HEWLETT-PACKARD COMPANY MAKES NO WARRANTY
OF ANY KIND WITH REGARD TO THIS MATERIAL,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not
be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing,
performance, or use of this material.
The information contained herein is subject to change
without notice. The only warranties for HP products and
services are set forth in the express warranty statements
accompanying such products and services. Nothing herein
should be construed as constituting an additional warranty.
HP shall not be liable for technical or editorial errors or
omissions contained herein.
Hewlett-Packard assumes no responsibility for the use or
reliability of its software on equipment that is not furnished
by Hewlett-Packard.
Warranty
See the Customer Support/Warranty booklet included with
the product.
A copy of the specific warranty terms applicable to your
Hewlett-Packard products and replacement parts can be
obtained from your HP Sales and Service Office or
authorized dealer.
Hewlett-Packard Company
8000 Foothills Boulevard, m/s 5552
Roseville, California 95747-5552
http://www.procurve.com
Safety
Before installing and operating these products, please read
the “Installation Precautions” in chapter 2, “Installing the
Switch 4200vl Series”, and the safety statements in
appendix C, “Safety and EMC Regulatory Statements”.
The ProCurve Switch 4200vl Series are multiport modular switches that
provide Layer 3 routing features, and that feature low latency for high-speed
networking.
This chapter describes the Switch 4200vl Series including:
■front and back of the switches
■switch LED operation overview
■features
Switch 4200vl Options and Bundles
1
Introducing the ProCurve
Switch 4200vl Series
The Switch 4200vl is available in the following options:
■ProCurve Switch 4204vl (J8770A), a chassis with four open slots and
comes in one bundle:
•ProCurve Switch 4204vl-48GS (J9064A), consists of a J8770A Chassis
with two pre-installed ProCurve Switch vl modules. One 24-port
Gig-T module (J8768A) and one 20-port Gig-T plus 4-port mini-GBIC
or SFP module (J9033A).
■ProCurve Switch 4208vl (J8773A), a chassis with eight open slots and
comes in three bundles:
•ProCurve Switch 4208vl-64G (J8774A), consists of a J8773A chassis
with four pre-installed ProCurve Switch vl 16-port Gig-T Modules
(J8764A), providing 64 10/100/1000-T ports.
•ProCurve Switch 4208vl-96 (J8775A), consists of a J8773A chassis
with four pre-installed ProCurve Switch vl 24-port 10/100-TX Modules
(J8765A), providing 96 10/100-TX ports.
•ProCurve Switch 4208vl-72GS (J9030A), consists of a J8773A Chassis
with three pre-installed ProCurve Switch vl modules. Two 24-port
Gig-T modules (J8768A) and one 20-port Gig-T plus 4-port mini-GBIC
or SFP module (J9033A).
■ProCurve Switch 4202vl-48G (J8771A), a chassis with 48 fixed 10/100/
1000-T ports plus two open slots for vl modules.
■ProCurve Switch 4202vl-72 (J8772A), a chassis with 72 fixed 10/100-TX
ports plus two open slots for vl modules.
1-1
Page 10
Introducing the ProCurve Switch 4200vl Series
Switch 4200vl Options and Bundles
ProCurve
Switch 4204vl
J8770A
Power
Fault
Console
Self Test
ClearReset
Auxiliary Port
1 2 A BCD
Fan
Power
Status
Modules
Spd mode: off = 10 Mbps
flash = 100 Mbps
on = 1000 Mbps
SpdFDxAct
!
LED Mode
Use vl modules only
A
C
Serial No.
System MAC Address
SG12345678 00-01-e7- 12-34- 56
B
D
Switch 4200vl Series
Introducing the ProCurve
Figure 1-1. ProCurve Switch 4204vl (J8770A)
ProCurve
Switch 4208vl
J8773A
Power
Fault
Console
Self Test
ClearReset
Auxiliary Port
Status
1 2 A BCD E F G H
Fan
Power
ModulesLED Mode
Spd mode: off = 10 Mbps
flash = 100 Mbps
on = 1000 Mbps
SpdFDxAct
!
Use vl modules only
Serial No.
System MAC Address
SG12345678 00-01-e7- 12-34- 56
Figure 1-2. ProCurve Switch 4208vl (J8773A)
1-2
Page 11
Power
Fault
ProCurve
Switch 4202vl
J8772A
Console
Introducing the ProCurve Switch 4200vl Series
Switch 4200vl Options and Bundles
Introducing the ProCurve
Serial No.
Self Test
ClearReset
Auxiliary Port
Fan
Status
1 2 A B
Power
Modules
Use
vl Modules
only
Spd mode: off = 10 Mbps
flash = 100 Mbps
on = 1000 Mbps
FDx
Act
Spd
!
LED Mode
Mode
Link
1
3
Mode
Link
2
4
Mode
Link
25
27
7
5
6
29
31
10/100Base-TX Ports (1-72) all ports are HP Auto MDI-X
9
108
33
Mode
Link
13
11
Mode
Link
14
12
Mode
Link
35
37
15
17
16
18
41
39
System MAC Address
SG12345678 00-01-e7- 12-34- 56
21
19
22
20
43
45
23
24
47
Switch 4200vl Series
Power
Fault
ProCurve
Switch 4202v l
J8771A
Two slots for vl Modules
Figure 1-3. ProCurve Switch 4202vl-72 (J8772A)
Self Test
Console
ClearReset
Auxiliary Port
Fan
Status
1 2 A B
Power
Modules
Use
vl Modules
only
Spd mode: off = 10 Mbps
flash = 100 Mbps
on = 1000 Mbps
FDx
Act
Spd
!
LED Mode
Mode
Link
28
26
Link
49
Link
50
30
Mode
53
51
Mode
52
54
34
32
57
55
58
56
Mode
Link
38
36
Link
61
59
Link
62
60
42
40
Mode
65
63
Mode
66
64
46
44
67
68
48
69
71
72
70
72 fixed ports of 10/100-TX with
HP Auto MDI-X
Serial No.
System MAC Address
SG12345678 00-01-e7- 12-34- 56
Two slots for vl Modules
Figure 1-4. ProCurve Switch 4202vl-48G (J8771A)
48 fixed ports of 10/100/1000-T with
IEEE Auto MDI/MDI-X
1-3
Page 12
Introducing the ProCurve Switch 4200vl Series
Switch 4200vl Options and Bundles
Supported Modules:
As of this printing, the supported vl modules are:
•12-port 100-FX vl Module (J8763A)
•16-port 10/100/1000-T vl Module (J8764A)
•24-port 10/100-TX vl Module (J8765A)
•1-port 10-GbE vl Module (J8766A) -- into which you can install the
Switch 4200vl Series
Introducing the ProCurve
supported transceivers:
–ProCurve 10-GbE X2-SC SR Optic (J8436A)
–ProCurve 10-GbE X2-SC LR Optic (J8437A)
–ProCurve 10-GbE X2-SC ER Optic (J8438A)
–ProCurve 10-GbE X2 CX4 Xcvr (J8440B)
•24-port Gig-T vl module (J8768A)
•4-port mini-GBIC vl Module (J8776A) -- into which you can install the
supported mini-GBICs:
–the ProCurve Gigabit-SX-LC Mini-GBIC (J4858B)
–the ProCurve Gigabit-LX-LC Mini-GBIC (J4859B)
–the ProCurve Gigabit-LH-LC Mini-GBIC (J4860B)
–the ProCurve Gigabit 1000Base-T Mini-GBIC (J8177B)
This illustration shows the 4204vl, but the labeling and descriptions apply to
all of the ProCurve Switch 4200vl Series.
LEDs
As described in the next two tables, there are LEDs on the switch chassis and
on the switch modules/ports that keep you informed of the status of the switch
and the network connections.
1-5
Page 14
Introducing the ProCurve Switch 4200vl Series
Front of the Switch
Table 1-1.Switch Chassis LEDs
LEDsStateMeaning
Power
(green)
Fault
(orange)
Switch 4200vl Series
Introducing the ProCurve
OnThe switch is receiving power.
OffThe switch is NOT receiving power.
OffThe normal state; indicates that there are no fault conditions on the switch.
Flashing
1
A fault has occurred on the switch, one of the switch modules, an individual port, a power
supply, or a fan. The Status LED for the module or other component with the fault will flash
simultaneously.
OnOn briefly at the beginning of switch self test after the switch is powered on or reset. If on
for a prolonged time, the switch has encountered a fatal hardware failure, or has failed its
self test. See chapter 4, “Troubleshooting” for more information.
Self Test
(green)
OffThe normal operational state; the switch is not undergoing self test.
OnThe switch self test and initialization are in progress after you have power cycled or reset
the switch. The switch is not operational until this LED goes off. The Self Test LED also
comes on briefly when you “hot swap” a module into the switch and the module is
automatically self tested.
1
Flashing
A component of the switch has failed its self test. The Status LED for that component, for
example a switch module, and the switch Fault LED will flash simultaneously.
Status/Fan
(green)
OnThe cooling fans are operating normally.
Flashing
1
One or more of the cooling fans have failed. The switch Fault LED will be flashing
simultaneously.
Status/Power
(green numbers
corresponding
to the power
supply
positions)
Status/
Modules
(green - letters
corresponding
to the switch
module slots)
OnA power supply is installed in the position in the back of the switch corresponding to the
number, and the supply is plugged in to an active AC power source. As shipped, the switch
has a single power supply in position 1.
OffA power supply is not installed in the position corresponding to the number.
1
Flashing
The power supply installed in the position corresponding to the number is not plugged in
to an active AC power source, or has experienced a fault. The switch Fault LED will be
flashing simultaneously.
OnA module is installed in the switch module slot corresponding to the letter and the module
is undergoing or has passed self test. This also occurs when you install a module when
the switch is already powered on (“hot swap”).
OffA module is not installed in the switch module slot corresponding to the letter.
1
Flashing
The module status LED flashes very briefly when a module is being hot swapped. If the LED
flashes for a prolonged time, the module in the slot corresponding to the letter has failed
self test or encountered some other fault condition. See chapter 4, “Troubleshooting” for
a more information.
1-6
Page 15
Introducing the ProCurve Switch 4200vl Series
Front of the Switch
LEDsStateMeaning
LED Mode
Select
(3 green LEDs)
1
The flashing behavior is an on/off cycle once every 1.6 seconds, approximately.
ActIndicates the port Mode LEDs are displaying network activity information.
FDxIndicates the port Mode LEDs are lit for ports that are in Full Duplex Mode.
SpdIndicates the port Mode LEDs are displaying the connection speed at which each port is
operating:
• if the port Mode LED is off, the port is operating at 10 Mbps.
• if the port Mode LED is flashing, the port is operating at 100 Mbps.
• if the port Mode LED is on continuously, the port is operating at 1000 Mbps.
!
Indicates that specific error packets are being detected on the port. In this mode, the Mode
LED for the port will flash briefly for each error packet that is detected, for example CRC
errors or late collisions.
Table 1-2.Switch Module/Port LEDs
The following LEDs are located on the modules themselves or fixed ports
depending on which switch chassis you have, one pair for each port.
LEDStateMeaning
Link OnIndicates the port is enabled and receiving a link beat signal (for the twisted-pair
ports), or a strong enough light level (for the fiber-optic ports) from the connected
device.
Introducing the ProCurve
Switch 4200vl Series
OffOne of these conditions exists:
• no active network cable is connected to the port
• the port is not receiving link beat or sufficient light
• the port has been disabled through the switch console, the web browser
interface, ProCurve Manager, or other network management tool.
1
Flashing
Fast
Flashing
ModeDepending on the mode selected, displays the following: network activity information, whether
the port is configured for Full Duplex operation, port connection speed, or whether network
errors are occurring on the port. See “LED Mode Select Button and Indicator LEDs” below for
more information.
1
The flashing behavior is an on/off cycle once every 1.6 seconds, approximately.
2
The fast flashing behavior is an on/off cycle once every 0.8 seconds, approximately.
The port has failed self test due to hardware failure or because the port type
requires newer software in order to be recognized. The switch Fault, Self Test
LEDs, and appropriate module status LEDs will flash simultaneously. The Fault
LED will flash only for hardware failure.
Port security has disabled the port.
2
1-7
Page 16
Introducing the ProCurve Switch 4200vl Series
Front of the Switch
LED Mode Select Button and Indicator LEDs
To optimize the amount of information that can be displayed for each of the
switch ports, the Switch 4200vl Series use a Mode LED for each port. The
operation of this LED is controlled by the LED Mode Select button on the
switch chassis, and the current selection is indicated by the mode indicator
LEDs near the button. The default Mode LED position is Activity (Act). Press
the button to change from one mode to the next. After ten minutes, the Mode
Switch 4200vl Series
Introducing the ProCurve
button setting reverts back to the default setting. The Mode Select button and
LEDs are the same for all the Switch 4200vl Series. The following example is
of a J8772A, 4202vl-72.
Power
Fault
ProCurve
Switch 4202vl
J8772A
ProCurve
10/100-TX
vl Module
Console
Link ModeLink Mode
31
Link ModeLink Mode
J8765A
42
Self Test
ClearReset
10/1
5
6
Module Mode LEDs
(one for each port)
Figure 1-6. Mode Select and LEDs
■If the Activity (Act) indicator LED is lit, each port Mode LED displays
■If the Full Duplex (FDx) indicator LED is lit, the port Mode LEDs light for
■If the Speed (Spd) indicator LED is lit, the port LEDs behave as follows
■If the attention (!) indicator LED is lit, each Mode LED lights briefly for
Mode LEDs
(one for each port)
Mode
Link
13
11
12
35
36
59
60
15
Mode
Link
14
16
Mode
Link
39
37
Mode
Link
40
38
Mode
Link
61
63
Mode
Link
62
64
17
18
41
42
65
66
Serial No.
System MAC Address
SG12345678 00-01-e7- 12-34- 56
21
19
22
20
43
45
46
44
69
67
68
70
23
24
47
48
71
72
Auxiliary Port
00Base-TX P
1197
12108
Status
1 2 A B
Fan
Power
Modules
orts — all ports are HP A uto MDI-X
13
14
LED Mode Select button
and indicator LEDs
Spd mode: off = 10 Mbps
21
22
Act
LED Mode
FDx
flash = 100 Mbps
on = 1000 Mbps
Spd
!
23
24
Mode
Link
1
3
A
vl
Module
Mode
Link
2
4
Mode
Link
25
27
Mode
Link
28
26
Mode
Link
51
49
Mode
Link
52
50
Use
vl Modules
only
15
16
19
17
20
18
7
5
8
6
29
31
30
32
55
53
54
56
10/100Base-TX Ports (1-72) all ports are HP Auto MDI-X
9
10
33
34
57
58
activity information for the port—it flickers as network traffic is received
and transmitted through the port.
those ports that are operating in full duplex.
to indicate the connection speed for the port:
•Off = 10 Mbps
•Flashing = 100 Mbps
•On = 1000 Mbps
each network event that could require operator attention, for example,
late collisions or CRC errors.
1-8
Page 17
Introducing the ProCurve Switch 4200vl Series
Front of the Switch
Console Port
This port is used to connect a console to the switch by using the serial cable
supplied with the switch. This connection is described under “Connecting a
Console to the Switch” in chapter 2, “Installing the Switch 4200vl Series”. The
console is a full-featured interface that can be used to configure, monitor, and
troubleshoot the switch. It can be run on a PC, laptop, or handheld device
emulating a VT-100 terminal, or on a standard VT-100 terminal.
Reset Button
This button is used to reset the switch while it is powered on. This action clears
any temporary error conditions that may have occurred, executes the switch
self test, and resets all network activity counters to zero. The counters are
displayed in the switch console interface, the switch web browser interface,
and through SNMP network management applications, such as ProCurve
Manager.
Press the Reset button also after changing the module type that is installed in
any of the switch module slots while the switch is powered on. In this case,
the switch must be reset to initialize the new module type. See “Hot Swapping
Switch Modules” on page 2-22.
Introducing the ProCurve
Switch 4200vl Series
Clear Button
This button is used for the following purposes:
■Deleting Passwords - When pressed by itself for at least one second, the
Clear button deletes any switch console access passwords that you may
have configured. Use this feature if you have misplaced the password and
need console access.
This button is provided for your convenience, but its presence means that
if you are concerned with the security of the switch configuration and
operation, you should make sure the switch is installed in a secure
location, such as a locked wiring closet.
■Restoring Factory Default Configuration - When pressed with the
Reset button in a specific pattern, the Clear button clears any configuration changes you may have made through the switch console, the web
browser interface, or SNMP management, and restores the factory default
configuration to the switch. For the specific method to restore the factory
default configuration, see “Restoring the Factory Default Configuration”
in chapter 4, “Troubleshooting” of this manual.
1-9
Page 18
Introducing the ProCurve Switch 4200vl Series
Back of the Switch
Back of the Switch
.
AC power connector
Switch 4200vl Series
Introducing the ProCurve
Figure 1-7. Example showing back of Switch 4208vl (J8773A)
slot for installing optional
redundant power supply
Power Connector
The Switch 4200vl Series do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.
Slot for Redundant Power Supply
A second, load-sharing redundant power supply (ProCurve switch RPS,
J4839A) can be installed in the back of the Switch 4200vl Series. To provide
true redundancy, this second power supply should be connected to a different
AC power source from the other supply. Then, if one AC power source fails,
the switch will continue to run.
CautionThe switch redundant power supply is hot swappable, but, as indicated by the
caution statement on the power supply, it must be disconnected from AC
power before being installed or removed.
Caution:
.
Refer to the installation guide for proper power cord selection.
.
Disconnect AC power from this power supply BEFORE installing or removing
the supply. Otherwise, damage to the equipment may result.
Because the switch can run on a single supply, removing a redundant supply
will not interrupt switch operation.
1-10
Page 19
Introducing the ProCurve Switch 4200vl Series
Switch Features
Switch Features
The features of the Switch 4200vl Series include:
■2, 4 or 8 slots for installing any of the available Switch vl Modules.
the modules can be installed in any order and in any combination and can
be “hot swapped”.
■the supported mini-GBICs can be hot swapped into the mini-GBIC vl
Module.
■the supported transceivers can be hot swapped into the 10-GbE vl Module.
■plug-and-play networking—all ports are enabled—just connect the
network cables to active network devices and your switched network is
operational.
■automatic learning of the network addresses in the switch’s 10,000-
address forwarding table, with configurable address aging value.
■full-duplex operation available on all ports.
■easy management of the switch through several available interfaces:
•web browser interface—an easy to use built-in graphical interface
that can be accessed from common web browsers.
•console interface—a full featured, easy to use, VT-100 terminal interface for switch management, accessible out-of-band and by telnet.
The console includes complete switch management through a
command line interface (CLI) with the most basic configuration
parameters also accessible through an intuitive menu interface.
•ProCurve Manager—an SNMP-based graphical interface that is used
to manage your entire network, included with your new switch.
•supported by HP OpenView ProCurve Network Manager—an HP
OpenView application that accurately displays your switch on
network maps and provides a graphical interface for configuring and
monitoring your switch.
■support for the Spanning Tree Protocol to eliminate network loops.
■support for up to 256 IEEE 802.1Q-compliant VLANs so you can divide the
attached end nodes into logical groupings that fit your business needs.
Introducing the ProCurve
Switch 4200vl Series
1-11
Page 20
Introducing the ProCurve Switch 4200vl Series
Switch Features
■Layer 3 routing functionality:
•IP static routes
•IRDP
•DHCP relay
■support for many other advanced features to enhance network perfor-
mance, security, and control— for a description, see the Management and
Configuration Guide and the Advanced Traffic Management Guide for
Switch 4200vl Series
your switch, available on the ProCurve Web site.
Introducing the ProCurve
1-12
Page 21
Installing the Switch 4200vl Series
The ProCurve Switch 4200vl Series are easily installed. They come with an
accessory kit that includes the brackets for mounting the switch in a standard
19-inch telco rack, in an equipment cabinet, or on a wall. The switches have
rubber feet already attached so they can be securely located on a horizontal
surface. This chapter shows you how to install your Switch 4200vl Series.
Included Parts
The Switch 4200vl Series have the following components shipped with them:
■ProCurve Switch 4200vl Series Installation and Getting Started Guide,
this manual
2
Installing the Switch 4200vl
Series
■ProCurve Manager - CD ROM and booklet
■Customer Support/Warranty booklet
■Accessory kit 5065-6521 for the:
•8-slot Switch 4208vl
•Switch 4208vl-64G
•Switch 4208vl-96
•Switch 4208vl-72GS
■Accessory kit 5064-9943 for the:
•4-slot Switch 4204vl
•Switch 4202vl-48G
•Switch 4202vl-72
•Switch 4204vl-48GS
■Each kit contains:
•two mounting brackets
•six 10 mm M4 screws to attach the mounting brackets to the switch
•four 5/8-inch number 12-24 screws to attach the switch to a rack
■Console cable
2-1
Page 22
Installing the Switch 4200vl Series
Included Parts
■Power cord, one of the following:
Series
Installing the Switch 4200vl
Japan Power
Cord Warning
Australia/New Zealand
China
Continental Europe
Denmark
Japan
8120-6803
8120-8377
8120-6802
8120-6806
8121-0606
Switzerland
United Kingdom/
Hong Kong/Singapore
United States/Canada/Mexico
8120-6807
8120-8709
8121-0605
2-2
Page 23
Installing the Switch 4200vl Series
Installation Procedures
Installation Procedures
Summary
Follow these easy steps to install your switch. The rest of this chapter provides
details on these steps.
1.Prepare the installation site (page 2-6). Make sure the physical environment into which you will be installing the switch is properly prepared
including having the correct network cabling ready to connect to the
switch, and having a good location for the switch. See page 2-4 for some
installation precautions.
2.Install switch modules (page 2-8). The Switch 4200vl Series have two,
four or eight universal slots for installing any of the ProCurve Switch vl
modules. Depending on where you will install your Series 4200vl Switch,
it may be easier to install the modules first. The modules are “hot swappable” though, so they can also be installed and removed after the switch
is powered on.
Installing the Switch 4200vl
Series
NoteMake sure you use only ProCurve Switch vl Modules in your Switch 4200vl
Series.
3.(Optional) Install second power supply (page 2-10). The Switch
4200vl Series have a slot in the back for installing a second, load-sharing
power supply. If you have purchased this supply, it may be easier to install
it before mounting the switch.
4.Verify the switch passes self test (page 2-12). This is a simple process
of plugging the switch into a power source and observing that the LEDs
on the switch’s front panel and on the modules show correct operation.
5.Mount the switch (page 2-14). The Switch 4200vl Series can be mounted
in a 19-inch telco rack, in an equipment cabinet, on a wall, or on a
horizontal surface. There are some limitations to the wall mounting
orientations that are supported. Please see the installation details for
more information.
6.Connect power to the switch (page 2-19). Once the switch is mounted,
plug it in to the nearby main power source.
7.Connect the network devices (page 2-19). Using the appropriate
network cables, connect other switches, hubs, routers, computers,
servers, printers, and other network devices to the switch ports. For more
information, see “Connect the Network Devices” on page 2-19.
2-3
Page 24
Installing the Switch 4200vl Series
Installation Procedures
NoteThe 10/100Base-TX ports on the10/100-TX vl Module have the HP Auto
MDI-X feature, and the 10/100/1000Base-T ports on the Gig-T vl Module comply with IEEE 802.3ab standard which includes the Auto MDI/MDIX feature. These two features operate the same and allow you to use
straight-through twisted-pair cable for all of your twisted-pair network
connections.
8.(Optional) Connect a console to the switch (page 2-20). You may
wish to modify the switch’s configuration, for example, to configure an IP
address so it can be managed using a web browser or from an SNMP
network management station. Configuration changes can be made easily
through the switch’s console interface.
At this point, the switch is fully installed. See the rest of this chapter if you
need more detailed information on any of these installation steps.
Installation Precautions
Series
Installing the Switch 4200vl
WARNINGS
Follow these precautions when installing the ProCurve Series 4200vl Switch:
■Devices installed in a rack or cabinet should be mounted as low
as possible, with the heaviest device at the bottom and progressively lighter devices installed above.
The rack or cabinet should be adequately secured to prevent it
from becoming unstable and/or falling over.
■Ensure a cover plate is installed in any empty switch power
supply slot. A cover plate is required for safe operation, and
to ensure proper switch cooling.
■To avoid energy and mechanical hazards, never allow any part
of your body, jewelry, tool, or other foreign object to enter any
module or power supply slots.
■Ensure that for any switch slot into which no module is
installed, the cover plate is installed to cover the slot. A cover
plate is required for safe operation, and to ensure proper
switch cooling. For safety, you should never have more than
one module slot uncovered at a time while the switch is
powered on.
2-4
Page 25
Installing the Switch 4200vl Series
Installation Precautions (continued)
Installation Procedures
Cautions
■Ensure the power source circuits are properly grounded, then use the
power cord supplied with the switch to connect it to the power source.
If your installation requires a different power cord than the one supplied
with the switch and power supply, be sure the cord is adequately sized
for the switch’s current requirements. In addition, be sure to use a power
cord displaying the mark of the safety agency that defines the regulations
for power cords in your country. The mark is your assurance that the
power cord can be used safely with the switch and power supply.
■When installing the switch, note that the AC outlet should be near the
switch and should be easily accessible in case the switch must be
powered off.
■Ensure the switch does not overload the power circuits, wiring, and over-
current protection. To determine the possibility of overloading the supply
circuits, add together the ampere ratings of all devices installed on the
same circuit as the switch and compare the total with the rating limit for
the circuit. The maximum ampere ratings are usually printed on the
devices near the AC power connectors.
■Do not install the switch in an environment where the operating ambient
temperature might exceed 40°C (104°F).
Installing the Switch 4200vl
Series
■Allow three to four inches of space around the sides and back of the
switch to make sure the air flow for the switch is not restricted.
2-5
Page 26
Installing the Switch 4200vl Series
Installation Procedures
1. Prepare the Installation Site
Cabling Infrastructure
Ensure the cabling infrastructure meets the necessary network specifications.
See the following table for cable types and lengths, and see appendix B,
“Switch Ports and Network Cables” on page B-1 for more information:
Table 2-1.Summary of Cable Types to Use with the Switch
Port TypeCable TypeLength Limits
Twisted-Pair Cables
Series
Installing the Switch 4200vl
10/100/1000Base-TFor either 10, 100 Mbps or 1000 Mbps
operation:
Category 5 or better, 100-ohm UTP or shielded
twisted-pair (STP) balanced cable. For 1000
Mbps (gigabit) operation, Category 5e cabling
or better is recommended.
Fiber Optic Cables
Gigabit-SX
(on Gigabit-SX-LC
mini-GBIC)
Gigabit-LX
(on Gigabit-LX-LC
mini-GBIC)
Multimode fiber-optic cables fitted with LC
connectors
Single-mode fiber-optic cables fitted with LC
connectors.
The multimode cables specified for the GigabitSX mini-GBIC may also be used, but a modeconditioning patch cord may be needed — See
the Installation Guide that came with your
module for more information.
100 meters
Note: The ProCurve Gig-T vl Modules are
compatible with the IEEE 802.3ab standard
including the “Auto MDI/MDI-X” feature,
which allows use of either straight-through
or crossover twisted-pair cables for
connecting to any network devices
including end nodes, such as computers, or
to other switches, hubs, and routers.
The Auto MDI/MDI-X feature only works
when the port is in auto-negotiation mode.
220 meters to 550 meters depending on the
cable used. See “Fiber-Optic Cables” on
page B-3 for more information.
• single-mode cable = 10 kilometers
• multimode cable = 550 meters
Gigabit-LH
(on Gigabit-LH-LC
mini-GBIC)
Note:
Gigabit-LH - The transmission distances are dependent on the particular fiber loss and coupling loss involved, among
other factors, and can be estimated from the optical loss budget. For distances less than 20km, a 10dB attenuator must
be used. For distances between 20km and 40km, a 5dB attenuator must be used. Attenuators can be purchased from
most cable vendors.
The same single-mode fiber-optic cables a s for
Gigabit-LX.
2-6
• 70 kilometers
Page 27
Installing the Switch 4200vl Series
Port TypeCable TypeLength Limits
Installation Procedures
10-GbE SRMultimode fiber-optic cable designed for
Gigabit Ethernet: 62.5/125 μm (core/cladding)
diameter or 50/125 μm, low metal content,
complying with the ITU-T G.652 and ISO/IEC
793-2 Type B1 standards.
10-GbE LR9/125 μm (core/cladding) diameter, low metal
content, single mode fiber-optic cables,
complying with the ITU-T G.652 and ISO/IEC
793-2 Type B1 standards.
10-GbE ER9/125 μm (core/cladding) diameter, low metal
content, single mode fiber-optic cables,
complying with the ITU-T G.652 and ISO/IEC
793-2 Type B1 standards.
kilometers, on an engineered fiber optic link
that meets standards in the specification).
50 μm cable or 62.5 μm cable: 300 meters
Installing the Switch 4200vl
Series
Port TypeCable SpecificationsConnector Type
CX4Shielded twisted-pair cables complying with
the 802.3ak standard.
Installation Location
Before installing the switch, plan its location and orientation relative to other
devices and equipment:
■In the front of the switch, allow at least 7.6 cm (3 inches) of space for the
twisted-pair and fiber-optic cabling.
■In the back of the switch, allow at least 10.2 cm (4 inches) of space for the
power cord and cooling.
■On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling.
CX4
2-7
Page 28
Installing the Switch 4200vl Series
Installation Procedures
2. Install Switch vl Modules
Install switch modules into the slots as shown in the following illustration. For
installation details, see the instructions in the manual that comes with the
module.
CautionMake sure you install only ProCurve Switch vl Modules. Switch gl/xl Modules
will fit into your Switch vl slots, but they will not operate.
Avoid any electrostatic discharge problems by handling the modules only by
their bulkheads.
The slot cover can be removed, and the module can be installed with either a
flat-bladed or Torx T-10 screwdriver. Retain the slot cover for future use.
Series
Installing the Switch 4200vl
Module
Installation
Notes
■Any of the supported Switch vl Modules can be installed in any of the slots.
■You can install, exchange, or remove modules after the switch has been
powered on. Whenever a module is installed during this process, it is
initialized and tested for correct operation. During this process, the switch
Self Test LED is on. If you hot swap another module while the switch is
initializing and testing the first module, it is possible to cause the first
module or the entire switch to be reset. To prevent the modules or switch
from being reset when you must hot swap multiple modules, follow these
precautions:
•Do not install/remove any modules from the switch while the switch
Self Test LED is lit.
•Before removing or installing any modules, make sure that all
network cables are disconnected from the module.
See “Hot Swapping the Switch Module” on page 2-22.
■The modules employ “low-force” connectors. Using high force to insert
the modules is not needed and should not be used.
■Ensure you fully insert the modules. That is, press the module into the slot
until the bulkhead on the module is contacting or is very close to
contacting the front face of the switch chassis.
■Once the module is fully inserted, ensure that you screw in the two
retaining screws to secure the module in place. The screws should be
tightened until they are secure, but not overtightened.
■If you do not use one or more of the slots, ensure the slot cover plate is
still attached over the slot for safe operation and proper switch cooling.
For safety, you should not have more than one module slot uncovered at
a time.
2-8
Page 29
insert module into the
guides and slide it in until
it is fully inserted
Installing the Switch 4200vl Series
Installation Procedures
“Low-force” connector.
High insertion force is not
needed and should not be used
Installing the Switch 4200vl
Series
for best results,
push near both screws
Figure 2-1. Installing a module
the module is fully inserted when
the module bulkhead is contacting,
or very close to contacting
the face of the switch
tighten the retaining screws on
the module until they are secure,
but do not overtighten them
Figure 2-2. Tighten module retaining screws
2-9
Page 30
Series
Installing the Switch 4200vl Series
Installation Procedures
3. (Optional) Install Second Power Supply
A second, load-sharing redundant power supply (ProCurve Switch gl/xl/vl
RPS, J4839A) can be installed in the back of the switch. To provide true
redundancy, this second power supply should be connected to a different AC
power source from the other supply. Then, if one AC power source fails, the
switch will continue to run. Each supply provides enough power to operate a
fully loaded switch, so even if one fails, the switch will continue to operate
normally.
Install the second power supply as shown in the illustration on the next page.
The slot cover can be removed with either a flat-bladed or Torx T-10 screwdriver. Retain the slot cover for future use.
CautionThe switch power supplies are hot swappable; they can be installed while the
switch is receiving power from the supply in the other slot. But, as indicated
by the caution statement on the power supply, the supply must not be connected to AC power before being installed.
Installing the Switch 4200vl
Caution:
.
Refer to the installation guide for proper power cord selection.
.
Disconnect AC power from this power supply BEFORE installing or removing
the supply. Otherwise, damage to the equipment may result.
For safety and proper switch cooling, if either of the power supply slots are
not being used, make sure to attach the cover plate over the slot. Please see
the “Installation Precautions” on page 2-4 for more information.
For installation details, see the instructions in the manual that comes with the
power supply.
2-10
Page 31
Insert the power supply into
the openin g, then slide it all the
way in until it connects to the
switch. Th e power supply face
plate will be flush with the
back face of the switch.
Installing the Switch 4200vl Series
Installation Procedures
Installing the Switch 4200vl
Series
Figure 2-3. Installing a power supply
Once the power supply is installed, ensure you tighten the four retaining
screws that hold it in place. The screws can be tightened with either a flatbladed or Torx T-10 screwdriver. Be careful to not overtighten the screws.
tighten the four screws
Figure 2-4. Tighten power supply retaining screws
2-11
Page 32
Series
Installing the Switch 4200vl Series
Installation Procedures
4. Verify the Switch Passes Self Test
After you have installed any modules and the optional second power supply,
but before mounting the switch in its network location, you should first verify
it is working properly by plugging it into a power source and verifying it passes
its self test.
If you have installed a second power supply, repeat these procedures with the
second power supply to verify it works correctly also.
1.Connect the power cord supplied with the switch to the power connector
on the back of the switch, and then into a properly grounded electrical
outlet.
Installing the Switch 4200vl
connect power co rd
to power connector
Figure 2-5. Connecting power to the Switch
NoteThe Switch 4200vl Series do not have a power switch. They are powered on
when the power cord is connected to the switch and to a power source.
If your installation requires a different power cord than the one supplied with
the switch, please see the “Installation Precautions” on page 2-5.
2.Check the LEDs on the switch and on each of the switch modules. The
LED behavior is described on the next page.
If the LED display is different than what is described, especially if the
Fault LED stays on for more than approximately 120 seconds or it starts
flashing, the self test has not completed correctly. Refer to chapter 4,
“Troubleshooting” for diagnostic help.
2-12
Page 33
Installing the Switch 4200vl Series
n
switch chassis LEDs
Installation Procedures
switch module
LEDs: Link and
Mode LEDs for each
port
19
20
Spd mode: off = 10 Mbps
flash = 100 Mbps
on = 1000 Mbps
SpdFDxAct
LED Mode
23
21
24
!
Module
A
A
vl
Use vl modules o
Power
Fault
ProCurve
Switch 4204vl
J8770A
Console
Link ModeLink Mode
31
5
ProCurve
10/100-TX
vl Module
Link ModeLink Mode
J8765A
6
42
Self Test
ClearReset
10/1
Auxiliary Port
00Base-TX P
orts — all ports are HP A uto MDI-X
1197
12108
Status
1 2 A BCD
Fan
Power
13
14
Modules
15
17
16
18
Figure 2-6. Switch LEDs
When the switch is powered on, it performs its diagnostic self test. The entire
download, initialization, and self test process can take up to 2 minutes for a
fully loaded chassis, depending on the number and type of modules installed
in the switch.
LED Behavior:
During the self test:
■Initially, Power and Fault, and all the switch chassis LEDs are on. Then,
after approximately 30 seconds, all the module LEDs go on as the modules
receive power and code is downloaded to them, the Fault LED goes off,
and the chassis LEDs go off except Power, Self Test, Fan Status, and Power
Status.
Installing the Switch 4200vl
Series
■When the download of code to the modules is completed, the module
LEDs go off. You may see each port LED go on briefly, in sequence, as the
port is tested.
■For the duration of the self test, the Self Test LED stays on.
When the self test completes successfully:
■The Power LED stays on, and the Status LEDs on the switch chassis stay
on for the devices installed: one for each switch module installed, one for
each power supply installed, and one for all the fans.
■The Fault and Self Test LEDs are off.
■The port LEDs on the switch modules go into their normal operational
mode:
•If the ports are connected to active network devices, the Link LEDs
stay on and the Mode LEDs behave according to the mode selected.
In the default mode (Activity), the Mode LEDs should flicker showing
network activity on the port.
•If the ports are not connected to active network devices, the LEDs
will stay off.
2-13
Page 34
Installing the Switch 4200vl Series
Installation Procedures
5. Mount the Switch
After the modules and optional power supply are installed and you have
verified the switch passes self test, you are ready to mount the switch in a
stable location. The Switch 4200vl Series can be mounted in these ways:
■in a rack or cabinet
■on a horizontal surface
■on a wall
Rack or Cabinet Mounting
The Switch 4200vl Series are designed to be mounted in any EIA-standard 19inch telco rack or in an equipment cabinet such as a server cabinet. If you are
installing the switch in an equipment cabinet, please see the “Equipment
Cabinet Note” on page 2-17.
Series
Installing the Switch 4200vl
CautionFor safe operation, please read the “Installation Precautions” on page 2-5
before mounting the switch.
1.Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 10-mm M4 screws.
For the Switch 4204vl, 4202vl-48G, and 4202vl-72, each bracket is attached
with two screws, and for the Switch 4208vl and its bundles each bracket
is attached with three screws as shown in the illustrations on the next
page.
2-14
Page 35
10 mm
M4 screws
Installing the Switch 4200vl Series
Installation Procedures
Installing the Switch 4200vl
Series
10 mm
M4 screws
Figure 2-7. Attaching brackets to a 3U chassis
Figure 2-8. Attaching brackets to a 5U chassis
2-15
Page 36
Series
Installing the Switch 4200vl Series
Installation Procedures
2.Partially install a screw (5/8-inch number 12-24) into the top hole of a pair
of holes that are 0.5 inches apart in each rack/cabinet upright as shown
in the illustration below. Ensure that the screws are at the same level in
each upright.
.
partially install a screw
into the top hole of a
close (0.5-inch) pair on
both sides of the rack
Installing the Switch 4200vl
Figure 2-9. Installing the Rack Screw
3.Place the switch in the rack and lower it so the notches in the bottom of
the bracket slide onto the screws, then tighten these screws.
lower the switch with
mounting brackets onto the
partially installed screws,
then tighten these screws
Figure 2-10. Rack mounting using the bracket notch
2-16
Page 37
install and tighten the
other 12-24 screws
Installing the Switch 4200vl Series
Installation Procedures
4.Install the other number 12-24 screw into the upper hole in each bracket.
Tighten these screws.
Installing the Switch 4200vl
Series
Figure 2-11. Installing final rack mounting screws
Equipment
Cabinet
Note
If you are installing the switch in an equipment cabinet, in place of the
12-24 screws supplied with the switch, use the clips and screws that came with
the cabinet. Plan which four holes you will be using in the cabinet and install
all four clips and partially install the two bottom screws, as described in step
2 on the previous page, before proceeding to step 3.
Horizontal Surface Mounting
Place the switch on a table or other horizontal surface. Use a sturdy surface
in an uncluttered area. You may want to secure the networking cables and
switch power cord to the table legs or other part of the surface structure to
help prevent people from tripping over the cords.
NoteEnsure the air flow is not restricted around the sides and back of the switch.
2-17
Page 38
Series
Installing the Switch 4200vl
Installing the Switch 4200vl Series
Installation Procedures
Wall Mounting
The mounting brackets supplied with the switch allow you to mount it on a
wall. The illustrations below show mounting a Switch 4208vl. All other 4200vl
Switches would be mounted in a similar way.
CautionFor safe operation, do not install the switch with the vents or fans facing
downward. The only recommended and supported wall mounting orientation
is with the unit upright and the modules facing out, as shown in the illustrations below.
Additionally, the switch should be mounted only to a wall or wood surface
that is at least 1/2-inch plywood or its equivalent.
1.Use a #1 Phillips
(cross-head)
screwdriver and
attach the
mounting brackets
to the switch with
the included
10-mm M4 screws.
10 mm
M4 screws
Figure 2-12. Install mounting bracket screws
2.Attach the
switch to the
wall or wood
surface with four
5/8-inch number
12 wood screws
or larger (not
included).
Figure 2-13. Installing wood screws for wall mounting
5/8-inch number
12 wood screws
2-18
Page 39
Installing the Switch 4200vl Series
Installation Procedures
6. Connect the Switch to a Power Source
1.Plug the included power cord into the switch’s power connector and into
a nearby properly grounded AC power source.
If you have installed a redundant power supply module into the switch, it
should be connected to a separate AC power source. Then, if there is a
power outage from one of the AC sources, the switch will continue to
operate by power coming from the other source.
See the ProCurve Switch gl/xl/vl RPS Installation Guide for additional
information.
2.Re-check the LEDs during self test. See “LED Behavior” on page 2-13.
7. Connect the Network Devices
The type of network connections you will need to use depends on the types
of switch modules you have installed in your Series 4200vl Switch. See the
documentation accompanying the modules for cabling configurations and
procedures for those modules.
In general for all the modules, when a network cable from an active network
device is connected to the switch, the Link LED for the switch port should go
on. If the Link LED does not go on, use the table below to help solve the
problem, and see the module documentation for troubleshooting procedures.
ConditionDiagnostic Tip
Port LED is
still off when
a cable is
connected
Try the following procedures:
• For the indicated port, verify both ends of the cabling, at the switch and the connected device, are
securely connected.
• Verify the connected device and switch are both powered on and operating correctly.
• Verify you have used the correct cable type for the connection:
– for all twisted-pair connections, the RJ-45 connectors on the Switch 4200vl Series allow you
to use either straight-through cable or crossover cable when the port is in the “Auto”
configuration.
– for fiber-optic connections, verify the transmit port on the switch is connected to
the receive port on the connected device, and the switch receive port is connected to
the transmit port on the connected device.
See appendix B, “Switch Ports and Network Cables” for information on cables.
• Verify the port has not been disabled through a switch configuration change.
• Verify the connection parameters in the configurations of the switch port and the connected
device match. Mismatched configurations are a frequent cause of connection problems.
You can use the console interface, or, if you have configured an IP address on the switch, use
Telnet, the web browser interface, or ProCurve Manager network management software to
determine the state and configuration of the port and re-enable the port if necessary.
• If the other procedures don’t resolve the problem, try using a different port or a different cable.
Installing the Switch 4200vl
Series
2-19
Page 40
Series
Installing the Switch 4200vl Series
Installation Procedures
8. (Optional) Connect a Console to the Switch
The Switch 4200vl Series have a full-featured, easy to use console interface
for performing the following tasks:
■Monitor switch and port status and observe network activity counters
■Modify the switch’s configuration
■Read the event log and access diagnostic tools to help in troubleshooting
■Download new software to the switch
■Add passwords and other security features to control access to the switch
from the console, web browser interface, and network management
stations
The console can be accessed through these methods:
■Out-of-band: Connect a PC or VT-100 terminal, to be used as a console,
directly to the switch using the serial cable that comes with the Switch
4200vl Series. If the PC or terminal has a 25-pin serial connector, you can
use a readily available 9-pin to 25-pin serial cable, or attach a 9-to-25 pin
straight-through adapter to the PC end of the cable.
Installing the Switch 4200vl
■In-Band: Access the console using telnet from a PC or UNIX station on
the network, and a VT-100 terminal emulator. This method requires that
you first configure the switch with an IP address and subnet mask by using
either out-of-band console access or through DHCP/Bootp.
The Switch 4200vl Series can simultaneously support one out-of-band console
session through the Console Port and three in-band telnet sessions.
Terminal Configuration
To connect a console to the switch, configure the PC terminal emulator as a
VT-100 or DEC VT-100 (ANSI) terminal, or use a VT-100 terminal and configure
it to operate with these settings:
■any baud rate from 2400 to 115200 (the switch automatically senses the
speed)
■8 data bits, 1 stop bit, no parity, and flow control set to None
■for Windows Terminal program, also disable (uncheck) the “Use Function,
Arrow, and Ctrl
■for the Hilgrave HyperTerminal program, select the “Terminal keys”
option for the “Function, arrow, and ctrl keys act as” parameter
Keys for Windows” option
2-20
Page 41
Installing the Switch 4200vl Series
e
a
2
a
Installation Procedures
If you want to operate the console using a different configuration, ensure you
change the settings on both the terminal and on the switch. Change the switch
settings first, then change the terminal settings, and reestablish the console
session.
Direct Console Access
To connect a console to the
switch, follow these steps:
console port
1.Connect the PC or
terminal to the switch’s
Console Port using the
console cable included
ProCurve
Switch 4202 vl
J8772A
Power
Fault
Console
Link ModeLink
ProCurve
10/100-T
vlModule
Link ModeLink
J8765A
SelfT es t
St
Fan
Auxiliar y Port
10/1 00Base-TX Por ts — all ports
11975
12108642
1
Pow
Installing the Switch 4200vl
ClearReset
31
with the switch. (If your
PC or terminal has a 25-
Series
pin serial connector, first
attach a 9-pin to 25-pin
straight-through adapter
to the PC end of the
console cable.)
console cable supplied
with the switch
2.Turn on the terminal or
PC’s power and, if using a
PC, start the PC terminal
program.
3.Press the Enter key two
PC running a terminal
emulator program, or
a VT-100 terminal
or three times and you
will see the copyright
page and the message
“Press any key to
Figure 2-14. Connecting the console port
continue”. Press a key,
and you will then see the
switch console CLI prompt.
Telnet Console Access
To access the switch through a telnet session, follow these steps:
1.Ensure the switch is configured with an IP address and that the switch is
reachable from the telnet workstation (for example by using a Ping
command to the switch’s IP address)
2.Start the telnet program and connect to the switch’s IP address.
3.You will see the copyright page and the message “Press any key to
continue”. Press a key, and you will then see the switch console CLI
prompt.
2-21
Page 42
Series
Installing the Switch 4200vl Series
Hot Swapping Switch Modules
If you want to continue with console management of the switch at this time
through either a direct connection or a telnet session, see chapter 3, “Getting
Started With Switch Configuration” for some basic configuration steps. For
more detailed information, refer to the Management and Configuration Guide, for your switch, available on the ProCurve Web site.
Hot Swapping Switch Modules
The switch modules can be “hot swapped”, that is installed or replaced while
the switch is powered on (see Module Installation Notes on page 2-8). The
procedures differ slightly, though, between adding new modules to an empty
slot or replacing modules with the same type, and exchanging the module with
a different type.
Adding or Replacing Modules
Installing the Switch 4200vl
If a module has to be replaced with one of the same type, or you are expanding
the switch capability by adding a module in a slot where one was not previously installed (since the last switch reboot), the replaced or new module is
immediately operational; there is no interruption to the switch operation.
Changing the Module Type
If you exchange a module with a different type of module though, for example
a Gig-T vl Module is installed in place of a 10/100-TX vl Module that was in the
slot, the switch must be rebooted after the new module is installed so the
switch processor can properly initialize and configure the new module type.
You can reboot the switch by any of the following methods:
■Pressing the Reset button on the front of the switch.
■Unplugging and plugging in the power cord (power cycle). If two power
supplies are installed, both power cords would have to be unplugged.
■Issuing the reload command from the switch console CLI, or selecting the
Reboot Switch option from the switch console menu, the web browser
interface, or ProCurve Manager.
Until the switch is rebooted, the module will not operate and the Module
Status LED for the affected slot will continue to flash.
2-22
Page 43
Example Network Topologies
This section shows you a few example network topologies in which the Switch
4200vl Series can be implemented. For more topology information, see the
ProCurve Web site, www.procurve.com.
Basic Connectivity
server connected
by a Gigabit link
Installing the Switch 4200vl Series
Example Network Topologies
Installing the Switch 4200vl
switch 4202vl-72
twisted-pair
straight-through
or crossover
cables
B
PCs and
peripherals
Figure 2-15. Basic Topology
The Switch 4200vl Series can provide basic network connectivity to a high
number of users. End nodes, printers and other peripherals, and servers can
be easily connected, as shown in the above illustration.
Series
Notice the end node devices are connected to the switch by either straightthrough or crossover twisted-pair cables. Either cable type can be used
because of the “HP Auto MDI-X” feature on the 10/100-TX vl ports and the
standard “Auto MDI/MDI-X” feature on the Gig-T vl Module to which the server
is connected.
2-23
Page 44
Series
Installing the Switch 4200vl Series
Example Network Topologies
Legacy Connectivity
switch 2524
hp procurve
25
14 15 16 17 18
1
13
23456
26
switch 2524
j4813a
20 21 22 23
7
89
19
10 11 12
Power
Fault
100-FX for long
distance (up to 2 km)
ActFDx
Max
Fan
Self
Reset
Clear
Console
LED Mode Select
Status
Test
Transceiver Ports
( See manual for supported transceivers)
!
25
Link
Mode
24
Link
Mode
!
23456 131415161718
1
10/100Base-T Ports (1-24)
(all ports are HP Auto-MDIX)
26
78 9 101112 192021222324
switch 4204vl
ProCurve
Self Test
Switch 4204vl
J8770A
ClearReset
Console
Power
Fault
Auxiliary Port
Link|Mode
2 314 5 6 7 8 9 10 11 12
123456789101112
ProCurve
100-FX MTRJ
vl Module
J8763A
100Base-FX MTRJ Ports
1 2 A BCD
Fan
Power
Spd mode: off = 10 Mbps
flash = 100 Mbps
on = 1000 Mbps
Status
SpdFDxAct
!
Modules
LED Mode
Use vl modules only
Link ModeLink Mode
31
A
ProCurve
10/100-TX
vlModule
Link ModeLink Mode
J8765A
Link ModeLink Mode
31
C
ProCurve
10/100-TX
vl
vlModule
Module
Link ModeLink Mode
J8765A
Serial No.
System MAC Address
SG12345678 00-01-e7-12-34-56
00Base-TXP
10/1
orts—all ports are HP A uto MDI-X
5
00Base-TXP
10/1
orts—all ports are HP A uto MDI-X
5
23
171921
13151197
141612108642
13151197
141612108642
18
171921
18
202224
202224
B
vl
Module
23
D
vl
Module
Installing the Switch 4200vl
Transceiver Ports
hp procurve
25
26
switch 2524
j4813a
Power
Reset
Clear
Console
Fault
( See manual for supported transceivers)
!
25
14 15 16 17 18
1
13
23456
Link
Mode
20 21 22 23
7
89
19
10 11 12
24
Link
Mode
ActFDx
Max
!
Fan
Self
LED Mode Select
Status
Test
23456 131415161718
1
10/100Base-T Ports (1-24)
(all ports are HP Auto-MDIX)
26
78 9 101112 192021222324
switch 2524
Figure 2-16. Legacy Topology
For existing networks with 100-FX legacy links, the vl 100-FX module provides
connectivity for a distance of up to 2 km. The 10/100-TX vl modules provide
connectivity for printers, PCs, and legacy servers running at 100 mbps.
2-24
Page 45
Use as an Edge Switch
ProCurve
Routing Switch 9308m
trunked
redundant Gigabit
fiber-optic links
Installing the Switch 4200vl Series
Example Network Topologies
trunked
redundant Gigabit
fiber-optic links
Installing the Switch 4200vl
switch 4200vl
Serial No.
ProCurve
Switch 4202vl
J8772A
Console
Power
Fault
Spd mode: of f = 10 Mbps
Self Test
flash = 100 Mbps
Use
on = 1000 Mbps
Status
Mode
Link
1
3
vl Modules
FDx
Act
Spd
1 2 A B
!
only
ClearReset
LED Mode
Fan
Power
Modules
Auxiliary Port
Mode
Link
2
4
Mode
Link
25
27
Mode
Link
28
26
Mode
Link
51
49
Mode
Link
52
50
System MAC Address
10/100Base-TX Ports (1-72) all ports are HP Auto MDI-X
SG12345678 00-01-e7-12-34-56
Mode
Link
13
9
15
17
11
23
21
7
19
5
Mode
Link
14
108
22
6
20
12
24
16
18
Mode
Link
33
43
41
35
39
29
45
31
37
47
Mode
Link
42
40
38
34
46
44
30
36
48
32
Mode
Link
57
69
55
61
65
59
63
71
53
67
Mode
Link
66
68
54
62
60
72
58
70
56
64
ProCurve
Switch 4208vl
J8773A
Power
Fault
ProCurve
10/100-TX
vlModule
J8765A
ProCurve
10/100-TX
vlModule
J8765A
Console
Link ModeLink Mode
Link ModeLink Mode
Link ModeLink Mode
Link ModeLink Mode
Self Test
Status
1 2 A BCD E F G H
ClearReset
Fan
Power
Modules LED Mode
Auxiliary Port
00Base-TXP
10/1
orts—allports are HP Auto MDI- X
531171921
13151197
141612108642
00Base-TXP
10/1
orts—allports are HP Auto MDI- X
531171921
13151197
141612108642
Spd mode: of f = 10 Mbps
Serial No.
System MAC Address
SG12345678 00-01-e7-12-34-56
flash = 100 Mbps
on = 1000 Mbps
SpdFDxAct
!
Use vl modules only
00Base-TXP
10/1
orts—allports are HP Auto MDI- X
23
Link ModeLink Mode
ProCurve
10/100-TX
vl
vlModule
Module
202224
18
Link ModeLink Mode
J8765A
23
Link ModeLink Mode
ProCurve
10/100-TX
vl
vlModule
Module
202224
18
Link ModeLink Mode
J8765A
531171921
13151197
141612108642
00Base-TXP
10/1
orts—allports are HP Auto MDI- X
531171921
13151197
141612108642
23
vl
Module
202224
18
23
vl
Module
202224
18
switch 4200vl
Figure 2-17. Edge Topology
When your network expands and the users need to access resources beyond
the edge of the local network, the Switch 4200vl Series are excellent platforms
for that expansion. With the flexibility of 2, 4 or 8 slots, the high port count 10/
100-TX vl Module for local connections, and the availability of Gigabit speeds
through the Gig-T vl Module, the Switch 4200vl Series can provide that access
beyond the edge for a high number of network users.
In the above illustration, two Switch 4200vl Series are connected to a ProCurve
Routing Switch 9308m, which can serve as a campus backbone or core switch.
The connections are trunked to provide redundancy and load sharing for
higher bandwidth.
Series
The 1000 Mbps fiber-optic connections between the two Switch 4200vl Series
and the Routing Switch 9308m is by way of Gigabit-LX mini-GBICs installed
in mini-GBIC vl Modules in the two Switch 4200vl Series and Gigabit-LX ports
on the Routing Switch 9308m. With the Gigabit-LX connections, the distance
between the 4200vl switches and the Routing Switch 9308m can be up to ten
kilometers.
2-25
Page 46
Installing the Switch 4200vl Series
Example Network Topologies
Used as an Aggregation Switch
switch 4200vl
Series
Installing the Switch 4200vl
switch 4200vl
switch 8200zl
switch 4200vl
switch 4200vl
switch 4200vl
Figure 2-18. 10-GbE Aggregation Topology
The J8766A module in the Switch 4200vl Series will provide customers with a
10-GbE uplink connection (expected throughput is 2.5 to 7 Gbps, depending
on packet size). Traffic from a single MAC SA to a single MAC DA will be
limited to at most 1 Gbps. Each Switch 4200vl Series can support up to 4
J8766A modules. The 10-GbE module supports trunking – however, it can only
trunk 2, 10 Gigabit ports, and they cannot be mixed with other port speeds in
the trunk.
2-26
Page 47
Getting Started With Switch Configuration
This chapter is a guide for using the console Switch Setup screen to quickly
assign an IP (Internet Protocol) address and subnet mask to the switch, set a
Manager password, and, optionally, configure other basic features.
For more information on using the switch console and the other switch
management interfaces: the web browser interface and the SNMP management tool, ProCurve Manager, please see the Management and Configuration Guide for your switch, available on the ProCurve Web site, www.procurve.com.
Recommended Minimal Configuration
In the factory default configuration, the switch has no IP (Internet Protocol)
address and subnet mask, and no passwords. In this state, it can be managed
only through a direct console connection. To manage the switch through inband (networked) access, you should configure the switch with an IP address
and subnet mask compatible with your network. Also, you should configure
a Manager password to control access privileges from the console and web
browser interface. Other parameters in the Switch Setup screen can be left at
their default settings or you can configure them with values you enter.
3
Getting Started With Switch
Configuration
Many other features can be configured through the switch’s console interface,
to optimize the switch’s performance, to enhance your control of the network
traffic, and to improve network security. Once an IP address has been configured on the switch, these features can be accessed more conveniently through
a remote Telnet session, through the switch’s web browser interface, and from
an SNMP network management station running a network management
program, such as ProCurve Manager. For a listing of switch features available
with and without an IP address, refer to “How IP Addressing Affects Switch
Operation” in the Management and Configuration Guide for your switch,
available on the ProCurve Web site.
For more information on IP addressing, refer to “IP Configuration” in the
Management and Configuration Guide.
3-1
Page 48
Getting Started With Switch Configuration
NoteBy default, the switch is configured to acquire an IP address configuration
from a DHCP or Bootp server. To use DHCP/Bootp instead of the manual
method described in this chapter, see “DHCP/Bootp Operation” in the
Management and Configuration Guide for your switch, available on the
ProCurve Web site.
Using the Switch Setup Screen
The quickest and easiest way to minimally configure the switch for management and password protection in your network is to use a direct console
connection to the switch, start a console session, and access the Switch Setup
screen.
1.Using the method described in the preceding section, connect a terminal
device to the switch and display the switch console command (CLI)
prompt (the default display).
The CLI prompt appears displaying the switch model number:
ProCurve Switch 4208vl#
2.At the prompt, enter the setup command to display the Switch Setup
screen. The following illustration shows the Setup screen with the default
settings.
Configuration
Getting Started With Switch
Figure 3-1. Example of a Switch Setup Screen
3.Use the Tab key to select the Manager Password field and enter a manager
password of up to 16 characters.
4.Tab to the IP Config field and use the Space bar to select the Manual option.
3-2
Page 49
Getting Started With Switch Configuration
5.Tab to the IP Address field and enter the IP address that is compatible with
your network.
6.Tab to the Subnet Mask field and enter the subnet mask used for your
network.
7.Press Enter, then S (for S
ave).
The following is information on the fields in the Setup screen. For more
information on these fields, see the Management and Configuration Guide
for your switch, available on the ProCurve Web site:
ParameterDefaultDescription
System NameblankOptional; up to 25 characters, including spaces
System ContactblankOptional; up to 48 characters, including spaces
Manager PasswordblankRecommended; up to 16 characters (no blank spaces)
Logon DefaultCLIThe default setting selects the command line interface for console access.
The alternative is the Menu interface.
Time Zone0 (none)Optional; 1440 to -1440. The number of minutes your location is to the
West (-) or East (+) of GMT.
Community NamepublicDefault setting recommended.
Spanning Tree EnabledNoDefault setting recommended unless STP is already running on your network
or the switch will be used in complex network topologies.
Default GatewayblankRecommen ded; Enter the IP addre ss of the next-hop gateway node if network
traffic needs to be able to reach off-subnet destinations.
Getting Started With Switch
Configuration
Time Sync MethodNoneOptional; The protocol the switch uses to acquire current date and time
information. The options are SNTP and TimeP.
IP ConfigDHCP/BootpSet to Manual unless a DHCP/Bootp server is used on your network to
configure IP addressing.
IP Addressxxx.xxx.xxx.xxx Recommended; If you set IP Config to Manual, then enter an IP address
compatible with your network.
Note: The IP address and subnet mask assigned for the switch must be compatible with the IP addressing used in
your network. For more information on IP addressing, see the Management and Configuration Guide for your switch,
available on the ProCurve Web site
Subnet Maskxxx.xxx.xxx.xxx Recommended; If you entered an IP address, then enter a subnet mask
Proxy ARPNoDefault setting is recommended until routing is enabled.
.
compatible with your network.
3-3
Page 50
Getting Started With Switch Configuration
Where to Go From Here
The above procedure configures your switch with a Manager password, IP
address, and subnet mask. As a result, with the proper network connections,
you can now manage the switch from a PC equipped with Telnet, a web
browser interface, or from an SNMP-based network management station
using a tool such as ProCurve Manager.
Some basic information on managing your switch is included in the next
section. For more information on the console, web browser, and SNMP
management interfaces and all the features that can be configured on the
Switch 4200vl Series, see the Management and Configuration Guide for your
switch, available on the ProCurve Web site.
To Recover from a Lost Manager Password: If you cannot start a console session at the manager level because of a lost Manager password, you
can clear all passwords and user names by getting physical access to the
switch and pressing and holding the Clear button for a full second.
Configuration
Getting Started With Switch
3-4
Page 51
Getting Started With Switch Configuration
Using the IP Address for Remote Switch Management
Using the IP Address for Remote Switch
Management
With the minimal configuration described in the last section for your Switch
4200vl Series, you can use the switch’s IP address to manage the switch from
any PC that is on the same subnet as the switch. You can use either a Telnet
session or a standard web browser to manage the switch.
Starting a Telnet Session
To access the switch through a Telnet session, follow these steps:
1.Ensure the switch is configured with an IP address and that the switch is
reachable from the PC that is running the Telnet session (for example, by
using a ping command to the switch’s IP address).
2.Start the Telnet program on a PC that is on the same subnet as the switch
and connect to the switch’s IP address.
3.You will see the copyright page and the message “Press any key to
continue”. Press a key, and you will then see the switch console command
(CLI) prompt, for example:
ProCurve Switch 4208vl#
Enter help or ? to see a list of commands that can be executed at the
prompt. Entering any command followed by help provides more detailed
context help information about the command. Entering any command
followed by ? displays a list of options that are available at that point in
the command entry.
Starting a Web Browser Session
Your Series 4200vl Switch can be managed through a graphical interface that
you can access from any PC or workstation on the network by running your
web browser and typing in the switch’s IP address as the URL. No additional
software installation is required to make this interface available; it is included
in the switch’s onboard software.
A typical web browser interface screen is shown in the next illustration.
Getting Started With Switch
Configuration
3-5
Page 52
Getting Started With Switch Configuration
Using the IP Address for Remote Switch Management
ProCurve Switch 4204vl - Status: Information
J8770A ProCurve Switch 4204vl
xl
xl
Figure 3-2. Example of a Web Browser session
PoEStatus
05
For more information on using the web browser interface, please see the
Management and Configuration Guide for your switch, available on the
ProCurve Web site.
An extensive help system is also available for the web browser interface. To
access the help system though, the subnet on which the switch is installed
Configuration
must have access to the internet, or ProCurve Manager needs to be installed
on a network management station that is on the subnet.
Getting Started With Switch
3-6
Page 53
Troubleshooting
This chapter describes how to troubleshoot your Switch 4200vl Series. Note
that this document describes troubleshooting mostly from a hardware
perspective. You can perform more in-depth troubleshooting using the software tools available with the switch, including the full-featured console
interface, the built-in web browser interface, and ProCurve Manager, the
SNMP-based network management tool. For more information, see the
chapter on “Troubleshooting” in the Management and Configuration Guide,
for your switch, available on the ProCurve Web site www.procurve.com.
This chapter describes the following:
■basic troubleshooting tips (page 4-2)
■diagnosing with the LEDs (page 4-4)
■Proactive Networking tools (page 4-10)
■hardware diagnostic tests (page 4-11)
■restoring the factory default configuration (page 4-13)
■downloading new code (page 4-14)
■HP Customer Support Services (page 4-14)
4
Troubleshooting
4-1
Page 54
Troubleshooting
Basic Troubleshooting Tips
Basic Troubleshooting Tips
Most problems are caused by the following situations. Check for these items
first when starting your troubleshooting:
■Faulty or loose cables. Look for loose or obviously faulty connections.
If they appear to be OK, make sure the connections are snug. If that does
not correct the problem, try a different cable.
■Non-standard cables. Non-standard and miswired cables may cause
network collisions and other network problems, and can seriously impair
network performance. Use a new correctly-wired cable or compare your
cable to the cable in appendix B, “Switch Ports and Network Cables” for
pinouts and correct cable wiring. A category 5 cable tester is a recommended tool for every 100Base-TX and 1000Base-T network installation.
■Improper Network Topologies. It is important to make sure you have
a valid network topology. Common topology faults include excessive
cable length and excessive repeater delays between end nodes. If you have
network problems after recent changes to the network, change back to
the previous topology. If you no longer experience the problems, the new
topology is probably at fault.
In addition, you should make sure that your network topology contains
no data path loops. Between any two end nodes, there should be only
one active cabling path at any time. Data path loops will cause broadcast
storms that will severely impact your network performance.
With your Switch 4200vl Series, if you wish to build redundant paths
between important nodes in your network to provide some fault tolerance, you should enable Spanning Tree Protocol support on the switch.
This ensures that only one of the redundant paths is active at any time,
thus avoiding data path loops. Spanning Tree can be enabled through the
switch console, the web browser interface, or ProCurve Manager.
The Switch 4200vl Series also support Trunking, which allows multiple
network cables to be used for a single network connection without
causing a data path loop. See the Management and Configuration Guide
for your switch, available on the ProCurve Web site, for more information
on Spanning Tree and on Trunking.
Troubleshooting
4-2
Page 55
Troubleshooting
Basic Troubleshooting Tips
■Connecting to devices that have a fixed full-duplex configuration.
The RJ-45 ports on the Switch 4200vl Series are all configured as “Auto”.
That is, when connecting to attached devices, the switch will operate in
one of two ways to determine the link speed and the communication mode
(half duplex or full duplex):
•if the connected device is also configured to Auto, the switch will
automatically negotiate both link speed and communication mode
•if the connected device has a fixed configuration, for example 100
Mbps, at half or full duplex, the switch will automatically sense the
link speed, but will default to a communication of half duplex
Because the Switch 4200vl Series behave in this way (in compliance with the IEEE 802.3 standard), if a device connected to the switch has a fixed
configuration at full duplex, the device will not connect correctly to the
switch. The result will be high error rates and very inefficient communications between the switch and the device.
Ensure that all devices connected to the Switch 4200vl Series are configured to auto negotiate, or are configured to connect at half duplex (all
hubs are configured this way, for example).
If necessary though, you can modify the configuration of the ports on the
Switch 4200vl Series to match the configuration of the connected device.
Use the switch console, the web browser interface, or ProCurve Manager
to modify the port configuration.
■Check the port configuration. A port on your Series 4200vl Switch may
not be operating as you expect because it has been put into a “blocking”
state by Spanning Tree, GVRP (automatic VLANs), or LACP (automatic
trunking). (Note that the normal operation of the Spanning Tree, GVRP,
and LACP features may put the port in a blocking state.) Or, the port just
may have been configured as disabled through software.
Use the switch console to determine the port’s configuration and verify
that there is not an improper or undesired configuration of any of the
switch features that may be affecting the port. See the Management and Configuration Guide for your switch, available on the ProCurve Web site,
for more information.
For more information on possible network problems and their solutions, refer
to the technical note “Troubleshooting LAN Performance and Intermittent
Connectivity Problems”, which can be found on the ProCurve Web site,
www.procurve.com, in the Information Library section.
Troubleshooting
4-3
Page 56
Troubleshooting
Diagnosing with the LEDs
Diagnosing with the LEDs
Tables 4-1 shows LED patterns on the switch and the switch modules that
indicate problem conditions.
1.Check in the table for the LED pattern you see on your switch
2.Refer to the corresponding diagnostic tip on the next few pages.
Table 4-1.LED Error Indicators
LED Pattern Indicating Problems
Power
Off with
Diag
Tip s
Fault
111111
Self Test
Fan Status
Power Status
(one LED per
power supply)
Module Status
module)
(one LED per
Port Link
A
Brief Problem
Description
No power
power cord
plugged in
OnProlonged OnProlonged
On
OnFlashing
OnFlashing
OnFlashing
2
OffFlashing
2
Off
2
Flashing
2
11 1 1
2
1
1
11 1
Flashing
1
2
11
Off
1
C
D
B
Self test fail entire switch
Fan fail
Power supply fail
E
Self test fail -
backplane
OnFlashing2Flashing
2
2
Flashing
Flashing
OnFlashing
OnFlashing
2
2
2
11 1
11
11
Flashing
Flashing2Flashing
Flashing
2
2
1
2
Fixed port self test fail
F
G
H
Module self test fail
Module-based port
self test fail
OnOffFlashing
2
11
Flashing
2
1
I
Module invalid
(wrong chassis) or
unsupported (needs
newer software)
OnOffFlashing
2
11
Flashing2Flashing
2
J
SFP invalid (not
ProCurve/no t model B),
or unsupported (needs
newer software)
Troubleshooting
OnOffOff
11
Flashing2On briefly
then off
K
Different module
hot swap
4-4
Page 57
LED Pattern Indicating Problems
Troubleshooting
Diagnosing with the LEDs
Power
OnOffOff
OnOffOff
1
This LED is not important for the diagnosis.
2
The flashing behavior is an on/off cycle once every 1.6 seconds, approximately.
3
The fast flashing behavior is an on/off cycle once every 0.8 seconds, approximately.
Fault
Self Test
Fan Status
11 1
11 1
Power Status
(one LED per
power supply)
module)
(one LED per
Module Status
Port Link
Fast
Flashing
Off with
cable
connected
Diagnostic Tips:
Tip
Letter
A
ProblemSolution
The power supp lies
installed in the
switch are not
plugged into active
AC power sources,
or the power sup ply
may have failed.
1. Verify the power cord is plugged into an active power source and to the switch.
Ensure these connections are snug.
2. Try power cycling the switch by unplugging and plugging the power cord back in.
3. If the Power LED is still not on, verify the AC power source works by plugging
another device into the outlet. Or try plugging the switch into a different outlet or
try a different power cord.
If the power source and power cord are OK and this condition persists, the switch
power supply may have failed. Call your HP-authorized LAN dealer, or use the
electronic support services from HP to get assistance. See the Customer Support/
Warranty card for more information.
Diag
Tip s
L
3
M
Brief Problem
Description
Port security
disabled the port
No link on port
B
C
A switch hardware
failure has
occurred. All the
LEDs will stay on
indefinitely.
One or more of the
switch cooling fans
may have failed.
Try power cycling the switch. If the fault indication reoccurs, the switch may have
failed. Call your HP-authorized LAN dealer, or use the electronic support services
from HP to get assistance. See the Customer Support/Warranty card for more
information.
Troubleshooting
Try disconnecting power from the switch and wait a few moments. Then reconnect
the power to the switch and check the LEDs again. If the error indication reoccurs,
one or more of the fans have failed. The switch has multiple fans and may continue
to operate OK under this condition if the ambient temperature does not exceed
normal room temperature, but for best operation, the switch should be replaced.
Contact your HP-authorized LAN dealer, or use the electronic support services from
HP to get assistance. See the Customer Support/Warranty card for more
information.
4-5
Page 58
Troubleshooting
Diagnosing with the LEDs
Tip
Letter
ProblemSolution
D
A fault condition
has been detected
on the power
supply installed in
the slot
corresponding to
the flashing
number.
E
The switch has
experienced a
backplane failure
during self test.
Because the Power LED is on, the switch is receiving power from one power supply,
but the power supply in the slot corresponding to the flashing number may be
unplugged from an active AC power source, or may be faulty.
• Verify the power cord for the power supply whose number is flashing is plugged
into an active power source and to the switch. Ensure these connections are
snug.
• Disconnect the AC power cord from the power supply in the slot corresponding
to the flashing number, then try removing and reinstalling the power supply.
Caution: Ensure the AC power cord is disconnected from the supply before re moving
and reinstalling the supply.
Reconnect t he power supply to the AC p ower source. If the error indication r eoccurs
after the supply is reinstalled, the power supply may be faulty. Call your HPauthorized LAN dealer, or use the electronic support services from HP to get
assistance. See the Customer Support/Warranty card for more information.
The failure may be just in the communications with a single module slot, or it might
be more significant. Start a console session with the switch, and at the CLI prompt
issue the command show logging. In the event log that is displayed, there will be
messages that describe the extent of the problem. If the problem is with individual
slots, the remainder of the switch slots will be fully operational and can be used until
you get a chance to replace the switch.
If necessary to resolve the problem, contact your HP-authorized LAN dealer, or use
the electronic support services from HP to get assistance. See the Customer
Support/Warranty card for more information.
F
G
The network port
for which the Link
LED is flashing has
experienced a self
test or initialization
failure.
The module
installed in the slot
that corresponds to
the letter that is
flashing has
experienced a self
test or initialization
fault.
When the switch is powered on, each network port is tested. If the port self test fails,
the individual port is not usable, but the rest of the ports on the chassis, which have
passed their self test, will continue to operate normally.
To verify the port has failed, try power-cycling the switch. If the port fault indication
reoccurs, and the port is one of the fixed ports on the chassis, you will have to
replace the switch. In the meantime, all the other fixed ports on the chassis will
operate normally.
The modules are all tested whenever the switch is powered on, or reset (through
the Reset button on the switch, or the Reboot or Reset options in the console or web
browser interface), and when they are hot swapped (installed when the switch is
powered on).
Try removing and reinstalling the module. You can do this without having to power
down the switch. When the module is reinstalled, it will be retested automatically.
If the faul t indication reoccurs, the module may have fail ed. Remove the module from
the switch and replace it with another module, or install a slot cover plate. Call your
ProCurve authorized LAN dealer, or use the electronic support services from
ProCurve to get assistance. See the Customer Support/Warranty card for more
information.
Troubleshooting
4-6
Page 59
Tip
Letter
Troubleshooting
Diagnosing with the LEDs
ProblemSolution
H
The module-based
network port for
which the Link LED
is flashing has
experienced a self
test or initialization
failure.
I
The module
installed in the slot
that corresponds to
the letter that is
flashing is an
invalid or
unsupported
module.
During the modul e self test, described in tip letter G earlier in this table, each network
port is also tested. If the port self test fails, the individual port is not usable, but the
rest of the ports on the module, which have passed their self test, will continue to
operate normally.
To verify the port has failed, try removing and reinstalling the module. If the port is
a mini-GBIC, you can remove and reinstall the mini-GBIC without having to remove
the module. The mini-GBICs are tested when they are hot swapped. If the port fault
indication reoccurs, and you need to be able to use the port, you will have to replace
the mini-GBIC or the module. In the meantime, all the other module ports will operate
normally.
Ensure you have installed a vl module in the slot. ProCurve gl and xl modules will fit
in the slot, but they are not compatible with your ProCurve vl switch. Check to ensure
the module has a “vl module” label on it.
If the module does not have a “vl module” label, remove the module from the switch
and replace it with a vl module, or re-cover the slot with the cover plate. You can
remove and replace the module without having to power down the switch. Call your
ProCurve authorized LAN dealer, or use the electronic support services from
ProCurve to get information on supported Switch vl modules. The vl modules that
are available as of the printing of this manual are listed on page 1-4.
If the module has a “vl module” label, then the LED pattern indicates that the module
is unsupported in the version of software currently running on the switch. As
ProCurve introduces new modules for the vl switches you may have to update the
switch with new operating code that supports the new module. The documentation
that came with the module will indicate which version of the operating code is
needed to support the module. The latest code can be downloaded from the
ProCurve Web site at www.procurve.com. Download the new code and retest the
module by booting the switch with the new software.
K
J
The mini-GBIC or
SFP installed in the
mini-GBIC slot for
which the Link LED
is flashing is an
invalid or
unsupported
transceiver.
Ensure you have installed a model B or greater ProCurve mini-GBIC or SFP in the
slot. Model A mini-GBICs are not supported in the Switch 4200vl Series.
If the mini-GBIC or SFP is a model B or greater, then the LED pattern indicates the
transceiver is unsupported in the version of software currently running on the
switch. As ProCurve introduces new transceivers for the vl switches you may have
to update the switch with new operating code that supports the new transceiver.
The documentation that came with the transceiver will indicate which version of the
operating code is needed to support the transceiver. The latest code can be
downloaded from the ProCurve Web site at www.procurve.com. Download the new
code and retest the transceiver by rebooting the switch with the new software.
Troubleshooting
In the slot
corresponding to
the letter that is
flashing, a module
was installed t hat is
a different type
than the previously
installed module,
and the switch has
not yet been reset.
When you “hot swap” modules in the switch slots, if you install a different module
type than the one that was previously installed in the slot, you must reset the switch
so the switch processor can properly initialize and configure the new module type.
The flashing LED informs you that this change of module types has occurred. The
module will not work properly until the switch is reset.
You can reset the switch by any of these methods:
• pressing the Reset button.
• power cycling the switch.
• selecting the reset or reboot option from the console, web browser interface, or
ProCurve Manager.
4-7
Page 60
Troubleshooting
Diagnosing with the LEDs
Tip
Letter
ProblemSolution
L
The network port
for which the Link
LED is flashing has
been disabled
because port
security has been
configured on the
switch and a
security violation
has been detected
on the port.
For the Port Security feature, you can configure the switch so that whenever a
security violation is detected on a port, the switch will disable the port. When a port
is disabled by this feature, the port Link LED will be continuously flashed at the fast
rate of 0.8 seconds per cycle. The flashing continues until you clear the security
violation through the switch console. In the console, you can view the identity of the
connected device that committed the security violation.
Once the security violation is cleared, you must re-enable the port through the
console.
For more information on the Port Security feature, see the Management and Configuration Guide, for your switch, available on the ProCurve Web site.
Troubleshooting
4-8
Page 61
Tip
Letter
Troubleshooting
Diagnosing with the LEDs
ProblemSolution
M
The network
connection is not
working properly.
Try the following procedures:
• For the indicated port, verify both ends of the cabling, at the switch and the
connected device, are securely connected.
• Verify the connected device and switch are both powered on and operating
correctly.
• Verify you have used the correct cable type for the connection.
– for any of the twisted-pair connections, in the default configuration (Auto),
either a straight-through or a crossover cable can be used and the switch will
automatically adjust its operation. See the “HP Auto MDI-X Feature”
description on page B-5 for more information.
Note: If the module configuration is changed to one of the fixed
configuration options though (for example, 100-Full Duplex), then the port
operates as MDI-X only and the correct type of cable must be used. in
general, for connecting to an end node (MDI port), use straight-through
cable; for connecting to MDI-X ports on hubs, other switches, and routers,
use crossover cable.
– for fiber-optic connections, verify that the transmit port on the switch is
connected to the receive port on the connected device, and the switch
receive port is connected to the transmit port on the connected device, and
that both devices are transmitting correctly.
• For a 1000 Mbps connection, verify the network cabling complies with the IEEE
802.3ab standard. The cable should be installed according to the ANSI/TIA/EIA568-A-5 specifications. Cable testing should comply with the stated limitations
for Attenuation, Near-End Crosstalk, Far-End Crosstalk, Equal-Level Far-End
Crosstalk (ELFEXT), Multiple Disturber ELFEXT, and Return Loss.
The cable verification must include the patch cables that connect the switch and
other end devices to the patch panels in the cabling path.
• Verify the port has not been disabled through a switch configuration change.
You can use the console interface, or, if you have configured an IP address on
the switch, use telnet, the web browser interface, or ProCurve Manager network
management software to determine the state of the port and re-enable the port
if necessary.
• Verify the switch port configuration matches the configuration of the attached
device. For example, if the switch port is configured as “Auto”, the port on the
attached devi ce also MUST be conf igured as “Auto” or ”half-dupl ex”. Depending
on the port type, twisted-pair or fiber-optic, if the configurations don’t match, the
results could be a very unreliable connection, or no link at all.
If the other procedures don’t resolve the problem, try using a different port or a
different cable.
Troubleshooting
4-9
Page 62
Troubleshooting
Proactive Networking
Proactive Networking
The Switch 4200vl Series have built-in management capabilities that
proactively help you manage your network including:
■finding and helping you fix the most common network error conditions
(for example, faulty network cabling, and non-standard network
topologies)
■informing you of the problem with clear, easy-to-understand messages
■recommending network configuration changes to enhance the
performance of your network
The following interfaces provide tests, indicators, and an event log that can
be used to monitor the switch and its network connections, and to help you
take advantage of these proactive networking features:
■ProCurve Manager - an SNMP-based network management tool included
with your switch
■A graphical web browser interface you can use to manage your switch
from a PC that is running a supported web browser, for example Microsoft
Internet Explorer or Netscape Communicator.
■A full-featured easy-to-use console interface you can access by merely
connecting a standard terminal or PC running a terminal emulator to the
switch’s console port. The cable to make that connection is provided with
your switch. The console interface is also accessible through a telnet
connection.
See the “Troubleshooting” chapter in the Management and Configuration Guide for your switch, available on the ProCurve Web site, for more information on using these software tools to diagnose and manage your switch.
Troubleshooting
4-10
Page 63
Troubleshooting
Hardware Diagnostic Tests
Hardware Diagnostic Tests
Testing the Switch by Resetting It
If you believe that the switch is not operating correctly, you can reset the
switch to test its circuitry and operating code. To reset a switch, either:
■Unplug and plug in the power cord (power cycling).
■Press the Reset button on the front of the switch.
■Select the reset or reboot option from the console, web browser interface,
or ProCurve Manager.
Power cycling the switch, pressing the Reset button, and the software reset
or reboot options all cause the switch to perform its power-on self-test, which
almost always will resolve any temporary operational problems. These reset
processes also cause any network traffic counters to be reset to zero and cause
the System Up Time timer to reset to zero. Neither of these reset procedures
causes any changes to the switch configuration. Be sure the latest configuration changes have been saved (with the “write memory” command) before
resetting the switch.
Checking the Switch LEDs
The self-test passes if the Fault and Self Test LEDs on the front of the switch
go off after approximately 90 to 150 seconds depending on the number and
type of modules installed in the switch. If these LEDs stay on longer than 180
seconds or begin flashing, the switch, or a module, or an individual mini-GBIC
may have to be replaced as indicated by the LEDs.
See “Diagnosing With the LEDs” on page 4-4 for information on interpreting
the LED patterns.
Checking Console Messages
Useful diagnostic messages may be displayed on the console screen when the
switch is reset. As described in chapter 2 under step 8, “Connect a Console to
the Switch”, connect a PC running a VT-100 terminal emulator program or a
standard VT-100 terminal to the switch’s Console Port and configure it to run
at 9600 baud and with the other terminal communication settings shown on
page 2-20. Then, when you reset the switch, note the messages that are
displayed.
Troubleshooting
4-11
Page 64
Troubleshooting
Hardware Diagnostic Tests
Testing Twisted-Pair Cabling
If you think the cable should work but still isn’t working, it may not be
compatible with the IEEE 802.3 Type 10Base-T, 100Base-TX, or 1000Base-T
standards, as appropriate for the switch port type that the cable is connected
to. The twisted-pair cables attached to the Switch 4200vl Series must be
compatible with these standards.To verify your cable is compatible with these
standards, use a qualified cable test device.
HP also offers a wire testing service. Contact your HP-authorized LAN dealer
or your local HP sales office for more information.
Testing Switch-to-Device Network Communications
You can perform the following communication tests to verify the network is
operating correctly between the switch and any connected device that can
respond correctly to the communication test.
■Link Test -- a physical layer test that sends IEEE 802.2 test packets to any
device identified by its MAC address
■Ping Test -- a network layer test used on IP networks that sends test
packets to any device identified by its IP address
These tests can be performed through the switch console interface from a
terminal connected to the switch or through a telnet connection, or from the
switch’s web browser interface. See the Management and Configuration Guide for your switch, available on the ProCurve Web site, for more information.
These tests can also be performed from an SNMP network management
station running a program that can manage the switch, for example, ProCurve
Manager.
Testing End-to-End Network Communications
Both the switch and the cabling can be tested by running an end-to-end
communications test -- a test that sends known data from one network device
to another through the switch. For example, if you have two PCs on the
network that have LAN adapters between which you can run a link-level test
or Ping test through the switch, you can use this test to verify the entire
communication path between the two PCs is functioning correctly. See your
LAN adapter documentation for more information on running the link test or
Troubleshooting
Ping test.
4-12
Page 65
Troubleshooting
Restoring the Factory Default Configuration
Restoring the Factory Default
Configuration
As part of your troubleshooting process, it may become necessary to return
the switch configuration to the factory default settings. This process momentarily interrupts the switch operation, clears any passwords, clears the console
event log, resets the network counters to zero, performs a complete self test,
and reboots the switch into its factory default configuration including deleting
an IP address, if one is configured.
NoteThis process removes all switch configuration changes that you have made
from the factory default settings. This includes, for example, configuration of
VLANs, spanning tree, trunks, stacking, routing, and security. Returning the
configuration of these features to their factory default settings (usually
disabling them) may result in network connectivity issues.
If the switch has a valid configuration, and you are restoring the factory default
settings for a reason other than configuration problems, you should save the
switch configuration prior to performing the factory default reset. Then, after
the reset and resolution of the original problem, you can restore the saved
configuration to the switch. For both the save and restore processes, you can
use the console copy command. See the Management and Configuration Guide for your switch, available on the ProCurve Web site, for more information on this command.
You can restore the factory default configuration either on the switch itself or
through the switch console.
To execute the factory default reset on the switch, perform these steps:
1.Using pointed objects, simultaneously press both the Reset and Clear
buttons on the front of the switch.
2.Continue to press the Clear button while releasing the Reset button.
3.As soon as the Self Test LED begins to blink, release the Clear button.
The switch will then complete its self test and begin operating with its
configuration restored to the factory default settings.
Troubleshooting
To restore the factory default configuration using the console, execute the
erase startup-config command from the console command prompt. Then
reboot so that the factory default startup configuration takes effect.
4-13
Page 66
Troubleshooting
Downloading New Code
Downloading New Code
When product enhancements occur for the Switch 4200vl Series, new code
can be downloaded to the switch through several methods, for product
enhancements and new features. Please see the Management and Configu-ration Guide for your switch, available on the ProCurve Web site, for more
information.
The new code would be available on the ProCurve Web site,
www.procurve.com.
HP Customer Support Services
If you are still having trouble with your switch, Hewlett-Packard offers support
24 hours a day, seven days a week through the use of a number of automated
electronic services. See the Customer Support/Warranty booklet that came
with your switch for information on how to use these services to get technical
support. The ProCurve Web site, www.procurve.com also provides up-to-date
support information.
Additionally, your HP-authorized network reseller can provide you with assistance, both with services that they offer and with services offered by HP.
Before Calling Support
Before calling your networking dealer or HP Support, to make the support
process most efficient, you first should have retrieved the following information:
Information ItemInformation Location
• product identification, including the chassis,
modules, and mini-GBICs
• details about the switch’s status including the OS
(software) version, a copy of the switch configuration, a copy of the switch Event Log, and a
copy of the switch status and counters information
Troubleshooting
• copy of your network topology map, including
network addresses assigned to the relevant devices
the front of the switch, and on the
modules and mini-GBICs
switch console: show tech
command
your network records
4-14
Page 67
A
Specifications
Physical
Width:44.2 cm (17.4 in)
Depth:38.86 cm (15.3 in)
Height:
• All 4208vl Switches
• All 4204vl and 4202vl Switches
Weight:
• Switch 4208vl
• Switch 4208vl-64G
• Switch 4208vl-72GS
• Switch 4208vl-96
• Switch 4204vl
• Switch 4202vl-48G
• Switch 4204vl-48GS
• Switch 4202vl-72
Specifications
• 22.23 cm (8.75 in)
• 13.34 cm (5.25 in)
• 12.18 kg (26.85 lbs)
• 14.65 kg (32.30 lbs) – includes 4 Gig-T vl Modules
• 13.32 kg (29.37 lbs) includes 3 Modules:
– two 24-port Gig-T vl Modules (J8768A)
– one 20-port Gig-T plus 4-port mini-GBIC or SFP
vl Module (J9033A)
• 14.65 kg (32.30 lbs) – includes 4 10/100-TX vl
Modules
• 9.41 kg (20.75 lbs)
• 10.80 kg (23.81 lbs)
• 10.83 kg (23.88 lbs) includes 2 modules:
– one 24-port Gig-T vl Module (J8768A)
– one 20-port Gig-T plus 4-port mini-GBIC or SFP
vl Module (J9033A)
• 10.80 kg (23.81 lbs)
Electrical
The Switch 4200vl Series automatically adjust to any voltage between
100-127 and 200-240 volts and either 50 or 60 Hz.
AC voltage:100–127 volts200–240 volts
Maximum current:8.2 A3.8 A
Frequency range:50/60 Hz50/60 Hz
A-1
Page 68
Specifications
Environmental
OperatingNon-Operating
Temperature:0°C to 40°C (32°F to 104°F)-40°C to 70°C (-40°F to 158°F)
Relative humidity:
(non-condensing)
Specifications
Maximum altitude:4.6 Km (15,000 ft) 4.6 Km (15,000 ft)
15% to 95% at 40°C (104°F)15% to 95% at 65°C (149°F)
Acoustic
Switch 4208vl, and its bundles:
Geräuschemission LwA=63.1 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LwA=63.1 dB in a virtual workspace according to
DIN 45635 T.19
Switch 4204vl, 4202vl-48G, and 4202vl-72 and its bundles:
Geräuschemission LwA=64.2 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LwA=64.2 dB in a virtual workspace according to
DIN 45635 T.19
A-2
Network Connectors
■The 10/100 Mbps RJ-45 twisted-pair ports on the 10/100-TX vl Module are
compatible with the IEEE 802.3 10Base-T and IEEE 802.3u 100Base-TX
standards.
■The 10/100/1000 Mbps RJ-45 twisted-pair ports on the Gig-T vl Module are
compatible with the IEEE 802.3u 100Base-TX and IEEE 802.3ab 1000BaseT standards.
Safety
■EN60950 / IEC 950
■CSA 22.2 No. 950 (cUL1950)
■UL 1950 3
rd
Edition
Page 69
Switch Ports and Network Cables
This appendix includes switch connector information and network cable
information for cables that should be used with the Switch 4200vl Series,
including minimum pin-out information and specifications for twisted-pair
cables.
B
NoteIncorrectly wired cabling is the most common cause of problems for LAN
communications. ProCurve Networking recommends that you work with a
qualified LAN cable installer for assistance with your cabling requirements.
Switch Ports
Twisted Pair
■The RJ-45 ports on the 10/100-TX vl Module and the Gig-T vl Module
accept 100-ohm differential unshielded and shielded twisted-pair cable
with RJ-45 connectors as described on the next page.
Fiber-Optic
■The LC-type connector port on the Gigabit-SX mini-GBIC transmits at
850 nm wavelength, and accepts the low metal content, multimode fiberoptic cables for Gigabit-SX described on page B-3.
■The LC-type connector port on the Gigabit-LX mini-GBIC transmits at
1310 nm wavelength, and accepts the low metal content, single-mode or
multimode fiber-optic cables for Gigabit-LX described on page B-3.
■The LC-type connector port on the Gigabit-LH mini-GBIC transmits at
1550 nm wavelength over single-mode fiber-optic cables as described on
page B-3.
■The MT-RJ connector ports on the 100-FX vl module and the LC-type
connector port on the 100-FX SFP-LC transceiver transmit at 1310 nm
wavelength, and accept the low metal content, multimode fiber-optic
cables for 100Base-FX described on page B-3.
complying with IEEE 802.3ab 1000Base-T specifications,
fitted with RJ-45 connectors—Category 5E or better is
recommended.
(See “Note on 1000Base-T Cable Requirements”, below)
Switch Ports and Network
Note on 1000Base-T Cable Requirements. The Category 5 networking
cables that work for 100Base-TX connections should also work for
1000Base-T, as long as all four-pairs are connected. But, for the most reliable
connections you should use cabling that complies with the Category 5e
specifications, as described in Addendum 5 to the TIA-568-A standard (ANSI/
TIA/EIA-568-A-5).
Because of the increased speed provided by 1000Base-T (Gigabit-T), network
cable quality is more important than for either 10Base-T or 100Base-TX. Site
cabling that is being used to carry 1000Base-T networking must comply with
the IEEE 802.3ab standards. In particular, the cabling must pass tests for
Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT).
Additionally, unlike the cables for 100Base-TX, the 1000Base-T cables must
pass tests for Equal-Level Far-End Crosstalk (ELFEXT), Multiple Disturber
ELFEXT, and Return Loss.
When testing your cabling, be sure to include the patch cables that connect
the switch and other end devices to the patch panels on your site. The patch
cables are frequently overlooked when testing cable and they must also
comply with the cabling standards.
B-2
Page 71
Switch Ports and Network Cables
Fiber-Optic Cables
Port TypeCable SpecificationsConnector TypeMaximum Length
Gigabit-SX 62.5/125 mm or 50/125 μm (core/cladding)
diameter, graded-index, low metal content,
multimode fiber-optic cables, complying
with the ITU-T G.651 and ISO/IEC 793-2 Type
A1b or A1a respectively.
index, low metal content, single mode fiberoptic cables, complying with the ITU-T G.652
and ISO/IEC 793-2 Type B1 standards.
OR
the multimode fiber-optic cables listed for
Gigabit-SX.
Note: To use multimode cables for Gigabit-LX, a mode conditioning patch cord may be needed - See the
Installation Guide that came with your module for more information.
Gigabit-LH 9/125 mm (core/cladding) diameter, graded-
index, low metal content, single mode fiberoptic cables, complying with the ITU-T G.652
and ISO/IEC 793-2 Type B1 standards.
Note: The transmission distances are dependent on the particular fiber loss and coupling loss involved,
among other factors, and can be estimated from the optical loss budget. For distances less than 20km,
a 10dB attenuator must be used. For distances between 20km and 40km, a 5dB attenuator must be used.
Attenuators can be purchased from most cable vendors.
62.5/125 μm or 50/125 μm (core/cladding)
diameter, graded-index, low metal content,
multimode fiber-optic cables, complying
with the ITU-T G.651 and ISO/IEC 793-2 Type
A1b or A1a respectively.
Note: MT-RJ connector is on the module or an LC connector on the SFP transceiver.
10-GbE SRMultimode fiber-optic cable designed for
Gigabit Ethernet: 62.5/125 μm (core/
cladding) diameter or 50/125 μm, low metal
content,
complying with the ITU-T G.652 and ISO/IEC
793-2 Type B1 standards.
MT-RJ or LC• full-duplex connections:
2 kilometers
• half-duplex connections:
412 meters
SC
■62.5 μm cable:
•160 Mhz*km = 2-26 meters
•200 Mhz*km = 2-33 meters
■50 μm cable:
•400 Mhz*km = 2-66 meters
•500 Mhz*km = 2-82 meters
•2000 Mhz*km = 2-300
meters
B-3
Page 72
Switch Ports and Network Cables
Port TypeCable SpecificationsConnector TypeMaximum Length
Switch Ports and Network
Cables
10-GbE LR9/125 μm (core/cladding) diameter, low
metal content, single mode fiber-optic
cables, complying with the ITU-T G.652 and
ISO/IEC 793-2 Type B1 standards.
10-GbE ER9/125 μm (core/cladding) diameter, low
metal content, single mode fiber-optic
cables, complying with the ITU-T G.652 and
ISO/IEC 793-2 Type B1 standards.
Note: Conditioning patch cord cables are not supported for 10-GbE.
(40 kilometers, on an engineered
fiber optic link that meets standards
in the specification).
Supported Length
B-4
Page 73
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Twisted-Pair Cable/Connector Pin-Outs
The HP Auto MDI-X Feature. In the default configuration, “Auto”, the
10/100Base-TX ports on the 10/100-TX vl Modules used in the Switch 4200vl
Series automatically detect the type of port on the connected device and
operate as either an MDI or MDI-X port, whichever is appropriate. So for any
connection, a straight-through twisted-pair cable can be used -- you no longer have to use crossover cables, although crossover cables can also be used for
any of the connections. The Gig-T vl Module supports the IEEE 802.3ab
standard, which includes the “Auto MDI/MDI-X” feature, which operates the
same way.
Switch Ports and Network
NoteHP Auto MDI-X was developed by Hewlett-Packard and shared with the IEEE
for the development of the IEEE 802.3ab standard. HP Auto MDI-X and the
IEEE 802.3ab Auto MDI/MDI-X feature are completely compatible.
If you connect a Series 4200vl Switch twisted-pair port to another switch or
hub, which typically have MDI-X ports, the Series 4200vl Switch port automatically operates as an MDI port. If you connect it to an end node, such as a
server or PC, which typically have MDI ports, the Series 4200vl Switch port
operates as an MDI-X port. In all cases, you can use standard straight through
cables.
If you happen to use a correctly wired crossover cable, though, the switch will
still be able to automatically detect the MDI/MDI-X operation and link
correctly to the connected device.
If the port configuration is changed to any of the fixed configurations
though, for example 100 Mbps/full duplex, the port operates as MDI-X only
and the correct cable type must be used. In general, for connections to MDI
ports, such as end nodes, use a straight-through cable; for connections to MDIX ports, such as on hubs and other switches, use a crossover cable.
Other Wiring Rules:
■All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-A or 568-B (not USOC). See the Pin Assignment
tables below the cable illustrations later in this appendix for a listing of
the signals used on each pin.
Cables
B-5
Page 74
Cables
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
■For 1000Base-T connections, all four pairs of wires in the cable must be
available for data transmission. See “Note on 1000Base-T Cable Requirements” on page B-2 for more information on 1000Base-T cabling.
■For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
100-ohm differential unshielded twisted-pair (UTP) or shielded twistedpair (STP) cable, as supported by the IEEE 802.3 10Base-T standard.
■For 100 Mbps connections to the ports, use Category 5 100-ohm differen-
tial UTP or STP cable only, as supported by the IEEE 802.3u 100Base-TX
standard.
or STP cable only, as supported by the IEEE 802.3ab 1000Base-T standard;
Category 5e or better is recommended.
Switch Ports and Network
B-6
Page 75
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Straight-Through Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connections
Because of the HP Auto MDI-X operation of the 10/100 ports on the switches,
for all network connections, to PCs, servers or other end nodes, or to hubs or
other switches, you can use straight-through cables.
If any of these ports are given a fixed configuration, for example 100 Mbps/
Full Duplex, the ports operate as MDI-X ports, and straight-through cables
must be then used for connections to PC NICs and other MDI ports.
Cable Diagram
Switch Ports and Network
Cables
NotePins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired
in the cable.
.
Pin Assignments
Switch End (MDI-X)Computer, Transceiver, or NIC
End (MDI)
SignalPinsPinsSignal
receive +
receive transmit +
transmit -
1
2
3
6
1
2
3
6
transmit +
transmit receive +
receive -
B-7
Page 76
Cables
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Crossover Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connection
The HP Auto-MDIX operation of the 10/100 ports on the switches also allows
you to use crossover cables for all network connections, to PCs, servers or
other end nodes, or to hubs or other switches.
If any of these ports are given a fixed configuration, for example 100 Mbps/
Full Duplex, the ports operate as MDI-X ports, and crossover cables must be
then used for connections to hubs or switches or other MDI-X network
devices.
Cable Diagram
Switch Ports and Network
NotePins 1 and 2 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired
in the cable.
.
Pin Assignments
Switch End (MDI-X)Hub or Switch Port, or Other
MDI-X Port End
SignalPinsPinsSignal
receive +
receive transmit +
transmit -
1
2
3
6
6
3
2
1
transmit transmit +
receive receive +
B-8
Page 77
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Straight-Through Twisted-Pair Cable for
1000 Mbps Network Connections
1000Base-T connections require that all four pairs of wires be connected.
Cable Diagram
Switch Ports and Network
Cables
NotePins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 4 and 5 on connector “A” must be wired as a twisted pair to pins 4 and 5
on connector “B”.
Pins 7 and 8 on connector “A” must be wired as a twisted pair to pins 7 and 8
on connector “B”.
.
Pin Assignments
For 1000Base-T operation, all four pairs of wires are used for both transmit
and receive.
B-9
Page 78
Page 79
Safety and EMC Regulatory Statements
Safety Information
Documentation reference symbol. If the product is marked with this
!
WARNINGA WARNING in the manual denotes a hazard that can cause injury
CautionA Caution in the manual denotes a hazard that can damage equip-
symbol, refer to the product documentation to get more information
about the product.
or death.
ment.
Do not proceed beyond a WARNING or Caution notice until you
have understood the hazardous conditions and have taken appropriate steps.
C
Grounding
These are safety class I products and have protective earthing terminals. There
must be an uninterruptible safety earth ground from the main power source
to the product's input wiring terminals, power cord, or supplied power cord
set. Whenever it is likely that the protection has been impaired, disconnect
the power cord until the ground has been restored.
For LAN cable grounding:
■If your LAN covers an area served by more than one power distribu-
tion system, be sure their safety grounds are securely interconnected.
■LAN cables may occasionally be subject to hazardous transient volt-
ages (such as lightning or disturbances in the electrical utilities power
grid). Handle exposed metal components of the network with caution.
Servicing
There are no user-serviceable parts inside these products. Any servicing,
adjustment, maintenance, or repair must be performed only by service-trained
personnel.
These products do not have a power switch; they are powered on when the
power cord is plugged in.
Safety and EMC Regulatory
Statements
C-1
Page 80
Safety and EMC Regulatory Statements
Informations concernant la sécurité
Informations concernant la sécurité
WARNINGDans la documentation, un WARNING indique un danger susceptible
CautionUn texte de mise en garde intitulé Caution indique un danger suscep-
Cet appareil est un produit de classe I et possède une borne de mise à la terre. La source
d'alimentation principale doit être munie d'une prise de terre de sécurité installée aux
bornes du câblage d'entrée, sur le cordon d'alimentation ou le cordon de raccordement
fourni avec le produit. Lorsque cette protection semble avoir été endommagée,
débrancher le cordon d'alimentation jusqu'à ce que la mise à la terre ait été réparée.
Symbole de référence à la documentation. Si le produit est marqué de
!
ce symbole, reportez-vous à la documentation du produit afin d'obtenir
des informations plus détaillées.
d'entraîner des dommages corporels ou la mort.
tible de causer des dommages à l'équipement.
Ne continuez pas au-delà d'une rubrique WARNING ou Caution avant
d'avoir bien compris les conditions présentant un danger et pris les
mesures appropriées.
Mise à la terre du câble de réseau local:
■si votre réseau local s'étend sur une zone desservie par plus d'un système de
distribution de puissance, assurez-vous que les prises de terre de sécurité
soient convenablement interconnectées.
■Les câbles de réseaux locaux peuvent occasionnellement être soumis à des
surtensions transitoires dangereuses (telles que la foudre ou des perturbations dans le réseau d'alimentation public). Manipulez les composants
métalliques du réseau avec précautions.
Statements
Aucune pièce contenue à l'intérieur de ce produit ne peut être réparée par l'utilisateur.
Tout dépannage, réglage, entretien ou réparation devra être confié exclusivement à un
Safety and EMC Regulatory
personnel qualifié.
Cet appareil ne comporte pas de commutateur principal ; la mise sous tension est
effectuée par branchement du cordon d'alimentation.
C-2
Page 81
Safety and EMC Regulatory Statements
Hinweise zur Sicherheit
Hinweise zur Sicherheit
Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem
!
WARNINGSymbol für Dokumentationsverweis. Wenn das Produkt mit diesem
CautionSymbol für Dokumentationsverweis. Wenn das Produkt mit diesem
Dies ist ein Gerät der Sicherheitsklasse I und verfügt über einen schützenden Erdungsterminal. Der Betrieb des Geräts erfordert eine ununterbrochene Sicherheitserdung
von der Hauptstromquelle zu den Geräteingabeterminals, den Netzkabeln oder dem
mit Strom belieferten Netzkabelsatz voraus. Sobald Grund zur Annahme besteht, daß
der Schutz beeinträchtigt worden ist, das Netzkabel aus der Wandsteckdose herausziehen, bis die Erdung wiederhergestellt ist.
Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation
nach, um mehr Informationen über das Produkt zu erhalten.
Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation
nach, um mehr Informationen über das Produkt zu erhalten.
Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation
nach, um mehr Informationen über das Produkt zu erhalten.
Fahren Sie nach dem Hinweis WARNING oder Caution erst fort,
nachdem Sie den Gefahrenzustand verstanden und die entsprechenden Maßnahmen ergriffen haben.
Safety and EMC Regulatory
Für LAN-Kabelerdung:
■Wenn Ihr LAN ein Gebiet umfaßt, das von mehr als einem Stromverteilungs-
system beliefert wird, müssen Sie sich vergewissern, daß die
Sicherheitserdungen fest untereinander verbunden sind.
■LAN-Kabel können gelegentlich gefährlichen Übergangsspannungen aus-
gesetzt werden (beispielsweise durch Blitz oder Störungen in dem
Starkstromnetz des Elektrizitätswerks). Bei der Handhabung exponierter
Metallbestandteile des Netzwerkes Vorsicht walten lassen.
Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile. Wartungs-,
Anpassungs-, Instandhaltungs- oder Reparaturarbeiten dürfen nur von geschultem
Bedienungspersonal durchgeführt werden.
Dieses Gerät hat keinen Netzschalter; es wird beim Anschließen des Netzkabels
eingeschaltet.
Statements
C-3
Page 82
Safety and EMC Regulatory Statements
Considerazioni sulla sicurezza
Considerazioni sulla sicurezza
WARNINGLa dicitura WARNINGdenota un pericolo che può causare lesioni o
CautionLa dicituraCaution den ota un pericolo che può danneggiare le attre z-
Questo prodotto è omologato nella classe di sicurezza I ed ha un terminale protettivo
di collegamento a terra. Dev'essere installato un collegamento a terra di sicurezza, non
interrompibile che vada dalla fonte d'alimentazione principale ai terminali d'entrata,
al cavo d'alimentazione oppure al set cavo d'alimentazione fornito con il prodotto.
Ogniqualvolta vi sia probabilità di danneggiamento della protezione, disinserite il cavo
d'alimentazione fino a quando il collegaento a terra non sia stato ripristinato.
Simbolo di riferimento alla documentazione. Se il prodotto è contras-
!
segnato da questo simbolo, fare riferimento alla documentazione sul
prodotto per ulteriori informazioni su di esso.
morte.
zature.
Non procedere oltre un avviso di WARNING o di Cautionprima di aver
compreso le condizioni di rischio e aver provveduto alle misure del
caso.
Per la messa a terra dei cavi LAN:
■se la vostra LAN copre un'area servita da più di un sistema di distribuzione
elettrica, accertatevi che i collegamenti a terra di sicurezza siano ben collegati
fra loro;
■i cavi LAN possono occasionalmente andare soggetti a pericolose tensioni
transitorie (ad esempio, provocate da lampi o disturbi nella griglia d'alimen-
Statements
Safety and EMC Regulatory
tazione della società elettrica); siate cauti nel toccare parti esposte in metallo
della rete.
Nessun componente di questo prodotto può essere riparato dall'utente. Qualsiasi
lavoro di riparazione, messa a punto, manutenzione o assistenza va effettuato esclusivamente da personale specializzato.
Questo apparato non possiede un commutatore principale; si mette scotto tensione
all'inserirsi il cavo d'alimentazione.
C-4
Page 83
Safety and EMC Regulatory Statements
Consideraciones sobre seguridad
Consideraciones sobre seguridad
Símbolo de referencia a la documentación. Si el producto va
!
WARNINGUna WARNING en la documentación señala un riesgo que podría
CautionUna Caution en la documentación señala un riesgo que podría
Este aparato se enmarca dentro de la clase I de seguridad y se encuentra protegido por
una borna de puesta a tierra. Es preciso que exista una puesta a tierra continua desde
la toma de alimentación eléctrica hasta las bornas de los cables de entrada del aparato,
el cable de alimentación o el juego de cable de alimentación suministrado. Si existe la
probabilidad de que la protección a tierra haya sufrido desperfectos, desenchufar el
cable de alimentación hasta haberse subsanado el problema.
marcado con este símbolo, consultar la documentación del
producto a fin de obtener mayor información sobre el producto.
resultar en lesiones o la muerte.
resultar en averías al equipo.
No proseguir después de un símbolo de WARNING o Caution hasta
no haber entendido las condiciones peligrosas y haber tomado las
medidas apropiadas.
Puesta a tierra del cable de la red local (LAN):
■Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una
red de distribución de electricidad, cerciorarse de que las puestas a tierra
estén conectadas entre sí de modo seguro.
■Es posible que los cables de la LAN se vean sometidos de vez en cuando a
voltajes momentáneos que entrañen peligro (rayos o alteraciones en la red
de energía eléctrica). Manejar con precaución los componentes de metal de
la LAN que estén al descubierto.
Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario.
Todas las reparaciones, ajustes o servicio de mantenimiento debe realizarlos solamente el técnico.
Este producto no tiene interruptor de potencia; se activa cuando se enchufa el cable
de alimentación.
Safety and EMC Regulatory
Statements
C-5
Page 84
Safety and EMC Regulatory Statements
Safety Information (Japan)
Safety Information (Japan)
Statements
Safety and EMC Regulatory
Japan Power
Cord Warning
C-6
Page 85
Safety and EMC Regulatory Statements
Safety Information (China)
Safety Information (China)
Safety and EMC Regulatory
Statements
C-7
Page 86
Safety and EMC Regulatory Statements
EMC Regulatory Statements
EMC Regulatory Statements
U.S.A.
FCC Class A
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause interference to
radio communications. Operation of this equipment in a residential area may
cause interference in which case the user will be required to correct the
interference at his own expense.
Canada
This product complies with Class A Canadian EMC requirements.
Australia/New Zealand
This product complies with Australia/New Zealand EMC Class A
requirements.
Statements
Japan
Safety and EMC Regulatory
VCCI Class A
C-8
Page 87
Korea
Taiwan
Safety and EMC Regulatory Statements
EMC Regulatory Statements
Regulatory Model Identification Number
For regulatory identification purposes, the ProCurve
Switch 4200vl Series are assigned a Regulatory Model
Number. The Regulatory Model Number for these switches
is RSVLC-0202.
This regulatory number should not be confused with the
marketing name (ProCurve Switch 4200vl Series), or
product numbers (J8770A, J8771A, J8772A, J8773A,
J8774A, J8775A).
: HP ProCurve Switch 4204vl, 4208vl, 4208vl-64G(Bundle)
DECLARATION OF CONFORMITY
according to ISO/IEC 17050-1 and EN17050-1
1
: RSVLC-0507
conforms to the following Product Specifications and Regulations:
EMC: Class A
EN 55022:1998 +A1:2000 +A2:2003
EN 55024:1998 +A1:2001 +A2:2003
EN 61000-3-2:2000 +A2:2005
EN 61000-3-3:1995 +A1:2001
FCC CFR47 Part 15
Safety:
EN 60950:2001
IEC 60950-1:2001
EN 60825-1:1994 +A1+A2 / IEC 60825-1:1993 +A2 Class 1
Statements
Safety and EMC Regulatory
Supplementary Information:
The device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The product herewith complies with the requirements of the Low Voltage Directive 2006/95/EC, the EMC
Directive 89/336/EEC and carries the CE marking accordingly.
Additional Information:
1) This product is assigned a Regulatory Model Number which stays with the regulatory aspects of the design.
The Regulatory Model Number is the main product identifier in the regulatory documentation and test reports,
this number should not be confused with the marketing name or the product numbers.
2) This product was tested with HP branded products only.
Roseville, 14 August 2007
European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department HQ-TRE,
Herrenberger Straße 140, D-71034 Böblingen (FAX: + 49-7031-14-3143)
C-10
Page 89
Recycle Statements
Waste Electrical and Electronic
Equipment (WEEE) Statements
Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with
your other household waste. Instead, it is your responsibility to dispose of your waste equipment by
handing it over to a designated collection point for the recycling of waste electrical and electronic
equipment. The separate collection and recycling of your waste equipment at the time of disposal will
help to conserve natural resources and ensure that it is recycled in a manner that protects human health
and the environment. For more information about where you can drop off your waste equipment for
recycling, please contact your local city office, your household waste disposal service or the shop where
you purchased the product.
D
Likvidace zařízení soukromými domácími uživateli v Evropské unii
Tento symbol na produktu nebo balení označuje výrobek, který nesmí být vyhozen spolu s ostatním
domácím odpadem. Povinností uživatele je předat takto označený odpad na předem určené sběrné
místo pro recyklaci elektrických a elektronických zařízení. Okamžité třídění a recyklace odpadu
pomůže uchovat přírodní prostředí a zajistí takový způsob recyklace, který ochrání zdraví a životní
prostředí člověka. Další informace o možnostech odevzdání odpadu k recyklaci získáte na
příslušném obecním nebo městském úřadě, od firmy zabývající se sběrem a svozem odpadu nebo v
obchodě, kde jste produkt zakoupili.
Bortskaffelse af affald fra husstande i den Europæiske Union
Hvis produktet eller dets emballage er forsynet med dette symbol, angiver det, at produktet ikke må
bortskaffes med andet almindeligt husholdningsaffald. I stedet er det dit ansvar at bortskaffe kasseret
udstyr ved at aflevere det på den kommunale genbrugsstation, der forestår genvinding af kasseret
elektrisk og elektronisk udstyr. Den centrale modtagelse og genvinding af kasseret udstyr i forbindelse
med bortskaffelsen bidrager til bevarelse af naturlige ressourcer og sikrer, at udstyret genvindes på en
måde, der beskytter både mennesker og miljø. Yderligere oplysninger om, hvor du kan aflevere kasseret
udstyr til genvinding, kan du få hos kommunen, den lokale genbrugsstation eller i den butik, hvor du købte
produktet.
Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus
See tootel või selle pakendil olev sümbol näitab, et kõnealust toodet ei tohi koos teiste majapidamisjäätmetega kõrvaldada. Teie kohus on oma seadmete jäätmed kõrvaldada, viies need elektri- ja elektroonikaseadmete jäätmete ringlussevõtmiseks selleks ettenähtud kogumispunkti. Seadmete jäätmete eraldi
kogumine ja ringlussevõtmine kõrvaldamise ajal aitab kaitsta loodusvarasid ning tagada, et ringlussevõtmine toimub viisil, mis kaitseb inimeste tervist ning keskkonda. Lisateabe saamiseks selle kohta, kuhu
oma seadmete jäätmed ringlussevõtmiseks viia, võtke palun ühendust oma kohaliku linnakantselei,
majapidamisjäätmete kõrvaldamise teenistuse või kauplusega, kust Te toote ostsite.
Recycle Statements
D-1
Page 90
Recycle Statements
Έ
A
A
Waste Electrical and Electronic Equipment (WEEE) Statements
Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella
Jos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa hävittää kotitalousjätteiden mukana.
Tällöin hävitettävä laite on toimitettava sähkölaitteiden ja elektronisten laitteiden kierrätyspisteeseen.
Hävitettävien laitteiden erillinen käsittely ja kierrätys auttavat säästämään luonnonvaroja ja
varmistamaan, että laite kierrätetään tavalla, joka estää terveyshaitat ja suojelee luontoa. Lisätietoja
paikoista, joihin hävitettävät laitteet voi toimittaa kierrätettäväksi, saa ottamalla yhteyttä jätehuoltoon tai
liikkeeseen, josta tuote on ostettu.
Élimination des appareils mis au rebut par les ménages dans l'Union européenne
Le symbole apposé sur ce produit ou sur son emballage indique que ce produit ne doit pas être jeté avec
les déchets ménagers ordinaires. Il est de votre responsabilité de mettre au rebut vos appareils en les
déposant dans les centres de collecte publique désignés pour le recyclage des équipements électriques
et électroniques. La collecte et le recyclage de vos appareils mis au rebut indépendamment du reste
des déchets contribue à la préservation des ressources naturelles et garantit que ces appareils seront
recyclés dans le respect de la santé humaine et de l'environnement. Pour obtenir plus d'informations
sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités
locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous
avez acheté ce produit.
Entsorgung von Altgeräten aus privaten Haushalten in der EU
Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin, dass das Produkt nicht über den
normalen Hausmüll entsorgt werden darf. Benutzer sind verpflichtet, die Altgeräte an einer Rücknahmestelle für Elektro- und Elektronik-Altgeräte abzugeben. Die getrennte Sammlung und ordnungsgemäße Entsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei und garantiert
eine Wiederverwertung, die die Gesundheit des Menschen und die Umwelt schützt. Informationen dazu,
wo Sie Rücknahmestellen für Ihre Altgeräte finden, erhalten Sie bei Ihrer Stadtverwaltung, den örtlichen
Müllentsorgungsbetrieben oder im Geschäft, in dem Sie das Gerät erworben haben
Απόρριψη άχρηστου εξοπλισμού από χρήστες σε ιδιωτικά νοικοκυριά στην Ευρωπαϊκή
νωση
Το σύμβολο αυτό στο προϊόν ή τη συσκευασία του υποδεικνύει ότι το συγκεκριμένο προϊόν δεν
πρέπει να διατίθεται μαζί με τα άλλα οικιακά σας απορρίμματα. Αντίθετα, είναι δική σας ευθύνη να
απορρίψετε τον άχρηστο εξοπλισμό σας παραδίδοντάς τον σε καθορισμένο σημείο συλλογής για την
ανακύκλωση άχρηστου ηλεκτρικού και ηλεκτρονικού εξοπλισμού
ανακύκλωση του άχρηστου εξοπλισμού σας κατά την απόρριψη θα συμβάλει στη διατήρηση των
φυσικών πόρων και θα διασφαλίσει ότι η ανακύκλωση γίνεται με τρόπο που προστατεύει την
ανθρώπινη υγεία και το περιβάλλον. Για περισσότερες πληροφορίες σχετικά με το πού μπορείτε να
παραδώσετε τον άχρηστο εξοπλισμό σας
γραφείο, την τοπική υπηρεσία διάθεσης οικιακών απορριμμάτων ή το κατάστημα όπου αγοράσατε το
προϊόν.
Készülékek magánháztartásban történő selejtezése az Európai Unió területén
készüléken, illetve a készülék csomagolásán látható azonos szimbólum annak jelzésére szolgál,
hogy a készülék a selejtezés során az egyéb háztartási hulladéktól eltérő módon kezelendő. A
vásárló a hulladékká vált készüléket köteles a kijelölt gyűjtőhelyre szállítani az elektromos és
elektronikai készülékek újrahasznosítása céljából. A hulladékká vált készülékek selejtezéskori
begyűjtése és újrahasznosítása hozzájárul a természeti erőforrások megőrzéséhez, valamint
biztosítja a selejtezett termékek környezetre és emberi egészségre nézve biztonságos feldolgozását.
begyűjtés pontos helyéről bővebb tájékoztatást a lakhelye szerint illetékes önkormányzattól, az
Recycle Statements
illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat.
γιαανακύκλωση, επικοινωνήστεμετοαρμόδιοτοπικό
. Η ξεχωριστή συλλογή και
D-2
Page 91
Recycle Statements
A
V
Waste Electrical and Electronic Equipment (WEEE) Statements
Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea
Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere
smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le apparecchiature consegnandole presso un punto di raccolta designato al riciclo e allo smaltimento di apparecchiature elettriche ed
elettroniche. La raccolta differenziata e il corretto riciclo delle apparecchiature da smaltire permette di
proteggere la salute degli individui e l'ecosistema. Per ulteriori informazioni relative ai punti di raccolta
delle apparecchiature, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il
quale è stato acquistato il prodotto.
Nolietotu iekārtu iznīcināšanas noteikumi lietotājiem Eiropas Savienības privātajās
mājsaimniecībās
Šāds simbols uz izstrādājuma vai uz tā iesaiņojuma norāda, ka šo izstrādājumu nedrīkst izmest kopā ar
citiem sadzīves atkritumiem. Jūs atbildat par to, lai nolietotās iekārtas tiktu nodotas speciāli iekārtotos
punktos, kas paredzēti izmantoto elektrisko un elektronisko iekārtu savākšanai otrreizējai pārstrādei.
tsevišķa nolietoto iekārtu savākšana un otrreizējā pārstrāde palīdzēs saglabāt dabas resursus un
garantēs, ka šīs iekārtas tiks otrreizēji pārstrādātas tādā veidā, lai pasargātu vidi un cilvēku veselību.
Lai uzzinātu, kur nolietotās iekārtas var izmest otrreizējai pārstrādei, jāvēršas savas dzīves vietas
pašvaldībā, sadzīves atkritumu savākšanas dienestā vai veikalā, kurā izstrādājums tika nopirkts.
artotojų iš privačių namų ūkių įrangos atliekų šalinimas Europos Sąjungoje
Šis simbolis ant gaminio arba jo pakuotės rodo, kad šio gaminio šalinti kartu su kitomis namų ūkio
atliekomis negalima. Šalintinas įrangos atliekas privalote pristatyti į specialią surinkimo vietą elektros ir
elektroninės įrangos atliekoms perdirbti. Atskirai surenkamos ir perdirbamos šalintinos įrangos atliekos
padės saugoti gamtinius išteklius ir užtikrinti, kad jos bus perdirbtos tokiu būdu, kuris nekenkia žmonių
sveikatai ir aplinkai. Jeigu norite sužinoti daugiau apie tai, kur galima pristatyti perdirbtinas įrangos
atliekas, kreipkitės į savo seniūniją, namų ūkio atliekų šalinimo tarnybą arba parduotuvę, kurioje įsigijote gaminį.
Verwijdering van afgedankte apparatuur door privé-gebruikers in de Europese Unie
Dit symbool op het product of de verpakking geeft aan dat dit product niet mag worden gedeponeerd bij
het normale huishoudelijke afval. U bent zelf verantwoordelijk voor het inleveren van uw afgedankte
apparatuur bij een inzamelingspunt voor het recyclen van oude elektrische en elektronische apparatuur.
Door uw oude apparatuur apart aan te bieden en te recyclen, kunnen natuurlijke bronnen worden
behouden en kan het materiaal worden hergebruikt op een manier waarmee de volksgezondheid en het
milieu worden beschermd. Neem contact op met uw gemeente, het afvalinzamelingsbedrijf of de winkel
waar u het product hebt gekocht voor meer informatie over inzamelingspunten waar u oude apparatuur
kunt aanbieden voor recycling.
Pozbywanie się zużytego sprzętu przez użytkowników w prywatnych gospodarstwach
domowych w Unii Europejskiej
Ten symbol na produkcie lub jego opakowaniu oznacza, że produktu nie wolno wyrzucać do zwykłych
pojemników na śmieci. Obowiązkiem użytkownika jest przekazanie zużytego sprzętu do
wyznaczonego punktu zbiórki w celu recyklingu odpadów powstałych ze sprzętu elektrycznego i
elektronicznego. Osobna zbiórka oraz recykling zużytego sprzętu pomogą w ochronie zasobów
naturalnych i zapewnią ponowne wprowadzenie go do obiegu w sposób chroniący zdrowie człowieka
i środowisko. Aby uzyskać więcej informacji o tym, gdzie można przekazać zużyty sprzęt do
recyklingu, należy się skontaktować z urzędem miasta, zakładem gospodarki odpadami lub sklepem,
w którym zakupiono produkt.
Recycle Statements
D-3
Page 92
Recycle Statements
Waste Electrical and Electronic Equipment (WEEE) Statements
Descarte de Lixo Elétrico na Comunidade Européia
Este símbolo encontrado no produto ou na embalagem indica que o produto não deve ser descartado
no lixo doméstico comum. É responsabilidade do cliente descartar o material usado (lixo elétrico),
encaminhando-o para um ponto de coleta para reciclagem. A coleta e a reciclagem seletivas desse
tipo de lixo ajudarão a conservar as reservas naturais; sendo assim, a reciclagem será feita de uma
forma segura, protegendo o ambiente e a saúde das pessoas. Para obter mais informações sobre locais
que reciclam esse tipo de mate rial, entre em contato c om o escritório da HP em sua cidade, com o serviço
de coleta de lixo ou com a loja em que o produto foi adquirido.
Likvidácia vyradených zariadení v domácnostiach v Európskej únii
Symbol na výrobku alebo jeho balení označuje, že daný výrobok sa nesmie likvidovať s domovým
odpadom. Povinnosťou spotrebiteľa je odovzdať vyradené zariadenie v zbernom mieste, ktoré je
určené na recykláciu vyradených elektrických a elektronických zariadení. Separovaný zber a
recyklácia vyradených zariadení prispieva k ochrane prírodných zdrojov a zabezpečuje, že recyklácia
sa vykonáva spôsobom chrániacim ľudské zdravie a životné prostredie. Informácie o zberných
miestach na recykláciu vyradených zariadení vám poskytne miestne zastupiteľstvo, spoločnosť
zabezpečujúca odvoz domového odpadu alebo obchod, v ktorom ste si výrobok zakúpili.
Odstranjevanje odslužene opreme uporabnikov v zasebnih gospodinjstvih v Evropski uniji
Ta znak na izdelku ali njegovi embalaži pomeni, da izdelka ne smete odvreči med gospodinjske
odpadke. Nasprotno, odsluženo opremo morate predati na zbirališče, pooblaščeno za recikliranje
odslužene električne in elektronske opreme. Ločeno zbiranje in recikliranje odslužene opreme
prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju neškodljiv
način. Za podrobnejše informacije o tem, kam lahko odpeljete odsluženo opremo na recikliranje, se
obrnite na pristojni organ, komunalno službo ali trgovino, kjer ste izdelek kupili.
Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la
Unión Europea
Este símbolo en el producto o en su envase indica que no debe eliminarse junto con los desperdicios
generales de la casa. Es responsabilidad del usuario eliminar los residuos de este tipo depositándolos
en un "punto limpio" para el reciclado de residuos eléctricos y electrónicos. La recogida y el reciclado
selectivos de los residuos de aparatos eléctricos en el momento de su eliminación contribuirá a
conservar los recursos naturales y a garantizar el reciclado de estos residuos de forma que se proteja
el medio ambiente y la salud. Para obtener más información sobre los puntos de recogida de residuos
eléctricos y electrónicos para reciclado, póngase en contacto con su ayuntamiento, con el servicio de
eliminación de residuos domésticos o con el establecimiento en el que adquirió el producto.
Bortskaffande av avfallsprodukter från användare i privathushåll inom Europeiska Unionen
Om den här symbolen visas på produkten eller förpackningen betyder det att produkten inte får
slängas på samma ställe som hushållssopor. I stället är det ditt ansvar att bortskaffa avfallet genom att
överlämna det till ett uppsamlingsställe avsett för återvinning av avfall från elektriska och elektroniska
produkter. Separat insamling och återvinning av avfallet hjälper till att spara på våra naturresurser och
gör att avfallet återvinns på ett sätt som skyddar människors hälsa och miljön. Kontakta ditt lokala
kommunkontor, din närmsta återvinningsstation för hushållsavfall eller affären där du köpte produkten
för att få mer information om var du kan lämna ditt avfall för återvinning.
Recycle Statements
D-4
Page 93
Index
Numerics
10/100/1000Base-T
connections, length limitations … 2-6
note on cable requirements … B-2
ports, cables used with … 2-6, B-2
twisted-pair cable specifications … B-2
1000Base-LH
connections, length limitations … 2-6
ports, cables used with … 2-6
1000Base-LX
connections, length limitations … 2-6
ports, cables used with … 2-6
1000Base-SX
connections, length limitations … 2-6
ports, cables used with … 2-6
100Base-TX
ports, cables used with … B-2
twisted-pair cable specifications … B-2
10Base-T
ports, cables used with … B-2
twisted-pair cable specifications … B-2
A
Act LED … 1-7, 1-8
aggregation switch, example topology as … 2-26
auto MDI/MDI-X operation … B-7, B-9
HP Auto MDI-X feature … B-5
auxilary port … 1-5
B
back of switch
description … 1-10
power connector … 1-10
slot for redundant power supply … 1-10
connecting to a power source … 2-19
description … 1-1
electrical specifications … A-1
environmental specifications … A-2
features … 1-11
Index
front panel description … 1-5
included parts … 2-1
mounting in a rack or cabinet … 2-14
mounting on a horizontal surface … 2-17
mounting on a wall … 2-18
physical specifications … A-1
switch chassis
LED descriptions … 1-6
switch modules
booting the switch to initialize changed module
type … 2-8
hot swapping … 2-22
installing … 2-8
LEDs descriptions … 1-7
list of available types … 1-4
switch operation
verifying after installation … 2-12
switch ports
location on switch … 1-5
Switch Setup screen … 3-2
configuring a subnet mask … 3-3
configuring an IP address … 3-3
field descriptions … 3-3
T
telnet access to the console … 2-21, 3-5
terminal configuration … 2-20
testing
checking the console messages … 4-11
checking the LEDs … 4-11
diagnostic tests … 4-11
end-to-end communications … 4-12
link test … 4-12
Ping test … 4-12
switch operation … 4-11
switch-to-device communications … 4-12
twisted-pair cabling … 4-12
tips for troubleshooting … 4-2
topologies
effects of improper topology … 4-2
examples of
as a legacy connectivity switch … 2-24
as an aggregation switch … 2-26
as an edge switch … 2-25