Hozelock Ecopower+ 2500, Ecopower+ 5000, Ecopower+ 10000 Installation And Operating Instructions Manual

Ecopower+
2500/5000/10000
INSTALLATION AND OPERATING INSTRUCTIONS.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION,
AND KEEP FOR FUTURE REFERENCE.
1347
1349
Fig 4
Fig 6
Fig 1-a
Fig 1-c
Fig 1-b
Fig 2
A
Fig 3
Fig 7
I
J
1348
Hozelock Cyprio Ecopower+ garden pond filters can be sited almost anywhere. (See a,b,c Fig 1) and teamed with the appropriate pond pump, they will remove unwanted solids from the water and convert dissolved organic and chemical fish waste i
nto harmless compounds. In addition, these combined filter/UVC units will give G
uaranteed Clear Water if the advice given in the Hozelock Cyprio Filter Equipment S
election Chart and in these instructions is
a
dhered to.
S
AFETY AND ELECTRICAL CONNECTIONS
From 1st January 2005 installing this product in the garden is classed as 'notifiable' in the revised Building Regulations for England and Wales. The R
egulations now require you to tell your local authority building control d
epartment that you intend to install this p
roduct before installation. Your local a
uthority will let you know how you can get your installation approved.
Safety Information
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
(Australia & NZ only) This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
!
Always disconnect all equipment in the pond before starting to handle, maintain, repair or install any pond equipment.
!
This product is
NOT SUBMERSIBLE
, and should be sited where it cannot fall into the water or become waterlogged. However, the design is weatherproof and Ecopower+ filters can be safely installed outdoors.
!
Important – This product is not suitable for use in direct sunlight over long periods of time, as this may cause the product to overheat.
!
Direct exposure to ultra-violet light can damage eyes and skin.
DO NOT
attempt to view the ultra-violet lamp when lit. To check the lamp look at the opaque inlet Connector (See ‘A’ Fig 2) which will glow when the lamp is on.
!
This product is supplied complete with 5m of 3 core electric cable. For connection to the mains supply, use only three-core cable Ref: HO5 RN-F. This has a minimum copper cross-section of 0.75mm
2
with
Polychloroprene Rubber Insulation. The
termination to the mains supply should
be permanent, inside a dry weatherproof enclosure, through a double pole switched fused spur with a minimum contact gap of 3mm - (disconnected) to BS 3676 - and fitted with a 3 or 5 amp fuse.
!
Exposed cable runs should be sensibly
p
ositioned, and protected if necessary by armoured conduit, especially if contact is l
ikely with gardening equipment such as forks and lawn mowers, or children and a
nimals.
!
A
10mA or 30mA Residual Current Circuit
B
reaker (RCD) MUST be fitted to the mains
supply.
!
Permanent installations to the mains supply (hard wiring) must comply with the regulations of the local electricity authority, which may stipulate the use of plastic or metal conduit to protect the cable.
!
If in any doubt about wiring to the mains supply, consult a qualified electrician or your local electricity authority.
!
Protect from frost. In cold winter weather (when fish are not active and algae growth c
eases), the unit may be switched off. It should then be drained of water, removed (
if possible) from its installation and stored
i
n a dry, frost-protected area.
SIZING THE EQUIPMENT
The Filter Equipment Selection Chart overleaf gives general guidelines on the specifications of pump, filter, UV and flexible hose diameter for garden ponds up to 10000 litres (2200 gallons), with stocking options for goldfish or Koi. For best results the following condition factors must also be taken into account.
DEPTH
Hozelock Cyprio recommends a minimum depth of 1.2m (4’) for Koi ponds. For a pond with an average depth of less than 0.75m (2’ 6”) the Condition Factor is + 25% (ie add 25% to the pond volume if less then 0.75m deep) Shallow ponds are subject to full penetration of sunlight, and warm up quickly. This encourages the growth of algae.
INSTALLATION
Locate the Ecopower+ on firm, level ground where you can access it conveniently for maintenance.
LOCATION
Pond location determines the daily amount of sunlight or shade a pond receives. Ponds exposed to full sunshine throughout the day have a Condition Factor of +25%.
CLIMATE
Climate affects water temperatures and fish activity rate/feeding requirements. The more active the fish, the greater the demands on the filtration system. In hot climates (i.e. South Africa), the Condition Factor is +35% In temperate climates (i.e. Southern Europe), the Condition Factor is +15% In a Northern European climate (i.e. most areas of Great Britain), the Condition Factor is +0%.
EXAMPLE
You have a 2250 litres (500 gallon) goldfish pond 0.6m (2’) deep (Condition Factor +25%). You live in London - a Northern European climate (Condition Factor +0%). The pond is exposed to full sunlight (+25%). The effective volume of your pond is therefore increased by 50% (25% + 25%), and you would need to size your equipment as though your pond held 3375 litres (750 gallons)
1.0 Wiring and Installation Important:
The pump supplying this unit must not have a maximum head exceeding 6m (3.8 PSI, 0.3 Bar) The table in these instructions will guide you through the best pump to be
fitted with your filter. This product is designed to be permanently wired to a mains supply housed in a dry, weatherproof enclosure. Once installed the water will flow through the filter as shown in Fig 3
1.1
Ecopower+ filters are pump-fed, external filters with an integral UVC unit, i
deal for being partially buried adjacent to your pond or being positioned above ground if desired. The filter may also be concealed at the top of a waterfall (See a, b, c Fig 1) I
f you choose to part-bury your Ecopower+ filter, the excavation should be firmly backfilled with compacted sand or soil to support the unit.
1.2E
copower+ filters incorporate inlet hose
tails to fit 20 - 40mm (
3
⁄4” – 11⁄2”) hose (refer to Equipment Selection Chart overleaf) and an outlet hose tail to fit 40mm (1 1⁄2”) hose. The pump inlet and f
ilter outlet pipe should be at opposite
e
nds of the pond for optimal water circulation in the pond. Bear this in mind when purchasing, measuring and cutting t
he hose.
1.3C
ut the inlet hose tail on your
E
copower+ Filter to the size appropriate for the diameter of the hose to be used (see Fig 4). Then connect the hose from your pump to this inlet hose tail and secure with hose clips, available separately, to ensure there are no leaks. Do not overtighten.
1.4
The filter outlet connector and overflow moulding (x2 on Ecopower+ 9000) should be secured to the side of the vessel (See Fig 5). The outlet hose (if fitted) should be secured in the same way as the inlet hose. Avoid kinks and bends, and keep hose runs as short as possible (preferably less than 1m) to minimise flow restrictions.
1.5 The supply cable cannot be replaced. If
the cable is damaged, the unit should be discarded.
! WARNING:
This appliance MUST be earthed, and it is essential that the connections be made using the following code:
• The
BROWN
lead should be connected
to the
LIVE
terminal marked ‘L’.
• The
BLUE
lead should be connected to
the
NEUTRAL
terminal marked ‘N’.
• The
GREEN/YELLOW
lead should be
connected to the
EARTH
terminal
marked ‘ ‘
1.6
Wet Test: It is essential that the unit is wet tested before connecting to the mains electricity. With the electrical cover / viewing hatch removed, connect the hoses to the inlet and outlet as described in 1.4 above. Switch on the
PUMP ONLY
and run for an hour. Inspect the top of the unit and inside the quartz glass tube for leaks (see ‘F’ Fig 9). If any leaks are detected return the filter to the retailer. This test should be repeated when the quartz glass tube is changed.
2.0 UVC LAMP REPLACEMENT
Ecopower+ is supplied with a UVC lamp fitted.
!
The effective life of a double-ended UV lamp is 12 months in continuous use, after which time the lamp should be replaced. Even though it may still glow the light emitted is not powerful enough to treat the water
2.1
Switch off and isolate (by removing the fuse) the pump supplying water to the filter and the power supply to the Ecopower+ unit.Remove the electrical cover / viewing hatch (see 1.5a).
2.2
Pull off the lamp terminals (see ‘G’ Fig
12) from both ends, and slide the ‘old’ lamp out of the quartz tube (see ‘H’ Fig
13). Slide the ‘new’ lamp into the quartz tube and push the lamp terminals onto
2
Loading...