Hottinger Baldwin Messtechnik FIT4 User Manual

FITR/4...
Digital load cells for dynamical weighing
Special features
4 limit switches with
hysteresis
Dosing functionalities and diag-
nostic channel (Type E)
Fast triggering and scaling of the
measured value
Trigger function (external or
level trigger)
PC-Software for parameter ad-
justment and dynamical analysis
Integrated overload protection
Test report for 3000 d accord. to
OIML R 60, R 76
Data Sheet
Electrical connection
Cable 8 x 0.25 mm2, 3 m (6 m, 12 m) long, 7 0.5 mm
Venting tube
Cable 1 Cable 2 (extended version E)
RS-485 RS-232 CANOpen/DeviceNet
1)
brown
1)
yellow grey RB CanL in grey OUT 4 black TB CanL out black OUT 3 green RA RxD CanH in green OUT 2 blue TA TxD CanH out blue OUT 1 white GND1 GND1 GND 1 white GND 2 red +UB 1 +UB 1 +UB 1 red UB 2
1)
The standard version (S) does not have a diagnostic channel. Brown is not assigned, yellow is trigger input.
Diag. Rb/Tb Diag. Rb/Tb Diag. /Rb/Tb brown IN 2 Diag. Ra/Ta or Trigger Diag. or Trigger Diag. Ra/Ta or Trigger yellow IN 1
The FIT/... digital load cells are available in different versions, e.g.:
Max. capacity: 5, 10, 20, 50, 75 kg
Cable length: 1 = 3 m, 2 = 6 m, 3 = 12 m
Accuracy class: 3 = C3
Interfaces: A = RS-232, B = RS-485, C = CANOpen, D = DeviceNet Version: S = Standard, E = Extended
Housing: 4 = stainless steel
Designation: FIT
HBM
2
1- FIT/ 4 E B 3 1/ 10 KG
HBM has defined so-called preferred variants. All other variants are available on request.
Preferred variants of the standard types
Housing Interface
RS-232 RS-485 (4 wire) CANOpen DeviceNet
FIT/0 1-FIT/0SA30/5KG
1-FIT/0SA30/10KG 1-FIT/0SA30/20KG 1-FIT/0SA30/50KG 1-FIT/0SA30/75KG
FIT/1 1-FIT/1SA31/5KG
1-FIT/1SA31/10KG 1-FIT/1SA31/20KG 1-FIT/1SA31/50KG 1-FIT/1SA31/75KG
FIT/4 1-FIT/4SB32/5KG
FIT/5 1-FIT/5SA30/5KG
1-FIT/5SA30/10KG 1-FIT/1SA30/20KG
1-FIT/0SB30/5KG 1-FIT/0SB30/10KG 1-FIT/0SB30/20KG 1-FIT/0SB30/50KG 1-FIT/0SB30/75KG
1-FIT/1SB31/5KG 1-FIT/1SB31/10KG 1-FIT/1SB31/20KG 1-FIT/1SB31/50KG 1-FIT/1SB31/75KG
1-FIT/1SB32/5KG 1-FIT/1SB32/10KG 1-FIT/1SB32/20KG
1-FIT/4SB32/10KG 1-FIT/4SB32/20KG
1-FIT/4SB31/5KG 1-FIT/4SB31/10KG
1-FIT/0SC30/5KG
1-FIT/0SC30/10KG
1-FIT/1SC31/5KG
1-FIT/1SC31/10KG
1-FIT/5SC30/5KG
1-FIT/5SC30/10KG
1-FIT/0SD30/5KG
1-FIT/0SD30/10KG
1-FIT/1SD31/5KG
1-FIT/1SD31/10KG
Preferred variants of the extended types
In addition to the standard version (S), another extended version (E) with control functions (two connecters) is available. All versions offers additional application areas with limit values and dosing control functions (e.g. sorting systems, filling systems).
Housing Interface
RS-232 RS-485 (4 wire) CANOpen DeviceNet
FIT/0 1-FIT/0EA30/5KG
1-FIT/0EA30/10KG 1-FIT/0EA30/20KG 1-FIT/0EA30/50KG 1-FIT/0EA30/75KG
FIT/1 1-FIT/1EA31/5KG
1-FIT/1EA31/10KG 1-FIT/1EA31/20KG 1-FIT/1EA31/50KG 1-FIT/1EA31/75KG
FIT/4 1-FIT/4EB31/5KG
FIT/5 1-FIT/5EA30/5KG
1-FIT/5EA30/10KG
= for these load cell types separate data sheets are available
1-FIT/0EB30/5KG 1-FIT/0EB30/10KG 1-FIT/0EB30/20KG 1-FIT/0EB30/50KG 1-FIT/0EB30/75KG
1-FIT/1EB31/5KG 1-FIT/1EB31/10KG 1-FIT/1EB31/20KG 1-FIT/1EB31/50KG 1-FIT/1EB31/75KG
1-FIT/4EB31/10KG
1-FIT/4EB32/5KG 1-FIT/4EB32/10KG
1-FIT/5EB30/5KG 1-FIT/5EB30/10KG
1-FIT/0EC30/5KG
1-FIT/0EC30/10KG
1-FIT/1EC31/5KG
1-FIT/1EC31/10KG
1-FIT/4EC31/5KG 1-FIT/4EC31/10KG 1-FIT/4EC31/50KG
1-FIT/5EC30/5KG 1-FIT/5EC30/10KG
1-FIT/0ED30/5KG
1-FIT/0ED30/10KG
1-FIT/1ED31/5KG
1-FIT/1ED31/10KG
1-FIT/4ED31/5KG
1-FIT/4ED31/10KG
1-FIT/5ED30/5KG
1-FIT/5ED30/10KG
B1714-2.0 en