Howard XALE-C150-HV Series, XALE-C300-MV Series, XALE-C230-HV Series, XALE-C100-HV Series, XALE-C230-MV Series Installation Instructions Manual

...
INSTALLATION INSTRUCTIONS
XALE Series
04/12/2018
Model number parameter list
1
Where C represents CCT variations.
Model1
Input Voltage
Input Power
(W)
Power Factor
Input
Current
Weight
(lbs)
Ambient rating
XALE-C100-MV Series
100 – 277VAC
50/60 Hz
100W
>0.9
1.5A
19.5
-40° to +40°C
-40° to 104°F
XALE-C150-MV Series
150W
1.8A
19.5
XALE-C230-MV Series
230W
2.5A
23
XALE-C300-MV Series
300W
3.5A
29.5
XALE-C100-HV Series
277 – 480VAC
50/60 Hz
100W
0.55A
19.5
XALE-C150-HV Series
150W
0.88A
19.5
XALE-C230-HV Series
230W
1.4A
23
XALE-C300-HV Series
300W
1.8A
29.5
Warning:
To avoid electric shock:
Be certain electrical power is OFF before and
during installation and maintenance.
Luminaire must be connected to a wiring system
with an equipment-grounding conductor.
Warning:
To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes.
Warning:
Make sure the supply voltage is the same as the
rated luminaire voltage.
Not suitable for hazardous location use. Do not operate in ambient temperatures above
those indicated on the luminaire nameplate.
Keep lens tightly closed when in operation.
For supply connections use wire rated for at least 90°C (194°F)
Mounting Details (inches):
Mount Arm
Mounting hole guide
Pole-side nuts/bolts
Arm-door screw
Fixture-side bolts
INSTALLATION INSTRUCTIONS
XALE Series
04/12/2018
Installation Steps
1. Release arm-door screw (1 screw) to gain access to wiring compartment and pole-side nuts/bolts.
2. Mount arm to pole with supplied hardware. Ensure that it is tight, secure, and gasket is in place. (requires Metric #14
wrench)
3. Attach luminaire to the arm using supplied hardware. Transfer fixture wire inside the wiring compartment.
4. Ensure power is off, and then make electrical connections. Connect wires; white wire to “Neutral”, black wire to “Line”,
green wire to “Ground”.
5. Check that the lighting fixture is firmly installed and wired correctly.
6. Close the arm-door.
7. Finally, turn on power and verify function.
Mounting on round poles:
Use XAL-RPA accessory to mount this fixture on round poles, up to 5” diameter (sold separately)
Additional Product Images# 1025-000230-050 RV00
100W, 150W Luminaire
230W Luminaire
300W Luminaire
Loading...