Howard Industries HIB Series Specifications

Page 1
Highbay Fluorescent
Specification Sheet
5/29/2013
HIB Series
Highbay Fluorescent ­2, 4, 6, 8 or 10 Lamps
T8 or T5 I-Bay
Occupancy sensor is inside the fixture, not coming out of the ends.
Applications
Warehouse Manufacturing
Facility
Features
• Heavy Duty pre-painted steel construction
• Easy access to wiring compartment & ballast
• Access plate provides access to electrical wiring without the
need to open the fixture
• Factory installed lamp option available
• Choice of 86% Standard Specular Aluminum Reflec-tor (A),
95% Specular Enhanced Aluminum Reflector (E) or 91% White Reflector (W) (See our detailed reflector option table)
• Choice of standard or high efficiency designs
• Choice of 10% uplight or no uplight
• Factory Installed Integral Occupancy Sensor option - Occ
Sensor is inside the fixture and does not extend from the end of the fixture
• Factory Installed Emergency ballast option*
• Factory Installed Toggle Switch*
• Factory Installed Wireguard option
• Custom configurations available
• Can be easily mounted by a single person
• Suspended mounting insures a quick painless install
• Chain and V-Clip Hanging option
• Wire cable hanging option
• Special wiring available upon request
• Multiple supply cord options Cords/Cord sets are connected
to access plate
• UL Listed for Damp Locations
*Not available in all configurations - Consult Factory before ordering.
Cafeteria Auditorium Gymnasium
Project:
Catalog#:
Description
HIB series high-bay fluorescent fixture is a great energy saving alternative to traditional HID high-bay fixtures. This fixture operates two to ten lamps and has a low profile design. HIB has multiple reflector options for your application.
Benefits
• Energy Savings Compared to HID systems
• Exceptional Color Rendering
• High System Efficiency
• Long Lamp Life
• Instant On/Re-strike Capability
• Quality Lamp Holders
• Computer Designed Reflectors
• System Tested, Designed, Approved, and
Manufactured by Howard Industries in Mendenhall Mississippi.
• Compliant with Safety and performance standards.
2.43”
DIM A
Dimension A
(Width in inches)
2 Lamps* 8.90”
4 Lamps 13.25”
6 Lamps 16.30”
8 Lamps* 24.10”
10 Lamps* 24.10”
Reector (multiple options)
Low Prole Design
Access Plate
Easy Access Ballast Compartment
48”
Available with surface mount occupancy sensor
Holes for “v-clip” or wire-cable hanging kit
Specifications subject to change without notice.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Page 2
Highbay Fluorescent
Specification Sheet
5/29/2013
HIB Series
Highbay Fluorescent ­2, 4, 6, 8 or 10 Lamps
T8 or T5 I-Bay
Project:
Catalog#:
Ordering Information
Model Family
HIB HE 4 54 A PS MV 00H 07 0 I
Distribution/Reflector
(see tables 1-5, p3)
H: Highbay
HIB
F: Highbay high eff.
U: Highbay 10% uplight
T: Highbay 10% uplight high eff.
W: Wide Distribution high eff.
Y: Wide Distribution 10% uplight high eff.
A: Specular Aluminum (86%)
E: Enhanced Specular Aluminum (95%)
W: White reflective (91%)
No. of Lamps
2
4
6
8
(1)
10
Lamp Type/
Wattage
T8 Lamps
28: F28T8 32: F32T8
T5 Lamps
54: F54T5HO 49: F54T5HO/ES
CRI/CCT Ballast Input Volts Factory Installed
CRI CCT
A: No Lamps
B:
75
C:
75
D:
75
E:
75
F:
85
G:
85
H:
85
I:
85
J:
85
K:
85
L:
85
M:
85
N:
85
3000 3500 4100 5000 3000 3500 4100 5000 6500 3000 3500 4100 5000
High
Lumen
Yes Yes Yes Yes
High Efficiency (CEE Listed)
T8 T5
HE: High Ballast Factor SE: Standard Ballast Factor LE: Low Ballast Factor
X
P8: Program Rapid Start
X X
T5 Program Rapid Start
X
PS: PRS T5
X
X
X
X
X
X
X
X
X X X X X
MV: 120-277v
HV: 347-480v (T5HO)
(2)
AX: 480-277 Stepdown Autotransformer
(3)
Options
000: None
Integral Occ. Sensor
L: Lowbay (20ft MH) H: Highbay (40ft MH)
B: Emergency Ballast
G: Wireguard
I: Special wiring
T: Toggle switch bi­level lighting control
Cordset Options
00: Standard Disconnect 01: 6’ SJT 18/3, no plug
(4)
02: 10’ SJT 18/3, no plug 03: 6’ SJT 18/3 L5-15, twist lock 120v 04: 10’ SJT 18/3 L5-15twist lock 120v 05: 6’ SJT 18/3 5-15non twist lock 120v
(5)
06: 10’ SJT 18/3 5-15non twist lock 120v 07: 6’ SJT 18/3 L7-15 twist lock 277v 08: 10’ SJT 18/3 L7-15 twist lock 277v 11: 16/3, no plug specify length 17: 18/3, no plug specify length 22: 6’ SJT 16/3 L7-20 twist lock 277v 23: 6’ SJT 18/3 L6-15 twist lock 240v
(6)
*Other cordsets available, consult customer service
TBA Pack.
TBA
I: Single B: Bulk
Sample Ordering Number: HIB HA 4 54 A PS MV 00H 07 I
HIB Series Highbay Fluorescent Highbay Enhanced Aluminum Reflector 4-lamps (none installed) F54T5HO Program Rapid Start Ballast Multi-volt (120-277v) Factory Installed Highbay Occupancy Sensor 6’ SJT 18/3 L7-15 twist lock 277v Cordset Single Packaging
Specifications subject to change without notice.
SE Standard Ballast Factor High Efficiency Instant Start T8 Ballast
HE High Ballast Factor High Efficiency Instant Start T8 Ballast
LE Low Ballast Factor High Efficiency Instant Start T8 Ballast
PS Program Rapid Start T5 Ballast
P8 Program Rapid Start High Efficiency T8 Ballast
Distribution Explanation
H: Highbay
F: Highbay High efficiency
U: Highbay 10% uplight
T: Highbay High efficiency 10% uplight
W: Wide Dist. High efficiency
Y: Wide Dist. High efficiency 10% uplight
Ballast Descriptions
HIB-WG Wireguard
HF-WCH Wire Cable Hanging Kit
HF 2CV 2’ hanging chain & V-clips
HF 3CV 3’ hanging chain & V-clips
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Field Installed Options
1. 10 Lamp Configuration available in HEMV, P8MV, or PSMV only.
2. T8 Programmed Rapid Start recommended only in the case of frequent switching (as with an occupancy sensor). Instant Start T8 is appropriate for most ordinary applications.
3. Allows hook-up of standard MV ballast to 480V, may not fit with all ballast options. Available with 2, 4, and 6-lamp fixtures only.
4. Occupancy Sensors should only be used with programmed rapid start ballasts.Standard Occupancy Sensor requires neutral wired fixtures (ex. - 120v or 277v). For phase-to-phase voltage applications (240v) advise Customer Service at time of request.
5. 500 Lumen ballast is standard for T8. 120 or 277v input only. Advise Customer Service at time of quote for higher lumen rated ballast. Not available in all configurations - Consult Factory before ordering.
6. Allows for separate control of two ballasts through simple “toggling” of a standard wall switch. Recommend use of programmed rapid start ballast with this control. 120 or 277v control only; default wired for 277v; specify 120v wiring at time of order if applicable. Not available in all configurations - Consult Factory before ordering.
Page 3
Highbay Fluorescent
Specification Sheet
5/29/2013
Table 1: Fixture Efficiency
2 LAMP
Dist
Highbay
Highbay High eff.
Highbay
10% uplight
Highbay High eff.
10% uplight
Wide Dist.
High eff.
Wide Dist.
High eff.
10% uplight
Type A E W
H
F
U
T
W
Y
T8 NA NA NA
T5 NA NA NA
T8 86 91 84
T5 88 93 87
T8 NA NA NA
T5 NA NA NA
T8 88 93 88
T5 90 95 89
T8 78 86 83
T5 81 88 85
T8 82 89 86
T5 84 91 88
Standard Reflector Option
Table 2: Fixture Efficiency
Dist
Highbay
Highbay High eff.
Highbay
10% uplight
Highbay High eff.
10% uplight
Wide Dist.
High eff.
Wide Dist.
High eff.
10% uplight
Type A E W
H
F
U
T
W
Y
T8 85 90 85
T5 86 91 85
T8 86 91 85
T5 89 94 88
T8 88 93 89
T5 90 94 91
T8 88 93 88
T5 91 95 91
T8 80 87 85
T5 84 91 88
T8 84 89 87
T5 86 92 89
Standard Reflector Option
HIB Series
4 LAMP
Project:
Table 3: Fixture Efficiency
Catalog#:
Dist
Highbay
Highbay
High eff.
Highbay
10% uplight
Highbay
High eff.
10% uplight
Wide Dist.
High eff.
Wide Dist.
High eff.
10% uplight
Type A E W
T8 82 88 83
H
U
W
T5 86 92 88
T8 84 89 83
F
T5 88 93 87
T8 86 90 87
T5 89 93 90
T
T8 87 91 87
T5 91 95 90
T8 79 85 83
T5 83 89 87
Y
T8 83 88 86
T5 87 92 90
Standard Reflector Option
6 LAMP
Table 4: Fixture Efficiency
8 LAMP
Dist
Highbay
Highbay
High eff.
Highbay
10% uplight
Highbay High eff.
10% uplight
Wide Dist.
High eff.
Wide Dist.
High eff.
10% uplight
Type A E W
H
F
U
T
W
Y
T8 83 88 84
T5 86 92 88
T8 84 90 84
T5 89 94 88
T8 86 90 87
T5 89 93 91
T8 88 92 87
T5 91 95 91
T8 80 86 94
T5 84 90 88
T8 84 89 87
T5 87 92 90
Standard Reflector Option
Energy Cost Estimator
Hours
burned
per year
Cost per
kWh$
Energy Cost
Estimation
4368
0.12
Table 5: Fixture Efficiency
Dist
Highbay
Highbay High eff.
Highbay
10% uplight
Highbay High eff.
10% uplight
Wide Dist.
High eff.
Wide Dist.
High eff.
10% uplight
Type A E W
H
F
U
T
W
Y
T8 78 84 81
T5 84 90 87
T8 80 86 80
T5 87 92 86
T8 82 87 84
T5 87 92 89
T8 84 88 84
T5 89 94 89
T8 77 83 80
T5 83 89 86
T8 81 85 84
T5 86 90 88
Standard Reflector Option
Existing System New System
HIBE454APS
400W MH Highbay
Program Start T5 Ballast
Fluorescent Highbay
Number
of Fixtures
Watts per
Fixture
(existing
system)
Energy
used per year (existing
system)
Energy saving per
year (per fixture)
458
$240
1
Number of
Fixtures
Watts per
Fixture
(new
system)
Energy
used per
year (new
system)
$117.00
10 LAMP
1
234
$123
$250
$200
$150
$100
$50
$0
Field Installed Options
HIB WG
Wireguard
HF-2CV (2 foot) HF-3CV (3 foot)
Hanging Chain & V-clips
HF-WCH
Wire Cable Hanging Kit
(2 pcs per kit)
49% Annual Savings
$240 $123
Existing System New System
Specifications subject to change without notice.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Page 4
Highbay Fluorescent
Specification Sheet
5/29/2013
HIB Series
Photometric Data - 4 Lamp T5 (HIB FE 454A PSMV)
Highbay High Efficiency Distribution Enhanced Specular Aluminum Reflector
Candela Polar Plot Zonal Lumen Summary
Project:
Catalog#:
Zone Lumens %Lamp %Fix
0-20 2594.04 13.00 13.80
0-30 5533.53 27.70 29.40
0-40 8838.57 44.20 47.00
0-60 14797.6 74.00 78.70
0-80 18353.38 91.80 97.60
0-90 18811.97 94.10 100.00
10-90 18159.7 90.80 96.50
20-40 6244.53 31.20 33.20
20-50 9458.07 47.30 50.30
40-70 8102.19 40.50 43.10
60-80 3555.78 17.80 18.90
70-80 1412.61 7.10 7.50
80-90 458.60 2.30 2.40
0-180 18811.97 94.10 100.00
Luminance Data (cd/Sq.m)
Test Report: HIB-FE-454 2012-01-24.IES
Spacing Criteria (0-180): 1.28 Spacing Criteria (90-270): 1.16 Spacing Criteria (Diagnonal): 1.32
Maximum Candela =7206.2
Located At Horizontal Angle = 90, Vertical Angle = 15 # 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (15) (Through Max. Cd.)
Fixture Efficiency:
94.1%
Angle In Degrees
Average
0-deg
45 15148 12277 11052
55 14574 10292 10163
65 13788 9199 9888
75 11634 8877 9930
85 7727 4540 3692
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 112 112 112 112 109 109 109 109 105 105 105 100 100 100 96 96 96 94
1 102 98 93 90 100 95 92 88 91 88 86 88 85 83 84 82 80 78
2 93 85 79 73 90 83 77 72 80 75 71 77 73 69 74 71 68 65
3 85 75 67 61 83 73 66 61 71 65 60 68 63 58 66 61 57 55
4 78 67 58 52 76 65 58 52 63 56 51 61 55 50 59 54 50 48
5 72 60 51 45 70 59 51 45 57 50 44 55 49 44 53 48 43 41
6 66 54 46 40 65 53 45 39 51 44 39 50 43 39 48 43 38 36
7 62 49 41 35 60 48 40 35 47 40 35 45 39 34 44 38 34 32
8 57 45 37 31 56 44 37 31 43 36 31 42 35 31 41 35 31 29
9 54 41 34 28 52 41 33 28 40 33 28 39 32 28 38 32 28 26
10 50 38 31 26 49 38 30 26 37 30 26 36 30 25 35 29 25 24
Specifications subject to change without notice.
Average
45-deg
Average
90-deg
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Page 5
Highbay Fluorescent
Specification Sheet
5/29/2013
HIB Series
Photometric Data - 4 Lamp T5 (HIB TE 454A PSMV)
Highbay High Efficiency 10% Uplight Distribution Enhanced Specular Aluminum Reflector
Candela Polar Plot Zonal Lumen Summary
Project:
Catalog#:
Zone Lumens %Lamp %Fixt
0-20 2446.16 12.20 12.80
0-30 5147.81 25.70 27.00
0-40 8136.9 40.70 42.70
0-60 13544.67 67.70 71.10
0-80 16900.6 84.50 88.70
0-90 17337.3 86.70 91.00
10-90 16712.67 83.60 87.70
20-40 5690.75 28.50 29.90
20-50 8588.5 42.90 45.10
40-70 7415.15 37.10 38.90
60-80 3355.93 16.80 17.60
70-80 1348.54 6.70 7.10
80-90 436.70 2.20 2.30
90-110 118.95 0.60 0.60
90-120 245.11 1.20 1.30
90-130 467.96 2.30 2.50
90-150 1122.7 5.60 5.90
90-180 1710.07 8.60 9.00
110-180 1591.12 8.00 8.40
0-180 19047.37 95.20 100.00
Luminance Data (cd/Sq.m)
Test Report: HIB-TE-454 2012-01-24.IES
Spacing Criteria (0-180): 1.26 Spacing Criteria (90-270): 1.10 Spacing Criteria (Diagnonal): 1.26
Maximum Candela =6704.41
Located At Horizontal Angle = 90, Vertical Angle = 15 # 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (15) (Through Max. Cd.)
Fixture Efficiency:
95.2%
Angle In Degrees
Average
0-deg
45 14401 10723 10067
55 13533 9236 9574
65 12406 8851 9769
75 10071 8705 9815
85 6473 4536 3598
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 111 111 111 111 108 108 108 108 101 101 101 95 95 95 89 89 89 87
1 101 97 93 89 98 94 90 87 88 85 83 83 81 79 78 76 75 72
2 92 85 78 73 89 82 76 71 77 72 68 73 69 65 69 66 63 60
3 84 74 67 61 81 72 65 59 68 62 57 64 59 55 61 57 53 51
4 77 66 58 52 74 64 57 51 61 54 49 58 52 48 55 50 46 44
5 71 59 51 45 69 58 50 44 55 48 43 52 46 41 49 44 40 38
6 66 53 45 39 63 52 44 39 49 43 38 47 41 37 45 40 36 33
7 61 48 40 35 59 47 40 34 45 38 33 43 37 33 41 36 32 30
8 57 44 36 31 55 43 36 31 41 35 30 40 34 29 38 33 29 27
9 53 41 33 28 51 40 33 28 38 32 27 37 31 26 35 30 26 24
10 50 38 30 25 48 37 30 25 35 29 25 34 28 24 33 27 24 22
Specifications subject to change without notice.
Average
45-deg
Average
90-deg
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Page 6
Highbay Fluorescent
Specification Sheet
5/29/2013
HIB Series
Photometric Data - 4 Lamp T5 (HIB YW 454A PSMV)
Wide High Efficiency 10% Uplight Distribution White Reflector
Candela Polar Plot Zonal Lumen Summary
Project:
Catalog#:
Zone Lumens %Lamp %Fixt
0-20 1650.3 8.30 9.20
0-30 3592.31 18.00 20.10
0-40 6073.94 30.40 34.00
0-60 11589.75 57.90 64.80
0-80 15741.35 78.70 88.00
0-90 16332.6 81.70 91.30
10-90 15916.2 79.60 89.00
20-40 4423.64 22.10 24.70
20-50 7179.52 35.90 40.20
40-70 7949.78 39.70 44.50
60-80 4151.6 20.80 23.20
70-80 1717.63 8.60 9.60
80-90 591.25 3.00 3.30
90-110 208.20 1.00 1.20
90-120 333.15 1.70 1.90
90-130 517.73 2.60 2.90
90-150 1046.12 5.20 5.90
90-180 1549.02 7.70 8.70
110-180 1340.82 6.70 7.50
0-180 17881.62 89.40 100.00
Luminance Data (cd/Sq.m)
Test Report: HIB-YW-454 2012-01-24.IES
Spacing Criteria (0-180): 1.32 Spacing Criteria (90-270): 1.54 Spacing Criteria (Diagnonal): 1.56
Maximum Candela =4502.23
Located At Horizontal Angle = 90, Vertical Angle = 15 # 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (15) (Through Max. Cd.)
Fixture Efficiency:
89.4%
Angle In Degrees
Average
0-deg
45 9906 11232 12171
55 9853 11531 12922
65 9252 11921 13403
75 8889 11921 12531
85 8492 6264 5453
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 105 105 105 105 101 101 101 101 95 95 95 89 89 89 84 84 84 82
1 94 89 85 81 91 86 83 79 81 78 75 76 74 71 72 70 68 65
2 85 77 70 64 82 74 68 63 70 65 60 66 61 58 62 58 55 53
3 77 66 59 52 74 64 57 51 61 54 49 57 52 48 54 49 46 43
4 70 58 50 44 67 57 49 43 53 47 41 50 45 40 47 43 39 36
5 64 52 43 37 61 50 42 36 47 40 35 45 39 34 42 37 33 31
6 59 46 38 32 56 45 37 31 42 36 30 40 34 30 38 33 29 27
7 54 42 33 28 52 41 33 27 38 32 27 36 30 26 35 29 25 23
8 50 38 30 25 48 37 29 24 35 28 24 33 27 23 32 26 22 21
9 47 35 27 22 45 34 27 22 32 26 21 31 25 21 29 24 20 18
10 44 32 25 20 42 31 24 19 30 23 19 28 23 19 27 22 18 16
Specifications subject to change without notice.
Average
45-deg
Average
90-deg
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Loading...