Specification Sheet
11/27/2013
Fluorescent Stairwell Fixture
4 Foot; Operates up to three lamps
Fluorescent Stairwell Series
Applications
Stairwell Lighting
Shop/Sheds
Task Lighting
Storage Areas
Egress
Restrooms
Hallways
Laundry Rooms
SW4 Series
Project:
Catalog#:
Approved by:
Description
The SW4 Stairwell series fluorescent strip fixture
exemplifies durability, versatility, and functionality.
This fixture operates two 4’ linear fluorescent lamps
using a Program Rapid Start (PRS) ballast and highly
advanced ultrasonic motion sensor. It also has a 2’
linear fluorescent 17W lamp driven by an instant start
ballast that stays on at all times providing minimal light
when unoccupied.
The low voltage ultrasonic sensor allows the fixture
to detect movement around corners and in any open
space, even with obstacles blocking the line of sight
from the sensor. This bi-level system provides optimal
energy savings over the life of the fixture. Consult
factory for further details.
Features
Model Ordering (see page 2 for more options)
SW4 W BAA MV 00U 00 0I
SW4 Stairwell 4-Foot Fixture
(W) White Lens
(B) Ballast upon occupancy
2x32w Program Rapid Start Normal Ballast
Factor Ballast
(A) Ballast with continuous operation
1x17w Instant Start Low Ballast Factor Ballast (16W)
(MV) Multi-volt (120-277v)
(U) Ultrasonic Sensor
Standard Disconnect; no cordset
Individual Box
Howard offers an ies file from a 3rd party laboratory that is accurate
to the best of our ability. This file can be used to simulate light levels
for each particular application. Ultimately it is the responsibility of
the design engineer or lighting designer to coordinate with all local
authorities having jurisdiction to define requirements throughout
the design process. There must be a clear understanding of the
jurisdictional authority’s interpretation of the required light levels for
egress to avoid significant problems following the construction phase.
Additionally, egress light levels need to fall within prescribed energy
codes and other design criteria adopted in the project area. For more
on this subject please see the following web site.
ecmweb.com/content/exterior-egress-lighting-requirements
• Construction
-Die-formed 22 gauge steel
-High gloss, baked enamel finish
-High quality lamp holders
-NEC compliant luminaire power disconnect
standard
• Installation
-Shipped fully wired with ballast
-Simple screw driver assembly
-Easy access to lamp compartment with removal
of snap-in lens diffuser
-Tamper-proof version also available
-Numerous knockouts on back and ends
-Surface mount
• Ballast
-Electronic, Inherent Thermal Protection, Class P,
Sound rated A
-UL Listed
• Occupancy Sensor
-Ultrasonic
• Quality Assurance
-System Tested, Designed, Approved, and
Manufactured in Mendenhall, Mississippi.
Specifications subject to change without notice.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Specification Sheet
11/27/2013
SW4 Series
Fluorescent Stairwell Fixture
Project:
4 Foot; Operates up to three lamps
Catalog#:
Approved by:
Ordering Information
Cordset Options
Model
Family
Lens
SW4 W B A A MV 00U 00 0 I
SW4 W: White lens A: 2x32w T8
Fluorescent Stairwell Series
Ballast upon
Occupancy
Program Rapid
Start Low Ballast
Factor Ballast
B: 2x32w T8
Program Rapid
Start Normal
Ballast Factor
Ballast
C: 2x32w T8
Program Rapid
Start High Ballast
Factor Ballast
(1)
(1)
(1)
Ballast with
Continuous Operation
A: 1x17w T8
Instant Start Low Ballast
Factor Ballast
B: 1x17w T8
Instant Start Normal Ballast
Factor Ballast
C: 1x17w T8
Instant Start High Ballast
Factor Ballast
L: 1x16w T8 LED 4100K
N: None
3000
3500
4100
5000
3000
3500
4100
5000
(2)
High
Lumen
Yes
Yes
Yes
Yes
Input Volts Factory Installed Options
T8
X
X
X
X
X
X
X
X
B: Em. Ballast(500 Lumen)
Occupancy Sensors*
U: Ultrasonic Occ Sensor
*Other sensors available upon request
CRI/CCT
A: No Lamps MV: 120-277v 000: No FIOs
CRI CCT
F:
85
G:
85
H:
85
I:
85
K:
85
L:
85
M:
85
N:
85
(see customer service
for
other cordset options)
(4)
(3)
00: Standard Disconnect
01: 6’ SJT 18/3, no plug
02: 10’ SJT 18/3, no plug
T
BAPack.
I: Single
(1) High Efficiency ballasts are CEE Listed.
(2) Lamp installation available.
(3) Occupancy Sensors should be used with programmed rapid start ballasts for maximum lamp life.
Standard Occupancy Sensor requires neutral wired fixtures (ex. -120v or -277v).
For phase-to-phase voltage applications (240v) advise Customer Service at time of request.
(4) 500 Lumen Emergency Ballast (120-277v only)
Specifications subject to change without notice.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
Sample Ordering Number:
SW4 W BA A MV 00U 00 0I
SW4 Stairwell 4-Foot Fixture
(W) White Lens
(B) Ballast upon occupancy
2x32w Program Rapid Start Normal Ballast Factor Ballast
(A) Ballast with continuous operation
1x17w Instant Start Low Ballast Factor Ballast (16W)
(A) No lamps installed
(MV) Multi-volt (120-277v)
(U) Ultrasonic Sensor
Standard Disconnect; no cordset
Individual Box
www.HowardLightingProducts.com