HP FW0154, 0907, 0306 User Manual

Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per­sonal injury and/or property damage! Retain instructions for future reference.
Pressure Booster Pumps
FW0154
0907
Supersedes
0306
Description
Pressure booster pumps increase water pressure from city mains or private water sys­tems. Applications include providing high water pressure for washing buildings, dairy walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn sprinkling and insecticide spraying. Stainless steel models can handle salt-water and contaminated water in reverse osmosis filter and other aggressive water applications.
Unpacking
When unpacking the unit, inspect care­fully for any damage that may have occurred during transit.
NOTE: Use pump with clear water only.
H
Inlet I
Discharge J
G
D
Figure 1
A
C
F
B
E
IL0391
60 Hz Motor Driven Pump Dimensions (See Figure 1) • Chart A
Stainless
Steel Fitted
PB0508S031 PB0512S051 PB0516S071 PB0712S071 PB1014S101 PB1016S151 PB1914S201 PB2711S201 PB3506S201 PB2714S301 PB3508S301
-
-
-
-
Powder-Coated
Cast Iron Fitted
PB0508C031 PB0512C051 PB0516C071 PB0712C071 PB1014C101 PB1016C151 PB1914C201 PB2711C201 PB3506C201 PB2714C301 PB3508C301
-
-
-
-
Cast Iron
Fitted
PB0508A031† PB0512A051†
PB0516A071 PB0712A071 PB1014A101 PB1016A151 PB1914A201 PB2711A201 PB3506A201 PB2714A301 PB3508A301 PB5504A201 PB5506A301 PB8504A201 PB8505A301
Dimensions In Inches Lbs. Ship
AB C DE F GH IJ
3-1/4
3-3/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
10-3/16 13-3/8 16-1/2 13-3/8 16-5/16 17-5/8 18-1/8 15-3/8 13-15/16 18-1/2 17-1/8 13-3/4 18-1/16 16-1/2 19-5/16
3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8
6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2
19-15/16 23-3/8 27 23-7/8 27-1/4 29-3/16 29-11/16 27-1/2 25-7/8 30-9/16 29-3/16 25-15/16 30-3/16 28-5/8 31-1/2
7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8
1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16
2-1/8 2-1/8 2-1/8 2-1/8
3/4 3/4 3/4 3/4 3/4 3/4 3/4
3/4 3/4 3/4 3/4 3/4 3/4 3/4
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
Wt.
35 38 43 42 48 51 51 52 51 54 53 57 57 58 58
50 Hz Motor Driven Pump Dimensions (See Figure 1) •58
PB0508Y031 PB0514Y051 PB0714Y071 PB1020Y101 PB1023Y101 PB2717Y201
­PB1021Y101 PB1920Y151
-
(*) NOTE: Figure 1, holes in mounting base are open slotted 3/8” wide x 1/2” long; dimension A & B are centerline from these open slotted holes. These holes are suitable for 1/4 to 3/8” bolts. Dimensions also apply to three phase models. (†) Equipped with carrying handle. 132079 handle available as an option on other models. Add 1-3/8” to “G” if handle is included.
-
-
-
-
PB1023Z101
-
-
-
-
PB1922Z201
PB0508X031 PB0514X051 PB0714X071 PB1020X101 PB1023X101
-
PB3508X151
-
-
-
3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4
3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4
10-3/16 14-7/16 14-15/16 21-11/16 24-3/8 21-5/16 16-13/16 22-1/2 24-1/16 26-1/8
3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8
6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2
20-3/16 25-7/16 25-15/16 33-5/16 36 33-7/16 29-11/16 34-3/16 34-3/8 37-3/16
7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8
1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16
3/4 3/4 3/4 3/4 3/4
3/4 3/4 3/4
3/4 3/4 3/4 3/4 3/4
1
1
1
1 3/4 3/4 3/4
34 41 47 53 55 56 52 54 56 59
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
1
132934
PRESSURE ADDED - PSI 10 20 40 60 80 100 120 140 160 180 200
Stainless
Steel Fitted
PB0512S051 PB0512C051 PB0512A051• 1/2 12 9.8 9.2 8.2 7.3 6.3 5.2 3.5 131 PB0516S071 PB0516C071 PB0516A071 3/4 16 9.9 9.5 8.7 8.0 7.3 6.5 5.8 4.8 3.5 175 PB0712S071 PB0712C071 PB0712A071• 3/4 12 14.0 13.4 12.2 10.9 9.5 7.9 6.0 3.6 152 PB1014S101 PB1014C101 PB1014A101 1 14 * * 14.5 13.4 12.3 11.2 9.8 8.3 6.3 3.3 185 PB1016S151 PB1016C151 PB1016A151 1-1/2 16 * * 14.7 13.8 12.9 11.9 10.8 9.7 8.2 6.6 4.3 211 PB1914S201 PB1914C201 PB1914A201 2 14 27.5 27.0 25.7 24.2 22.6 20.8 18.7 16.2 13.0 7.8 190 PB3506S201 PB3506C201 PB3506A201 2 6 41.5 41.1 40.5 34.2 23.3 90 PB2711S201 PB2711C201 PB2711A201 2 11 * * 31.3 29.3 26.8 23.8 19.8 13.0 150 PB3508S301 PB3508C301 PB3508A301 3 8 41.5 41.1 40.9 40.0 34.2 26.4 10.0 120 PB2714S301 PB2714C301 PB2714A301 3 14 * * 32.2 30.6 28.9 27.0 24.8 22.0 18.4 12.2 190
--
--
--
--
† Example: If PB0508A031 pump is connected to supply line of sufficient capacity, carrying water at 40 PSI, and the output of the pump is held to 7.3 GPM by a
gate valve, the pump will add 40 PSI to line pressure for a total output pressure of 80 PSI.
* Operation of pump in this range may result in reduced pump life and/or motor damage.
To keep pump and seal lubricated, a minimum flow of 1.5 GPM must always be maintained through the pump.
Motor voltage: Single Phase 1/3 - 2 HP - 115/230; 3 HP - 230V 60 Hz. Three Phase 1/2 - 2 HP - 208-230/460, 50/60Hz. Three Phase 3 HP - 208-230/460, 60 HZ For three phase models, use suffix “3” on the model no. Example: PB0512A053
• Handle included with these models only.
Powder-
Coated Cast
Iron Fitted
PB0508C031 PB0508A031• 1/3 8 9.5 8.7 7.3 5.8 3.5 87
Cast Iron
Fitted
PB5504A201 2 4 77.6 71.5 PB5506A301 3 6 77.8 74.4 PB8504A201 2 4 105.8 90.0 PB8505A301 3 5 108.8 98.8
HP Stage Output - Gallons per Minute
52.5
65.0
47.0
60.0
31.9
51.1
25.0 60
Max.
Press.
PSI
55 83 49
Suction
Pipe
Pipe Tap
Tap
NPT
3/4” 3/4”
1” 1”
2” 2”
Disch.
NPT
PERFORMANCE SPECIFICATIONS
Single Phase Motor Data 60HZ Chart C
Single Phase† 60 Hz 3450 RPM Capacitor Start
HP
1/3 1/2 3/4
1
1-1/2
2 3
Motor
Voltage
115/230 115/230 115/230 115/230 115/230 115/230
230
Factory
Connected
Motor
Voltage
115V 115V 115V 230V 230V 230V 230V
Service Factor Motor
Amps
Locked Rotor Motor
Amps
115V 230V 115V 230V
8.6
13.0
14.0
18.0
21.0
25.0
-
4.3
6.5
7.0
9.0
10.5
12.5
13.5
26.0
36.0
52.0
78.0
98.0
116.0
-
13.0
18.0
26.0
39.0
49.0
58.0
53.0
Code Letter
K K K
L
J H D
Single Phase Motor Data 50HZ
Single Phase† 50 Hz 2850 RPM Capacitor Start
1/2 3/4
1
1-1/2
2
115/230 115/230 115/230 115/230
230
115V 115V 230V 230V 230V
†Thermal overload protector - automatic reset
10.0
14.4
16.4
23.6
-
5.0
7.2
8.2
11.8
13.2
48.0
64.0
72.0
104.0
-
24.0
32.0
36.0
52.0
55.0
M
L K K H
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
2
Three Phase Motor Data Chart D
Three Phase† 60/50 Hz 3450/2850 RPM Capacitor Start
HP
3/4
1
1-1/2
2
3✝✝
Motor
Voltage
208-230/460 208-230/460 208-230/460 208-230/460 208-230/460
Factory
Connected
Motor
Voltage
230V 230V 230V 230V 230V
Service Factor Motor
Amps
Locked Rotor Motor
Amps
230V 460V 230V 460V
3.5
4.5
5.7
7.4
9.8
1.75
2.25
2.85
3.70
4.90
19.0
26.9
33.5
44.0
48.0
13.5
16.8
22.0
24.0
9.5
Code Letter
K K K K D
✝✝3 HP, 3 Phase motor operable on 60Hz only.
Material Construction Chart E
Component Standard Models* Stainless Steel Models
Motor Rear access - Nema 56J face Rear access - Nema 56J face
Bearings Ball-ball, permanently lubricated Ball-ball, permanently lubricated
Impellers Noryl with 304 stainless steel bearing insert Noryl with 304 stainless steel bearing insert
Diffuser Noryl Noryl
Diffuser plates Delrin Delrin
Pump shaft 416 Stainless steel 304 Stainless steel
Pump shaft coupling 316 Stainless steel 316 Stainless steel
Pump shell 304 Stainless steel 304 Stainless steel
Discharge & inlet casting Cast iron 304 Stainless steel
O-Rings Buna-N Viton
Seal composition Carbon-silicon carbide, stainless steel spring
and Buna-N
*Models with powder coated inlet & discharge also available.
Carbon-silicon carbide, stainless steel spring and Viton
Minimum Wire Size Chart (Gauge) Chart F
Motor
HP
1/3 115/230 1 14/14 14/14 14/14 12/14 12/14 15/15
1/2 115/230 1 12/14 12/14 12/14 12/14 10/14 20/15
3/4 115/230 1 12/14 12/14 10/14 10/12 8/12 20/15
1 115/230 1 10/14 10/14 10/12 8/12 6/10 30/15
1
/2 115/230 1 10/12 8/12 6/12 */10 */10 30/20
1
2 115/230 1 10/12 8/12 6/12 */10 */10 30/20
3 230 1 10 10 10 10 8 30
3/4 230/460 3 14/14 14/14 14/14 14/14 14/14 15/15
1 230/460 3 14/14 14/14 14/14 14/14 12/14 15/15
11/2 230/460 3 14/14 14/14 14/14 12/14 12/14 15/15
2 230/460 3 14/14 14/14 14/14 12/14 10/12 15/15
3 230/460 3 14/14 14/14 14/14 12/14 10/12 15/15
(*) Not economical to run in 115V, use 230V.
Volts Phase
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
0-50 50-100 100-150 150-200 200-300
Distance In Feet From Motor To Service Panel
Breaker Size
(Amps)
Wire Size
3
General Safety Information
Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good
condition. Replace missing or damaged safety labels.
9. Do not insert finger or any object into pump or motor openings.
10. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing per­sonal injury and/or property damage or puncture.
symbol on the pump or in the manual, look for one of the following signal words and be alert to the potential for per­sonal injury or property damage.
personal injury, death or major property damage if ignored.
personal injury or death, if ignored.
personal injury, product or property damage if ignored.
This is a SAFETY ALERT SYMBOL. When you see this
Warns of hazards that WILL cause serious
!
Warns of hazards that CAN cause serious
Warns of hazards that MAY cause minor
IMPORTANT: Indicates factors concerned with operation, installation, assembly or maintenance which could result in damage to the machine or equipment if ignored. NOTE: Indicates special instructions which are important but are not related to hazards.
!
Hazardous volt­age. Can shock, burn or cause death. Ground
pump before con­necting to power supply.
Follow wiring instructions in this manual when connect-
ing to power lines.
!
performing any work on or near the motor or its connected load.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flam­mable and/or explosive atmospheres.
Hazardous pressure! Install pressure relief valve in discharge pipe. Release all pressure on system before work­ing on any component.
Wire motor for correct voltage. See “Electrical” section and Motor Data Charts C&D of this manual, and motor nameplate.
Ground motor before connecting to power supply.
Meet United States National Electrical Code and local codes for all wiring.
Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface or in water.
Always disconnect power source before
1. Make workshop child proof - use padlocks, master switches; remove starter keys.
2. Wear safety glasses when working with pumps.
3. Wear a face shield and proper apparel when pumping hazardous chemicals.
4. Keep work area clean, uncluttered and properly lighted; replace all unused tools and equipment.
5. Provide guarding around moving parts.
6. Keep visitors at a safe distance from the work area.
7. Periodically inspect pump and system components.
8. Protect electrical cord. Replace or repair damaged or worn cords immediately.
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
engine. They are designed to operate at high temperatures.
!
the State of California to cause cancer and birth defects or other reproductive harm.
!
been investigated for use in swimming pool areas. NOTE: Pumps with the “CSA-CUS” mark are tested to UL stan­dard UL778 and certified to CSA standard C22.2 No. 108.
Do not touch an operating motor or
This product contains chemicals known to
Risk of Electric Shock. This pump has not
Pre-Installation
HANDLING
1. Use handle supplied to lift pump.
2. Avoid impact on pump or motor. In particular, avoid impact on discharge end of pump or rear motor access cover.
LOCATION
!
age and/or personal injury might result from an inoperative or leaking pump due to power outages, discharge line block­age, or any other reason, a backup system(s) should be used.
1. Locate pump as close to the fluid source as possible, keep­ing the inlet pipe short as possible.
2. Place unit where the pump and piping are protected from the weather and extremes of heat, humidity and below freezing temperatures.
3. Mount unit in a dry location that is easily accessible for inspection and maintenance. If a dry location is not avail­able, mount it on a foundation well above the wet floor.
4. Allow ample clearance around unit for free air circulation.
SUCTION LIMITATIONS
1. Units are non self-priming.
2. Pressure booster pumps are not recommended for suction lift applications.
PIPING
1. Use galvanized piping, rigid plastic or other suitable pipe that will not collapse under suction or rupture due to pres­sure.
forced industrial type that is rated higher than the shutoff pressure of the system. Ordinary garden hose will collapse and starve the pump of water.
2. The diameter of the inlet and discharge pipe should be no smaller than the corresponding ports of the pump (See Figure 1). Smaller pipe will reduce the capacity of the pump. Increase pipe size on long runs.
3. Avoid air pockets in inlet piping or air will accumulate at high points, making priming difficult.
4. Use pipe compound on all joints and connections. Use Teflon tape or plastic joint stik, on plastic pipe. Draw all pipe up tightly.
IMPORTANT: The entire system must be air and water tight for efficient/proper operation.
4
In any installation where property dam-
If hose is used, make sure it is the rein-
Installation
PUMP INSTALLATION IMPORTANT: Pump is built to handle
clear water only; it is not designed to handle water containing sand, silt or other abrasives.
1.Refer to Figures 6, 7, and 8 for typi­cal installations.
No Sags
Sags Allow Air Pockets
No Air Leaks In Inlet Pipe
If Air Flows Water Won’t
Pipe Joint Compound Will Damage Plastic
IL0419
piping when assembling and when installed. Failure to do so may cause piping to break, pump to fail, motor bearing failures, etc.
Support pump and
2. If the pump is used as part of a per­manent installation, bolt to a rigid foundation.
!
nents that are rated for maximum pres­sure pump can produce when used in boosting system or any other system. Do not exceed the total maximum pressure boost as listed per model in Performance Charts B.
Use only compo-
PRESSURE BOOST SYSTEMS
1. On pressure boost systems, locate the pump so that there will always be a positive supply of water to the pump (See Figures 6, 7 and 8).
2. For service convenience, install a gate valve and union in the inlet and discharge line.
valve or other restricting type of valve that will seriously restrict the pumps discharge capacity.
Do not use a globe
3. Install a check valve as shown in Figure 6. Be sure check valve flow arrows point in the direction of water flow.
4. Whenever dirt, sand or debris is present in the supply water, install a strainer or filter on the inlet side of the pump (See Figure 7).
NOTE: For heavy amounts of sedi­ment, install a trap filter on the inlet side of the pump (See Figure 5). NOTE: Pressure gauges installed before and after the filter will show pressure differential indicating the need for filter replacement or clean­ing.
If Air Pockets Form, Water Won’t Flow
Figure 2 - No Air Pockets in Inlet Pipe
Mount pump in correct position or pump failure will result.
Correct
IL0418
Use Teflon Tape
Figure 3 - Inlet Pipe Must Not Leak
Incorrect
Figure 4A Figure 4B
SAND AND SEDIMENT TRAP FILTER
Standard Pressure Tank - 42 Gallon Or Larger
Outlet
Inlet
Sand Settles To The Bottom
Figure 5
Clean Out
IL0421
IMPORTANT: Clean all filters and strainers on a regular schedule.
IL0420
IL0315
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com