HP 12500, 12508, 12518 Quickspecs

Page 1
Product overview
The HP 12500 Switch Series is a family of powerful, next-generation routing switches with outstanding capacity and scale for the network core or data center.
Designed for high performance with nonblocking and distributed Clos architecture, these switches deliver up to 24.3 Tbps switching capacity and 10.8 Bpps throughput with up to 400 Gbps per line card slot.
The 12500 switches also have energy-efficiency features that drive down operational expenses and are ideal for organizations contemplating large-scale data center consolidations, business continuity and disaster recovery sites, metropolitan area network deployments, and other applications requiring a robust, reliable and highly available switching platform.
HP 12508 Switch HP 12518 Switch
QuickSpecs
HP 12500 Switch Series
Overview
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 1
Page 2
Key features
Optimized for cata centers with extensive virtualization and convergence featured Broad interface options from 1G to 100G scaling up to 24.3 Tbps switching capacity SDN ready with Open Flow 1.3 support Large Layer 2 and Layer 3 tables to support large scale deployments Fully redundant architecture with hot swappable components
Features and benefits
Data center optimized
NEW Scalable Layer 2 fabrics
build flexible, resilient, and scalable Layer 2 fabrics with SPB and HP IRF
Multitenant Device Context (MDC)
is an innovative data center virtualization solution that enables multi-tenancy, giving customers the ability to virtualize a physical switch into multiple logical devices, with each logical switch having its own tenants
HP Ethernet Virtual Interconnect (EVI)
is an HP Virtual Application Network innovation that provides a Layer 2 extension across the data center to simplify the interconnectivity of geographically disperse data centers
NEW Data Center Bridging (DCB) protocols
provide support for IEEE 802.1Qaz Data Center Bridging Exchange (DCBX), Enhanced Transmission Selection (ETS), and IEEE
802.1Qbb Priority Flow Control (PFC) for converged fabrics
NEW Fibre Channel over Ethernet (FCoE) features
deliver support for FCoE, including expansion, fabric, trunk VF and N ports, and aggregation of E-port and N-port virtualization
Accelerated perfomance with jumbo frames
for intra-data-center communication, or for data center to data center traffic (disaster recovery), reducing the amount of time required for data backup and recovery
Network load balancing (NLB) multicast ARP
Microsoft® NLB co-works with multicast ARP to provide servers with load balancing and fault switchover, which lowers costs and investment
Software-defined networking
NEW Supports OpenFlow 1.3 specifications
to enable SDN by allowing separation of the data (packet forwarding) and control (routing decision) paths
Performance
NEW High performance design with nonblocking and distributed Clos architecture
delivers up to 24.3 Tbps switching capacity and 10.8 Bpps throughput with up to 400 Gbps per line card slot
NEW High-density 1GbE,10GbE and 40GbE interface connectivity
offers up to 18 interface module slots to scale up to 864 1GbE and 1/10GbE and 288 40GbE ports
Hardware-based wirespeed access control lists (ACLs)
help provide high levels of security and ease of administration without impacting network performance with a feature-rich TCAM-based ACL implementation
High-performance processor system
the supervisor module uses three different processors to isolate key tasks: control plane (STP, OSPF, BGP, MPLS, etc.), fast recovery protocols (RRPP, BFD, etc.), and chassis management (temperature, power, etc.)
Product architecture
QuickSpecs
HP 12500 Switch Series
Overview
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 2
Page 3
Distributed architecture with separation of data and control planes
delivers enhanced fault tolerance and facilitates continuous operation and zero service disruption during planned or unplanned control-plane events
Advanced Comware modular operating system
brings modularity, enhanced serviceability, stability and independent process monitoring through modern Comware v7 Operating System
In-Service Software Upgrade (ISSU)
provides an upgrade of the entire chassis, or an individual task or process, with zero packet loss
Resiliency and high availability
Intelligent Resilient Framework (IRF)
creates virtual resilient switching fabrics, where two or more switches perform as a single L2 switch and L3 router; switches do not have to be co-located and can be part of a disaster-recovery system; servers or switches can be attached using standard LACP for automatic load balancing and high availability; can eliminate the need for complex protocols like Spanning Tree Protocol, Equal-Cost Multipath (ECMP), or VRRP, thereby simplifying network operation
Ultrafast protocol convergence
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and IRF
Device Link Detection Protocol (DLDP)
monitors link connectivity and shuts down ports at both ends if unidirectional traffic is detected, preventing loops in STP-based networks
Complete set of routing protocols (Layer 3 IPv4 and IPv6)
support virtually all existing routing protocols (RIP, OSPF, IS-IS, and BGP) for both Layer 3 IPv4 and Layer 3 IPv6; complete support of PIM-DM, PIM-SM, PIM-SSM, and MSDP
Hot patching
the 12500 switch series supports hot patching, allowing in-service patching for some isolated software problems
Non Stop Forwarding/Graceful Restart (NSF/GR)
using standardized-based IETF protocols, the 12500 switch series provides nonstop forwarding (switching/routing) for Layer 3 routing protocols (control plane – OSPF, BGP, and MPLS), providing hitless failover
Fully redundant and hot swappable components
providing full hardware redundancy for each component including power supplies, fan trays, supervisor modules and fabric modules to enable the highest level of availability
Rapid Ring Protection Protocol (RRPP)
provides fast recovery for ring Ethernet-based topology
Quality of Service (QoS)
Virtual Output Queue (VOQ)
prevents head-of-line (HOL) blocking per port at peak time and distributes it over a period of time, increasing switch performance
IEEE 802.1p prioritization
delivers data to devices based on the priority and type of traffic
Layer 4 prioritization
enables prioritization based on TCP/UDP port numbers
Broadcast control
allows limitation of broadcast traffic rate to cut down on unwanted network broadcast traffic
Advanced classifier-based QoS
classifies traffic using multiple match criteria based on Layer 2, 3, and 4 information; applies QoS policies such as setting priority level and rate limit to selected traffic on a per-port or per-VLAN basis
Bandwidth shaping
QuickSpecs
HP 12500 Switch Series
Overview
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 3
Page 4
Port-based rate limiting
provides per-port ingress-/egress-enforced maximum bandwidth
Classifier-based rate limiting
uses access control lists (ACLs) to enforce maximum bandwidth for ingress/egress traffic on each port
Compartmentalization
Department protection
using network virtualization standards (QinQ, VRF, and MPLS), the 12500 switch series allows organizations to isolate different business units with different resources (VRFs); using standard-based mechanisms, the network is completely virtualized, reducing cost and operations
IEEE 802.1ah Provider Backbone Bridge (MAC in MAC)
Provider Backbone Bridge (PBB) is a Layer 2 VPN technology that allows a complete separation of customer and provider domains by sealing the user MAC in the service provider MAC, which enhances the scalability of an Ethernet network
Layer 2 switching
Multiple VLAN Registration Protocol (MVRP)
helps to maintain VLAN configuration dynamically based on current network configurations
GARP VLAN Registration Protocol
allows automatic learning and dynamic assignment of VLANs
IP multicast snooping and data-driven IGMP
automatically prevents flooding of IP multicast traffic
IEEE 802.1ad QinQ
increases the scalability of an Ethernet network by providing a hierarchical structure; connects multiple LANs on a high-speed campus or metro network
Bridge Protocol Data Unit (BPDU) tunneling
transmits Spanning Tree Protocol BPDUs transparently, allowing correct tree calculations across service providers, WANs, or MANs
VLAN support and tagging
supports IEEE 802.1Q (4K VLAN IDs)
Spanning Tree
the 12500 switch series supports the entire set of STP protocols (STP, RSTP, and MSTP), facilitating a complete integration with standard networks
Layer 3 routing
Layer 3 IPv4 routing
provides routing of IPv4 at media speed; supports static routes, RIP and RIPv2, OSPF, IS-IS, and BGP
RIP and RIPng support
provides complete support of RIP for both IPv4 and IPv6
OSPF and OSPFv3 support
provides complete support of OSPF for both IPv4 and IPv6
IS-IS and IS-ISv6 support
provides complete support of IS-IS for both IPv4 and IPv6
Equal-Cost Multipath (ECMP)
enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth
Layer 3 IPv6 routing
provides routing of IPv6 at media speed; supports static routes, RIPng, OSPFv3, IS-ISv6, and BGP4+
IPv6 tunneling
allows a smooth transition from IPv4 to IPv6 by encapsulating IPv6 traffic over an existing IPv4 infrastructure
QuickSpecs
HP 12500 Switch Series
Overview
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 4
Page 5
Complete multicast protocol stack
PIM-DM, PIM-SM, PIM-SSM, MSDP, and extensions to BGP provide one of the most complete multicast protocol stacks
Policy routing
allows custom filters for increased performance and security; supports ACLs, IP prefix, AS paths, community lists, and aggregate policies
MPLS support
provides extended support of MPLS, including MPLS VPNs and MPLS Traffic Engineering (MPLS TE)
VPLS support
provides extended support of VPLS for data center to data center communication at Layer 2; provides support of hierarchical VPLS for scalability
Management
sFlow
provides scalable, ASIC-based network monitoring and accounting; this allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and real-time network monitoring purposes
IEEE 802.1ab LLDP discovery
advertises and receives management information from adjacent devices on a network, facilitating easy mapping by network management applications
USB support
File copy
allows users to copy switch files to and from a USB flash drive
Multiple configuration files
can be stored to the flash image
Command-line interface (CLI)
provides a secure, easy-to-use CLI for configuring the module via SSH or a switch console; provides direct real-time session visibility
Logging
provides local and remote logging of events via SNMP (v2c and v3) and syslog; provides log throttling and log filtering to reduce the number of log events generated
Management interface control
each of the following interfaces can be enabled or disabled depending on security preferences: console port, telnet port, and SSH port
Out-of-band interface
isolates management traffic from user data plane traffic for complete isolation and total reachability, no matter what happens in the data plane
Network management
Intelligent Management Console (IMC) centrally configures, updates, monitors, and troubleshoots
Network management
SNMP v2c/v3 MIB-II with traps
RADIUS accounting
logs all session details that can be used to generate usage reports or interface to a billing system
RMON
provides advanced monitoring and reporting capabilities for statistics, history, alarms, and events
Remote Intelligent Mirroring
mirrors ingress ACL-selected traffic from a switch port or VLAN to a local or remote switch port anywhere on the network
Connectivity
IPv6 native support
:
QuickSpecs
HP 12500 Switch Series
Overview
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 5
Page 6
IPv6 host
enables switches to be managed and deployed at the IPv6 network's edge
Dual stack (IPv4 and IPv6)
transitions from IPv4 to IPv6, supporting connectivity for both protocols
Multicast Listener Discovery (MLD) snooping
forwards IPv6 multicast traffic to the appropriate interface
IPv6 ACL/QoS
supports ACL and QoS for IPv6 network traffic, preventing traffic flooding
IPv6 routing
supports IPv6 static routes and IPv6 versions of RIP and OSPF routing protocols
Security
Control Plane Policing (CoPP)
provides protection against DoS attacks at infrastructure routers and switches and ease of configuration for control plane policies
IEEE 802.1X and RADIUS network logins
control port-based access for authentication and accountability
Secure FTP
allows secure file transfer to and from the switch; protects against unwanted file downloads or unauthorized copying of a switch configuration file
Switch management logon security
can require either RADIUS or TACACS+ authentication for secure switch CLI logon
DHCP protection
blocks DHCP packets from unauthorized DHCP servers, preventing denial-of-service attacks
Dynamic ARP protection
blocks ARP broadcasts from unauthorized hosts, preventing eavesdropping or theft of network data
Secure Shell (SSHv2)
encrypts all transmitted data for secure, remote CLI access over IP networks
Secure management access
securely encrypts all access methods (CLI, GUI, or MIB) through SSHv2 and SNMPv3
Access control lists (ACLs)
provide IPv4 and IPv6 filtering based on source/destination IP address/subnet and source/destination TCP/UDP port number
Media access control (MAC) authentication
provides simple authentication based on a user's MAC address; supports local or RADIUS-based authentication
Convergence
Layer 2, 3, and 4 QoS mechanisms
support DiffServ priority tagging based on IP address, IP Type of Service (ToS), Layer 3 protocol, TCP/UDP port number, and source port
IP multicast snooping and data-driven IGMP
automatically prevent flooding of IP multicast traffic
LLDP-MED
is a standard extension that automatically configures network devices, including LLDP-capable IP phones
Internet Group Management Protocol (IGMP)
is used by IP hosts to establish and maintain multicast groups; supports IGMPv1, v2, and v3; utilizes Any-Source Multicast (ASM) or Source-Specific Multicast (SSM) to manage IPv4 multicast networks
Protocol Independent Multicast (PIM)
is used for IPv4 and IPv6 multicast applications; supports PIM Dense Mode (PIM-DM), Sparse Mode (PIM-SM), and Source-Specific
QuickSpecs
HP 12500 Switch Series
Overview
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 6
Page 7
Mode (PIM-SSM)
Multicast Source Discovery Protocol (MSDP)
is used for inter-domain multicast applications, allowing multiple PIM-SM domains to interoperate
Multicast VLAN
allows multiple VLANs to receive the same IPv4 or IPv6 multicast traffic, lessening network bandwidth demand by reducing or eliminating multiple streams to each VLAN
Monitor and diagnostics
Port mirroring
enables traffic on a port to be simultaneously sent to a network analyzer for monitoring
Connectivity fault detection (IEEE 802.1ag)
connectivity fault detection (CFD) provides a Layer 2 link Operations, Administration, and Maintenance (OAM) mechanism used for link connectivity detection and fault locating
Integration
12500 VPN 20 Gb/s Firewall Module
provides enhanced stateful packet inspection and filtering; supports flexible security zones and virtual firewall containment; delivers advanced VPN services with 3DES and AES encryption at high performance and low latency; offers Web content filtering and application prioritization and optimization
Investment protection
Modular switch fabric
provides investment protection by enabling future performance upgrades and increased port density
Environmentally friendly
ROHS support and low power consumption based on the latest technology provide outstanding power efficiency
Warranty and support
1-year warranty
with advance replacement and 10-calendar-day delivery (available in most countries)
Electronic and telephone support
limited electronic and business-hours telephone support is available from HP for the entire warranty period; to reach our support centers, refer to
www.hp.com/networking/contact-support
; for details on the duration of support provided with your
product purchase, refer to
www.hp.com/networking/warrantysummary
Software releases
to find software for your product, refer to
www.hp.com/networking/support
; for details on the software releases available
with your product purchase, refer to
www.hp.com/networking/warrantysummary
QuickSpecs
HP 12500 Switch Series
Overview
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 7
Page 8
Build To Order:
BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or Rack-Shippable solution.
HP 12504 AC Switch Chassis
JC654A
2 - MPUx (Management Ports) 4 - I/O module slots 4 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply Must select min 1 PEM Must select Min 1 Fans Must select Min 4 Fabric Modules 10U - Height Rack
HP 12504 DC Switch Chassis
JC655A
2 - MPUx (Management Ports) 4- I/O module slots 4 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply 1 PEM included Must select Min 1 Fans Must select Min 4 Fabric Modules 10U - Height Rack
HP 12508 AC Switch Chassis
JF431C
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply Must select min 1 PEM Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
HP FlexFabric 12508E AC Switch Chassis
JG782A
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply PEM included Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
See Configuration
Note:1
PDU Cable NA/MEX/TW/JP
JG782A#B2B
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 8
Page 9
C19 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JG782A#B2C
C19 PDU Jumper Cord (ROW)
High Volt Power Entry Module to Wall Power Cord
JG782A#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HP 12508 DC Switch Chassis
JC652A
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply 1 PEM included Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
HP FlexFabric 12508E DC Switch Chassis
JG783A
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply PEM included Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
HP 12518 AC Switch Chassis
JF430C
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply Must select min 2 PEM Must select min 2 Fans Must select Min 8 Fabric Modules 38U - Height Rack
HP FlexFabric 12518E AC Switch Chassis
JG784A
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply PEM included Must select min 2 Fans
See Configuration
Note:1
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 9
Page 10
Must select Min 8 Fabric Modules 38U - Height Rack
PDU Cable NA/MEX/TW/JP
JG784A#B2B
C19 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JG784A#B2C
C19 PDU Jumper Cord (ROW)
High Volt Power Entry Module to Wall Power Cord
JG784A#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HP 12518 DC Switch Chassis
JC653A
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply 2 PEM included Must select min 2 Fans Must select Min 8 Fabric Modules 38U - Height Rack
HP FlexFabric 12518E DC Switch Chassis
JG785A
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply PEM included Must select min 2 Fans Must select Min 8 Fabric Modules 38U - Height Rack
Configuration Rules:
Note 1
Localization required on orders without #B2B, #B2C or #B2E options.
Box Level Integration CTO Models
CTO Solution Sku
HP 125xx CTO Switch Solution
JG477A
SSP trigger sku
CTO Switch Chassis
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 10
Page 11
HP 12504 AC Switch Chassis
JC654A
2 - MPUx (Management Ports) 4 - I/O module slots 4 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply Must select min 1 PEM Must select Min 1 Fans Must select Min 4 Fabric Modules 10U - Height Rack
See Configuration
Note:1, 2
HP 12504 DC Switch Chassis
JC655A
2 - MPUx (Management Ports) 4- I/O module slots 4 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply 1 PEM included Must select Min 1 Fans Must select Min 4 Fabric Modules 10U - Height Rack
See Configuration
Note:2, 3
Configuration Rules:
Note 1
If this Switch is selected at least one of these Power Supply is required: (Use #0D1 if switch is CTO) JF429A - HP 12500 2000W AC Power Supply
Note 2
If the Switch Chassis is to be Box Level Factory Integrated (CTO)), Then the #0D1 is required on the Switch Chassis and integrated to the JG477A - HP 125xx CTO Switch Solution (Min 1/Max 1 Switch per SSP)
Note 3
If this Switch is selected at least one of these Power Supplies is required: (Use #0D1 if switch is CTO) JC651A - HP 12500 1800W DC Power Supply
Rack Level Integration CTO Models
HP 12504 AC Switch Chassis
JC654A
2 - MPUx (Management Ports) 4 - I/O module slots 4 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply Must select min 1 PEM Must select Min 1 Fans Must select Min 4 Fabric Modules 10U - Height Rack
See Configuration
Note:1, 2, 3
HP 12504 DC Switch Chassis
JC655A
2 - MPUx (Management Ports)
See Configuration
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 11
Page 12
4 - I/O module slots 4 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply 1 PEM included Must select Min 1 Fans Must select Min 4 Fabric Modules 10U - Height Rack
Note: 3, 4
HP 12508 AC Switch Chassis
JF431C
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply Must select min 1 PEM Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
See Configuration
Note:1, 2, 3
HP FF 12508E AC Switch Chassis
JG782A
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply PEM included Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
See Configuration
Note:1, 3, 5
PDU Cable NA/MEX/TW/JP
JG782A#B2B
C19 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JG782A#B2C
C19 PDU Jumper Cord (ROW)
HP 12508 DC Switch Chassis
JC652A
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply 1 PEM included Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
See Configuration
Note: 3, 4
HP FF 12508E DC Switch Chassis
JG783A
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 12
Page 13
2 - MPUx (Management Ports) 8- I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 3 Power Supply PEM included Must select Min 2 Fans Must select Min 8 Fabric Modules 22U - Height Rack
See Configuration
Note: 3, 4
HP 12518 AC Switch Chassis
JF430C
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply Must select min 2 PEM Must select min 2 Fans Must select Min 8 Fabric Modules 38U - Height Rack
See Configuration
Note:1, 2, 3
HP FF 12518E AC Switch Chassis
JG784A
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply PEM included Must select min 2 Fans Must select Min 8 Fabric Modules 38U - Height Rack
See Configuration
Note:1, 3, 5
PDU Cable NA/MEX/TW/JP
JG784A#B2B
C19 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JG784A#B2C
C19 PDU Jumper Cord (ROW)
HP 12518 AC Switch Chassis
JC653A
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply 2 PEM included Must select min 2 Fans Must select Min 8 Fabric Modules 38U - Height Rack
See Configuration
Note: 3, 4
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 13
Page 14
HP FF 12518E DC Switch Chassis
JG785A
2 - MPUx (Management Ports) 18 - I/O module slots 9 - Fabric module slots Must select min 1 Management Module Must select min 6 Power Supply PEM included Must select min 2 Fans Must select Min 8 Fabric Modules 38U - Height Rack
See Configuration
Note: 3, 4
Configuration Rules:
Note 1
If this Switch is selected at least one of these Power Supply is required: (Use #0D1 if switch is CTO) JF429A - HP 12500 2000W AC Power Supply
Note 2
When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be the Defaulted Power Cable option on the Power Electrical Module. (See Drop down remark in the "Internal Power Supplies" section.)
Note 3
If HP CTO Switch Chassis is selected to be Rack Level Integration, Then the CTO Switch Chassis needs to integrate (with #0D1) to the BW966A or BW968A HP Universal Rack Only. (Default to the BW966A.)
Note 4
If this Switch is selected at least one of these Power Supplies is required: (Use #0D1 if switch is CTO) JC651A - HP 12500 1800W DC Power Supply
Note 5
Localization required on orders without #B2B or #B2C options.
Internal Power Supplies
12508 and 12504 - System (std 0 // max 6) User Selection (min 3 // max 6)
12508E - System (std 0 // max 8) User Selection (min 3 // max 8)
12518 - System (std 0 // max 12) User Selection (min 6 // max 12)
12518E - System (std 0 // max 16) User Selection (min 6 // max 16)
HP 12500 2000W AC Power Supply
JF429A
See Configuration
Note:1
HP 12500 1800W DC Power Supply
JC651A
See Configuration
Note:2
Configuration Rules:
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 14
Page 15
Note 1
Supported on Switches JC654A, JF431C, JF430C, JG782A and JG784A only.
Note 2
Supported on Switches JC655A, JC652A, JC653A, JG783A and JG785A only.
Remarks:
12504 and 12508 only - Default 6 power supplies and allow the user to change down to 3.
12508E only - Default 6 power supplies and allow the user to change down to 3.
12518 only - Default 12 power supplies and allow the user to change down to 6.
12518E only - Default 12 power supplies and allow the user to change down to 6.
The power module support load balancing and N+1/N+M redundancy. Deploying N+1 power redundancy The total number of power modules (JF431C, JF430C) = Ceiling (total power load of the chassis/2000) + 1 For example, if the total load of the chassis is 3000 W, the number of power modules must be 2 + 1 = 3. Deploying 1:1 power redundancy JF431C-Requires 6 power modules. JF430C-Total number of power modules = [Ceiling (total power load of the chassis/2000) ] x 2 For example, if the total power load of the chassis is 7000 W, the total number of power modules must be (4 + 1) x 2 = 10.
Localization is not required on these internal AC power supplies. Localization is covered on the chassis for the 125x8E AC models (JG782A, JG784A), or on the PEMs listed below for the AC 125xx models (JC654A, JF431C, JF430C).
Localization
HP 12500 AC Power Entry Module - Chile - English localization
JF426A#A1X
Power Cord: Quantity :6, CEI 23-50, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8121-0923
HP 12500 AC Power Entry Module - U.S. - English localization
JF426A#ABA
Power Cord: Quantity :6, NEMA 5-20P, C19 STRAIGHT, 125 V, 15 A, 2.5 meters, 8.21 feet, Store Part# :8120­6361
HP 12500 AC Power Entry Module - Europe - English localization
JF426A#ABA
Power Cord: Quantity :6, NEMA 6-20P / L6-20P, C19 STRAIGHT, 250 V, 20 A, 2.5 meters, 8.21 feet, Store Part# :8120-6360
HP 12500 AC Power Entry Module - Europe - English localization
JF426A#ABB
Power Cord: Quantity :6, CEE 7-VII, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8120-6352
HP 12500 AC Power Entry Module - Australia - English localization
JF426A#ABG
Power Cord: Quantity :6, AS/NZS 3112, C19 STRAIGHT, 250 V, 15 A, 2.5 meters, 8.21 feet, Store Part# :8120­6351
HP 12500 AC Power Entry Module - Brazil - Portuguese localization
JF426A#AC4
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 15
Page 16
Power Cord: Quantity :6, NBR 14136 Fig13, C19 STRAIGHT, 250 V, 2.5 A, 2.5 meters, 8.21 feet, Store Part# :8121-1101
HP 12500 AC Power Entry Module - Korea - English localization
JF426A#AC6
Power Cord: Quantity :6, CEE 7-VII, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8120-6352
HP 12500 AC Power Entry Module - United Kingdom - English localization
JF426A#ACC
Power Cord: Quantity :6, BS 1363/A, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8120­6353
HP 12500 AC Power Entry Module - Switzerland - English localization
JF426A#ACD
Power Cord: Quantity :6, IEC 309, C19 STRAIGHT, 250 V, 16 A, 2.5 meters, 8.21 feet, Store Part# :8121-1287
HP 12500 AC Power Entry Module - Denmark - English localization
JF426A#ACE
Power Cord: Quantity :6, IEC 309, C19 STRAIGHT, 250 V, 16 A, 2.5 meters, 8.21 feet, Store Part# :8121-1287
HP 12500 AC Power Entry Module - Japan - English localization
JF426A#ACF
Power Cord: Quantity :6, NEMA 5-20P, C19 STRAIGHT, 125 V, 15 A, 2.5 meters, 8.21 feet, Store Part# :8120­6361
HP 12500 AC Power Entry Module - India - English localization
JF426A#ACJ
Power Cord: Quantity :6, SABS 164, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8121-0915
HP 12500 AC Power Entry Module - South Africa - English localization
JF426A#ACQ
Power Cord: Quantity :6, SABS 164, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8121-0915
HP 12500 AC Power Entry Module - Israel - English localization
JF426A#AKJ
Power Cord: Quantity :6, SI 32 90-DEG, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8121­1010
HP 12500 AC Power Entry Module - Thailand - English localization
JF426A#AKL
Power Cord: Quantity :6, NEMA 5-15P, C19 STRAIGHT, 250 V, 10 A, 2.5 meters, 8.21 feet, Store Part# :8121­0922
HP 12500 AC Power Entry Module - China - English localization
JF426A#AKM
Power Cord: Quantity :6, GB 1002, C19 STRAIGHT, 250 V, 16 A, 2.5 meters, 8.21 feet, Store Part# :8121-0924
HP 12500 AC Power Entry Module - Taiwan - English localization
JF426A#ARB
Power Cord: Quantity :6, CNS 690 Type 2(3), C19 STRAIGHT, 125 V, 15 A, 2.5 meters, 8.21 feet, Store Part# :8121-1286
HP 12500 AC Power Entry Module - Argentina - English localization
JF426A#ARM
Power Cord: Quantity :6, IRAM 2073, C19 STRAIGHT, 250 V, 16 A, 2.5 meters, 8.21 feet, Store Part# :8121­0925
HP 12500 AC Power Entry Module - L6-20 220V-NA
JF426A#B2E
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 16
Page 17
Power Cord: Quantity :6, NEMA 6-20P / L6-20P, C19 STRAIGHT, 250 V, 20 A, 2.5 meters, 8.21 feet, Store Part# :8120-6360
Part Store URL:
http://h20141.www2.hp.com/Hpparts/CountryChoice.aspx?mscssid=&valid=False
Configuration Rules:
Note 1
Supported on Switches JC654A, JF431C and JF430C only.
Note 2
Supported on Switches JC655A, JC652A and JC653A only.
Remarks:
12504 and 12508 only - Default 6 power supplies and allow the user to change down to 3.
12518 only - Default 12 power supplies and allow the user to change down to 6.
The power module support load balancing and N+1/N+M redundancy. Deploying N+1 power redundancy The total number of power modules (JF431C, JF430C) = Ceiling (total power load of the chassis/2000) + 1 For example, if the total load of the chassis is 3000 W, the number of power modules must be 2 + 1 = 3. Deploying 1:1 power redundancy JF431C-Requires 6 power modules. JF430C-Total number of power modules = [Ceiling (total power load of the chassis/2000) ] x 2 For example, if the total power load of the chassis is 7000 W, the total number of power modules must be (4 + 1) x 2 = 10.
Power Electrical Module
12504 and 12508 Only - System (std 0 // max 1) User Selection (min 1 // max 1)
12518 - System (std 0 // max 2) User Selection (min 2 // max 2)
HP 12500 AC Power Entry Module
JF426A
See Configuration
Note:1, 2, 3,4
PDU Cable NA/MEX/TW/JP
JF426A#B2B
C19 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JF426A #B2C
C19 to C20 Jumper Cord
High Volt Power Entry Module to Wall Power Cord
JF426A #B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
Configuration Rules:
Note 1
Supported on Switch JC654x, JF431x and JF430x only.
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 17
Page 18
Note 2
Localization required on orders without #B2B, #B2C or #B2E options.
Note 3
When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be the Defaulted Power Cable option on the Power Electrical Module. (See Drop down remark in the "Internal Power Supplies" section.)
Note 4
#B2E is Offered only in NA, Mexico, Taiwan and Japan.
Remarks:
Drop down under power supply should offer the following options and results: Power Electrical Module to PDU Power Cord - #B2B in North America, Mexico, Taiwan, and Japan or #B2C ROW. (Watson Default B2B or B2C for Rack Level CTO) Power Electrical Module to Wall Power Cord - Localized Option (Watson Default for BTO and Box Level CTO) High Volt Power Electrical Module to Wall Power Cord - #B2E Option. (Offered only in North America, Mexico, Taiwan, and Japan)
Enter the following menu selections as integrated to the CTO Model X above if order is factory built.
Modules
Fabric Modules
12504 - System (std 0 // max 4) User Selection (min 4 // max 4) per Switch
12508 and 12518 System (std 0 // max 9) User Selection (min 8 // max 9) per Switch
HP 12508 Fabric Module
JC067B
See Configuration
Note:1, 4
HP 12518 Fabric Module
JC066A
See Configuration
Note:2, 4
HP 1250x G2 Fabric Module
JC658A
See Configuration
Note:1, 3, 4
HP 12518 G2 Fabric Module
JC657A
See Configuration
Note:2, 4
HP FF 12508E Fabric Mod
JG798A
See Configuration
Note:4, 6
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 18
Page 19
HP FF 12518E Fabric Mod
JG800A
See Configuration
Note:4, 7
Configuration Rules:
Note 1
Supported on Switch JF431C and JC652A Switch Chassis only.
Note 2
Supported on Switch JF430C and JC653A Switch Chassis only.
Note 3
Supported on Switch JC654A and JC655A Switch Chassis only.
Note 4
Fabric Modules cannot be mixed, They must all be the same SKU.
Note 6
Supported on Switch JG782A and JG783A Switch Chassis only.
Note 7
Supported on Switch JG784A and JG785A Switch Chassis only.
Remarks:
12504 Only - Default 4 of the JC658A Fabric Modules.
12508 and 12518 Only - Default 9 of the JC658A or JC657A Fabric Modules and allow the user to change to 8 if desired.
12508E and 12518E Only - Default 9 of the JG798A or JG800A Fabric Modules and allow the user to change to 8 if desired.
Management Modules
System (std 0 // max 2) User Selection (min 1 // max 2) per Switch
HP 12500 Main Processing Unit
JC072B
No supported Transceivers
See Configuration
Note:1, 3
HP 12500 TAA Main Processing Unit
JC808A
No supported Transceivers
See Configuration
Note:1, 2, 3
HP 12500 Type A MPU w/Comware v7 OS
JG497A
No supported Transceivers
See Configuration
Note:1, 3
HP FF 12500E MPU
JG802A
No supported Transceivers
See Configuration
Note:1, 4
Configuration Rules:
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 19
Page 20
Note 1
Management Modules cannot be mixed, They must all be the same SKU.
Note 2
TAA Modules are available in the US, India, South Korea, Vietnam and Taiwan only.
Note 3
Supported on JF431C, JC652A, JF430C, JC653A, JC654A and JC655A Switch Chassis only.
Note 4
Supported on JG782A, JG783A, JG784A and JG785A Switch Chassis only.
Remarks:
Default 2 of the J072B's but allow to go down 1.
I/O Modules
12504 - System (std 0 // max 4) User Selection (min 0 // max 4)
12508 - System (std 0 // max 8) User Selection (min 0 // max 8)
12518 - System (std 0 // max 18) User Selection (min 0 // max 18)
HP 12500 48-port GbE SFP LEB Module
JC075B
Min 0 // Max 48 SFP Transceivers
See Configuration
Note:3, 10
HP 12500 48-port GbE SFP LEC Module
JC069B
Min 0 // Max 48 SFP Transceivers
See Configuration
Note:3, 10
HP 12500 8-port 10GbE XFP LEB Module
JC073B
Min 0 // Max 8 XFP Transceivers
See Configuration
Note:1, 5, 10
HP 12500 32-port 10GbE SFP+ REB Module
JC064B
Min 0 // Max 32 SFP+ Transceivers
See Configuration
Note:1, 4, 10
HP 12500 8-port 10GbE XFP LEC Module
JC068B
Min 0 // Max 8 XFP Transceivers
See Configuration
Note:1, 5, 10
HP 12500 32-port 10GbE SFP+ REC Module
JC476B
Min 0 // Max 32 SFP+ Transceivers
See Configuration
Note:1, 4, 10
HP 12500 48-port Gig-T LEB Module
JC074B
No supported Transceivers
See Configuration
Note:10
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 20
Page 21
HP 12500 48-port Gig-T LEC Module
JC065B
No supported Transceivers
See Configuration
Note:10
HP 12500 20Gbps VPN Firewall Module
JG371A
min=0 \ max=2 SFP Transceivers
See Configuration
Note:7,9,10
HP 12500 VPN Firewall Module
JC635A
min=0 \ max=2 SFP Transceivers
See Configuration
Note:7, 10
HP 12500 8-port 10GbE SFP+ LEF Module
JC659A
Min 0 // Max 8 SFP+ Transceivers
See Configuration
Note:4, 10
HP 12500 48-port GbE SFP LEF Module
JC660A
Min 0 // Max 48 SFP Transceivers
See Configuration
Note:3, 10
HP 12500 8-port 10GbE SFP+ LEB Module
JC780A
Min 0 // Max 8 SFP+ Transceivers
See Configuration
Note:4, 10
HP 12500 8-port 10GbE SFP+ LEC Module
JC781A
Min 0 // Max 8 SFP+ Transceivers
See Configuration
Note:4, 10
HP 12500 16-port 10GbE SFP+ LEB Module
JC782A
Min 0 // Max 16 SFP+ Transceivers
See Configuration
Note:4, 6, 10
HP 12500 16-port 10GbE SFP+ LEC Module
JC783A
Min 0 // Max 16 SFP+ Transceivers
See Configuration
Note:4, 6, 10
HP 12500 48-port Gig-T LEC TAA Module
JC809A
No supported Transceivers
See Configuration
Note:8, 10
HP 12500 8-port 10GbE XFP LEC TAA Mod
JC810A
Min 0 // Max 8 XFP Transceivers
See Configuration
Note:5, 8, 10
HP 12500 48-port GbE SFP LEC TAA Module
JC811A
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 21
Page 22
Min 0 // Max 48 SFP Transceivers
See Configuration
Note:3, 8, 10
HP 12500 32p 10GbE SFP+ REC TAA Module
JC812A
Min 0 // Max 32 SFP+ Transceivers
See Configuration
Note:4, 8, 1
HP 12500 8-port 10GbE SFP+ LEC TAA Mod
JC813A
Min 0 // Max 8 SFP+ Transceivers
See Configuration
Note:4, 8, 10
HP 12500 16p 10GbE SFP+ LEC TAA Module
JC814A
Min 0 // Max 16 SFP+ Transceivers
See Configuration
Note:4, 6, 8, 10
HP 12500 8-port 10GbE SFP+ LEF TAA Mod
JC817A
Min 0 // Max 8 SFP+ Transceivers
See Configuration
Note:4, 8, 10
HP 12500 48-port GbE SFP LEF TAA Module
JC818A
Min 0 // Max 48 SFP Transceivers
See Configuration
Note:3, 8, 10
HP FF 12500 16p 40GbE QSFP+ FD Mod
JG790A
Min 0 // Max 16 QSFP+ Transceivers
See Configuration
Note:2, 10
HP FF 12500 48p 1/10GbE SFP+ FD Mod
JG796A
Min 0 // Max 48 SFP+ Transceivers
See Configuration
Note:3, 4, 10
HP FF 12500 40p 1/10GbE SFP+ FD Mod
JG792A
Min 0 // Max 40 SFP+ Transceivers
See Configuration
Note:3, 4, 10
HP FF 12500 40p 1/10GbE SFP+ FG Mod
JG794A
Min 0 // Max 40 SFP+ Transceivers
See Configuration
Note:3, 4, 10
Configuration Rules:
Note 1
If this Modules is selected with the JF430C - HP A12518 Switch Chassis and ANY of the below Fabric Modules, Then its Max = 14:
HP 12518 Fabric Module
JC066A
HP 12518 TAA-compliant Fabric Module
JC819A
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 22
Page 23
Note 2
The following 40G Transceivers install into this Module: HP X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver
JG661A
HP X140 40G QSFP+ MPO SR4 Transceiver
JG325B
HP X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver
JG709A
Note 3
The following Transceivers install into this Module: HP X170 1G SFP LC LH70 1550 Transceiver
JD109A
HP X170 1G SFP LC LH70 1570 Transceiver
JD110A
HP X170 1G SFP LC LH70 1590 Transceiver
JD111A
HP X170 1G SFP LC LH70 1610 Transceiver
JD112A
HP X170 1G SFP LC LH70 1470 Transceiver
JD113A
HP X170 1G SFP LC LH70 1490 Transceiver
JD114A
HP X170 1G SFP LC LH70 1510 Transceiver
JD115A
HP X170 1G SFP LC LH70 1530 Transceiver
JD116A
HP X120 1G SFP LC LH100 Transceiver
JD103A
HP X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HP X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HP X120 1G SFP RJ45 T Transceiver
JD089B
HP X120 1G SFP LC SX Transceiver
JD118B
HP X120 1G SFP LC LX Transceiver
JD119B
HP X125 1G SFP LC LH70 Transceiver
JD063A
HP X120 1G SFP LC BX 10-U Transceiver
JD098B
HP X120 1G SFP LC BX 10-D Transceiver
JD099B
HP X114 100M SFP LC FX Transceiver
JF833A
HP X120 100M/1G SFP LC LX Transceiver
JF832A
Note 4
The following Transceivers install into this Module: HP X130 10G SFP+ LC SR Transceiver
JD092A
HP X130 10G SFP+ LC LRM Transceiver
JD093A
HP X130 10G SFP+ LC LR Transceiver
JD094A
HP X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
JD097B
HP X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
JD097C
HP X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
JG081C
HP X130 10G SFP+ LC ER 40km Transceiver
JG234A
HP X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable
JC784C
Note 5
The following Transceivers install into this Module: HP X135 10G XFP LC ER Transceiver
JD121A
HP X130 10G XFP LC LR Single Mode 10km 1310nm Transceiver
JD108B
HP X130 10G XFP LC SR Transceiver
JD117B
HP X130 10G XFP LC ZR Single Mode 80km 1550nm Transceiver
JD107A
HP X180 10G XFP LC LH 80km 1538.98nm DWDM Transceiver
JG226A
HP X180 10G XFP LC LH 80km 1539.77nm DWDM Transceiver
JG227A
HP X180 10G XFP LC LH 80km 1540.56nm DWDM Transceiver
JG228A
HP X180 10G XFP LC LH 80km 1542.14nm DWDM Transceiver
JG229A
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 23
Page 24
HP X180 10G XFP LC LH 80km 1542.94nm DWDM Transceiver
JG230A
HP X180 10G XFP LC LH 80km 1558.98nm DWDM Transceiver
JG231A
HP X180 10G XFP LC LH 80km 1559.79nm DWDM Transceiver
JG232A
HP X180 10G XFP LC LH 80km 1560.61nm DWDM Transceiver
JG233A
Note 6
If this Module is selected then ONLY the following Fabric Modules must be selected as well: HP 12518 G2 Fabric Module
JC657A
HP 1250x G2 Fabric Module
JC658A
HP 1250x TAA-compliant G2 Fabric Module
JC815A
HP 12518 TAA-compliant G2 Fabric Module
JC816A
HP FF 12508E Fabric Mod
JG798A
HP FF 12518E Fabric Mod
JG800A
Note 7
The following Transceivers install into this Module: (Use #0D1 if switch is CTO) - if applicable HP X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HP X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HP X125 1G SFP LC LH70 Transceiver
JD063B
HP X120 1G SFP LC SX Transceiver
JD118B
HP X120 1G SFP LC LX Transceiver
JD119B
Note 8
TAA Modules are available in the US, India, South Korea, Vietnam and Taiwan only.
Note 9
"These modules are Not Supported with Management Module JG497A - HP 12500 Type A MPU w/Comware v7 OS. They are Only Supported with Management Modules JC072B - HP 12500 Main Processing Unit, JC808A - HP 12500 TAA Main Processing Unit and JG802A HP FF 12500E MPU ."
Note 10
Supported on JF431C, JC652A, JF430C, JC653A, JC654A, JC655A, JG782A, JG783A, JG784A and JG785A Switch Chassis only.
Remarks
JC073B, JC064B, JC068B, and JC476B - Do not install the card in any of the following slots: slot 16, 17, 18, or 19 of the S12518.
Transceivers
SFP Transceivers
HP X170 1G SFP LC LH70 1550 Transceiver
JD109A
HP X170 1G SFP LC LH70 1570 Transceiver
JD110A
HP X170 1G SFP LC LH70 1590 Transceiver
JD111A
HP X170 1G SFP LC LH70 1610 Transceiver
JD112A
HP X170 1G SFP LC LH70 1470 Transceiver
JD113A
HP X170 1G SFP LC LH70 1490 Transceiver
JD114A
HP X170 1G SFP LC LH70 1510 Transceiver
JD115A
HP X170 1G SFP LC LH70 1530 Transceiver
JD116A
HP X120 1G SFP LC LH100 Transceiver
JD103A
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 24
Page 25
HP X125 1G SFP LC LH40 1310nm XCVR
JD061A
HP X120 1G SFP LC LH40 1550nm XCVR
JD062A
HP X125 1G SFP LC LH70 Transceiver
JD063B
HP X120 1G SFP RJ45 T Transceiver
JD089B
HP X120 1G SFP LC SX Transceiver
JD118B
HP X120 1G SFP LC LX Transceiver
JD119B
HP X120 1G SFP LC BX 10-U Transceiver
JD098B
HP X120 1G SFP LC BX 10-D Transceiver
JD099B
HP X110 100M SFP LC FX Transceiver
JF833A
HP X120 100M/1G SFP LC LX Transceiver
JF832A
SFP+ Transceivers
HP X130 10G SFP+ LC SR Transceiver
JD092B
HP X130 10G SFP+ LC LRM Transceiver
JD093B
HP X130 10G SFP+ LC LR Transceiver
JD094B
HP X130 10G SFP+ LC ER 40km Transceiver
JG234A
HP X240 10G SFP+ SFP+ 3m DAC Cable
JD097C#B01
HP X240 10G SFP+ SFP+ 5m DAC Cable
JG081C#B01
HP X240 10G SFP+ 7m DAC Cable
JC784C#B01
QSFP+ Transceivers
HP X140 40G QSFP+ LC LR4 SM XCVR
JG661A
HP X140 40G QSFP+ MPO SR4 XCVR
JG325B
HP X140 40G QSFP+ CSR4 300m XCVR
JG709A
XFP Transceivers
HP X135 10G XFP LC ER Transceiver
JD121A
HP X130 10G XFP LC ZR 1550nm Transceiver
JD107A
HP X130 10G XFP LC SR Transceiver
JD117B
HP X130 10G XFP LC LR 1310nm Transceiver
JD108B
HP X135 10G XFP LC ER Transceiver
JG226A
HP X130 10G XFP SC ZR Transceiver
JG227A
HP X130 10G XFP LC SR Transceiver
JG228A
HP X130 10G XFP SC LR Transceiver
JG229A
HP X135 10G XFP LC ER Transceiver
JG230A
HP X130 10G XFP SC ZR Transceiver
JG231A
HP X130 10G XFP LC SR Transceiver
JG232A
HP X130 10G XFP SC LR Transceiver
JG233A
Server Specific Options
HP Premier Flex LC/LC OM4 2f 1m Cbl
QK732A
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 25
Page 26
HP Premier Flex LC/LC OM4 2f 2m Cbl
QK733A
HP Premier Flex LC/LC OM4 2f 5m Cbl
QK734A
HP Premier Flex LC/LC OM4 2f 15m Cbl
QK735A
HP Premier Flex LC/LC OM4 2f 30m Cbl
QK736A
HP Premier Flex LC/LC OM4 2f 50m Cbl
QK737A
Cable Guides
System (std 0 // max 1) User Selection (min 0 // max 1) Per Switch
HP 12500 Side Cable Management Guide
JC084A
HP 12508 Cable Guides for AC Pwr Switch
JC785A
See Configuration
Note:1
HP 12518 Cable Guides for AC Pwr Switch
JC786A
See Configuration
Note:2
HP 12508 Cable Guides for DC Pwr Switch
JC787A
See Configuration
Note:3
HP 12518 Cable Guides for DC Pwr Switch
JC788A
See Configuration
Note:4
HP 12508E Optional Cbl Guide for AC Swch
JG830A
See Configuration
Note:5
HP 12518E Optional Cbl Guide for AC Swch
JG831A
See Configuration
Note:6
HP 12508E Optional Cbl Guide for DC Swch
JG832A
See Configuration
Note:7
HP 12518E Optional Cbl Guide for DC Swch
JG833A
See Configuration
Note:8
Configuration Rules:
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 26
Page 27
Note 1
Supported on Switch JF431x - HP 12508 AC Switch Chassis only.
Note 2
Supported on Switch JF430x - HP 12518 AC Switch Chassis only.
Note 3
Supported on Switch JC652x -HP 12508 DC Switch Chassis only.
Note 4
Supported on Switch JC653x - HP 12518 DC Switch Chassis only.
Note 5
Supported on Switch JG782A - HP FF 12508E AC Switch Chassis only.
Note 6
Supported on Switch JG784A - HP FF 12518E AC Switch Chassis only.
Note 7
Supported on Switch JG783A - HP FF 12508E DC Switch Chassis only.
Note 8
Supported on Switch JG785A - HP FF 12518E DC Switch Chassis only.
Remarks:
These items are optional .and used by customers for I/O cabling management.
Fan Assemblies
12504 Only - System (std 0 // max 1) User Selection (min 1 // max 1) Per Switch
12508 and 12518 Only - System (std 0 // max 2) User Selection (min 2 // max 2) Per Switch
HP 12504 Fan Assembly
JC664A
See Configuration
Note:3
HP 12518 Fan Assembly
JC080A
See Configuration
Note:2
HP 12508 Fan Assembly
JC081A
See Configuration
Note:1
HP FF 12500E Fan Tray Assembly
JG805A
See Configuration
Note:4
Configuration Rules:
Note 1
Supported on Switch JF431C and JC652A Switch Chassis only.
Note 2
Supported on Switch JF430C and JC653A Switch Chassis only.
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 27
Page 28
Note 3
Supported on Switch JC654A and JC655A Switch Chassis only.
Note 4
Supported on JG782A, JG783A, JG784A and JG785A Switch Chassis only
Air Filter Assemblies
System (std 0 // max 1) User Selection (min 0 // max 1)
HP 12508 Optional Air Filter
JC082A
See Configuration
Note:1
HP 12518 Optional Air Filter
JC083A
See Configuration
Note:2
HP FF 12508E Optional Air Filter
JG808A
See Configuration
Note:3
HP FF 12518E Optional Air Filter
JG809A
See Configuration
Note:4
Configuration Rules:
Note 1
Supported on Switch JF431C and JC652A Switch Chassis only.
Note 2
Supported on Switch JF430C and JC653A Switch Chassis only.
Note 3
Supported on Switch JF431C, JC652A, JG782A and JG783A Switch Chassis only.
Note 4
Supported on Switch JF430C, JC653A, JG784A and JG785A Switch Chassis only.
Power Monitor Module
12508E and 12518E only-System (std 0 // max 1) User Selection (min 0 // max 1) Per Switch
12504 and 12508 only-System (std 0 // max 1) User Selection (min 0 // max 1) Per Switch
12518 only-System (std 0 // max 2) User Selection (min 0 // max 2) Per Switch
HP 12500 Spare Power Monitor Module
JC502A
See Configuration
Note:1
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 28
Page 29
HP FF 12500E Spare Pwr Monitor Mod
JG804A
See Configuration
Note:2
Configuration Rules:
Note 1
This item is only used to replace the Power Monitor Module of an JF431C, JF430C, JC652C and JC653A . A host is delivered with the Power Monitor Module.
Note 2
This item is only used to replace the Power Monitor Module of an JG782A, JG784A, JG783A and JG785A . A host is delivered with the Power Monitor Module.
Power Cables
12500 only-System (std 0 // max 6 or 12) User Selection (min 0 // max 6 or 12)
12500E only-System (std 0 // max 8 or 16) User Selection (min 0 // max 8 or 16)
HP X210 10m JG-to-bare 72v DC Pwr Cable
JG280A
See Configuration
Note:1
Configuration Rules:
Note 1
If the DC Power Supplies are selected, Then the number of DC power cables should match the number of DC power supplies.
Compact Flash cards
HP X600 1G Compact Flash Card
JC684A
Parts List Only
HP FF 4GB Compact Flash Card
JG806A
Parts List Only
See Configuration
Note:1
Configuration Rules:
Note 1
Supported on MPU Module JG802A only.
SDRAM
HP X610 1GB DDR2 SDRAM Memory
JC071A
Parts List Only
HP FF 4GB DDR3 SDRAM
JG807A
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 29
Page 30
Parts List Only
See Configuration
Note:1
Configuration Rules:
Note 1
Supported on MPU Module JG802A only.
Mounting Kit
HP X421 Chassis Universal 4-post Rack Mounting Kit
JC665A
Configuration Rules:
Remarks:
This item is optional and used by customers to allow the chassis to slide in and out of the rack
QuickSpecs
HP 12500 Switch Series
Configuration
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 30
Page 31
HP 12504 AC Switch Chassis (JC654A)
I/O ports and slots
4 open module slots
Supports a maximum of 192 Gigabit Ethernet ports or 192 1/10GbE ports or 64 40GbE ports, or a combination
Additional ports and slots
2 MPU (for management modules) slots 4 switch fabric slots
Physical characteristics
Dimensions
17.4(w) x 27.87(d) x 17.4(h) in (44.2 x 70.8 x 44.2 cm) (10U height)
Weight
132.28 lb (60 kg)
Full configuration weight
220.46 lb (100 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash, 256 MB compact flash, 4 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
1920 Mpps
Routing/Switching capacity
3240 Gb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Frequency
50/60 Hz
Maximum heat dissipation
8123 BTU/hr (8569.77 kJ/hr)
AC voltage
100-120/200-240 VAC
Maximum power rating
2380 W
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 31
Page 32
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
3-year, 4-hour onsite, 24x7 coverage for hardware (U7M17E) 3-year, 4-hour onsite, 24x7 coverage for hardware (U7M19E) 3-year, 24x7 SW phone support, software updates (U7M25E) 4-year, 4-hour onsite, 13x5 coverage for hardware (U7M30E) 4-year, 4-hour onsite, 24x7 coverage for hardware (U7M32E) 4-year, 4-hour onsite, 24x7 coverage for hardware (U7M45E) 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (U7M39E) 4-year, 24x7 SW phone support, software updates (U7M38E) 5-year, 4-hour onsite, 13x5 coverage for hardware (U7M43E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (U7M52E) 5-year, 24x7 SW phone support, software updates (U7M51E) 3 Yr 6 hr Call-to-Repair Onsite (U7M22E) 3 Yr 6 hr Call-to-Repair Onsite (U7M22E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UW992E) 4 Yr 6 hr Call-to-Repair Onsite (U7M35E 5 Yr 6 hr Call-to-Repair Onsite (U7M48E) 3-year, 4-hour onsite, 13x5 coverage for HW, 13x5 SW phone support and SW updates (U7M26E) 1-year, 4-hour onsite, 13x5 coverage for hardware (U7M05E) 1-year, 4-hour onsite, 24x7 coverage for hardware (U7M07E) 1-year, 6 hour Call-To-Repair Onsite for hardware (U7M09E) 1-year, 24x7 software phone support, software updates (U7M11E) 1-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support and software updates (U7M12E) 1-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M03E) 1 year, 24x7 software phone support, software updates + 4 hour hardware exchange (U7M04E) 3-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M13E) 3-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M14E) 3-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (U7M15E) 4-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 32
Page 33
(U7M27E) 4-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (U7M28E) 5-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M40E) 5-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (U7M41E) 3 Yr NBD Onsite Proactive Care (U7M16E) 4 Yr NBD Onsite Proactive Care (U7M29E) 5 Yr NBD Onsite Proactive Care (U7M42E) 3 Yr 4hr/24x7 Proactive Care (U7M20E) 4 Yr 4hr/24x7 Proactive Care (U7M33E) 5 Yr 4hr/24x7 Proactive Care (U7M46E) 3 Yr 6hr CTR Proactive Care (U7M23E) 4 Yr 6hr CTR Proactive Care (U7M36E) 5 Yr 6hrCTR Proactive Care (U7M49E)
Refer to the HP website at
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
HP 12504 DC Switch Chassis (JC655A)
I/O ports and slots
4 open module slots Supports a maximum of 192 Gigabit Ethernet ports or 192 1/10GbE ports or 64 40GbE ports, or a combination
Additional ports and slots
2 MPU (for management modules) slots 4 switch fabric slots
Physical characteristics
Dimensions
17.4(w) x 27.87(d) x 17.4(h) in (44.2 x 70.8 x 44.2 cm) (10U height)
Weight
132.28 lb (60 kg)
Full configuration weight
220.46 lb (100 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash, 256 MB compact flash, 4 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
1920 Mpps
Routing/Switching capacity
3240 Gb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 33
Page 34
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Maximum heat dissipation
8123 BTU/hr (8569.77 kJ/hr)
DC Voltage
-48 to -60 VDC
Maximum power rating
2380 W
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
3-year, 4-hour onsite, 24x7 coverage for hardware (U7M17E) 3-year, 4-hour onsite, 24x7 coverage for hardware (U7M19E) 3-year, 24x7 SW phone support, software updates (U7M25E) 4-year, 4-hour onsite, 13x5 coverage for hardware (U7M30E) 4-year, 4-hour onsite, 24x7 coverage for hardware (U7M32E) 4-year, 4-hour onsite, 24x7 coverage for hardware (U7M45E) 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (U7M39E) 4-year, 24x7 SW phone support, software updates (U7M38E) 5-year, 4-hour onsite, 13x5 coverage for hardware (U7M43E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (U7M52E) 5-year, 24x7 SW phone support, software updates (U7M51E) 3 Yr 6 hr Call-to-Repair Onsite (U7M22E) 3 Yr 6 hr Call-to-Repair Onsite (U7M22E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UW992E)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 34
Page 35
4 Yr 6 hr Call-to-Repair Onsite (U7M35E 5 Yr 6 hr Call-to-Repair Onsite (U7M48E) 3-year, 4-hour onsite, 13x5 coverage for HW, 13x5 SW phone support and SW updates (U7M26E) 1-year, 4-hour onsite, 13x5 coverage for hardware (U7M05E) 1-year, 4-hour onsite, 24x7 coverage for hardware (U7M07E) 1-year, 6 hour Call-To-Repair Onsite for hardware (U7M09E) 1-year, 24x7 software phone support, software updates (U7M11E) 1-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support and software updates (U7M12E) 1-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M03E) 1 year, 24x7 software phone support, software updates + 4 hour hardware exchange (U7M04E) 3-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M13E) 3-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M14E) 3-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (U7M15E) 4-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M27E) 4-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (U7M28E) 5-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (U7M40E) 5-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (U7M41E) 3 Yr NBD Onsite Proactive Care (U7M16E) 4 Yr NBD Onsite Proactive Care (U7M29E) 5 Yr NBD Onsite Proactive Care (U7M42E) 3 Yr 4hr/24x7 Proactive Care (U7M20E) 4 Yr 4hr/24x7 Proactive Care (U7M33E) 5 Yr 4hr/24x7 Proactive Care (U7M46E) 3 Yr 6hr CTR Proactive Care (U7M23E) 4 Yr 6hr CTR Proactive Care (U7M36E) 5 Yr 6hrCTR Proactive Care (U7M49E)
Refer to the HP website at
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
HP 12508 AC Switch Chassis (JF431C)
I/O ports and slots
8 open module slots Supports a maximum of 384 Gigabit Ethernet ports or 384 1/10GbE ports or 128 40GbE ports, or a combination
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
Physical characteristics
Dimensions
17.4(d) x 29.13(w) x 38.39(h) in. (44.2 x 73.99 x 97.51 cm) (22U height)
Weight
209.44 lb (95 kg)
Full configuration weight
374.78 lb. (170 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB RAM (Ingress, shared by 24 1-GbE ports)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 35
Page 36
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash MB, 256 MB compact flash, 4 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
3840 Mpps
Routing/Switching capacity
6120 Gb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Frequency
50/60 Hz
Achieved Miercom Certified Green Award
*
* Products within this series have achieved sufficient scores in each of the rated criteria to achieve the Miercom Certified Green distinction Award. See the Specifications section of this series for more information.
Description
10GbE modules consume half the power compared to competitive products; redundant, scalable, 90% efficient power supplies deliver high reliability in the data center; new ASIC technology has low power consumption when providing rich features.
Maximum heat dissipation
14587 BTU/hr (15389.29 kJ/hr)
AC voltage
100-120/200-240 VAC
Maximum power rating
4750 W
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 36
Page 37
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (UW984E) 3-year, 4-hour onsite, 24x7 coverage for hardware (UW987E) 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UW990E) 3-year, 24x7 SW phone support, software updates (UW993E) Installation with minimum configuration, system-based pricing (UX034E) 4-year, 4-hour onsite, 13x5 coverage for hardware (UW985E) 4-year, 4-hour onsite, 24x7 coverage for hardware (UW988E) 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UW991E) 4-year, 24x7 SW phone support, software updates (UW994E) 5-year, 4-hour onsite, 13x5 coverage for hardware (UW986E) 5-year, 4-hour onsite, 24x7 coverage for hardware (UW989E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UW992E) 5-year, 24x7 SW phone support, software updates (UW995E) 3 Yr 6 hr Call-to-Repair Onsite (UW996E) 4 Yr 6 hr Call-to-Repair Onsite (UW997E) 5 Yr 6 hr Call-to-Repair Onsite (UW998E) 1-year, 4-hour onsite, 13x5 coverage for hardware (HR494E) 1-year, 4-hour onsite, 24x7 coverage for hardware (HR495E) 1-year, 6 hour Call-To-Repair Onsite for hardware (HR498E) 1-year, 24x7 software phone support, software updates (HR497E) 1-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support and software updates (HR496E)
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
HP 12508 DC Switch Chassis (JC652A)
I/O ports and slots
8 open module slots Supports a maximum of 384 Gigabit Ethernet ports or 384 1/10GbE ports or 128 40GbE ports, or a combination
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 37
Page 38
Physical characteristics
Dimensions
17.4(d) x 29.13(w) x 38.39(h) in. (44.2 x 73.99 x 97.51 cm) (22U height)
Weight
209.44 lb (95 kg)
Full configuration weight
374.78 lb. (170 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB RAM (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash MB, 256 MB compact flash, 4 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
3840 Mpps
Routing/Switching capacity
6120 Gb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Maximum heat dissipation
14587 BTU/hr (15389.29 kJ/hr)
DC voltage
-48 to -60 VDC
Maximum power rating
4750 W
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 38
Page 39
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (UW984E) 3-year, 4-hour onsite, 24x7 coverage for hardware (UW987E) 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UW990E) 3-year, 24x7 SW phone support, software updates (UW993E) Installation with minimum configuration, system-based pricing (UX034E) 4-year, 4-hour onsite, 13x5 coverage for hardware (UW985E) 4-year, 4-hour onsite, 24x7 coverage for hardware (UW988E) 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UW991E) 4-year, 24x7 SW phone support, software updates (UW994E) 5-year, 4-hour onsite, 13x5 coverage for hardware (UW986E) 5-year, 4-hour onsite, 24x7 coverage for hardware (UW989E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UW992E) 5-year, 24x7 SW phone support, software updates (UW995E) 3 Yr 6 hr Call-to-Repair Onsite (UW996E) 4 Yr 6 hr Call-to-Repair Onsite (UW997E) 5 Yr 6 hr Call-to-Repair Onsite (UW998E) 1-year, 4-hour onsite, 13x5 coverage for hardware (HR494E) 1-year, 4-hour onsite, 24x7 coverage for hardware (HR495E) 1-year, 6 hour Call-To-Repair Onsite for hardware (HR498E) 1-year, 24x7 software phone support, software updates (HR497E) 1-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support and software updates (HR496E)
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
HP 12518 AC Switch Chassis (JF430C)
I/O ports and slots
18 open module slots Supports a maximum of 864 Gigabit Ethernet ports or 864 1/10GbE ports or 288 40GbE ports, or a combination
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
Physical characteristics
Dimensions
17.4(d) x 29.13(w) x 66.38(h) in. (44.2 x 73.99 x 168.61 cm) (38U height)
Weight
352.74 lb (160 kg)
Full configuration weight
639.33 lb (290 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB RAM (Ingress, shared by 24 1-GbE ports)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 39
Page 40
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash MB, 256 MB compact flash, 4 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
8640 Mpps
Routing/Switching capacity
13.3 Tb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Frequency
50/60 Hz
Maximum heat dissipation
32859 BTU/hr (34666.24 kJ/hr)
AC voltage
100-120/200-240 VAC
Maximum power rating
10700 W
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 40
Page 41
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (UX046E) 3-year, 4-hour onsite, 24x7 coverage for hardware (UX049E) 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UX052E) 3-year, 24x7 SW phone support, software updates (UX055E) Installation with minimum configuration, system-based pricing (UX034E) 4-year, 4-hour onsite, 13x5 coverage for hardware (UX047E) 4-year, 4-hour onsite, 24x7 coverage for hardware (UX050E) 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UX053E) 4-year, 24x7 SW phone support, software updates (UX056E) 5-year, 4-hour onsite, 13x5 coverage for hardware (UX048E) 5-year, 4-hour onsite, 24x7 coverage for hardware (UX051E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UX054E) 5-year, 24x7 SW phone support, software updates (UX057E) 3 Yr 6 hr Call-to-Repair Onsite (UX058E) 4 Yr 6 hr Call-to-Repair Onsite (UX059E) 5 Yr 6 hr Call-to-Repair Onsite (UX060E) 1-year, 4-hour onsite, 13x5 coverage for hardware (HR489E) 1-year, 4-hour onsite, 24x7 coverage for hardware (HR490E) 1-year, 6 hour Call-To-Repair Onsite for hardware (HR493E) 1-year, 24x7 software phone support, software updates (HR492E) 1-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support and software updates (HR491E)
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
HP 12518 DC Switch Chassis (JC653A)
I/O ports and slots
18 open module slots Supports a maximum of 864 Gigabit Ethernet ports or 864 1/10GbE ports or 288 40GbE ports, or a combination
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
Physical characteristics
Dimensions
17.4(d) x 29.13(w) x 66.38(h) in. (44.2 x 73.99 x 168.61 cm) (38U height)
Weight
352.74 lb (160 kg)
Full configuration weight
639.33 lb (290 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB RAM (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash MB, 256 MB compact flash, 4 GB RAM
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 41
Page 42
Fabric
PowerPC @ 400 MHz, 128 MB RAM MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
8640 Mpps
Routing/Switching capacity
13.3 Tb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Maximum heat dissipation
32859 BTU/hr (34666.24 kJ/hr)
Maximum power rating
10700 W
DC Voltage
-48 to -60 VDC
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (UX046E)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 42
Page 43
3-year, 4-hour onsite, 24x7 coverage for hardware (UX049E) 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UX052E) 3-year, 24x7 SW phone support, software updates (UX055E) Installation with minimum configuration, system-based pricing (UX034E) 4-year, 4-hour onsite, 13x5 coverage for hardware (UX047E) 4-year, 4-hour onsite, 24x7 coverage for hardware (UX050E) 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UX053E) 4-year, 24x7 SW phone support, software updates (UX056E) 5-year, 4-hour onsite, 13x5 coverage for hardware (UX048E) 5-year, 4-hour onsite, 24x7 coverage for hardware (UX051E) 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UX054E) 5-year, 24x7 SW phone support, software updates (UX057E) 3 Yr 6 hr Call-to-Repair Onsite (UX058E) 4 Yr 6 hr Call-to-Repair Onsite (UX059E) 5 Yr 6 hr Call-to-Repair Onsite (UX060E) 1-year, 4-hour onsite, 13x5 coverage for hardware (HR489E) 1-year, 4-hour onsite, 24x7 coverage for hardware (HR490E) 1-year, 6 hour Call-To-Repair Onsite for hardware (HR493E) 1-year, 24x7 software phone support, software updates (HR492E) 1-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support and software updates (HR491E)
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
HP FlexFabric 12508E AC Switch Chassis (JG782A)
I/O ports and slots
8 open module slots Supports a maximum of 384 Gigabit Ethernet ports or 384 1/10GbE ports or 128 40GbE ports
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
Physical characteristics
Dimensions
17.4(w) x 29.13(d) x 38.39(h) in (44.2 x 74.0 x 97.51 cm) (22U height)
Weight
242.51 lb (110 kg)
Full configuration weight
374.78 lb (170 kg)
Memory and processor
Gigabit Module
PowerPC @ 667, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by 24 1-GbE ports)
Management Module
Quad Core CPU @ 1800 MHz, 512 MB flash, 4 GB compact flash, 8 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
4800 Mpps
Routing/Switching capacity
10.8 Tb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 43
Page 44
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Frequency
50/60 Hz
Achieved Miercom Certified Green Award
Description
10GbE modules consume half the power compared to competitive products; redundant, scalable, 90% efficient power supplies deliver high reliability in the data center; new ASIC technology has low power consumption when providing rich features.
Maximum heat dissipation
14587 BTU/hr (15389.29 kJ/hr)
AC voltage
100 - 120 / 200 - 240 VAC
Maximum power rating
4750 W
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 44
Page 45
Services
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
HP FlexFabric 12508E DC Switch Chassis (JG783A)
I/O ports and slots
8 open module slots Supports a maximum of 384 Gigabit Ethernet ports or 384 1/10GbE ports or 128 40GbE ports
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
Physical characteristics
Dimensions
17.4(w) x 29.13(d) x 38.39(h) in (44.2 x 73.99 x 97.51 cm) (22U height)
Weight
209.44 lb (95 kg)
Full configuration weight
374.78 lb (170 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Quad Core CPU @ 1800 MHz, 512 MB flash, 4 GB compact flash, 8 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
4800 Mpps
Routing/Switching capacity
10.8 Tb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Maximum heat dissipation
14587 BTU/hr (15389.29 kJ/hr)
Maximum power rating
4750 W
DC Voltage
-48 to -60 VDC
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 45
Page 46
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
HP FlexFabric 12518E AC Switch Chassis (JG784A)
I/O ports and slots
18 open module slots Supports a maximum of 864 Gigabit Ethernet ports or 864 1/10GbE ports or 288 40GbE ports, or a combination
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
Physical characteristics
Dimensions
17.4(w) x 29.13(d) x 66.38(h) in (44.2 x 73.99 x 168.61 cm) (38U height)
Weight
352.74 lb (160 kg)
Full configuration weight
639.33 lb (290 kg)
Memory and processor
Gigabit Module
PowerPC @ 667, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Quad Core CPU @ 1800 MHz, 512 MB flash, 4 GB compact flash, 8 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
10.8 Bpps
Routing/Switching capacity
24.3 Tb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 46
Page 47
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Frequency
50/60 Hz
Maximum heat dissipation
32859 BTU/hr (34666.24 kJ/hr)
AC voltage
100 - 120 / 200 - 240 VAC
Maximum power rating
10700 W
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
HP FlexFabric 12518E DC Switch Chassis (JG785A)
I/O ports and slots
18 open module slots Supports a maximum of 864 Gigabit Ethernet ports or 864 1/10GbE ports or 288 40GbE ports, or a combination
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 47
Page 48
Additional ports and slots
2 MPU (for management modules) slots 9 switch fabric slots
Physical characteristics
Dimensions
17.4(w) x 29.13(d) x 66.38(h) in (44.2 x 73.99 x 168.61 cm) (38U height)
Weight
352.74 lb (160 kg)
Full configuration weight
639.33 lb (290 kg)
Memory and processor
Gigabit Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by 24 1-GbE ports)
10G Module
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by 2 10GbE ports)
Management Module
Quad Core CPU @ 1800 MHz, 512 MB flash, 4 GB compact flash, 8 GB RAM
Fabric
PowerPC @ 400 MHz, 128 MB RAM
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Performance
Throughput
10.8 Bpps
Routing/Switching capacity
24.3 Tb/s
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative humidity
5% to 95%, non-condensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, non-condensing
Electrical characteristics
Maximum heat dissipation
32859 BTU/hr (34666.24 kJ/hr)
Maximum power rating
10700 W
DC Voltage
-48 to -60 VDC
Notes
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950­1:2001; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC61000-4-2
Radiated
EN 61000-4-3; IEC61000-4-3
EFT/Burst
EN 61000-4-4; IEC61000-4-4
Surge
EN 61000-4-5; IEC61000-4-5
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 48
Page 49
Conducted
EN 61000-4-6; IEC61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C); SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem interface
Services
Refer to the HP website at:
www.hp.com/networking/services
for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office
Standards and protocols
(applies to all products in series)
BGP
RFC 1657 Definitions of Managed Objects for BGPv4 RFC 1771 BGPv4 RFC 1772 Application of the BGP RFC 1773 Experience with the BGP-4 Protocol RFC 1774 BGP-4 Protocol Analysis RFC 1997 BGP Communities Attribute RFC 1998 PPP Gandalf FZA Compression Protocol RFC 2385 BGP Session Protection via TCP MD5 RFC 2439 BGP Route Flap Damping RFC 2796 BGP Route Reflection RFC 2842 Capability Advertisement with BGP-4 RFC 2858 BGP-4 Multi-Protocol Extensions RFC 2918 Route Refresh Capability
Denial of service protection
RFC 2267 Network Ingress Filtering Automatic Filtering of well known Denial of Service Packets CPU DoS Protection Rate Limiting by ACLs
Device management
RFC 1155 Structure and Mgmt Information (SMIv1) RFC 1157 SNMPv1/v2c RFC 1305 NTPv3 RFC 1945 Hypertext Transfer Protocol -- HTTP/1.0 RFC 2452 MIB for TCP6 RFC 2454 MIB for UDP6 RFC 2573 (SNMPv3 Applications) RFC 2578-2580 SMIv2 RFC 2579 (SMIv2 Text Conventions) RFC 2580 (SMIv2 Conformance) RFC 2819 (RMON groups Alarm, Event, History and
RFC 2466 ICMPv6 MIB RFC 2571 SNMP Framework MIB RFC 2572 SNMP-MPD MIB RFC 2573 SNMP-Target MIB RFC 2613 SMON MIB RFC 2618 RADIUS Client MIB RFC 2620 RADIUS Accounting MIB RFC 2665 Ethernet-Like-MIB RFC 2674 802.1p and IEEE 802.1Q Bridge MIB RFC 2737 Entity MIB (Version 2) RFC 2787 VRRP MIB RFC 2819 RMON MIB RFC 2863 The Interfaces Group MIB RFC 2925 Ping MIB RFC 2932IP (Multicast Routing MIB) RFC 2933 IGMP MIB RFC 3273 HC-RMON MIB RFC 3414 SNMP-User based-SM MIB RFC 3415 SNMP-View based-ACM MIB RFC 3418 MIB for SNMPv3 RFC 3621 Power Ethernet MIB RFC 3813 MPLS LSR MIB RFC 3814 MPLS FTN MIB RFC 3815 MPLS LDP MIB RFC 3826 AES for SNMP's USM MIB RFC 4133 Entity MIB (Version 3) LLDP-EXT-DOT1-MIB LLDP-EXT-DOT3-MIB LLDP-MIB
MPLS
RFC 2205 Resource ReSerVation Protocol (RSVP) ­Version 1 Functional Specification RFC 2209 Resource ReSerVation Protocol (RSVP)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 49
Page 50
Statistics only) RFC 2819 RMON RFC 3417 (SNMP Transport Mappings) SNMP v3 and RMON RFC support SSHv1/SSHv2 Secure Shell TACACS/TACACS+
General protocols
IEEE 802.1ad Q-in-Q IEEE 802.1ag Service Layer OAM IEEE 802.1ah Provider Backbone Bridges IEEE 802.1D MAC Bridges IEEE 802.1p Priority IEEE 802.1Q VLANs IEEE 802.1s Multiple Spanning Trees IEEE 802.1v VLAN classification by Protocol and Port IEEE 802.1w Rapid Reconfiguration of Spanning Tree IEEE 802.1X PAE IEEE 802.3ab 1000BASE-T IEEE 802.3ad Link Aggregation (LAG) IEEE 802.3ae 10-Gigabit Ethernet IEEE 802.3ah Ethernet in First Mile over Point to Point Fiber - EFMF IEEE 802.3i 10BASE-T IEEE 802.3u 100BASE-X IEEE 802.3x Flow Control IEEE 802.3z 1000BASE-X RFC 768 UDP RFC 783 TFTP Protocol (revision 2) RFC 791 IP RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 854 TELNET RFC 868 Time Protocol RFC 903 RARP RFC 951 BOOTP RFC 959 File Transfer Protocol (FTP) RFC 1027 Proxy ARP RFC 1042 IP Datagrams RFC 1350 TFTP Protocol (revision 2) RFC 1519 CIDR RFC 1542 BOOTP Extensions RFC 1812 IPv4 Routing RFC 2131 DHCP RFC 2338 VRRP RFC 2784 Generic Routing Encapsulation (GRE) RFC 2865 Remote Authentication Dial In User Service (RADIUS)
IP multicast
RFC 2702 Requirements for Traffic Engineering Over MPLS RFC 2858 Multiprotocol Extensions for BGP-4 RFC 3031 Multiprotocol Label Switching Architecture RFC 3032 MPLS Label Stack Encoding RFC 3036 LDP Specification RFC 3107 Carrying Label Information in BGP-4 RFC 3209 RSVP-TE: Extensions to RSVP for LSP Tunnels RFC 3479 Fault Tolerance for the Label Distribution Protocol (LDP) RFC 3487 Graceful Restart Mechanism for LDP RFC 4090 Fast Reroute Extensions to RSVP-TE for LSP Tunnels RFC 4364 BGP/MPLS IP Virtual Private Networks (VPNs) RFC 4379 Detecting Multi-Protocol Label Switched (MPLS) Data Plane Failures RFC 4447 Pseudowire Setup and Maintenance Using LDP RFC 4448 Encapsulation Methods for Transport of Ethernet over MPLS Networks RFC 4664 Framework for Layer 2 Virtual Private Networks RFC 4665 Service Requirements for Layer 2 Provider Provisioned Virtual Private Networks RFC 4761 Virtual Private LAN Service (VPLS) Using BGP for Auto-Discovery and Signaling RFC 4762 Virtual Private LAN Service (VPLS) Using Label Distribution Protocol (LDP) Signaling
Network management
IEEE 802.1AB Link Layer Discovery Protocol (LLDP) IEEE 802.1D (STP) RFC 1155 Structure of Management Information RFC 1157 SNMPv1 RFC 1215 SNMP Generic traps RFC 1757 RMON 4 groups: Stats, History, Alarms and Events RFC 1905 SNMPv2 Protocol Operations RFC 2211 Controlled-Load Network RFC 2272 SNMPv3 Management Protocol RFC 2273 SNMPv3 Applications RFC 2274 USM for SNMPv3 RFC 2571 SNMP Management Frameworks RFC 2572 SNMPv3 Message Processing RFC 2573 SNMPv3 Applications RFC 2576 Coexistence between SNMP versions RFC 2578 SMIv2 RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 50
Page 51
RFC 1112 IGMP RFC 2236 IGMPv2 RFC 2283 Multiprotocol Extensions for BGP-4 RFC 2362 PIM Sparse Mode RFC 2934 Protocol Independent Multicast MIB for IPv4 RFC 3376 IGMPv3 RFC 3618 Multicast Source Discovery Protocol (MSDP) RFC 4601 PIM Sparse Mode
IPv6
RFC 1350 TFTP RFC 1981 IPv6 Path MTU Discovery RFC 2080 RIPng for IPv6 RFC 2460 IPv6 Specification RFC 2461 IPv6 Neighbor Discovery RFC 2462 IPv6 Stateless Address Auto-configuration RFC 2463 ICMPv6 RFC 2473 Generic Packet Tunneling in IPv6 RFC 2475 IPv6 DiffServ Architecture RFC 2529 Transmission of IPv6 Packets over IPv4 RFC 2710 Multicast Listener Discovery (MLD) for IPv6 RFC 2740 OSPFv3 for IPv6 RFC 2893 Transition Mechanisms for IPv6 Hosts and Routers RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only) RFC 3315 DHCPv6 (client only) RFC 3484 Default Address Selection for IPv6 RFC 3513 IPv6 Addressing Architecture RFC 3587 IPv6 Global Unicast Address Format RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6 RFC 4251 SSHv6 Architecture RFC 4252 SSHv6 Authentication RFC 4253 SSHv6 Transport Layer RFC 4254 SSHv6 Connection RFC 4541 IGMP & MLD Snooping Switch RFC 4862 IPv6 Stateless Address Auto-configuration
MIBS
IEEE8023-LAG-MIB RFC 1213 MIB II RFC 1229 Interface MIB Extensions RFC 1286 Bridge MIB RFC 1493 Bridge MIB RFC 1573 SNMP MIB II RFC 1643 Ethernet MIB RFC 1657 BGP-4 MIB
RFC 3164 BSD syslog Protocol RFC 3415 SNMPv3 View-based Access Control Model VACM) ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED) SNMPv1/v2c/v3
OSPF
RFC 1245 OSPF protocol analysis RFC 1246 Experience with OSPF RFC 1587 OSPF NSSA RFC 1765 OSPF Database Overflow RFC 1850 OSPFv2 Management Information Base (MIB), traps RFC 2328 OSPFv2 RFC 2370 OSPF Opaque LSA Option RFC 3101 OSPF NSSA RFC 3623 Graceful OSPF Restart
QoS/CoS
IEEE 802.1P (CoS) RFC 2212 Guaranteed Quality of Service RFC 2474 DS Field in the IPv4 and IPv6 Headers RFC 2475 DiffServ Architecture RFC 2597 DiffServ Assured Forwarding (AF) RFC 2598 DiffServ Expedited Forwarding (EF) RFC 2697 A Single Rate Three Color Marker RFC 2698 A Two Rate Three Color Marker Bi-directional Rate Shaping
Security
IEEE 802.1X Port Based Network Access Control RFC 1321 The MD5 Message-Digest Algorithm RFC 2082 RIP-2 MD5 Authentication RFC 2104 Keyed-Hashing for Message Authentication RFC 2716 PPP EAP TLS Authentication Protocol RFC 2865 RADIUS Authentication RFC 2866 RADIUS Accounting RFC 2867 RADIUS Accounting Modifications for Tunnel Protocol Support RFC 2868 RADIUS Attributes for Tunnel Protocol Support RFC 2869 RADIUS Extensions RFC 3567 Intermediate System (IS) to IS Cryptographic Authentication Access Control Lists (ACLs) Guest VLAN for 802.1x MAC Authentication SSHv2 Secure Shell
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 51
Page 52
RFC 1724 RIPv2 MIB RFC 1757 Remote Network Monitoring MIB RFC 1850 OSPFv2 MIB RFC 2011 SNMPv2 MIB for IP RFC 2012 SNMPv2 MIB for TCP RFC 2013 SNMPv2 MIB for UDP RFC 2021 RMONv2 MIB RFC 2096 IP Forwarding Table MIB RFC 2233 Interfaces MIB RFC 2273 SNMP-NOTIFICATION-MIB RFC 2452 IPV6-TCP-MIB RFC 2454 IPV6-UDP-MIB RFC 2465 IPv6 MIB
Web Authentication
IKEv1
RFC 2865 - Remote Authentication Dial In User Service (RADIUS)
QuickSpecs
HP 12500 Switch Series
Technical Specifications
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 52
Page 53
HP 12500 Switch Series accessories
Modules NEW
HP FlexFabric 12500E Main Processing Unit
JG802A
HP 12500 Type A Main Processing Unit with Comware v7 Operating System
JG497A
HP 12500 Main Processing Unit
JC072B
NEW
HP FlexFabric 12500 4-port 100GbE CFP FD Module
JG786A
NEW
HP FlexFabric 12500 4-port 100GbE CFP FG Module
JG788A
QuickSpecs
HP 12500 Switch Series
Accessories
DA - 13785 Worldwide — Version 24 — May 12, 2014
Page 53
Loading...