![](/html/b4/b434/b43468768ec8bfb25158a83c28811f7f571324e23c00adfb9edaa91ad9e9063f/bg1.png)
Match Lit Fire Pit Insert
Installation & Operation Instructions
Select Models
Certified to
ANSI Z21.97-2014
CSA 2.41-2014
WARNING: FOR OUTDOOR USE ONLY
WARNING
•Improper installation, adjustment, alteration, service, or maintenance can cause injury or property
damage. Read the installation, operating, and maintenance instructions thoroughly before installing or
servicing this equipment.
WARNING
•Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other
appliance.
•An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
DANGER
If you smell gas:
1) Shut off gas to appliance.
2) Extinguish any open flame.
3) If odor continues, keep away from appliance and immediately call gas supplier or fire
department.
Installation
We suggest that our products be
installed by professionals that are
locally licensed by the authority
having jurisdiction in gas piping.
Service
We suggest that our products
be serviced by a professional
certified in the US by the
National Fireplace Institute
(NFI) as NFI Gas Specialists.
INSTALLER: Leave this
manual with the appliance.
CONSUMER: Retain this
manual for future reference.
6/05/2015 870
1
![](/html/b4/b434/b43468768ec8bfb25158a83c28811f7f571324e23c00adfb9edaa91ad9e9063f/bg2.png)
Index:
1) General Information
2) Selecting the Location
3) Construction of Enclosure
4) Installation of Fire Pit
5) Media
Product Specific Information
6) Parts List
7) Installation
8) Fire Pit Operation
9) Maintenance
10) Troubleshooting
11) Replacement Part
12) Warranty
1) General Information
Instructions are also available at HPCfire.com
Please carefully follow the instructions in this manual to prevent personal injury or property loss. Instructions are
updated as needed. It is the installer’s responsibility to periodically review instruction for applicable updates.
The steps listed as:
WARNINGS: Contains information critical to the safe installation and operation of the fire pit.
WARRANTY REQUIREMENT: Must be strictly followed to qualify for product warranty.
Warranty will be void if not followed.
IMPORTANT: Are notes and insights to help ensure product satisfaction and serviceability.
-------------------------------------------------------------------------------------------------------------------------------------------------
WARNING: It is the installer’s responsibility to ensure a safe installation and to educate the end user as to proper
operation. Leave this manual with the end user.
WARNING: Never alter product or configuration in any way.
WARNING: FOR REMOTE CONTROL USE: This family of product is not for use with any type of remote or start-up
timer control.
WARNING: We suggest that our products be installed by professionals that are locally licensed by the authority having
jurisdiction in gas piping. We suggest that our products be serviced annually by a professional certified in the US by the
National Fireplace Institute (NFI) as NFI Gas Specialists or in Canada by WETT (Wood Energy Technical Training).
Installer must follow all instructions carefully to ensure proper performance and safety. Hearth Products Controls
Company is not responsible for your actions.
WARNING: Product is not intended to be a starter for wood or any other combustibles.
WARNING: Product is not for use with small LP Tanks and must utilize permanent fixed piping for fuel supply.
WARNING: It is the responsibility of the installer to follow:
o The National Fuel Gas Code, ANSI Z223.1/NFPA 54 or International Fuel Gas Code.
o The National Electrical Code, ANSI/NFPA 70.
o Local Codes
WARNING: Only use gas/fuel type specified for this fire pit see label on the fire pit control Box. Verify correct
gas/fuel type and pressure. Never use an alternative fuel to include bio-fuel, ethanol, lighter fluid or any other fuel.
Gas pressure and type should be checked prior to use and installation.
● Natural Gas Fire Pit:
Supply Pressure: Minimum: 3.5” W.C.; Maximum: 7.0” W.C.
● LP Gas:
Supply Pressure: Minimum: 8.0” W.C.; Maximum: 11.0” W.C.
6/05/2015 870
2
![](/html/b4/b434/b43468768ec8bfb25158a83c28811f7f571324e23c00adfb9edaa91ad9e9063f/bg3.png)
2) Selecting the Location
WARNING: All fire pits, match lit kits, spark ignition, safety pilot and electronic ignition systems are designed and intended for
outdoor use only.
WARNING: All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for emergency shut off and
maintenance.
WARNING: Select a location where the fire pit can be attended during operation. Never leave an operating fire pit unattended or
by someone not familiar with its operation or emergency shut off locations.
WARNING: Both children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid
burns and clothing ignition.
WARNING: Young children should be carefully supervised when they are in the area of fire pit.
WARNING: Clothing or other flammable materials should not be placed on or near fire pit.
WARNING: Fire pits create very high temperatures - Combustibles must be located far enough away that there is no risk of
ignition.
IMPORTANT: It is recommended that material such as granite, marble or other dense stone be kept away from heat and
especially flame due to risk of cracking. Manufacturer is not responsible for damage.
Fire Pit Clearances – See Figure 1 On Last Page
Under Valve Box When Applicable For Drainage 2”
Sides Surrounding Fire Pit From Structure or Combustibles 36”
Overhead Clearance Above Product 84”
Select a location with good drainage and allows easy access for installation and maintenance of the fire pit.
Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe distance from the heat
and flame.
Up to 200k btu
3) Construction of the Enclosure
WARNING: All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for emergency shut off and
maintenance.
WARNING: Use non-combustible materials and construction for gas supply, power and enclosure. A metal outlet box should be
used inside the enclosure for electronic ignition models.
WARNING: The enclosure must incorporate 1 vent on at least two opposing sides (2 vents total) at a minimum size of 18 sq. inches
of total free area each (Example: 3”x 6” or larger). Installation of the vents in the mid to lower area of the enclosure is
recommended. Ventilation allows for heat and or residual fuel to escape. Failure to properly vent enclosure may result in the fire-
pit overheating or explosion. Some enclosures may require more ventilation based on material, size, and extended use. The vent
may work as a drain as well when installed at bottom sidewall to prevent water build up.
WARNING: The interior void space of the enclosure surrounding the valve box cannot be filled with any material (gravel, crushed
rock, concrete, etc.)- It is a requirement to have a minimum of 2” under the valve box for proper ventilation and drainage.
WARNING: The fire pit assembly should be recessed a minimum of 2.25” from the top of the enclosure to protect flame from
being blown out. Some areas may require more- 4 to 6” is not uncommon.
WARRANTY REQUIREMENT: The enclosure must be constructed on a stable surface. The weight of the fire pit must be
supported by the pan and not by any control/valve box. For electronic ignition models the control/valve box must be above grade
with adequate drainage to prevent water damage to the controls inside the box.
Make sure that the structure is level. We recommend the use of the installation collar (optional) that may be mortared
into the surround.
HPC recommends that the pan lip is recessed on trough (linear), and large round products as illustrated below. HPC
cannot guarantee the lip on all of our products will be perfectly flat and will not warp due to heat.
IMPORTANT: Product must be accessible for service.
6/05/2015 870
3