3
GB
DATA P LATE
Dimensions
width cm 37.5
heigh t cm 32
depth cm 41.5
Vol ume lt. 50
Ele ctr ic al
connections
volt age: 230 -240V ~ 50Hz
maximum p ower absorbed
2800W-3000W
ENE RGY LAB EL
Directive 2002/40/EC on the label
of electri c ovens.
Stand ard EN 50 304
Energy consumption f or Natural
convec ti on – heatin g mode:
Convection mode.
Decl ared energy consumpti on for
For ced co nvection Clas s – heat ing
mode: Baking.
This appliance conforms to the
following European Econ omic
Community directives:
- 20 06/95/EEC of 12/12/06 (Low
Volt age) and subsequent
amendments;
- 20 04/108/ EEC of 15/12/04
(El ec tromagn etic C ompatib ility) an d
subsequent amendment s;
- 93 /68/EEC of 2 2/07/93 and
subsequent amendment s.
- 20 02/96/EC and subsequent
amendments.
Electrical Connection
Electrical connection
The electrical connection to the mains must be made
on the appliance. The power voltage and frequency
are as indicated on the rating plate.
!
THIS APPLIANCE MUST BE EARTHED.THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
• Using a screwdriver, press on the tabs situated on
each side of the terminal board cover.
• Pull open the terminal board cover.
To connect the power supply cable, proceed as
follows:
••
••
• Unscrew the cable clamp screw and the contact
screws L-N-6.
• Fasten the wires beneath the screwheads using the
following colour scheme: Blue (N) Brown (L)
Yellow-Green
6
• Fasten the power supply cable in the
corresponding cable clamp and close the cover.
Electrical Connection:
Voltage Frequency: 230
V-1+N 50Hz
Fuse Section: 16A
Supply cable: 3x1.5mm
2
You can connect your oven to the system means of a
terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of its
recess in the event of maintenance operations (only
use HAR - H 05 - RRF quality cables fitted with a plug
conforming to the regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly dangerous.
! After connecting the appliance to the flexible
cable, tighten all the screws on the terminal board.
42
NL