Hotpoint SXBD922FWDUK, SXBD925FWDUK User Manual

Indesit Company UK Ltd
© 2015 Reg. Office: Peterborough PE2 9JB Registered in London: 106725
Information
Interim Manual
for
Hotpoint
A+
Side by Side
Fridge Freezers
Models Comm. Covered Code
SXBD922FWDUK 84166 SXBD925FWDUK 84163
Introduced Sept. 2013
Note: Temporary Document to be replaced with a Service Manual when available.
5407884 Issue 1 July 2015
SM004197 ~ C00337512
2 of 17
Indesit
Company
HEALTH AND SAFETY
For the servicing of refrigeration products, containing Isobutane R600a refrigerant. These instructions are in addition to any other Company procedures already published.
Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for which these instructions are MANDATORY.
1. Only engineers who have been trained on the safe handling of Isobutane R600a refrigerant are authorised to transport, store or carry out system repairs.
2. This manual is not intended as a comprehensive repair/maintenance guide to the appliance.
3. Must only be used by suitably qualified persons having technical competence, applicable product knowledge, suitable tools and test equipment.
4. Servicing of electrical appliances must be undertaken with the appliance disconnected (unplugged from the electrical supply).
5. Servicing must be preceded by earth continuity and insulation checks, plus refrigerant leak detection.
6. Personal safety precautions must be taken to protect against accidents caused by sharp edges on metal and plastic parts.
7. After servicing, the appliance must be rechecked for electrical safety.
8. Smoking, naked flames, or operating gas and/or electrical equipment (including cordless power tools) are forbidden within the storage area, working area and vehicles used to transport Isobutane.
9. The carrying case for the scales and refrigerant must display a red flammability label Part Number C00247960 (8100063) that should be visible and readable at all times.
10. The vehicle and storage area must be ventilated as far as is reasonably practicable and the aluminium case kept out of direct sunlight. The storage temperature of Isobutane should not exceed 50°C.
11. Vehicles carrying R600a canisters: The Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations 2009 (CDG 2009) require every transport unit to be equipped with one portable fire extinguisher, Part Number C00274640, for inflammability classes 1 A, B and C, with a minimum capacity of 2 kg dry powder.
12. The vehicle transporting Isobutane (R600a) refrigerant must display a Red Flammable Gas warning sticker (Part No. C00247960 [(8100063)].
13. Engineers should not wear clothes that are liable to cause static discharge ('electrostatic sparking').
14. Avoid working in small rooms.
15. Do not work in cellars.
16. Whenever possible move the appliance into a larger open area away from possible ignition sources.
17. Request the customer to turn off all other electrical and gas appliances in the near vicinity of the repair and note that it is done. Customers should be advised to restrict activity within the near vicinity for a short time.
continued...
3 of 17
Indesit Company
HEALTH AND SAFETY
18. Isobutane refrigerant must be vented to atmosphere, (outside of the premises e.g. via open window through the clear plastic hose supplied).
19. Isobutane is heavier than air and must not be vented within 3 metres of the following: sewer cover, cellar, drain or any similar construction lower than ground level, boiler air inlet/outlet, or near any possible source of ignition.
20. Working with a naked flame i.e. soldering or brazing is forbidden. Unless otherwise stated, pipework connections must only be made using the Lokring coupling system.
21. Electronic leak detectors with high voltage tips must NOT be used with any Isobutane (R600a).
22. All equipment used for this activity must be checked regularly and maintained in a safe working condition; parts must be replaced as required.
Information Regarding Isobutane Canisters
1. The maximum quantity of Isobutane an engineer should hold or store at any one time is two 1kg net aluminium canisters, supplied individually as Part No. C00089700.
2. Canisters must be stored inside the aluminium case with the weighing scales for protection from possible damage and heat. The aluminium case must NEVER be placed next to a heat source or in direct sunlight.
3. Isobutane must only be dispensed to the appliance from the 1kg net aluminium canister placed in an upright position on the weighing scales provided.
4. All used canisters must be a returned as scrap and therefore, left out for the driver to collect and return for disposal.
5. Canisters must not be punctured or the internal valve damaged.
6. Before storing the canister it must have the extraction tap valve removed and the internal valve of the canister checked for leakage using leak detector [Part No. C00222861 (5700043)].
7. All used canisters and those found to be leaking should be exhausted to atmosphere to ensure they are emptied completely. Refer to the following paragraph.
8. Refit the extraction tap if necessary, open the tap and then invert the canister. This must be done outside in open air away from buildings and ignition sources and complying with Item 19 on this page.
4 of 17
Indesit Company
INDEX
Health & Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 3
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 7
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Function Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 12
Child Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Door Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Lamp and its Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Error Codes & Auto Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 - 17
INTRODUCTION
The models found in this manual were produced in China for the UK market and were first introduced in August 2013.
The appliances are 1760 mm high side by side fridge and freezer. They have one compressor and are fully frost free. with an A++ Energy Rating.
Doors are not reversing.
The digital display interface module is mounted in the front of the freezer door with the drinks dispenser, the fast freeze button and ice maker controls are also mounted in the same area.
The fridge and freezer temperature settings are adjusted by selecting the + / - buttons next to the relevant temperature display window. All functions are monitored and actioned by the power module mounted at the rear of the appliance within the compressor compartment.
The climate class is N / ST signifying that it is designed to operate in ambient temperatures between +16°C to +38°C.
As with many refrigeration appliances, it is important that it is installed and operated within the recommended ambient temperature range and that there is adequate ventilation.
All appliances equipped with an automatic ice-maker and water dispenser must be connected to a water supply that only delivers drinking water.
5 of 17
Indesit Company
PRODUCT SPECIFICATIONS
Coding parameters
Business Free Standing Family Side By Side
Series 1 Width 90 Full No-Frost Series 2 From 541 To 560Litres
Aesthetic Other Hotpoint User Interface CB_Electronic-Digit
Brand Hotpoint Trade Mark Hotpoint
Noise (dBA) 47 Mix Segment CB_Side by Side A+
Color Inox EAN 13 5016108841662
Range M.D.A.
General Information
Colour Leading Code
Markets GB-United Kingdom Special Features
Energy Label
Regulation 2011 Regulation Note
Energy Class A+ Energy Info Energy Efficiency Index 0.0
Autonomy (energy blackout)
7.0 Freezing capacity 10.0
Noise (dBA) 47 Climatic class N , SN , ST
EU 1998 or OTHER DEDICATED
Energy consumption in 24 h
0.0
Energy consumption per year
0.0
2011 - 2014 Regulation
Energy consumption in 24 h
1.17
Energy consumption per year
427
Category of the household refrigerating appliance model
7-Refrigerator Freezer
Technical Data
Supply Voltage 220-240 Supply Frequency 50
Absorbed Power (W) 130 Absorbed Current (A) 1.1
Plug Type United Kindom Cable Length (m) 1.8
Dimensions & Weights
Height PF (cm) 176.0 Width PF (cm) 90.2 Depth PF (cm) 75.0
Package Height (cm) 185.0 Package Width (cm) 96.3 Package Depth (cm) 77.8
Built-in hole Height (cm) 0.0 Built-in hole Width (cm) 0.0 Built-in hole Depth (cm) 0.0
No. Pieces per Package (Nr)
1 Gross Weight (Kg) 116.0 Net Weight (Kg) 106.0
Package Weight (Kg) 10.0
Volumes
Total gross capacity 545 Total net capacity 515
Fridge gross capacity 347 Fridge net capacity 340
Freezer gross capacity 198 Freezer net capacity 175
Volume lordo Multi-Use compartment lordo
0
Volume netto Multi-Use compartment netto
0
Coordinated Items
Set
Naming
Life Style
Aesthetics
Decor panel No
Cabinet colour SIMIL INOX Door colour Stainless Steel
6 of 17
Indesit Company
PRODUCT SPECIFICATIONS
Dashboard type Dashboard colour
Handle type External Handle colour Aluminium
Colore supporto maniglia Plinth Yes
Note Marketing Estetica Colore guarnizione porta
User Interface
User Interface Elettronica-Display
Display Digit Display Functions
No. of indicators 4 Indicator type
Child Lock , Holiday , Super Cool , Super Freeze
Special Functions/Accessories
Funzioni Accessori Speciali
Drink Dispenser ConFiltroDrink , Holiday , Ice Maker , Super Cool , Super Freeze
Notes Function Special Accessories
Integrated Ever Fresh No Smell-absorbing filters Yes
Fridge Special Accessories Freezer Special Accessories
Open door acoustic signal Yes Special Plus
Nr. Bottles 0,75 l 0
General characteristics
Cooling system No-Frost N. Compressors 1
Independent regulation Yes Electronic control Yes
Doors Reversibility No (Blocked Doors) Automatic door closing No
Condenser Skin Rollers 4
Feet 2 Gas in the cooling circuit R600
Temperature
Design temp. of fridge Fresh-food:+5°C Design temp. of freezer Four-star:-18°C
Design temp. of other comp. Connettività
Fridge Compartment
Fridge cooling system No Frost Multiflow Yes
Hidden evaporator Yes F ridge defrosting system Automatic
Chiller
No. of shelves 3 Fridge shelf type Glass
No. of grid profiles 0 No. of bottle holders
Bottle/Can holder Meat box
No. of salad crispers 2 Salad crisper colour Transparent
Salad crisper cover type Glass With White Profile Salad crisper moisture control
Internal Light Light LED Surround
Internal Thermometer
Multi-Use compartment
Numero Stelle Temperatura Massima Temperatura Minima
Inner Door
Total No. of levels 5
Level 1
Transparent Top Shelf With Cover
Level 2
Maxi Transparent Bottle Shelf
Level 3
Maxi Transparent Bottle Shelf
Level 4 Transparent Bottle Shelf
Level 5 Bottle Shelf
Tot nr levels SX 0
Level 1 SX
Level 2 SX
Level 3 SX
Level 4 SX
Level 5 SX
Suspended shelf
No. of egg holders 1 Egg holder colour Transparent
No. of butter boxes 0 Butter box colour
Bottle trap No
Can Holder
Accessori Maxi Bottiglie Note Accessori
Freezer Compartment
Freezer cooling system No Frost Total No. of compartments 5
Freezer Level 1 Glass With White Profile
Freezer Level 2 Glass With White Profile
Freezer Level 3 Glass With White Profile
Loading...