The pump is electrically operated and is designed to pump solid particles up to 4mm in diameter with minimal pre-strainer maintenance. These types of pumps are particularly suitable for pumping water to external filters or for use in high flow waterfalls or water course applications where low maintenance is important. The pump does not use oil or grease for lubrication and can be used safely in ponds containing fish or plants. The motor consists of a sealed stator and water-cooled rotor. All electrical components are isolated from the water.
WARNING: SAFETY AND ELECTRICAL CONNECTIONS.
1. The pump is supplied with 10m of 3 core electric cable which is permanently connected and sealed to the motor.
The supply cable cannot be replaced. If the cable is damaged, the pump should be discarded.
This product is designed to be permanently wired to the mains supply in a dry weatherproof enclosure through a Double-Pole Switched Fused Spur ­(Disconnector) to BS 3676 - with a minimum contact gap of 3mm in each pole. Fitted with a 3 or 5 Amp fuse.
The installation must conform to
the National and Local wiring regulations which could include the use of plastic or metal conduit to protect the cable.
2. A 10mA or 30mA Residual Current Device (RCD) Must be fitted to the mains supply.
3. WARNING: This appliance must be earthed and it is essential that the connections are made using the following code;
Brown - Live
Blue - Neutral
Green/Yellow - Earth
The BROWN lead should be connected to the LIVE terminal which may be marked with an ‘L’ or coloured brown or red.
The BLUE lead should be connected to the NEUTRAL terminal which may be marked with an ‘N’ or coloured blue or black.
The GREEN/YELLOW lead should be connected to the EARTH terminal which may be marked with an ‘E’
( ) or
coloured green or green/yellow.
4. If an extension cable is required, this should be connected to the end of the pump cable using a weatherproof cable connector. The joint must be positioned in a suitable dry housing. The extension cable should be of 3 core 0.75mm
2
Polychloroprene rubber insulated cable (ref: HO5 RN-F) and permanently wired to the mains supply with a 3 or 5 Amp fuse.
5. The pump cable (and extension cable) should be positioned and adequately protected against damage especially where contact with gardening equipment, (lawn mowers, forks etc..) children and domestic animals may occur.
6. Consult a qualified electrician or local authority if in any
doubt about wiring to the mains supply.
IMPORTANT
1. WARNING: Always unplug or disconnect all appliances in the pond from the electricity supply before putting your hands in the water whilst equipment is being installed, repaired, maintained or handled.
2. Do not use the supply cable to lift the pump, as this may cause damage. We recommend fitting a lifting cord to the handle on the top of the strainer cage when the pump is installed in deep water.
3. Do not operate or leave the pump in freezing conditions.
4. Do not allow the pump to run dry.
5. Do not operate this pump without the strainer cage attached. Using the pump without a filter may invalidate your warranty.
PUMP ASSEMBLY.
1. Un-pack the ball joint assembly (A in Fig 1) from the accessory pack.
2. Rotate the three lid latching knobs to the open position and lift the Strainer Cage Top from the Strainer Base (B in Fig 1).
3. Firmly pull the pump out of its location (C in Fig 1).
4. Checking that the ball joint’s inlet and outlet bosses are in line, offer the female threaded nut to the male threaded pump chamber outlet (D in Fig 1) and firmly screw them together.
5. Place the pump back into the location, reposition the lid and rotate the lid latching knobs back to the locked position.
PUMP INSTALLATION.
ATTENTION: This product is not suitable for water temperatures above 35ºC
Position
1. For the best results, the pump should be positioned in the deepest part of the pond. This will ensure the best circulation of water in the pond and when being used as a Filtration pump, its solids handling capability will be maximised.
Waterfall or Pond Filter Only.
ATTENTION
AUTOMATIC CUT-OUT. To help
ensure your pump’s long life and to prevent damage, it is fitted with automatic thermal overload protection. This switches off the pump if it overheats. If this occurs, switch off the power at the mains supply to the pump. Check for the cause. Usually it will be debris blocking the inlets of the pump or obstructing the impeller. Remove the obstruction and wait 15 minutes for the pump to cool down and automatically reset. Then switch on the pump again.
NOTE: YOU MUST SWITCH OFF THE MAINS SUPPLY BEFORE THE PUMP WILL RESET.
From 1st January 2005 installing this product in the garden is classed as 'notifiable' in the revised Building Regulations for England and Wales. The Regulations now require you to tell your local authority building control department that you intend to install this product before installation. Your local authority will let you know how you can get your installation approved.