![](/html/9e/9e21/9e21d8e6d1b7317422e5717f53685ff2b32580b1a9269c8b203182ad2c26babf/bg1.png)
AD101B
Digital transducer
electronics
Data Sheet
AD101B Amplifier PCB
Functional diagram
Special features
− DC Amplifier PCB for Strain gage
transducers
− For static and dynamic
applications
− Direct computer connection via
RS-232 interface
− Test certificate for 6000 digits
class III available
− High transmission rate and
resolution
− Memory for users settings
Strain gage
transducer
AD101B
Calibration
Measuring mode
Zero
A
D
EEPROM
Linearization
Serial-Number
Digital filter
Measuring rate
Sensitivity
Zero setting
mP
Digital I/O
5...10 V
External voltage stabilization
Computer
RS-232
1200 ... 38400 baud
![](/html/9e/9e21/9e21d8e6d1b7317422e5717f53685ff2b32580b1a9269c8b203182ad2c26babf/bg2.png)
Specifications
(Full bridge)
Transducer connection
Type AD101B
Accuracy class 0.015
Number of trade values, acc. to EN 455501 (R76)
(with internal calibration)
Input sensitivity µV/e 1
Measuring range
Input signal range
Measuring signal resolution, max. bit 20 (at 1 Hz)
Measuring rate (depending on output format and baud rate) Hz 600 ... 4.7
Cut-off frequency of the digital filter (−3 dB), adjustable Hz 40 ... 0.25
Bridge excitation voltage U
(Excitation from supply voltage)
Measuring signal input, Strain gage transducers
B
d 6000
± 2.0
± 3.0
V
DC
Ω ≥40...4000
5 ... 10 (= supply voltage!)
1)
Input resistance (differential)
Transducer cable length m ≤ 100, in case of calibration incl. cable
Interface cable length RS-232 m ≤ 15 (25 pol. female connector)
Calibration signal mV/V 2± 0.01 %
Temperature stability of the calibration signal ppm/°C
Linearity error (related to full scale) % ±0.01
Temperature effect on
zero point (related to full scale)
measuring sensitivity (related to actual value)
Interface RS-232
Baud rate, adjustable bit/s 1200 ... 38400
Supply voltage V
Current consumption (without load cell) mA ≤ 80
Temperature range:
Nominal temperature
Service temperature
Storage temperature
Dimensions mm 93 x 53 x 17
Weight, approx. g 40
Degree of protection according to EN 60529 (IEC 529) IP00
1)
Depending on the external supply voltage
MΩ
%/10K
DC
°C [°F]
typ. ± 0.005; max. 0.01
typ. ± 0.005; max. 0.01
residual ripple ≤10 mV (p.p.)
−10...+40[+14...+104]
>15
v2.5
5 ... 10
−20...+60[−4...+140]
−25...+85[−13...185]
Accessories, to be ordered separately
Basic devices AED9101C, AED9201B (see separate Data Sheets) offering:
− EMC protection
− Degree of protection IP65
− Supply voltage range 6...30 V
− Additional interfaces
− Electrically isolated in- and outputs
Documentation
− 1-FIT-AED-DOC (CD-ROM with operating manual and AED_Panel32 panel program
Hottinger Baldwin Messtechnik GmbH.
Modifications reserved. All details describe our products in
general form only. They are not to be understood as express
warranty and do not constitute any liability whatsoever.
Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45 ⋅ 64293 Darmstadt ⋅ Germany
Tel. +49 6151 803-0 ⋅ Fax: +49 6151 803-9100
Email: info@hbm.com ⋅ www.hbm.com
B0946-4.1 en