Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Pressure Booster Pumps
FW0154
0907
Supersedes
0306
Description
Pressure booster pumps increase water pressure from city mains or private water systems. Applications include providing high water pressure for washing buildings, dairy
walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn
sprinkling and insecticide spraying. Stainless steel models can handle salt-water and
contaminated water in reverse osmosis filter and other aggressive water applications.
Unpacking
When unpacking the unit, inspect carefully for any damage that may have
occurred during transit.
NOTE: Use pump with clear water
only.
Single-phase models are equipped with a capacitor start, thermal protected motor.
Three-phase models require separate overload protection.
H
Inlet I
Discharge J
G
D
Figure 1
A
C
F
B
E
IL0391
60 Hz Motor Driven Pump Dimensions (See Figure 1) • Chart A
(*) NOTE: Figure 1, holes in mounting base are open slotted 3/8” wide x 1/2” long; dimension A & B are centerline from these
open slotted holes. These holes are suitable for 1/4 to 3/8” bolts.
Dimensions also apply to three phase models.
(†) Equipped with carrying handle. 132079 handle available as an option on other models. Add 1-3/8” to “G” if handle is included.
† Example: If PB0508A031 pump is connected to supply line of sufficient capacity, carrying water at 40 PSI, and the output of the pump is held to 7.3 GPM by a
gate valve, the pump will add 40 PSI to line pressure for a total output pressure of 80 PSI.
* Operation of pump in this range may result in reduced pump life and/or motor damage.
To keep pump and seal lubricated, a minimum flow of 1.5 GPM must always be maintained through the pump.
Motor voltage: Single Phase 1/3 - 2 HP - 115/230; 3 HP - 230V 60 Hz.
Three Phase 1/2 - 2 HP - 208-230/460, 50/60Hz.
Three Phase 3 HP - 208-230/460, 60 HZ
For three phase models, use suffix “3” on the model no. Example: PB0512A053
Seal compositionCarbon-silicon carbide, stainless steel spring
and Buna-N
*Models with powder coated inlet & discharge also available.
Carbon-silicon carbide, stainless steel spring
and Viton
Minimum Wire Size Chart (Gauge) Chart F
Motor
HP
1/3115/230114/1414/1414/1412/1412/1415/15
1/2115/230112/1412/1412/1412/1410/1420/15
3/4115/230112/1412/1410/1410/12 8/1220/15
1115/230110/1410/1410/12 8/12 6/1030/15
1
/2115/230110/12 8/12 6/12 */10 */1030/20
1
2115/230110/12 8/12 6/12 */10 */1030/20
32301 10 10 10 10 830
3/4230/460314/1414/1414/1414/1414/1415/15
1230/460314/1414/1414/1414/1412/1415/15
11/2230/460314/1414/1414/1412/1412/1415/15
2230/460314/1414/1414/1412/1410/1215/15
3230/460314/1414/1414/1412/1410/1215/15
(*) Not economical to run in 115V, use 230V.
VoltsPhase
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
0-5050-100100-150150-200200-300
Distance In Feet From Motor To Service Panel
Breaker Size
(Amps)
Wire Size
3
General Safety Information
Carefully read and follow all safety instructions in
this manual and on pump. Keep safety labels in good
condition. Replace missing or damaged safety labels.
9. Do not insert finger or any object into pump or motor
openings.
10. Secure the discharge line before starting the pump. An
unsecured discharge line will whip, possibly causing personal injury and/or property damage or puncture.
symbol on the pump or in the manual, look for one of the
following signal words and be alert to the potential for personal injury or property damage.
personal injury, death or major property damage if ignored.
personal injury or death, if ignored.
personal injury, product or property damage if ignored.
This is a SAFETY ALERT SYMBOL. When you see this
Warns of hazards that WILL cause serious
!
Warns of hazards that CAN cause serious
Warns of hazards that MAY cause minor
IMPORTANT: Indicates factors concerned with operation,
installation, assembly or maintenance which could result in
damage to the machine or equipment if ignored.
NOTE: Indicates special instructions which are important but
are not related to hazards.
!
Hazardous voltage. Can shock,
burn or cause
death. Ground
pump before connecting to power
supply.
Follow wiring instructions in this manual when connect-
ing to power lines.
!
performing any work on or near the motor or its connected
load.
Do not use to pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres.
Hazardous pressure! Install pressure relief valve in
discharge pipe. Release all pressure on system before working on any component.
Wire motor for correct voltage. See
“Electrical” section and Motor Data Charts
C&D of this manual, and motor nameplate.
Ground motor before connecting to
power supply.
Meet United States National Electrical
Code and local codes for all wiring.
Do not handle a pump or pump motor
with wet hands or when standing on a wet
or damp surface or in water.
Always disconnect power source before
1. Make workshop child proof - use padlocks, master
switches; remove starter keys.
2. Wear safety glasses when working with pumps.
3. Wear a face shield and proper apparel when pumping
hazardous chemicals.
4. Keep work area clean, uncluttered and properly lighted;
replace all unused tools and equipment.
5. Provide guarding around moving parts.
6. Keep visitors at a safe distance from the work area.
7. Periodically inspect pump and system components.
8. Protect electrical cord. Replace or repair damaged or
worn cords immediately.
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
engine. They are designed to operate at high temperatures.
!
the State of California to cause cancer and birth defects or
other reproductive harm.
!
been investigated for use in swimming pool areas.
NOTE: Pumps with the “CSA-CUS” mark are tested to UL standard UL778 and certified to CSA standard C22.2 No. 108.
Do not touch an operating motor or
This product contains chemicals known to
Risk of Electric Shock. This pump has not
Pre-Installation
HANDLING
1. Use handle supplied to lift pump.
2. Avoid impact on pump or motor. In particular, avoid
impact on discharge end of pump or rear motor access
cover.
LOCATION
!
age and/or personal injury might result from an inoperative
or leaking pump due to power outages, discharge line blockage, or any other reason, a backup system(s) should be used.
1. Locate pump as close to the fluid source as possible, keeping the inlet pipe short as possible.
2. Place unit where the pump and piping are protected from
the weather and extremes of heat, humidity and below
freezing temperatures.
3. Mount unit in a dry location that is easily accessible for
inspection and maintenance. If a dry location is not available, mount it on a foundation well above the wet floor.
4. Allow ample clearance around unit for free air circulation.
SUCTION LIMITATIONS
1. Units are non self-priming.
2. Pressure booster pumps are not recommended for suction
lift applications.
PIPING
1. Use galvanized piping, rigid plastic or other suitable pipe
that will not collapse under suction or rupture due to pressure.
forced industrial type that is rated higher than the shutoff
pressure of the system. Ordinary garden hose will collapse
and starve the pump of water.
2. The diameter of the inlet and discharge pipe should be
no smaller than the corresponding ports of the pump (See
Figure 1). Smaller pipe will reduce the capacity of the
pump. Increase pipe size on long runs.
3. Avoid air pockets in inlet piping or air will accumulate at
high points, making priming difficult.
4. Use pipe compound on all joints and connections. Use
Teflon tape or plastic joint stik, on plastic pipe. Draw all
pipe up tightly.
IMPORTANT: The entire system must be air and water tight
for efficient/proper operation.
4
In any installation where property dam-
If hose is used, make sure it is the rein-
Installation
PUMP INSTALLATION
IMPORTANT: Pump is built to handle
clear water only; it is not designed to
handle water containing sand, silt or
other abrasives.
1.Refer to Figures 6, 7, and 8 for typical installations.
No Sags
Sags Allow Air Pockets
No Air Leaks In
Inlet Pipe
If Air Flows
Water
Won’t
Pipe Joint Compound
Will Damage Plastic
IL0419
piping when assembling and when
installed. Failure to do so may cause
piping to break, pump to fail, motor
bearing failures, etc.
Support pump and
2. If the pump is used as part of a permanent installation, bolt to a rigid
foundation.
!
nents that are rated for maximum pressure pump can produce when used in
boosting system or any other system.
Do not exceed the total maximum
pressure boost as listed per model in
Performance Charts B.
Use only compo-
PRESSURE BOOST SYSTEMS
1. On pressure boost systems, locate
the pump so that there will always
be a positive supply of water to the
pump (See Figures 6, 7 and 8).
2. For service convenience, install a
gate valve and union in the inlet
and discharge line.
valve or other restricting type of valve
that will seriously restrict the pumps
discharge capacity.
Do not use a globe
3. Install a check valve as shown in
Figure 6. Be sure check valve flow
arrows point in the direction of
water flow.
4. Whenever dirt, sand or debris is
present in the supply water, install a
strainer or filter on the inlet side of
the pump (See Figure 7).
NOTE: For heavy amounts of sediment, install a trap filter on the inlet
side of the pump (See Figure 5).
NOTE: Pressure gauges installed
before and after the filter will show
pressure differential indicating the
need for filter replacement or cleaning.
If Air Pockets Form,
Water Won’t Flow
Figure 2 - No Air Pockets in Inlet Pipe
Mount pump in correct position or pump failure will result.
Correct
IL0418
Use Teflon Tape
Figure 3 - Inlet Pipe Must Not Leak
Incorrect
Figure 4AFigure 4B
SAND AND SEDIMENT TRAP FILTER
Standard Pressure
Tank - 42 Gallon Or
Larger
Outlet
Inlet
Sand Settles To The Bottom
Figure 5
Clean Out
IL0421
IMPORTANT: Clean all filters and strainers on a regular schedule.
IL0420
IL0315
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
5