Hotpoint WL24AHP, WL36AHP, WL36HP, WL24HP Service Information

Indesit Company UK Ltd
© 2012 Reg. Office: Peterborough PE2 9JB Registered in London: 106725
Service Information
HOTPOINT
LUCE
WINE CELLARS
WL24HP 76770 WL36HP 76769
Energy Band A Models WL24AHP 78417 WL36AHP 78416
5407680 Issue 1 Dec. 2012
SM003423 ~ C00290011
2 of 15
Service Manual UK
Indesit
Company
English
Health & Safety Information Applicable to Servicing Refrigeration Products Containing R134a
General
1. This manual is not intended as a comprehensive repair/maintenance guide to the appliance.
2. It should only be used by suitably qualified persons having technical competence, applicable product knowledge, suitable tools and test equipment.
3. Servicing of electrical appliances must be undertaken with the appliance disconnected. (unplugged from the electrical supply).
4. Servicing must be preceded by earth continuity and insulation checks.
5. Personal safety precautions must be taken to protect against accidents caused by sharp edges on metal and plastic parts.
6. After servicing, the appliance must be rechecked for electrical safety.
Refrigerant R134a - Safe Handling - Transporting & Storage
1. Work areas should be well ventilated and any immediate heat sources turned off.
2. Do not smoke where there is a possibility of refrigerant in the atmosphere. Customer/s should also be advised.
3. Cylinders must not have heat applied, or stand close to a heat source, and should be stored out of direct sunlight.
4. Should a sudden release of refrigerant occur, open windows or outside doors in the immediate vicinity, then evacuate for a few minutes.
5. It is illegal to intentionally vent R134a refrigerant to atmosphere. Follow the company procedure on collection and reclamation.
6. If a leak is identified the appliance must be repaired immediately if possible.
7. Where it is not possible to repair the appliance immediately the customer should be advised: Appliance should be turned off and the refrigerant recovered.
8. Returned compressors must be sealed to prevent the escape of oil and refrigerant. Refer to the Environmental responsibilities for service engineers in your Health and Safety booklet.
9. Cylinders (R134a) being transported must be in an upright position on the floor of the vehicle and prevented from movement.
10. A green compressed gas label Part No. C00247959 (8100062) should be displayed on the rear of the vehicle.
INDEX
Health & Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4
Dimensional Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Description / Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Introduction & Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Ideal Wine Temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Stocking the Wine Bottles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Dismantling Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 - 11
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 - 13
Wiring Connection Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3 of 15
Indesit Company
Service Manual UK English
SPECIFICATIONS (A Band Models Overleaf)
Introduction Dates WL24HP - December 2011
WL36HP - August 2012
Commercial Code WL24HP - 76770 WL36HP - 76769
Colour Grey / Stainless Grey / Stainless
Dimensions See the page 5
Country of Origin Italy Italy
Weight (kg)
Gross 36.0 kg 39.5 kg Net 30.5 kg 35.0 kg
Capacities - Litres
Gross 67 litres 101 litres Net 66 litres 99 litres
Conservation Period 0.3 hours 0.3 hours
Noise Level - dB 45 dB 45 dB
Climate Class N/ST (16°C to 38°C) N/ST (16°C to 38°C)
Operating Voltage 220/240 V 220/240 V
Frequency 50 Hz 50 Hz
Energy Consumption - 2011 Regulations
kWh/year 306.0 270 kWh/24 Hours 0.84 0.74 Energy Band E D
Absorbed Power (W) 100 Watts 100 Watts
Internal Temperature 0°C to +18°C 0°C to +18°C (Electronically controlled) Set by the user Set by the user
Compressor (:) Danfoss Danfoss
Type TL35G TL35G Run TBC TBC Start TBC TBC
Capacitor Fitted to Compressor (where applicable).
Refrigerant R134a (Grams) 45 gram 50 gram
Doors - Reversible No No
4 of 15
Service Manual UK
Indesit
Company
English
SPECIFICATIONS - A BAND MODELS
Introduction Dates WL24AHP - October 2012
WL36AHP - October 2012
Commercial Code WL24AHP - 78417 WL36AHP - 78416
Colour Grey / Stainless Grey / Stainless
Dimensions See the following page
Country of Origin Italy Italy
Weight (kg)
Gross 36.0 kg 58.0 kg Net 30.5 kg 52.5 kg
Capacities - Litres
Gross 66 litres 101 litres Net 64 litres 99 litres
Noise Level - dB 33 dB 33 dB
Climate Class N/ST (16°C to 38°C) N/ST (16°C to 38°C)
Operating Voltage 220/240 V 220/240 V
Frequency 50 Hz 50 Hz
Energy Consumption - 2011 Regulations
kWh/year 329.0 328.5 kWh/24 Hours 0.90 0.90 Energy Band A A
Absorbed Power (W) 100 Watts 100 Watts
Internal Temperature 0°C to +18°C 0°C to +18°C (Electronically controlled) Set by the user Set by the user
Compressor (:) Danfoss Danfoss
Type DLX4KK.1 DLX4KK.1 Run TBC TBC Start TBC TBC
Capacitor 2uf 2uf
Refrigerant R134a (Grams) Refer to Rating Plate Refer to Rating Plate
Doors - Reversible No No
5 of 15
Indesit Company
Service Manual UK English
DIMENSIONAL DIAGRAMS
WL24HP
WL36HP
Where the wine cellar is to be installed as a built under appliance, it should be enclosed in a cabinet with a supported base that is raised from the floor.
Whether built-in or built-under it should always be installed in a well ventilated, non-humid cabinet away from any heat source.
Cabinetry Aperture Required WL24 WL36
Height 450 mm 681 mm
Width 560 mm 561 mm
Depth 550 mm 545 mm
Ventilation space: at least 50 mm
Dimensions of the compartment
Furniture side area
Dimensions of the cellar
550
Ventilation space: at least 50 mm
560
588
715
680
550
Furniture side area
560 min.
680 min.
560
min.
Dimensions of the compartment
Dimensions of the cellar