INSTALLATION INSTRUCTIONS
Doc#1025-000244-000 RV0
Model number parameter list
1
Where C represents CCT variations.
-40° to +40°C
-40° to 104°F
Warning:
To avoid electric shock:
Be certain electrical power is OFF before and
during installation and maintenance.
Luminaire must be connected to a wiring system
with an equipment-grounding conductor.
Warning:
To avoid the risk of fire, explosion, or electric shock, this
product should be installed, inspected, and maintained by a
qualified electrician only, in accordance with all applicable
electrical codes.
Warning:
Make sure the supply voltage is the same as the
rated luminaire voltage.
Not suitable for hazardous location use.
Do not operate in ambient temperatures above
those indicated on the luminaire nameplate.
Keep lens tightly closed when in operation.
For supply connections use wire rated for at least 90°C (194°F)
Mounting Details (inches):
![](/html/a8/a8c5/a8c54511c53c9878b17d3ffe7ac5215603c020d46a499a7f74ad3d98aad7b1b2/bg2.png)
INSTALLATION INSTRUCTIONS
Installation Steps
1. Release arm-door screw (1 screw) to gain access to wiring compartment and pole-side nuts/bolts.
2. Mount arm to pole with supplied hardware. Ensure that it is tight, secure, and gasket is in place. (requires Metric #14
wrench)
3. Attach luminaire to the arm using supplied hardware. Transfer fixture wire inside the wiring compartment.
4. Ensure power is off, and then make electrical connections. Connect wires; white wire to “Neutral”, black wire to “Line”,
green wire to “Ground”.
5. Check that the lighting fixture is firmly installed and wired correctly.
6. Close the arm-door.
7. Finally, turn on power and verify function.
Mounting on round poles:
Use XAL-RPA accessory to mount this fixture on round poles, up to 5” diameter (sold separately)
Additional Product Images# 1025-000230-050 RV00