Hozelock Cyprio Saturn Booster, 1560 Installation And Operating Instructions Manual

1560
Saturn Booster
INSTALLATION AND OPERATING INSTRUCTIONS
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION.
INSTRUCTIONS D’INSTALLATION ET DE MISE EN ROUTE.
VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS AVANT L’INSTALLATION.
MONTAGE- UND BEDIENUNGSANLEITUNG.
VOR INGEBRAUCHNAHME BITTE SORGFÄLTIG LESEN.
LEGGERE ATTENTAMENTE LE ISTRUZIONI PRIMA DE PROCEDERE ALL’INSTALLAZIONE
DELLE LUCI.
INSTALLATIE EN GEBRUIKSAANWIJZING.
ALVORENS TE INSTALLEREN EERST AANDACHTIG DOORLEZEN.
INSTALLATION OCH BRUKSANVISNING.
LÄS INSTRUKTIONEN NOGGRANT FÖRE INSTALLATION.
INSTALLATIONS- OG BRUGSVEJLEDNING.
LÆS VEJLEDNINGEN OMHYGGELIGT IGENNEM FØR INSTALLATION.
INSTRUCCIONES DE INSTALACION Y FUNCIONAMIENTO.
LEANSE CUIDADOSAMENTE LAS INSTRUCCIONES ANTES DE COMENZAR LA INSTALACION.
ASENNUS JA KÄYTTÖOHJEET.
LUE OHJEET TARKOIN ENNEN ASENTAMISEEN RYHTYMISTÄ.
BRUKSANVISNING.
LES BRUKSANVISNINGEN NØYE FØR DU STARTER MONTERINGEN.
INSTRUCÕES DE INSTALAÇÃO E FUNCIONAMENTO.
LER AS INSTRUÇÕES CUIDADOSAMENTE ANTES DE INICIAR A INSTALAÇÃO.
INSTRUKJA INSTALACJI OBS¿UGI
PRZED ROZPOCZ≈CIEM INSTALACJI NALE…Y DOK¿ADNIE ZAPOZNA∏ SI≈ Z NINIEJSZ√
INSTRUKCJ√
The Hozelock Cyprio Saturn Booster is an innovative self-
GB
leaning mechanical prefilter.
c Designed to operate before any
pump-fed biological filter for fishponds
anging from 7,000 to 16,000 litres, the
r Saturn Booster will remove up to 75% of pond debris. This reduces filter maintenance
nd improves the biological performance of
a your existing filter.
This appliance is not intended for use by persons (including children) with reduced
hysical, sensory or mental capabilities,
p or lack of experience and knowledge, unless they have been given supervision
r instruction concerning use of the
o appliance by a person responsible for their safety. Children should be
upervised to ensure that they do not
s play with the appliance. (Australia & NZ only) This appliance is not intended for
se by young children or infirm persons
u unless they have been adequately supervised by a responsible person to
nsure that they can use the appliance
e safely. Young children should be supervised to ensure that they do not
lay with the appliance.
p
DESCRIPTION
Dirty water from the pond is pumped into the Saturn Booster and spun around a circular polyester mesh filter. Most particles are trapped by the mesh and then removed by a rotating jet. Dislodged particles fall into a large waste collection area at the bottom, while the cleaned water passes through to your existing filter system.
As it is a sealed unit, waste removal from the Saturn Booster is simply a matter of lifting the flush-away handle for a few seconds every week.
The Saturn Booster is designed for simple retrofitting into an existing installation. The hosetails supplied allow connection to 25mm, 32mm or 40mm hose.
To ensure reliable operation, there are two valves built into the inlet assembly. These are colour coded – blue and red.
The red valve is a filter bypass valve and prevents damage to the Saturn Booster if for whatever reason pressure rises above safe levels. The valve protects the Saturn Booster by redirecting the flow back to pond via the lower hose connection on the inlet assembly.
The blue valve is a self-regulating pressure sensitive relief valve, which ensures optimum operation by controlling the pressure differential across the filter mesh inside the Saturn Booster. Depending on the flow rate and level of debris, the valve can move down during normal operation, indicating that it is regulating the pressure.
SAFETY AND ELECTRICAL CONNECTIONS
• Always disconnect the electricity supply before starting to handle, maintain, repair or install any pond equipment.
• This product is not submersible, and should be sited where it cannot fall into the water or become waterlogged. However, the design is weatherproof, and the Saturn Booster can be safely installed outdoors.
• This product is supplied with 10m of 3 core electric cable for connection to the mains supply. The termination to the
mains supply should be permanent, inside a dry, weatherproof enclosure,
hrough a double pole switched fused
t spur with a minimum contact gap of 3mm – ‘(disconnector) to BS 3676’ – and
itted with a 3 amp fuse.
f
THIS APPLIANCE MUST BE EARTHED AND IT IS ESSENTIAL THAT THE CONNECTIONS ARE MADE USING THE FOLLOWING CODE;
rown - Live
B Blue - Neutral
reen/Yellow -
G
arth
E
The BROWN lead should be connected
o the LIVE terminal which may be
t marked with an 'L' or coloured brown or red. The BLUE lead should be connected to the NEUTRAL terminal which may be marked with an 'N' or
oloured blue or black. The
c GREEN/YELLOW lead should be connected to the EARTH terminal which may be marked with an 'E' or coloured green or green/yellow.
• Exposed cable runs should be sensibly positioned and protected if necessary by armoured conduit.
• A 10mA or 30mA Residual Current Circuit Breaker (RCD) MUST be fitted to the mains supply.
• Permanent installations to the mains supply (hard wiring) must comply with the regulations of your local authority. Contact your local authority building control department for advice before you start installation and they will let you know how to get your installation approved.
• If in any doubt about wiring to the mains supply, consult a qualified electrician or your local authority.
• The pump is fitted with 10m of 3 core electric cable which is permanently connected and sealed to the motor.
The supply pump cable cannot be replaced. If the cable is damaged, the pump should be removed and discarded and replaced with a new pump.
• Protect from frost if the unit is not run year round, by draining and removing to a store in a dry, frost protected place.
• When full of water, the Saturn Booster weighs nearly 100kg. DO NOT attempt to move when full of water. To drain, pull up the flush handle to empty some of the water, and then gently tilt the Booster until most of the water is emptied.
IMPORTANT NOTE: The Booster is a sealed product and can be installed below pond level. If you plan to bury it you will have to remove the lid and siphon or ladle the water out to empty it (for winter storage). Never completely bury the Booster. Ensure the lid and valve housing are above ground as shown in Fig. 4.
1. INSTALLATION
Important:
The Saturn Booster can be fitted in a wide variety of installations. However the following conditions must be met:
• Water flow through the Saturn Booster must be between 3500 litres per hour and 8000 litres per hour.
• The Saturn Booster has to be connected
to an in-pond pump i.e. it is not suitable for gravity-fed installations.
• Ensure the in-pond pump is raised 00mm (9”) above the bottom of the
2 pond. This will prevent any sediment on the pond floor overwhelming your filter,
nd in the event of a leak outside the
a pond, prevent your pond from being completely emptied. If the pond has a lot
f debris on the bottom, it is always best
o to remove it with a pond vacuum before installing a new filter.
• The Saturn Booster must be installed irectly after the in-pond pump and
d before
both the Filter and Ultra Violet
Clarifier (UVC). The pump supplying the Saturn Booster
must not have a maximum head exceeding 6m (9 psi, 0.6 bar).
• The outlet and flush away hoses must not
rise more than 1m above their
onnection to the outlet assembly.
c
o complete the installation you will need
T two additional hoses:
1. One of 25mm, 32mm or 40mm diameter
to take the waste from the Saturn
ooster to a convenient flower bed or
B drain (the ‘Flush Away Hose’)
2. A hose with the same diameter as your
existing pond pump hose to connect from the filter bypass valve on the Saturn Booster back to your pond (the ‘Bypass’ hose).
Assembly
Unpack all contents from the box (Fig 1). The Booster only requires the fitting of the
inlet assembly (see Fig 2)
• Gently push the inlet assembly into the
lid carefully aligning the two valves (Fig 2B)
• Tighten the two bolts using the Allen Key
supplied (Fig 2C)
Installation
The Saturn Booster should be sited out of the pond in a position that is easily accessible and where the waste hose can be run to a convenient flowerbed or drain. The Saturn Booster should be connected directly to your in pond pump hose (i.e. before your Filter [and UVC if fitted]) (Fig 3). The outlet and waste hoses must not be raised more than one metre above the Saturn Booster (Fig 4); otherwise the filter bypass valve will affect the performance of the Saturn Booster.
The Saturn Booster should sit on a smooth and level surface eg. a paving slab.
Inlet and Outlet Hoses:
• Cut your existing hose with a hacksaw at
the position where the Booster will be installed, noting that the hose length between the Booster and your filter should be no more than 2m (Fig 5).
• If using 32mm or 40mm hose, cut two of
the hosetails supplied with a hacksaw to suit (Fig 6) and attach to the top connection on both the inlet assembly and outlet assembly.
• Wrap the adhesive foam strips around
the hose and position the jubilee clips over the foam strips to connect the hose from the pond pump to the inlet assembly hosetail (Fig 7A), and the hose to your filter to the outlet assembly hosetail (Fig 7B).
Flush-Away Hose:
The flush-away hose can have a diameter of 25mm, 32mm or 40mm and connects to the
Loading...
+ 2 hidden pages