Howard Industries FSR8 Series Specifications

Page 1
Specification Sheet
2/22/2015
8’ Fluorescent Strip Channel
Retrofit Kit
FSR8 Series
Project:
Catalog#:
Approved by:
Fluorescent Retrofit
Reflector and
lamps sold separately!
Applications
Multiple configurations allow you to select a lamp type and number to meet your criteria, whether they be:
Improved Light Energy Savings
Utility Rebates Improved reliability
Up to 32%
Energy Reduction
with same light!
Description
FSR8 series fluorescent strip channel retrofit kit is a simple and cost-effective solution to upgrading existing 8’ strip fixtures into newer and more efficient electronic T8 or T5 strips.
Features
Construction
• Designed for trouble free installation.
• Uses two (2) 4’ gear trays that install independently for easy
installation.
• Lampholder cutouts guarantee correct lampholder spacing and that lampholder will not fall out during install.
• Optional reflectors available
• Code gauge steel
• High gloss, baked enamel finish
• High quality lamp holders
• NEC compliant luminaire power disconnect standard
• Contents: 2 geartrays with fully wired ballast and
• lampholders; 12 tek screws; 4 geartray tethers
Ballast
• Electronic, Inherent Thermal Protection, Class P, Sound rated A
• UL Listed
Fixture Listing: UL Listed Quality Assurance
• System Tested, Designed, Approved, and Manufactured in Mendenhall, Mississippi.
Lamp Type
Watts 156 96 108 148 120 218 148
Raw lamp lumens 11812 11800 11800 11800 9400 13932 11800
Ballast factor 80% 77% 87% 114% 100% 95% 114%
Effective Lamp Lu-mens (BF * raw lumens)
Lumens per Watt 61 95 95 91 78 61 91
Lumens rela-tive to base case (%)
Energy Savings NA 38% 31% 5% 23% NA 32%
Existing Fixture 2x 75W T12 Base Case
9450 9086 10266 13452 9400 13235 13452
NA 96% 109% 142% 99% NA 102%
4x 32W T8 Low Ballast Factor
High Lumen Lamps
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
4x 32W T8 Standard Ballast Factor High Lumen Lamps
www.HowardLightingProducts.com
4x 32W T8 High Ballast Factor High Lumen Lamps
2 x 54W T5HO
Existing Fixture 2x 110W T12HO
Base Case
4x 32W T8 High Ballast
Factor High Lumen
Lamps
Page 2
Specification Sheet
FSR8 Series
8’ Fluorescent Strip Channel
Retrofit Kit
Project:
Catalog#:
Approved by:
Ordering Information
Model Family
Fixture Length
Width
No. of Lamps
Lamp Type/
Wattage
(1)
Ballast
(see Table 1)
Input Volts Factory Installed Options Cordset Options
Fluorescent Retrofit
FSR 8 4 4 32A HE MV 000 00 0 I
FSR 8: Eight Foot 4: 4.25”
5: 5” O: Other
(Specify Width)
Table1:
SE Standard Ballast Factor High Efficiency Instant Start T8 Ballast
HE High Ballast Factor High Efficiency Instant Start T8 Ballast
LE Low Ballast Factor High Efficiency Instant Start T8 Ballast
PS Program Rapid Start T5 Ballast
P8 Program Rapid Start High Efficiency T8 Ballast
2 4
Installation in Seven Simple Steps
1. Power off
2. Remove existing front cover, lampholders, and socket bars.
3. Screw geartray tethers into existing fixture to hang geartray.
4. Insert lampholders into labeled geartray cutouts.
5. Insert incoming power leads into ballast disconnect plug.
6. Close cover and screw it to fixture body.
7. Insert lamps.
32A: F32T8
28A:F28T5 54A: F54T5HO
Lampholders
SE: SBF High Eff HE: HBF High Eff LE: LBF High Eff
PS: PRS T5 P8: PRS T8
Geartray tethers
Reflector
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
(2)
(2)
(2)
Existing fixture
Geartray
www.HowardLightingProducts.com
MV: 120-277v
(2)
HV: 347-480v (T5HO) AX: 480-277v
Lampholders
Reflector Retainer Screw
000: No FIOs 00: Standard Disconnect I: Single
(3)
(1) Lamps not included. Please use “PS” Ballast Ordering Options for T5 lamp type. (2) High Efficiency ballasts are CEE Listed. (3) Step-down autotransformer. Allows hook-up of standard MV ballast to 480v.
Sample Ordering Number: FSR 8 4 2 32A HE MV 000 00 0 I
FSR8 Fluorescent Strip Retrofit Kit 8-foot 4.25” Wide Cover 4-lamps (none installed) F32T8 High Ballast Factor High Efficiency Ballast Multi-volt (120-277v) No Factory Installed Options No Cordset Single Packaging
RAPID SHIP MODELS AVAILABLE FOR NEXT DAY SHIPMENT
•FSR84232ASEMV000000I
•FSR84432ASEMV000000I
•FSR84432AHEMV000000I
•FSR84432ALEMV000000I
•FSR84432ASEMV000000I
•FSR84454APSMV000000I
•FSR85432ASEMV000000I
T
Pack. B A
Page 3
Specification Sheet
2/22/2015
FSR8 Series
Project:
Field Installed Options Ordering
FSR8-E Enhanced Specular Aluminum Reflector (95% reflectance)
Fluorescent Retrofit
FSR8-A Specular Aluminum Reflector (86% reflectance) FSR8-W White Aluminum Reflector (91% reflectance)
Catalog#:
Approved by:
Energy Cost Estimator
Existing System New System
FSR84432AHE
2x 110W T12HO
Hours
burned
per year
Cost per
kWh$
4368
0.12
Energy Cost
Estimation
Howard Industries provides this tool to examine the potential impact of lighting decisions. This tool provides an ESTIMATE only. The analysis of this tool does not warrant or guarantee the actual costs or savings that will be realized as the analysis suggested. You can find the full version of this cost saving tool at the Howard Lighting Website—www.howardlightingproducts.com. Click “Cost of Ownership Calculator”.
Copyright (c) 2008 Howard Industries All Rights Reserved.
Number
of Fixtures
Watts per
Fixture
(existing
system)
Energy
used per year (existing
system)
Energy saving per
year (per fixture)
1
244
$128
High Ballast Factor
Fluorescent Strip Retrofit
Number of
Fixtures
Watts per
Fixture
(new
system)
Energy
used per
year (new
system)
1
154
$81
$47.00
$140
$112
$84
$56
$28
$0
37% Annual Savings
$128 $81
Existing System New System
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Page 4
Specification Sheet
2/22/2015
FSR8 Series
Project:
Photometric Data - 4 Lamp T8 (FSR84432ASE)
Iso-Footcandle Plot
Fluorescent Retrofit
8’ Mounting Height, 4-lamp Multi-volt ballast Lamps: Four 32w T8; no reflector
Zonal Lumen Summary
Catalog#:
Approved by:
Candela Plot
Zone Lumens %Lamp %Fix
0-30 1046 18.0 16.0
0-40 1780 30.0 27.0
0-60 3493 59.0 53.0
0-90 5496 93.0 84.0
90-120 1033 18.0 16.0
90-150 1064 18.0 16.0
90-180 1064 18.0 16.0
0-180 6560 111.0 100.0
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 128 128 128 128 123 123 123 123 114 114 114 105 105 105 97 97 97 91
1 113 106 100 95 108 102 97 92 94 90 85 87 83 80 73 73 73 74
2 101 90 81 74 96 87 79 72 80 73 67 73 68 63 57 57 57 61
3 91 78 68 60 87 75 65 58 69 61 55 63 57 51 46 46 46 51
4 83 68 57 49 79 65 56 48 60 52 45 56 49 43 38 38 38 44
5 76 60 49 42 72 58 48 40 54 45 38 49 42 36 32 32 32 38
6 70 54 43 36 66 52 42 35 48 39 33 44 37 31 28 28 28 34
7 64 48 38 31 61 47 37 30 43 35 29 40 33 27 24 24 24 30
8 60 44 34 27 57 42 33 27 39 31 25 37 29 24 21 21 21 27
9 56 40 31 24 53 39 30 24 36 28 23 34 27 22 19 19 19 24
10 52 37 28 22 50 36 27 21 33 26 20 31 24 19 17 17 17 22
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Page 5
Specification Sheet
2/22/2015
FSR8 Series
Project:
Retrofit Details
Fluorescent Retrofit
Catalog#:
Approved by:
Back View Front View
No reflector With Optional Reflector
Note: The representational drawings show only one (1) four (4) foot section of the FSR8 series. The FSR8 will have two (2) four foot sections that are shipped together. The two four foot (and optional reflectors) will need to be field assembled.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
Loading...