Hottinger Baldwin Messtechnik C2A User Manual

C2A...
Load cell
Max. capacities: 1t ... 10t
Special features
Load cell and mounting aids made from stainless steel
Low profile
Complies with OIML R60 re-
Six-wire circuit
Available Option:
-- Ex-schutz EEx ib IIC T4
-- Ex-schutz EEx d IIC T6
Dimensions (in mm; 1mm=0.03937 inches)
C2A /1..10t, pendle bearing ZPS and pendle support EPO3R C2A /1..10t, elastomer bearing ZELB and pendle
EP03R/5t
4x at circumference
ZPS25/66
C2A_/1--10t
1.5
Nominal load A B R Pendle
1t, 2t 48 10 30, 50 ZPS25/66 130 ± 5 1; 1.5 ZELB/2t 100 9 120 60 10 103 ± 4.5 400
5t 48 8 60 ZPS25/66 130 ± 5 1.7 ZELB/5t 125 11 150 100 10 11 0 ± 8 620
10t 53 8 80 ZPS25/66 135 ± 5 2.2 ZELB/10t 175 13 200 100 12 124 ± 9.5 810
FR: Restoring force for 1mm sidewards displacement S
bearing
max.:
turned by
o
30
degree, 3xM4 at circumferen ce
H S
max
(mm)
Max. sidewards displacement at load nominal
F
R
(%o.load)
support EPO3R
Elastomer
bearing
Elastomer bearing
EP03R/5t
C2A_/1--10t
L M N O P Q S
max
(mm)
F
(N)
R
Data sheet D 21.C2A.0e
Technical Data
Typ e C2AD1 C2AC3
Accuracy class to OIML R60 D1 C3
Max. number of load cell intervalls (nLC) 1000 3000
Rated capacity (E
Min. load cell verification interval (v
) t 1, 2, 5, 10
max
) %ofC
min
n
0.0286 0.0100
Sensitivity (Cn) mV/V 2
Tolerance on sensitivity % <±0.1000 <±0.0500
Temperature effect on sensitivity (TKC)
1)
%ofCn/10K <±0.0500 <±0.0080
Temperature effect on zero signal (TK0) %ofCn/10K < ±0.0400 < ±0.0140
Hysteresis)
Non-linearity (d
1)
)1)
lin
% < ±0.0500 < ±0.0180
% < ±0.0500 < ±0.0170
Creep (dDR)in30min % < ±0.0500 < ±0.0167
Input resistance (RLC) (black-blue) 350...450
Output resistance (R0)(red-white) 356±1.5 356±0.12
Reference excitation volt. (U
) V 5
ref
Nom. range of excitation volt. (BU) V 0.5...12
Isolation Resistance (Ris) G >5
Nominal temperature range (BT)
Service temperature range (Btu)
Storage temperature range (Btl)
Save load limit (EL) %ofC
Breaking load (Ed) %of C
Side load limit (Elq) %ofC
Permissible dynamic load (F
(Vibration amplitude to DIN 50100)
Deflection at max. capacity, (s
approx. (± 15%)
srel
nom
)
)
oC[o
F] -- 10...+40 [+15...105]
oC[o
F] --30...+70 [--20...+160]
oC[o
F] --50...+85 [ --60...+185]
150
300
50
100
2)
%ofC
n
n
n
n
mm 0.15; 0.15; 0.17; 0.2
Weight (G), approx. kg 1.7; 1.8; 1.8; 1.8
Protection class (IP) to EN 60529 (IEC529) IP 67 (Test conditions:100h at 1m water column)
Materials
Measuring body Cable gland Cable sheath
1)
The temperature coefficient of sensitivity, the hysteresis and the non-linearity are matched to comply with OIML R60 accuracy requirements
Rust resistant
Nickel plated brass
Silicone
for the respective scale devision.
2)
70% at C2A../10t-type.
Wiring code
(gray) Sensing lead
(black) Excitation voltage (--)
(white) Signal (+)
(blue) Excitation voltage (+)
(green) Sensing lead
(red) Signal (--) (yellow) Cable screen on housing ground
Accessories (not included in scope of supply): ZPS Pendle bearing EPO3R Pendle support - upper part
and ZELB Elastomer bearing.
Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45, D--64293 Darmstadt, Germany Tel.: +49 (0)6151 / 803 0; Fax: +49 (0)6151 / 803 9 100 www.hbm.com; e--mail: support@hbm.com
Modifications reserved. All details describe our products in general form. They are not to be understood as express warranty and do not constitute any liability whatsoever.
wt 03.01 -- (pdf)