1560
Saturn Booster
INSTALLATION AND OPERATING INSTRUCTIONS
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION.
INSTRUCTIONS D’INSTALLATION ET DE MISE EN ROUTE.
VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS AVANT L’INSTALLATION.
MONTAGE- UND BEDIENUNGSANLEITUNG.
VOR INGEBRAUCHNAHME BITTE SORGFÄLTIG LESEN.
ISTRUZIONI D’INSTALLAZIONE E D’USO.
LEGGERE ATTENTAMENTE LE ISTRUZIONI PRIMA DE PROCEDERE ALL’INSTALLAZIONE
DELLE LUCI.
INSTALLATIE EN GEBRUIKSAANWIJZING.
ALVORENS TE INSTALLEREN EERST AANDACHTIG DOORLEZEN.
INSTALLATION OCH BRUKSANVISNING.
LÄS INSTRUKTIONEN NOGGRANT FÖRE INSTALLATION.
INSTALLATIONS- OG BRUGSVEJLEDNING.
LÆS VEJLEDNINGEN OMHYGGELIGT IGENNEM FØR INSTALLATION.
INSTRUCCIONES DE INSTALACION Y FUNCIONAMIENTO.
LEANSE CUIDADOSAMENTE LAS INSTRUCCIONES ANTES DE COMENZAR LA INSTALACION.
ASENNUS JA KÄYTTÖOHJEET.
LUE OHJEET TARKOIN ENNEN ASENTAMISEEN RYHTYMISTÄ.
BRUKSANVISNING.
LES BRUKSANVISNINGEN NØYE FØR DU STARTER MONTERINGEN.
INSTRUCÕES DE INSTALAÇÃO E FUNCIONAMENTO.
LER AS INSTRUÇÕES CUIDADOSAMENTE ANTES DE INICIAR A INSTALAÇÃO.
INSTRUKJA INSTALACJI OBS¿UGI
PRZED ROZPOCZ≈CIEM INSTALACJI NALE…Y DOK¿ADNIE ZAPOZNA∏ SI≈ Z NINIEJSZ√
INSTRUKCJ√

The Hozelock Cyprio Saturn
Booster is an innovative self-
GB
leaning mechanical prefilter.
c
Designed to operate before any
pump-fed biological filter for fishponds
anging from 7,000 to 16,000 litres, the
r
Saturn Booster will remove up to 75% of
pond debris. This reduces filter maintenance
nd improves the biological performance of
a
your existing filter.
This appliance is not intended for use by
persons (including children) with reduced
hysical, sensory or mental capabilities,
p
or lack of experience and knowledge,
unless they have been given supervision
r instruction concerning use of the
o
appliance by a person responsible for
their safety. Children should be
upervised to ensure that they do not
s
play with the appliance. (Australia & NZ
only) This appliance is not intended for
se by young children or infirm persons
u
unless they have been adequately
supervised by a responsible person to
nsure that they can use the appliance
e
safely. Young children should be
supervised to ensure that they do not
lay with the appliance.
p
DESCRIPTION
Dirty water from the pond is pumped into
the Saturn Booster and spun around a
circular polyester mesh filter. Most particles
are trapped by the mesh and then removed
by a rotating jet. Dislodged particles fall into
a large waste collection area at the bottom,
while the cleaned water passes through to
your existing filter system.
As it is a sealed unit, waste removal from
the Saturn Booster is simply a matter of
lifting the flush-away handle for a few
seconds every week.
The Saturn Booster is designed for simple
retrofitting into an existing installation. The
hosetails supplied allow connection to
25mm, 32mm or 40mm hose.
To ensure reliable operation, there are two
valves built into the inlet assembly. These
are colour coded – blue and red.
The red valve is a filter bypass valve and
prevents damage to the Saturn Booster if
for whatever reason pressure rises above
safe levels. The valve protects the Saturn
Booster by redirecting the flow back to
pond via the lower hose connection on the
inlet assembly.
The blue valve is a self-regulating pressure
sensitive relief valve, which ensures
optimum operation by controlling the
pressure differential across the filter mesh
inside the Saturn Booster. Depending on the
flow rate and level of debris, the valve can
move down during normal operation,
indicating that it is regulating the pressure.
SAFETY AND ELECTRICAL
CONNECTIONS
• Always disconnect the electricity supply
before starting to handle, maintain,
repair or install any pond equipment.
• This product is not submersible, and
should be sited where it cannot fall into
the water or become waterlogged.
However, the design is weatherproof,
and the Saturn Booster can be safely
installed outdoors.
• This product is supplied with 10m of 3
core electric cable for connection to the
mains supply. The termination to the
mains supply should be permanent,
inside a dry, weatherproof enclosure,
hrough a double pole switched fused
t
spur with a minimum contact gap of
3mm – ‘(disconnector) to BS 3676’ – and
itted with a 3 amp fuse.
f
•
THIS APPLIANCE MUST BE EARTHED
AND IT IS ESSENTIAL THAT THE
CONNECTIONS ARE MADE USING THE
FOLLOWING CODE;
rown - Live
B
Blue - Neutral
reen/Yellow -
G
arth
E
The BROWN lead should be connected
o the LIVE terminal which may be
t
marked with an 'L' or coloured brown
or red. The BLUE lead should be
connected to the NEUTRAL terminal
which may be marked with an 'N' or
oloured blue or black. The
c
GREEN/YELLOW lead should be
connected to the EARTH terminal
which may be marked with an 'E' or
coloured green or green/yellow.
• Exposed cable runs should be sensibly
positioned and protected if necessary by
armoured conduit.
• A 10mA or 30mA Residual Current Circuit
Breaker (RCD) MUST be fitted to the
mains supply.
• Permanent installations to the mains
supply (hard wiring) must comply with
the regulations of your local authority.
Contact your local authority building
control department for advice before you
start installation and they will let you
know how to get your installation
approved.
• If in any doubt about wiring to the
mains supply, consult a qualified
electrician or your local authority.
• The pump is fitted with 10m of 3 core
electric cable which is permanently
connected and sealed to the motor.
The supply pump cable cannot be
replaced. If the cable is damaged, the
pump should be removed and discarded
and replaced with a new pump.
• Protect from frost if the unit is not run
year round, by draining and removing to
a store in a dry, frost protected place.
• When full of water, the Saturn Booster
weighs nearly 100kg. DO NOT attempt to
move when full of water. To drain, pull
up the flush handle to empty some of
the water, and then gently tilt the
Booster until most of the water is
emptied.
IMPORTANT NOTE: The Booster is a sealed
product and can be installed below pond
level. If you plan to bury it you will have to
remove the lid and siphon or ladle the
water out to empty it (for winter storage).
Never completely bury the Booster. Ensure
the lid and valve housing are above ground
as shown in Fig. 4.
1. INSTALLATION
Important:
The Saturn Booster can be fitted in a wide
variety of installations. However the
following conditions must be met:
• Water flow through the Saturn Booster
must be between 3500 litres per hour
and 8000 litres per hour.
• The Saturn Booster has to be connected
to an in-pond pump i.e. it is not suitable
for gravity-fed installations.
• Ensure the in-pond pump is raised
00mm (9”) above the bottom of the
2
pond. This will prevent any sediment on
the pond floor overwhelming your filter,
nd in the event of a leak outside the
a
pond, prevent your pond from being
completely emptied. If the pond has a lot
f debris on the bottom, it is always best
o
to remove it with a pond vacuum before
installing a new filter.
• The Saturn Booster must be installed
irectly after the in-pond pump and
d
before
both the Filter and Ultra Violet
Clarifier (UVC).
The pump supplying the Saturn Booster
•
must not have a maximum head
exceeding 6m (9 psi, 0.6 bar).
• The outlet and flush away hoses must not
rise more than 1m above their
onnection to the outlet assembly.
c
o complete the installation you will need
T
two additional hoses:
1. One of 25mm, 32mm or 40mm diameter
to take the waste from the Saturn
ooster to a convenient flower bed or
B
drain (the ‘Flush Away Hose’)
2. A hose with the same diameter as your
existing pond pump hose to connect
from the filter bypass valve on the
Saturn Booster back to your pond (the
‘Bypass’ hose).
Assembly
Unpack all contents from the box (Fig 1).
The Booster only requires the fitting of the
inlet assembly (see Fig 2)
• Gently push the inlet assembly into the
lid carefully aligning the two valves (Fig
2B)
• Tighten the two bolts using the Allen Key
supplied (Fig 2C)
Installation
The Saturn Booster should be sited out of
the pond in a position that is easily
accessible and where the waste hose can be
run to a convenient flowerbed or drain. The
Saturn Booster should be connected directly
to your in pond pump hose (i.e. before your
Filter [and UVC if fitted]) (Fig 3). The outlet
and waste hoses must not be raised more
than one metre above the Saturn Booster
(Fig 4); otherwise the filter bypass valve will
affect the performance of the Saturn
Booster.
The Saturn Booster should sit on a smooth
and level surface eg. a paving slab.
Inlet and Outlet Hoses:
• Cut your existing hose with a hacksaw at
the position where the Booster will be
installed, noting that the hose length
between the Booster and your filter
should be no more than 2m (Fig 5).
• If using 32mm or 40mm hose, cut two of
the hosetails supplied with a hacksaw to
suit (Fig 6) and attach to the top
connection on both the inlet assembly
and outlet assembly.
• Wrap the adhesive foam strips around
the hose and position the jubilee clips
over the foam strips to connect the hose
from the pond pump to the inlet
assembly hosetail (Fig 7A), and the hose
to your filter to the outlet assembly
hosetail (Fig 7B).
Flush-Away Hose:
The flush-away hose can have a diameter of
25mm, 32mm or 40mm and connects to the