Hotpoint NVLR333EE Dimension Manual

®
NVLR333EE – Hotpoint 5.8 Cu. Ft. Extra-Large Capacity Electric Dryer
Dryer Dimensions (in inches)
Exhaust Options:
4-way via rear, right, left and bottom.
Circuit Requirements:
An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
Electric Dr yer Rating:
240V, 5600W, 60Hz, 24 Amp 208V, 4400W, 60Hz, 22 Amp
Installation Information : For complete information, see installation instructions packed with product for current dimensional data.
* 24-1/2” from the edge of the side panel to the front.
25-1/2” from front to edge of end caps.
Specification Revised 2/05
470142
Listed by Underwriters Laboratories
36
25-1/2
42
54-1/2
Side View
27
Rear View
36
42
27
2
3-1/2
2-1/2
25-1/2*
Side View
Rear View
5-1/4
25-3/4
23-1/2
11-1/2
R
®
®
Dryer exhausting information
For complete information see installation instructions packed with dryer.
Important note: GE Kit Number 14-A018 needed when conver ting rear exhaust to bottom or side. (On Extra-large (5.7) capacity models only.)
Ducting materials For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended duct length. The following kit or parts are available from your local service organization. Kit WX8X75 – 7' aluminum duct and 4' hood, short tail. (OR individual parts):
WX8X65 7' aluminum flex duct only WX8X58 4' clamps (2) WX8X67 4' exhaust hood See installation instructions for complete information.
Exhaust length calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum lengths for flexible ducts are less than for rigid duct. See table in installation instructions. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening dampered wall cap.
NVLR333EE – Hotpoint 5.8 Cu. Ft. Extra-Large Capacity Electric Dryer
Dryer Exhausting Information – Use Metal Duct Only Vertical and Horizontal Ducting
Specification Revised 2/05
470142
Listed by Underwriters Laboratories
Special Installation Requirements Alcove or Closet Installation:
• If your dr yer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other sur faces are: 0" either side 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or other wise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces 0" both sides 3" rear
A
Best Per formance
Maximum Le ngth of 4" Dia.
Rigid Met al Duct
Maximum Le ngth of 4" Dia.
Flexible M etal Duct
Exhaus t Hood Type Exhaus t Hood Type
Domesti c Dryer M odels
Number
of
90°
Turns
A
4" OpeningB2-1/2"
Opening
A
4" OpeningB2-1/2"
Opening
7.0, 6.0 and 5. 8
Capacit y Models all Electr ic Dryers
0 1 2 3 4
90 ft . 60 ft . 45 ft . 35 ft . 25 ft.
127 ft. 117 ft. 107 ft.
97 ft . 87 ft .
75 ft. 65 ft . 55 ft . 45 ft . 35 ft.
52 ft . 42 ft. 32 ft . 22 ft . 12 ft.
7.0, 6.0 and 5. 8
Capacit y Models all Electr ic Dryers
0 1 2 3
90 ft . 60 ft . 45 ft . 35 ft.
60 ft . 45 ft . 35 ft. 25 ft.
55 ft . 40 ft . 30 ft . 20 ft .
45 ft . 30 ft . 20 ft . 15 ft.
7.0, 6.0 and 5. 8.0
Capacit y Models all Gas Dr yers
0 1 2 3
90 ft . 60 ft . 45 ft . 35 ft.
60 ft . 45 ft . 35 ft. 25 ft.
55 ft . 40 ft . 30 ft . 20 ft .
45 ft . 30 ft . 20 ft . 15 ft.
A
4
GE Dryer Vent
B
2-1/2
R