Howard Industries HID Ballast Specifications

HigH inTensiTy DisCHarge (HiD) ballasTs
HID Ballast Kits
New Kit Model # Core and Coil Model
M-175-4T-CWA-K M0175-71C-2XX
M-175-5T-CWA-K M0175-81C-2XX
M-250-4T-CWA-K M0250-71C-2XX
M-250-5T-CWA-K M0250-81C-2XX
M-400-4T-CWA-K M0400-71C-2XX
Ballasts
Electronic
M-400-5T-CWA-K M0400-81C-2XX
M-1000-4T-CWA-K M1000-71C-2XX
M-1000-5T-CWA-K M1000-81C-2XX
M-1500-4T-CWA-K M1500-71C-2XX
MP-50-2T-HXH-K M0050-23C-1XX
MP-70-4T-HXH-K M0070-71C-5XX
MP-100-4T-HXH-K M0100-71C-5XX
MP-150-4T-HXH-K M0150-71C-5XX
MP-250-4T-PSCWA-K M0250-71C-6XX
MP-320-4T-PSCWA-K M0320-71C-6XX
Compact
Performance:
Fluorescent Ballasts
HID
Ballasts
44
44
Ballast
applicable ANSI specifications including ANSI C82.4.
• Ballast shall be designed with Class “H” (180°C)
or higher insulation system.
Ballasts shall be designed to operate for 60,000 hours of continuous operation at their maximum rated temperature.
Ballast and starter combinations shall operate reliably at starting temperatures of -40°C for High Pressure Sodium ballasts and -30°C for Metal
Halide ballasts at nominal line voltage of plus or minus 10%.
All HID ballast shall have a nominal ballast factor of 1.0.
Regulatory:
Manufacturer shall provide written warranty against defects in material or workmanship for 2-Years from date of manufacture.
Manufacturer shall have been manufacturing HID ballasts for at least ten years.
All HID ballasts shall be UL component recognized.
Ballast must be Howard Lighting Products (or
approved equal).
Capacitors & Starters for HID Capacitors:
All capacitors provided shall have a self­contained internal bleeder resistor where required according to UL1029.
All oil-filled capacitors shall be housed in aluminum or corrosion-resistant steel cans and contain.25” quick disconnect terminals.
• Oil lled capacitors shall have a 90°C max. Case
temperature rating.
• Dry lm acitors shall have a 100°C max. case
temperature rating cap.
*Ballast operates without a capacitor. Therefore a capacitor is not included with the standard kit.
Metal Halide
Pulse Start Metal Halide
shall be designed in accordance with all
Howard-Lighting.com | 800.956.3456 | Fax 601.422.1652
New Kit Model # Core and Coil Model
MP-350-4T-PSCWA-K M0350-71C-6XX
MP-400-4T-PSCWA-K M0400-71C-6XX
MP-750-4T-PSCWA-K M0750-71C-6XX
MP-1000-4T-PSCWA-K M1000-71C-6XX
MP-50-2T-HXH-K M0050-23C-1XX
MP-70-4T-HXH-K M0070-71C-5XX
MP-100-4T-HXH-K M0100-71C-5XX
MP-150-4T-HXH-K M0150-71C-5XX
MP-250-4T-PSCWA-K M0250-71C-6XX
MP-320-4T-PSCWA-K M0320-71C-6XX
MP-350-4T-PSCWA-K M0350-71C-6XX
MP-400-4T-PSCWA-K M0400-71C-6XX
MP-750-4T-PSCWA-K M0750-71C-6XX
MP-1000-4T-PSCWA-K M1000-71C-6XX
High Pressure Sodium
S-35-120-RXN-K* S0035-02C-111-K
S-35-120-RXH-K S0035-02C-111
Starters:
All starters will be epoxy-filled with a plastic external housing or aluminum external housing.
All starters shall be designed to provide six months of open circuit operation without failure.
All starters shall have a case rating temperature of 105°C.
All starters shall be designed to withstand 10,000
hours of continuous pulsing.
All starters shall have no exposed live parts.
HID Kits:
All HID kits shall be precision wound to insure proper insulation.
HID core and coil shall be interchangeable with prior ballast or include mounting bracket to adapt ballast to intended fixture.
All HID kits shall be supplied with pre-insulated input voltage leads.
There are to be no exposed live parts on the core & coil, starter, or dry capacitor.
Must meet all ANSI Specifications for the specified lamp.
Kit must include installation instructions and 1-800# for field assistance.
Ballast must be Howard Lighting Product (or approved equal).
New Kit Model # Core and Coil Model
S-50-120-RXN-K* S0050-02C-111-K
S-50-120-RXH-K S0050-02C-111
S-70-120-RXN-K* S0070-02C-111-K
S-70-120-RXH-K S0070-02C-111
S-70-4T-HXH-K S0070-71C-5XX
S-100-120-RXN-K* S0100-02C-111-K
S-100-120-RXH-K S0100-02C-111
S-100-4T-HXH-K S0100-71C-5XX
S-150-120-RXN-K* S0150-02C-111-K
S-150-120-RXH-K S0150-02C-111
S-150-4T-HXN-K S0150-71C-5XX
S-250-4T-CWA-K S0250-71C-2XX
S-250-5T-CWA-K S0250-81C-2XX
S-400-4T-CWA-K S0400-71C-2XX
S-400-5T-CWA-K S0400-81C-2XX
S-1000-4T-CWA-K S1000-71C-2XX
S-1000-5T-CWA-K S1000-81C-2XX
Energy Policy
Metal Halide Legislation
(EISA) Energy Independence & Security Act of 2007
Implementation Date: January 1, 2009
Products Affected: All metal halide fixtures (indoor or outdoor) from 150 to 500 watts. Products not
compliant can no longer be manufactured after December 31, 2008.
Inventory: Replacement lamps and ballast for probe start (standard metal halide) will remain available and are not affected by the legislation. Remaining probe start fixture inventory may be sold after January 1, 2009, provided it was manufactured prior to January 1, 2009.
Purpose/Intent: Shift the US to energy independence and utilization of higher efciency lighting products.
Luminaire Exemptions:
Standards do not apply to fixtures that:
• Use electronic ballast rated for 480 volts
• Use regulated lag ballast
• Fixtures that meet all of the following criteria
(within a single fixture):
1. Contain a ballast rated to operate at an ambient air temperature above 50˚ C as specified by UL 1029-2001
2. Rated for wet location use as defined by National Electrical Code 2002 Section 410.4(A)
3. Are only rated for 150W lamps
EISA Minimum Ballast Efficiency:
Ballast Type
Magnetic Probe Start 94%
Magnetic or Electronic
Pulse Start
Electronic
(non-Pulse Start)
E
Compliant Efficiency Calculation (examples):
Fixture Wattage Minimum Efficiency
250 Watt Probe Start 94% 250/.94 = 266
250 Watt Pulse Start 88% 250/.88 = 284
250 Watt Electronic
Pulse Start
Minimum Ballast Efficiency Rating
88%
90% 92%
Input Watt Calculation
(maximum fixture input watts)
90% 250/.90 = 278
Fixture Wattage
150W - 250W
251W - 500W
Federal Trade Commission (FTC) Label Identification:
• Circle E logo is required on ballast contained in
the fixture, product packaging, all advertising and marketing materials (merchandising, catalogs, website content, point of purchase, etc.)*.
• Affected products (150W - 500W) manufactured on
or after January 1, 2009, require the identification mark.
Probe
Start
(watts)
150 M107/E Medium 8500 150 M102/E Medium 10000
175 M57/E
250 M58/E Mogul 17000 250
400 M59/E Mogul 23500 400
ANSI
Lamp
Size
Medium
Mogul
Mean
Lumens
9300 175
Pulse
Start
Watts
M152/E M137/E
200 M136/E Mogul 13500
M153/E M138/E M154/E
320
M132/E
350 M131/E Mogul 27000
M155/E M135/E
ANSI
Lamp
Size
Mogul 12800
Mogul 19000
Mogul 21000
Mogul 31000
Mean
Lumens
Benefits of Pulse Start Metal Halide vs Probe Start :
• Faster restrike time (3-4 minutes)
• Half the warm up time (2 minutes)
• 25% to 50% improved lumen output (efcacy)
• Improved illumination levels over life
(better lumen maintenance)
• Colder starting temperatures
Contact your local Howard Lighting District Manager or Agent to receive:
• Howard Lighting product information
• Product specication details
• Other energy saving lighting products from
Howard Lighting
• Energy audit information
Electronic
Ballasts
Fluorescent Ballasts
Compact
Ballasts
HID
Howard-Lighting.com | 800.956.3456 | Fax 601.422.1652
45
HigH inTensiTy DisCHarge (HiD) ballasTs
Metal Halide Ballasts
Wir.
Input
Voltage
175 WATT, ANSI Code M-57, CWA Kit Model#: M-175-4T-CWA-K, M175-5T-CWA-K
120V
Ballasts
Electronic
Compact
208V 240V 277V
120V 208V 240V 277V
120V 208V 240V 277V
120V 208V 240V 277V 480V
120V 208V
Fluorescent Ballasts
240V 277V 480V
Model
Number
M0175-71C-214
M0175-71C-215
M0175-71C-216
M0175-81C-213
M0175-81C-214
Input
Power
(Watts)
210 210 210 210
210 210 210 210
215 215 215 215
202 202 202 202 202
220 220 220 220 220
Max. Input
Current
2.20
1.30
1.10
1.00
3.00
1.15
1.00
0.90
1.80
1.10
0.90
0.90
2.20
1.30
1.10
0.90
0.50
2.40
1.40
1.20
1.00
0.60
Nom.
Open Cir.
Volt.
305 C 1 2.42 4.00 10.0/400 7.00 - C/A
300 C 1 2.4 3.8 10.0/400 7.00 - C/A
320 C 1 2.4 3.8 10.0/400 7.00 - C/A
295 C 1 2.50 4.10 10.0/400 8.00 - C/A
303 C 1 2.42 4.0 10.0/400 6.90 - C/A
Dia.
pgs.
56-60
Dim.
Fig pg.
61
A
(in.)B(in.)
Capacitor pg. 52-54
Total
Wt.
(lbs.)
Ignitor
Part
Number
Pri/Sec
Conductor
C-Copper
A-Alum
U.L.
Bench
Top Rise
Code
D D D D
B C C C
B C C B
D D D D D
D D D D D
HID
Ballasts
250 WATT, ANSI Code M-58, CWA KIT Model#: M-250-4T-CWA-K, M-250-5T-CWA-K
120V 208V 240V 277V
120V 208V 240V 277V
120V 208V 240V 277V 480V
120V 208V 240V 277V 480V
M0250-71C-214
M0250-71C-216
M0250-81C-215
M0250-81C-216
295 295 295 295
290 290 290 290
295 295 295 295 295
280 280 280 280 280
3.502.0
1.80
1.50
2.50
1.40
1.30
1.10
3.90
2.40
2.00
1.80
1.00
2.70
1.60
1.40
1.20
0.70
305 C 2 1.6 3.5 15.0/400 8.40 - C/A
305 C 2 1.5 3.3 15.0/400 8.30 - C/A
310 C 2 1.90 3.80 15.0/400 10.00 - C/A
308 C 2 1.65 3.6 15.0/400 9.00 - C/A
A A A A
A A A A
A A A A A
A A A A A
46
46
Howard-Lighting.com | 800.956.3456 | Fax 601.422.1652
Loading...