. Interface Types:
USB, 10/100 Ethernet. Protocols Supported:
SNMP, SMI-S, SSL, SSH, SMTP, FTP, HTTP, Telnet
Performance
Capacity
Availability
Fault Prevention
6Gb/s SAS (600MB/s bandwidth per physical link) 256 MB Cache available (256 MB cache enables use of the external ports)
Dependent upon attached arrays. See drive enclosure QuickSpecs for details.
Provides increased server uptime by providing advanced storage functionality:
Online RAID Level Migration (0,1) Pre-Failure Warranty
NOTE:
This is not applicable for P2000.
The following features offer detection of possible failures before they occur, allowing preventive action to be taken:
S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HP detects possible hard disk failure before it occurs, allowing replacement of the component before failure occurs. Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying the administrator. Dynamic Sector Repairing continually performs background surface scans on the hard disk drives during inactive periods and automatically remaps bad sectors, ensuring data integrity. Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure preventative maintenance.
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 3
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Standard Features
Fault Tolerance RAID Descriptions
Fault Recovery
Keeps data available and server running while a failed drive is being replaced; two fault tolerance configurations are supported for the internal connections including:
NOTE:
and additional information regarding RAID levels:
http://h18000.www1.hp.com/products/quickspecs/13551_div/13551_div.html
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure:
HP Smart Array P712m Controller
RAID 0 (striping) provides no extra data protection. Data is striped across all drives in the array to increase performance. RAID 0 requires a minimum of one drive. RAID 1 (mirroring) protects against failure of one drive. Data is duplicated on a pair of drives. RAID 1 requires a minimum of two drives.
Please see the HP P2000 G3 Modular Smart Array Systems QuickSpecs for Technical Specifications
Recovery ROM: This feature provides unique redundancy that protects from a ROM image corruption. A new version of firmware can be flashed to the ROM while the controller maintains the last known working version of firmware. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. This reduces the risk of flashing firmware to the controller. DRAM ECC corrects against single bit data and address corruption.
Ease of Use
Consistency and Upgradeability make the Smart Array family unique in the industry:
GUI based configuration, management and diagnostic software tools Common data format between generations of products
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 4
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Compatibility
Supported Servers
Operating Systems and Virtualization Software Support for ProLiant Servers
HP ProLiant BL280c G6 HP ProLiant BL460c G7 HP ProLiant BL465c G7 HP ProLiant BL490c G7 HP ProLiant BL495c G5 HP ProLiant BL495c G6 HP ProLiant BL620c G7 HP ProLiant BL680c G7 HP ProLiant BL685c G7
NOTE: NOTE:
please visit:
Microsoft Windows 2003 Microsoft Windows 2008 R2 SLES 10 SP3 SLES 11 SP1 Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 VMware ESX 4.0 VMware ESX 4.1 VMware ESXi 5.0
NOTE:
Software and latest listing of software drivers available for your server, please visit our Support Matrix at:
http://www.hp.com/go/supportos
HP Smart Array P712m Controller
Some servers listed above may be discontinued. For more information on internal vs external connections, please refer to proper blade QuickSpecs
http://h18000.www1.hp.com/products/quickspecs/division/12534.html
For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization
.
Software Suite
All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility, Array Diagnostic Utility (ADU), and Systems Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage.
Systems Insight Manager
HP Array Configuration Utility
(ACU)
HP Option ROM Configuration for Arrays
(ORCA)
DA - 13296 Worldwide — Version 15 — November 8, 2013
Powerful server and server options/storage manager tool Monitors over 1200 system wide parameters Configuration/Diagnostic Utilities
Powerful Web based configuration utility for all Smart Array controllers Provides a graphical view of HP server drive array configurations Allows for management of multiple arrays over a secure internet connection from anywhere in the world Easy to use Wizards for configuration Runs offline (via Smart Start) and online on Windows
An alternative method for easily viewing, creating, and deleting multiple arrays and logical volumes during system power up. For advanced array configurations use ACU
Page 5
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Compatibility
HP Storage Management Utility
HP Array Diagnostic Utility
HP Smart Array P712m Controller
Initial System Configuration Wizard is the easiest and simplest method for configuring the storage system initially. Command Line Interface (CLI) for command level method of configuring and managing the storage Main User Interface for multi server environments that need customization for creation of storage Luns and targets. P2000 G3 Arrays can be configured using Storage Management Utility (SMU) or Command Line Interface (CLI) both of which are embedded in the P2000 G3 Array controller firmware.
In depth diagnostic and reporting utility for all Smart Array controllers
(ADU)
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 6
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Service and Support, HP Care Pack, and Warranty Information
Warranty
Software Product Services
Hardware Product Services
Warranty Upgrade Options
The warranty for this device is 3 years parts only.
Pre-Failure Warranty
are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support Center or refer to your HP Server Documentation.
Standalone telephone support Rights to new license version Media and documentation updates
Installation services On-site maintenance (includes warranty support) Response time upgrades during the warranty period Post-warranty coverage RAID setup and performance consulting via statement of work
Response Coverage Duration
Warranty upgrade options can come in the form of Care Packs, which are sold at the HP System level this product attaches too.
- Upgrade on-site response from next business day to same day 4 hours
- Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
- Select duration of coverage for a period of 1, 3, or 5 years
: Drives attached to the Smart Array Controller and monitored under Insight Manager
HP Smart Array P712m Controller
HP Care Pack Information
HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. Care Packs for this option is sold at the system level this option attaches too.
HP Care Pack is not available for less than the product's warranty duration. HP Care Pack is available for sale anytime during the warranty period for most products, but the
commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required.
HP Care Pack services are prepaid.
NOTE:
For additional HP Care Pack (hardware & software) information, as well as orderable part numbers,
please refer to the URL:
http://www.hp.com/hps/carepack/
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 7
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Related Options
HP Hard Drives
NOTE:
P2000 Large Form Factor (LFF) SAS drives for P2000 G3 FC and P2000 3.5-inch Disk Enclosure
HP P2000 300GB 6G SAS 15K rpm LFF Dual Port Enterprise Hard Drive HP P2000 450GB 6G SAS 15K rpm LFF Dual Port Enterprise Hard Drive HP P2000 600GB 6G SAS 15K rpm LFF Dual Port Enterprise Hard Drive
P2000 Large Form Factor (LFF) SAS MDL DP drives for P2000 G3 FC and P2000 3.5­inch Disk Enclosure
HP StorageWorks P2000 1TB 6G SAS 7.2K LFF (3.5-inch) Dual Port MDL Hard Drive HP StorageWorks P2000 2TB 6G SAS 7.2K LFF (3.5-inch) Dual Port MDL Hard Drive
MSA2 Large Form Factor (LFF) SATA drives for P2000 array head an P2000 disk enclosure
HP StorageWorks MSA2 1TB 7.2K rpm 3.5 inch Dual-port SATA Hard Disk Drive HP StorageWorks P2000 2TB 3G SATA 7.2K LFF MDL Hard Drive
SAS Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives
NOTE:
HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive HP 450GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive HP 600GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive
NOTE:
http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html
(Worldwide)
SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives
NOTE:
HP 500GB 6G SAS 7.2K rpm SFF (2.5-inch) Dual Port Midline 1yr Warranty Hard Drive
NOTE:
http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html
(Worldwide)
SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives
NOTE:
intrinsic to their design.
NOTE:
HP 500GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive
NOTE:
information:
http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html
(Worldwide)
HP Smart Array P712m Controller
Supports attached enclosures.
Supports P2000 G3 Array (24 drive bay) and the D2700 JBOD (25 drive bay).
Please see QuickSpecs for Technical Specifications and additional information:
Supports P2000 G3 Array (24 drive bay) and the D2700 JBOD (25 drive bay).
Please see QuickSpecs for Technical Specifications and additional information:
SFF SATA drives are single ported and therefore do not have a fail-over path
Supports P2000 G3 Array (24 drive bay) and the D2700 JBOD (25 drive bay).
Please see the QuickSpecs for Technical Specifications and additional
AP858A AP859A AP860A
AP861A
AW555A
AJ740A
AW556A
HP SAS Switches
HP StorageWorks 6Gb/s SAS BL Switch - Single Pack HP StorageWorks 6Gb/s SAS BL Switch - Dual Pack
NOTE:
Please see the QuickSpecs for Technical Specifications and additional information at:
http://h18000.www1.hp.com/products/quickspecs/13960_div/13960_div.html
DA - 13296 Worldwide — Version 15 — November 8, 2013
BK763A BK764A
Page 8
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Related Options
HP c Class Blade Enclosures
HP P2000 G3 Modular Smart Array Systems and HP MSA 2040 Storage Array
HP BLc7000 CTO 3 IN LCD ROHS Encl HP BLc7000 1PH 2PS 4 Fan TL ROHS ICE HP BLc7000 1PH 6PS10Fan Fl ROHS 16IC Kit HP BLc7000 3PH 6PS 10 Fan INT ROHS ICE HP BLc7000 3PH 6PS10FanENG ROHS IC Kit
P2000 G3 SAS Controller
HP StorageWorks P2000 G3 SAS MSA Array System Controller (four 6Gb SAS ports per controller)
P2000 Chassis P2000 Controller-less Chassis (AC-powered)
HP StorageWorks P2000 Modular Smart Array 3.5-in Drive Bay Chassis (LFF)
NOTE:
HP StorageWorks P2000 Modular Smart Array 2.5-in Drive Bay Chassis (SFF)
NOTE:
Configured Units, 6 Gb SAS Systems
HP StorageWorks P2000 G3 SAS MSA Dual Controller LFF Array System HP StorageWorks P2000 G3 SAS MSA Dual Controller SFF Array System
Disk Enclosures
HP StorageWorks P2000 Dual I/O LFF Drive Enclosure, twelve 3.5" drive bays (w/ two .5m mini-SAS to mini-SAS cables. Used with single or dual controller LFF or SFF array head)
HP StorageWorks P2000 LFF Drive Enclosure I/O Module (no cable included. Designed exclusively for use with the LFF chassis AP838A to create a single I/O JBOD)
HP StorageWorks D2700 SFF Disk Enclosure, twenty-five 2.5" drive bays (w/ two .5m mini-SAS to mini-SAS cables. Used with single or dual controller LFF or SFF array head)
HP MSA 2040 Storage
HP MSA 2040 SAS Dual Controller LFF Storage HP MSA 2040 SAS Dual Controller SFF Storage
NOTE:
http://h18004.www1.hp.com/products/quickspecs/14603_div/14603_div.html
HP Smart Array P712m Controller
Will accept one or two controllers or Disk Enclosure I/O modules.
Will accept one or two controllers, not I/O modules.
Please see the supported MSA QuickSpecs for a list of compatible hard drives:
AW592A
AP838A
AP839A
AW593A AW594A
AP843A
AJ844A
AJ941A
C8S54A C8S55A
HP Tape Backup
Tape Autoloaders
HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader HP StorageWorks 1/8 G2 LTO-5 Ultrium 1760 SAS Tape Autoloader HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader
Tape Libraries
HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library HP StorageWorks MSL2024 1 LTO-5 Ultrium 3000 SAS Drive Library HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library HP StorageWorks MSL2048 1 LTO-5 Ultrium 3000 SAS Drive Library HP StorageWorks MSL8096 2 LTO-4 Ultrium 1760 SAS Drive Library
DA - 13296 Worldwide — Version 15 — November 8, 2013
AK377A
BL536A
AH558A
AK378A
AH559A
BL537A
AK380A
BL538A
AK382A
Page 9
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Related Options
HP StorageWorks MSL8096 2 LTO-5 Ultrium 3000 SAS Drive Library
NOTE:
transfer sizes. Attaching a library with 4 tape drives requires purchasing a second tape library SAS cable (AN975A or AN976A) and attaching 2 drives to the redundant 6Gb/s SAS BL Switch. Attaching more than 2 tape drives per switch and transfer sizes greater than 64K could result in a failed backup or restore. A future release of firmware on the tape library drives will allow more than 2 tape drives to be attached to a switch.
HP Smart Array P712m Controller
HP recommends a maximum of 2 tape drives per 6Gb/s SAS BL Switch and 64K
BL539A
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 10
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Technical Specifications
Dimensions Disk Drive and Enclosure
Protocol Support SAS Connectors Memory Bus Speed SAS Port Link Rate Software Upgradeable
Firmware Cache Memory
Logical Drives Supported Maximum Capacity Memory Addressing RAID Support
Upgradeable Firmware
4 in x 4.5 in x 0.8 in (10.1 cm x 11.4 cm x 2 cm) SAS protocol: 6Gb/s, 3Gb/s, or 1.5Gb/s SATA protocol: 3Gb/s or 1.5Gb/s two (2) 1x connectors for cabled drives, two (2) 2x connections for external connection to SAS switch DDR2-800MHz and 40-bit wide bus (256MB module) 6Gb/s per physical link Yes
256 MB Read/Write ECC protection and removable
Up to 2 logical drives internal, 512 logical drives external Variable depending upon enclosure 64-bit, supporting servers memory space greater than 4 GB Internal drives support RAID 0 (Striping) and RAID 1 (Mirroring)
RAID 0, 1, 3, 5, 6, 10, 50 on P2000sa Flashable ROM with redundant firmware images
HP Smart Array P712m Controller
Environment-friendly Products and Approach
© Copyright 2013 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.
End-of-life Management and Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to:
http://www.hp.com/go/green http://www.hp.com/go/green
Products returned to HP will be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.
http://www.hp.com/go/green
. To recycle your product, please go to: or contact your nearest HP sales office.
. These instructions may be
DA - 13296 Worldwide — Version 15 — November 8, 2013
Page 11
Loading...