PW15AH/...
Single point load cell
Dimensions (in mm;
1 mm= 0.03937 inches)
M6
M6
12
Load direction
Center of Platform
Special features
− Hermetically sealed
(IP68; IP69K)
− Highest reliability
− Reduced minimum load cell
verification interval (v
multi range applications
− Interchangeable to products of
many manufacturers
− Stainless steel
− 6-wire-technology
− Integrated connection for
protective cable conduit systems
min
) for
Optional:
− different cable lengths
Connection cable
(see page 3)
Data Sheet
40"0.15
19.1
M6
25"0.3
M6
12
Plug (see page 3)
19"0,1
12
M6x0.5
(only 1x)
150"0.2
100"0.2
75"0.2
M6
55"5
19"0.1
17.5
6
12
Mounting:
Cylindrical head screw M6-10.9
Tightening torque: 14 N⋅m
Specifications
Type
Accuracy class
1)
PW15AH...
C3MR
Max. number of load cell interv. (nLC) 3000
Maximum capacity (E
Min. LC verific. interval (v
Temperature effect on zero balance
(TK
)
0
) kg 10 20 50 100
max
), g 1 2 5 10
min
% of
C
/
n
10 K
"0.0140
"0.0140
Maximum platform size mm 500 x 400
Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKC)
Temperature range:
+20 ... +40°C [+68 ... +104°F]
−10 ... +20°C [+14 ... +68°F]
Hysteresis error (dhy)
Non-linearity (d
2)
2)
)
lin
Minimum dead load output return (DR)
Off center load error
Input resistance (RLC)
Output resistance (R0)
Reference excit. voltage (U
) 5
ref
Nom. range of excit. volt. (BU)
Max. excitation voltage
Insulation resist. (Ris) with 100 V
DC
2)
% of
C
/
n
10 K
n
Ω
V
GΩ > 1
2.0 "0.2
0 "0.1
"0.0175
"0.0117
"0.0166
"0.0166
"0.0166
"0.0233
380 "15
350 "10
1 ... 12
15
3)
Nominal temp. range (BT) −10 ... +40 [+14 ... +104°F]
Service temp. range (Btu)
Storage temp. range (Btl)
Safe load limit (EL) *
)
°C [°F]
% of
E
max
−10 ... +50 [+14 ... +122°F]
−25 ... +70 [−13 ... +158°F]
150
*) at max. eccentricity mm 160
Lateral load limit (Elq), static
Breaking load (Ed)
Deflect. at E
max
(s
), app. mm < 0.5
nom
E
max
300
300
Weight (G), approx. kg 1.0
Protection class acc. to EN60529 (IEC529)
Material: Measuring element
Coating
Cable sheath
1)
According to OIML R60 with PLC = 0.7
2)
The data for Non-linearity (d
meets the requirements according to OIML R60.
3)
According to OIML R76
4)
Following the definitions of the DIN 40050, part of 9, for road vehicles
), Hysteresis error (dhy) and Temperature effect on sensitivity (TKC) are typical values. The sum of these data
lin
IP 68 (test conditions 100 h at 1 m water column);
IP69K (water at high pressure, steam jet cleaning)
Stainless steel
Silicone rubber
PVC
"0.0140
"0.0140
4)