Hotpoint HSV05, HSV08, HSV12, HSV14, HSV07 Owner's Manual And Installation Instructions

...
HSV05
HSV07
HSV08
HSV10
HSV12
HSV14
HSV18
HSV24
Air Conditioners
Owner’s Manual and Installation Instructions
39-7388-1 12-99 JR
Safety Information
Safety Precautions . . . . . . . . . . . . . . . .3
How to Connect Electricity . . . . . . . .3
Use of Extension Cords . . . . . . . . . . .4
Use of Adapter Plugs . . . . . . . . . . . . .4
About the Controls . . . . . . . . . . . . .5, 6
Care and Cleaning
Grille and Case . . . . . . . . . . . . . . . . . . .7
Outdoor Coils . . . . . . . . . . . . . . . . . . .7
Air Filter . . . . . . . . . . . . . . . . . . . . . . . .7
Installation Instructions
Window Installation–5000 BTU
Model (HSV05) . . . . . . . . . . . .8, 9–12
Window Installation–7000, 8000, and 10,000 BTU Models (HSV07,
HSV08, and HSV10) . . . . . .8, 13–17
Window Installation–12,000, 14,000, 18,000 and 24,000 BTU Models (HSV12, HSV14, HSV18, and
HSV24) . . . . . . . . . . . . . . . . . .8, 18–23
Through the Wall Installation–Optional
All Models . . . . . . . . . . . . . . . . . . . . . .24
Troubleshooting Tips
Before You
Call For Service . . . . . . . . . . . . . . . . .25
Normal Operating Sounds . . . . . . .25
Customer Service
Product Registration . . . . . . .2, 29, 30
Warranty . . . . . . . . . . . . . . . . . . . . . . .31
Service Telephone
Numbers . . . . . . . . . . . .2, Back Cover
www.geappliances.com
E DB68-00954A(2)
Customer Service Troubleshooting Tips
Operating Instructions
Safety InstructionsInstallation Instructions
FOR YOUR RECORDS
Write the model and serial numbers here:
#
#
You can find them on a label on the side of the air conditioner.
Staple sales slip or cancelled check here.
Proof of the original purchase date is needed to obtain service under the warranty.
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
READ THIS MANUAL
IF YOU NEED SERVICE
You’ll find many answers to common problems in the
Before You Call For Service
section. If you
review our chart of
Troubleshooting Tips
first, you may not need to call for service at all.
If you do need service, you can relax knowing help is only a phone call away. A list of toll-free customer service numbers is included in the back section. Or, you can always call the GE Answer Center® at 800.626.2000, 24 hours a day, 7 days a week.
2
IMPORTANT!
Fill out the Consumer Product Registration Card.
Two easy ways to register your appliance!
Through the internet at www.geappliances.com
Complete and mail the enclosed Product Registration Card
GE & You, A Service Partnership.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Repair or replace immediately all electric
service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the mode control to
OFF
and unplug your air conditioner before making any repairs or cleaning.
NOTE:
We strongly recommend that any servicing be performed by a qualified individual.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
SAFETY PRECAUTIONS
3
Customer ServiceTroubleshooting Tips
Operating Instructions
Safety Instructions Installation Instructions
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions,
Electrical
Requirements
section for specific electrical
connection requirements.
HOW TO CONNECT ELECTRICITY
Customer Service Troubleshooting Tips
Operating Instructions
Safety InstructionsInstallation Instructions
4
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
USE OF EXTENSION CORDS –
115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter, where local codes permit, a
temporary connection
may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
If the adapter ground terminal breaks,
DO NOT
USE
the air conditioner until a proper ground
has been established.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
USE OF ADAPTER PLUGS –
115-Volt models only
Read and follow this Safety Information carefully.
SAVE THESE INSTRUCTIONS
Customer ServiceTroubleshooting Tips
Operating InstructionsSafety Instructions
Installation Instructions
About the controls on the air conditioner.
Features and appearance will vary.
Controls
Mode Controls
HIGH COOL, MED COOL
and
LOW COOL
provide
cooling with different fan speeds.
LOW FAN
or
HIGH FAN
provides air circulation
and filtering without cooling.
NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
Cooling Descriptions
For Normal Cooling
—Select
HIGH COOL
or
MED
COOL
with the temp control at midpoint.
For Maximum Cooling
—Select
HIGH COOL
with the temp control at the highest number available on your knob.
For Quieter & Nighttime Cooling
—Select
LOW COOL
with the temp control at midpoint.
Temp Controls
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
5
MODE CONTROLS
Your model will have one of the above type controls.
TEMP CONTROLS
Your model will have one of the above type controls.
OFF
LOW
FAN
LOW
COOL
HIGH
FAN
HIGH COOL
MED COOL
OFF
LOW
FAN
LOW COOL
HI
FAN
HI
COOL
LOW
COOL
LOW
FAN
OFF
MED COOL
4
3
2
HI
FAN
HI
COOL
5
1
6
7
8
9
10
45
3
2
1
34
6
7
8
2
1
5
6
6
Customer Service Troubleshooting Tips
Operating Instructions
Safety InstructionsInstallation InstructionsCustomer Service Troubleshooting Tips Installation Instructions Safety Instructions
Operating Instructions
Customer Service Troubleshooting Tips Installation Instructions Safety Instructions
Operating Instructions
About the controls on the air conditioner.
Additional controls and important information.
Vent Control
The vent control is located above the control knobs.
When set at
CLOSE
, only the air inside the room will
be circulated and conditioned. When set at
OPEN
,
some inside air is exhausted outside.
To open the vent, push the lever to the right. To close it, push it to the left.
Air Direction – Side-to-Side
On some models, the side-to-side air direction is adjusted by grasping and moving the inner vertical louvers to the desired position.
CIRCULAIRE (on some models)
For fixed side-to-side air direction, set the Circulaire switch to ONuntil the desired air direction is obtained, then move it to
OFF
.
For continuous side-to-side air circulation, set the Circulaire switch to ONand leave it there.
Energy Saver
(on some models)
The energy saver switch controls the fan.
ON
—The fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied.
OFF
— The fan runs all the time, while the
compressor cycles on and off.
This switch must be set at
OFF
in order to use the
fan settings (on the mode control).
Air Direction – Up and Down
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove (on some models):
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.
To remove (on some models):
Open the inlet grille upward by pulling out the bottom of the inlet grille.
Using the tab, pull up slightly on the filter to release it and pull it down.
2
1
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Customer ServiceTroubleshooting Tips
Operating InstructionsSafety Instructions
Installation Instructions
Care and cleaning of the air conditioner.
7
Grab the tab on the filter and pull it to the right.
8
Customer Service Troubleshooting Tips
Operating Instructions
Safety InstructionsInstallation InstructionsCustomer Service Troubleshooting Tips Installation Instructions Safety Instructions
Operating Instructions
Customer Service Troubleshooting Tips Installation Instructions Safety Instructions
Operating Instructions
Preparing to install the air conditioner–All models.
Read these instructions completely and carefully.
NOTE TO INSTALLER: Leave these instructions with
the air conditioner after installation is completed.
NOTE TO CONSUMER: Keep this Owner’s Manual and Installation Instructions for future use.
IMPORTANT NOTES:
For personal safety, this air conditioner must be properly grounded.
It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.
Follow National Electric Codes (NEC) and/or local codes and ordinances.
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
Before You Begin
Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Electrical Requirements
Parts Included
Type A (9)
Security bracket (3)
Top mounting rail
Right
accordion
panel
Foam top
window gasket
Window
sash seal
Left
accordion
panel
Type B (8)
Customer ServiceTroubleshooting Tips
Operating InstructionsSafety Instructions
Installation Instructions
9
Window Installation Instructions for 5000 BTU Units (model HSV05)
Phillips-head screwdriver
Adjustable wrench
Ruler or tape measure
Scissors or knife
Pencil
Level
Tools You Will Need
HSV05
air conditioner
Top mounting rail
seal strip
Storm Window Requirements
A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES—
WIDTH:
2
LENGTH:
Long enough to fit inside the window
frame.
THICKNESS:
To determine the thickness, place a
piece of wood on the stool to make it 1/2higher
than the top of the storm window frame.
Attach securely with nails or screws provided by the installer.
2
10
Customer Service Troubleshooting Tips
Operating Instructions
Safety InstructionsInstallation InstructionsCustomer Service Troubleshooting Tips Installation Instructions Safety Instructions
Operating Instructions
Customer Service Troubleshooting Tips Installation Instructions Safety Instructions
Operating Instructions
Window Installation Instructions for 5000 BTU Units (model HSV05)
Read completely, then follow step-by-step.
Window Requirements
These instructions are for a standard double-
hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without
the accordion panels if needed to fit in a narrow window. See the window opening dimensions below.
All supporting parts must be secured to firm
wood, masonry or metal.
The electrical outlet must be within reach of the
power cord.
1/2higher than frame
Storm window frame
Wood
Stool
1
12
7
8min.
22to 36
(With accordion panels)
17
13
16min.