Hozelock Cyprio Vorton 11, Vorton 18, Vorton 55, Vorton 36, 1554 Quick Start Manual

...
1554
Downloaded from www.watergardeningdirect.com
1558
1557
1559
Vorton 11/18/36/55
Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England
Tel: +44 (0) 121 313 1122
www.hozelock.com
33029-000
www.hozelock.com
?
2
YEAR
GUARANTEE
1 2
Downloaded from www.watergardeningdirect.com
3 4
65
7
8 9
10 11
Installation & Operating Instructions
Downloaded from www.watergardeningdirect.com
READ INSTRUC TIONS C AREFULLY BEFORE ATTEMPTING INSTALLATION. KEEP THESE
INSTRUCTIONS FOR FUTURE REFERENCE.
This Vorton Ultra Violet Clarifier is electrically operated and designed to work with an existing pond filtration system. Typically this should consist of a mechanical and biological filter, filter pump and conne cting hose. The unit is intended for household outdoor use.
Attention: UV Caution
WARNING: This appliance contains a UVC emitter.
Unintended use of the appliance or damage to the housing may result in the escape of dangerous UVC radiation. UVC radiation may, even in little doses, cause harm to the eyes and skin.
The Lamp is fitted with an interlock that will turn the
lamp off in the event that the housing is inadver tently opened. When switched on, the lamp can be checked for operation by looking for a bluish glow from the translucent hosetails. sight window. Do not run the Vorton UVC dry.
WARNING: Do not operate the UVC emitter when it is
removed from the appliance enclosure.
Important
This appliance must only be used by or under the supervision of a responsible adult who is capable of using the appliance in a safe way and who understands the hazards involved. Use and store this appliance out of reach of children and persons with reduced physical, sensory, or mental capabilities.
Warning:
Safety & Electrical Connections
WARNING: ALWAYS UNPLUG OR DISCONNEC T ALL
APPLIANCES IN THE POND FROM THE ELECTRICIT Y SUPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED, REPAIRED, MAINTAINED OR HANDLED.
The clear tube inside the unit is made from quart z glass
and care should be taken during installation and maintenance. We recommend the use of eye protection and suitable gloves.
The Vorton UVC is weatherproof but not submersible.
Position the unit horizontally near the pond but not where it can fall into the water or become waterlogged.
Important: This product is designed to be permanently
wired to the mains supply. For connection to the mains supply use only 3- core cable (ref HO5 RN -F). This has a minimum copper cross-section of 0.75mm2 with Polycloroprene-Rubber insulation. The termination to the mains supply should be:
a) Permanent.
b) Inside a dry weatherproof enclosure.
c) Through a double pole switched fused spur
to BS 3676.
d) Fitted with a 3 or 5 amp fuse.
Exposed cable runs should be sensibly positioned and
protected by armoured conduit, especially if there is a risk of contact with gardening equipment such as forks and lawnmowers, or children and domestic animals.
A 30mA maximum Residual Current Device (RCD) MUST
be fitted to the mains supply.
Permanent installations to the mains supply
(hard wiring), must conform to the National and Local wiring regulations. If in any doubt about wiring to the mains supply, consult a qualified electrician or local electricity authority.
Protect from frost. In cold winter weather
(when fish are inactive and algae growth ceases) the unit may be switched off. It should then be removed, drained of water
Installing this product in the garden is classed as
‘notifiable’ in the Regulations for England and Wales. The Regulations require you to tell your local authority building control department that you intend to install this product before installation. Your local authority will let you know how you can get your installation approved.
General Guidance
Performance - We recommend that for ma ximum performance this product should be used with a Hozelock Cyprio filter pump and filter. The unit should be run 24 hours a day throughout the feeding season. Failure to do this may result in green water and will invalidate the Clearwater Guarantee.
Flow Rate - For best results the entire contents of the pond should pass through the Vor ton UVC every 1½ - 2½ hours. We recommend that your pump is sized to supply the require d flow rate against the full hydraulic head (the vertical distance between the pond water sur face and filter inlet, plus an allowance of 0.6-0.9m, (2-3ft), for hose friction losses).
Pressure Rating - These Vorton UVC models have a maximum pressure rating of 0.7bar (or 7m, 0.07Mpa). The unit is therefore unsuitable for filtration systems that produce high levels of back pressure such as sand filters.
Po nd Trea tme nts - Some medications/ tre atments can degrade very quickly by UVC radiation. Switch off the unit during disease treatment.
Extra care should be taken with any hose connections as leaks will result in loss of water from the pond.
Spare Parts - Use only genuine Hozelock Cyprio replacement parts.
Installation
The Hozelock Cyprio Vorton UVC can be added to most
filter systems before or af ter filtration, the effect is the same. The water must be pumped through the unit - not gravity fed. A typical installation is shown in fig. 1.
Location - the unit MUST be installed horizontally and
on a solid surface. T he lid of a filter may be suitable if sturdy enough.
To mount the unit, using 3 suitable fixings, screw the
base to the mounting surface. (See fig. 2).
+ 5 hidden pages