Hozelock Cyprio Ecopower+ garden pond
filters can be sited almost anywhere. (See
a,b,c Fig 1) and teamed with the
appropriate pond pump, they will remove
unwanted solids from the water and convert
dissolved organic and chemical fish waste
i
nto harmless compounds. In addition, these
combined filter/UVC units will give
G
uaranteed Clear Water if the advice given
in the Hozelock Cyprio Filter Equipment
S
election Chart and in these instructions is
a
dhered to.
S
AFETY AND ELECTRICAL
CONNECTIONS
From 1st January 2005 installing this
product in the garden is classed as
'notifiable' in the revised Building
Regulations for England and Wales. The
R
egulations now require you to tell your
local authority building control
d
epartment that you intend to install this
p
roduct before installation. Your local
a
uthority will let you know how you can
get your installation approved.
Safety Information
The appliance is not intended for
use by persons (including children)
with reduced physical, sensory or
mental capabilities, or lack of
experience and knowledge, unless
they have been given supervision
or instruction concerning use of
the appliance by a person
responsible for their safety.
Children should be supervised to
ensure that they do not play with
the appliance.
(Australia & NZ only) This
appliance is not intended for use
by young children or infirm
persons unless they have been
adequately supervised by a
responsible person to ensure that
they can use the appliance safely.
Young children should be
supervised to ensure that they do
not play with the appliance.
The appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.
!
Always disconnect all equipment in the
pond before starting to handle, maintain,
repair or install any pond equipment.
!
This product is
NOT SUBMERSIBLE
, and
should be sited where it cannot fall into the
water or become waterlogged. However,
the design is weatherproof and Ecopower+
filters can be safely installed outdoors.
!
Important – This product is not suitable
for use in direct sunlight over long periods
of time, as this may cause the product
to overheat.
!
Direct exposure to ultra-violet light can
damage eyes and skin.
DO NOT
attempt to
view the ultra-violet lamp when lit. To check
the lamp look at the opaque inlet
Connector (See ‘A’ Fig 2) which will glow
when the lamp is on.
!
This product is supplied complete with 5m
of 3 core electric cable. For connection to
the mains supply, use only three-core cable
Ref: HO5 RN-F. This has a minimum copper
cross-section of 0.75mm
2
with
Polychloroprene Rubber Insulation. The
termination to the mains supply should
be permanent, inside a dry weatherproof
enclosure, through a double pole switched
fused spur with a minimum contact gap of
3mm - (disconnected) to BS 3676 - and fitted
with a 3 or 5 amp fuse.
!
Exposed cable runs should be sensibly
p
ositioned, and protected if necessary by
armoured conduit, especially if contact is
l
ikely with gardening equipment such as
forks and lawn mowers, or children and
a
nimals.
!
A
10mA or 30mA Residual Current Circuit
B
reaker (RCD) MUST be fitted to the mains
supply.
!
Permanent installations to the mains
supply (hard wiring) must comply with the
regulations of the local electricity authority,
which may stipulate the use of plastic or
metal conduit to protect the cable.
!
If in any doubt about wiring to the mains
supply, consult a qualified electrician or your
local electricity authority.
!
Protect from frost. In cold winter weather
(when fish are not active and algae growth
c
eases), the unit may be switched off. It
should then be drained of water, removed
(
if possible) from its installation and stored
i
n a dry, frost-protected area.
SIZING THE EQUIPMENT
The Filter Equipment Selection Chart
overleaf gives general guidelines on the
specifications of pump, filter, UV and
flexible hose diameter for garden ponds up
to 10000 litres (2200 gallons), with stocking
options for goldfish or Koi. For best results
the following condition factors must also be
taken into account.
DEPTH
Hozelock Cyprio recommends a minimum
depth of 1.2m (4’) for Koi ponds. For a pond
with an average depth of less than 0.75m (2’
6”) the Condition Factor is + 25% (ie add
25% to the pond volume if less then 0.75m
deep) Shallow ponds are subject to full
penetration of sunlight, and warm up
quickly. This encourages the growth of
algae.
INSTALLATION
Locate the Ecopower+ on firm, level
ground where you can access it
conveniently for maintenance.
LOCATION
Pond location determines the daily amount
of sunlight or shade a pond receives. Ponds
exposed to full sunshine throughout the day
have a Condition Factor of +25%.
CLIMATE
Climate affects water temperatures and fish
activity rate/feeding requirements. The more
active the fish, the greater the demands on
the filtration system.
In hot climates (i.e. South Africa), the
Condition Factor is +35%
In temperate climates (i.e. Southern
Europe), the Condition Factor is +15%
In a Northern European climate (i.e. most
areas of Great Britain), the Condition Factor
is +0%.
EXAMPLE
You have a 2250 litres (500 gallon) goldfish
pond 0.6m (2’) deep (Condition Factor
+25%). You live in London - a Northern
European climate (Condition Factor +0%).
The pond is exposed to full sunlight (+25%).
The effective volume of your pond is
therefore increased by 50% (25% + 25%),
and you would need to size your equipment
as though your pond held 3375 litres (750
gallons)
1.0 Wiring and Installation
Important:
The pump supplying this unit must not have
a maximum head exceeding 6m (3.8 PSI, 0.3
Bar) The table in these instructions will
guide you through the best pump to be
fitted with your filter. This product is
designed to be permanently wired to a
mains supply housed in a dry, weatherproof
enclosure. Once installed the water will flow
through the filter as shown in Fig 3
1.1
Ecopower+ filters are pump-fed,
external filters with an integral UVC unit,
i
deal for being partially buried adjacent
to your pond or being positioned above
ground if desired. The filter may also be
concealed at the top of a waterfall (See
a, b, c Fig 1)
I
f you choose to part-bury your
Ecopower+ filter, the excavation should
be firmly backfilled with compacted sand
or soil to support the unit.
1.2E
copower+ filters incorporate inlet hose
tails to fit 20 - 40mm (
3
⁄4” – 11⁄2”) hose
(refer to Equipment Selection Chart
overleaf) and an outlet hose tail to fit
40mm (1 1⁄2”) hose. The pump inlet and
f
ilter outlet pipe should be at opposite
e
nds of the pond for optimal water
circulation in the pond. Bear this in mind
when purchasing, measuring and cutting
t
he hose.
1.3C
ut the inlet hose tail on your
E
copower+ Filter to the size appropriate
for the diameter of the hose to be used
(see Fig 4). Then connect the hose from
your pump to this inlet hose tail and
secure with hose clips, available
separately, to ensure there are no leaks.
Do not overtighten.
1.4
The filter outlet connector and overflow
moulding (x2 on Ecopower+ 9000) should
be secured to the side of the vessel (See
Fig 5). The outlet hose (if fitted) should
be secured in the same way as the inlet
hose. Avoid kinks and bends, and keep
hose runs as short as possible (preferably
less than 1m) to minimise flow
restrictions.
1.5 The supply cable cannot be replaced. If
the cable is damaged, the unit should be
discarded.
! WARNING:
This appliance MUST be earthed, and it is
essential that the connections be made
using the following code:
• The
BROWN
lead should be connected
to the
LIVE
terminal marked ‘L’.
• The
BLUE
lead should be connected to
the
NEUTRAL
terminal marked ‘N’.
• The
GREEN/YELLOW
lead should be
connected to the
EARTH
terminal
marked ‘ ‘
1.6
Wet Test: It is essential that the unit is
wet tested before connecting to the
mains electricity. With the electrical cover
/ viewing hatch removed, connect the
hoses to the inlet and outlet as described
in 1.4 above. Switch on the
PUMP ONLY
and run for an hour. Inspect the top of
the unit and inside the quartz glass tube
for leaks (see ‘F’ Fig 9). If any leaks are
detected return the filter to the retailer.
This test should be repeated when the
quartz glass tube is changed.
2.0 UVC LAMP REPLACEMENT
Ecopower+ is supplied with a UVC lamp
fitted.
!
The effective life of a double-ended UV
lamp is 12 months in continuous use, after
which time the lamp should be replaced.
Even though it may still glow the light
emitted is not powerful enough to treat the
water
2.1
Switch off and isolate (by removing the
fuse) the pump supplying water to the
filter and the power supply to the
Ecopower+ unit.Remove the electrical
cover / viewing hatch (see 1.5a).
2.2
Pull off the lamp terminals (see ‘G’ Fig
12) from both ends, and slide the ‘old’
lamp out of the quartz tube (see ‘H’ Fig
13). Slide the ‘new’ lamp into the quartz
tube and push the lamp terminals onto
2