HigH inTensiTy DisCHarge (HiD) ballasTs
Core and Coil Ballasts Identifying the Ballast Model Number
1
Lamp Type
Ballasts
Electronic
HID Ballast Model Number example: Metal Halide (M), 400 watt (0400), 120/208/240/277 line voltage (71), *core and coil (C), CWA circuit (2), 60 line frequency/1lamp (1), standard design (1), replacement kit (K).
M
Column 1:
Selects the proper lamp type. M = Metal Halide/Pulse Start MH S = High Pressure Sodium
Compact
Fluorescent Ballasts
HID
Ballasts
MS = Metal Halide/High Pressure Sodium
Column 2 3 4 5:
Selects the proper lamp wattages. 0035 = 35 Watt 0050 = 50 Watt 0070 = 70 Watt 0100 = 100 Watt 0150 = 150 Watt 0175 = 175 Watt 0250 = 250 Watt 0320 = 320 Watt 0350 = 350 Watt 0400 = 400 Watt 0750 = 750 Watt 0875 = 875 Watt 1000 = 1000 Watt 1500 = 1500 Watt
Column 6 7:
Selects the proper input operating voltages.
120 0 2 120/277 2 3 120T/480 2 9 120/208/240/277 7 1 120/208/240/277/480 8 1
2 3 4 5
Lamp Code
0400
LAMP CODE
LAMP WATTAGE
LINE VOLTAGE
6 7 8 9
Case Type
Line Voltage
Circuit Type
Frequency, number of
lamps and insulation
7 1 C
CASE TYPE
Column 8:
Indicates the type of case used. Case Construction Type.
Core and Coil C Utility - Tabbed U
CIRCUIT TYPE
Column 9:
Indicates the type of circuit used. Design Type
R-HPF - Reactor 1 CWA - Constant Wattage Auto Transformer 2 HX-HPF - High Reactance-High Power Factor 5 PS-CWA - Pulse Start Constant Wattage Autotransformer 6 Multiple Lamp Reactor 8 Multiple Lamp CWA 9
LINE FREQUENCY AND NUMBER OF LAMPS
Column 10:
Ballast operating frequency and total number of lamps that the ballast can operate at any one time.
Frequency No. of Lamps Insulation Class
60 1 H (180) 1
60 1 N (200) 2
60 1 H (180) E
* E = EISA 2007 Compliant (Circle E)
E
2
10 11
Design
12
Accessories
Updates
1 1
DESIGN UPDATES
Column 11:
Indicates design revisions that are deemed signifi­cant enough for a model number change.
ACCESSORIES
Column 12:
Accessory codes are used to specify components included in the ballast order. This code is not part of the model number included on the label, but will be used as an extension to
identify accessories.
CORE AND COIL ONLY NO SUFFIX Ballast with welded bracket B Ballast with oil cap C Ballast with dry cap D Ballast with standard starter E
K
42
42
*Disclaimer: All possible ballast product numbers might not be available. Please consult factory before ordering.
Howard-Lighting.com | 800.956.3456 | Fax 601.422.1652
Ballast Kits Identifying the Ballast Model Number
Lamp Type Wattage Input Volts Circuit Type Packaging
M - 400 - 4T - CWA - K
M - Metal Halide 175
250 400 1000 1500
MP - 400 - 4T - PSCWA - K
MP - Pulse Start Metal Halide 50
70 100 150 250 400 750 875 1000
S - 150 - 4T - HXH - K
S - High Pressure Sodium 35
50 70 100 150 250 400 1000
LAMP TYPE WATTAGE INPUT VOLTS
4T 5T 480T
2T 4T 5T
120 4T 5T
CWA Kit
HXH PSCWA
RXN RXH HXH CWA
Kit
Kit
Electronic
Ballasts
Fluorescent Ballasts
Compact
Ballasts
HID
M = Metal Halide
MP = Pulse Start MH
S = High Pressure Sodium
Metal Halide - 175, 250, 400, 1000, 1500
Pulse Start - 50, 70, 100, 150, 250, 400, 1000
High Pressure Sodium - 35, 50, 70, 100, 150, 250,
400, 1000
CIRCUIT TYPE PACKAGING
RXN - Reactor Normal Power Factor* RXH - Reactor High Power Factor HXN - High Reactance Normal Power Factor* HXN - High Reactance High Power Factor CWA - Constant Wattage Autotransformer PSCWA - Pulse Start CWA
* For Normal Power Factor High Reactance and Reactor ballasts, the ballast operates without the use of a capacitor. Therefore, a capacitor will not be included with the kit. For all other
circuit types, a capacitor is included and standard.
Metal Halide Ballast Kit
• Ballast
• Capacitor
• Mounting Bracket
Howard-Lighting.com | 800.956.3456 | Fax 601.422.1652
Pulse Start Ballast Kit
• Ballast
• Capacitor*
• Starter
• Mounting Bracket
2T - 120/277v
4T - 120/208/240/277v
5T - 120/208/240/277/480v
120 - 120v
480T - 120T/480v
K - Kit
High Pressure Sodium Ballast Kit
• Ballast
• Capacitor*
• Starter
• Mounting Bracket