The hood can look different to that illustrated in the drawings in this booklet. The instructions for use, maintenance and installation, however, remain the same.
! It is important to conserve this booklet for consultation at any moment. In
the case of sale, cession or move, make sure it is together with the product.
! Read the instructions carefully: there is important information about
installation, use and safety.
! Do not carry out electrical or mechanical variations on the product or on the
discharge conduits.
GENERAL SAFETY
The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 50cm from electric cookers and 65cm from gas or mixed cookers. If the instructions for installation for the gas hob specify a greater distance, this must be adhered to. Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only. WARNING! Do not connect the appliance to the mains until the installation is
fully complete. Before any cleaning or maintenance operation, disconnect hood from the mains by removing the plug or disconnecting the mains electrical supply. Always wear work gloves for all installation and maintenance operations. The appliance is not intended for use by children or persons with impaired physical, sensorial or mental faculties, or if lacking in experience or knowledge, unless they are under supervision or have been trained in the use of the appliance by a person responsible for their safety. This appliance is designed to be operated by adults, children should be monitored to ensure that they do not play with the appliance. This appliance is designed to be operated by adults. Children should not be allowed to tamper with the controls or play with the appliance. Never use the hood without effectively mounted grating! The hood must NEVER be used as a support surface unless specifically indicated. The premises where the appliance is installed must be sufficiently ventilated, when the kitchen hood is used together with other gas combustion devices or other fuels. The ducting system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose such as discharging exhaust fumes from appliances burning gas or other fuels. The flaming of foods beneath the hood itself is severely prohibited. The use of exposed flames is detrimental to the filters and may cause a fire risk, and must therefore be avoided in all circumstances. Any frying must be done with care in order to make sure that the oil does not overheat and ignite. Accessible parts may become hot when used with cooking appliances. With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the authorised authorities. The hood must be regularly cleaned on both the inside and outside (AT LEAST ONCE A MONTH). This must be completed in accordance with the maintenance instructions provided in this manual). Failure to follow the instructions provided in this user guide regarding the cleaning of the hood and filters will lead to the risk of fires. Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks. We will not accept any responsibility for any faults, damage or fires caused to the appliance as a result of the non-observance of the instructions included in this manual.
ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area. If it not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area apply a double pole switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over-current category III, in accordance with installation instructions. Warning! Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains cable is correctly assembled.
Replacing the power cable
The hood is provided with a special power cable ; if the cable is damaged, request a new one from Technical Service.
AIR VENT
(for the suction versions)
Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (connection flange). Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
! Use a duct of the minimum indispensible length. ! Use a duct with as few elbows as possible (maximum elbow angle: 90°). ! Avoid drastic changes in the duct cross-section. ! Use a duct with an as smooth as possible inside. ! The duct must be made of certified material. ! The company declines any responsibility whenever these regulations are
not respected.
FILTERING OR DUCTING ?
! Your cooker hood is ready to be used in suction version. To use the hood in filtering version the special ACCESSORY KIT must be
installed.
Check on the first pages of this manual if the ACCESSORY KIT is furnished
or must be bought separately.
Note: If furnished, in certain cases, the additional activated carbon filtering
system may be installed on the hood.
Information about the conversion of the hood from suction version to filtering
version is present in this manual.
Ducting version
In this case the fumes are conveyed outside by means of a special pipe connected with the connection ring located on top of the hood. Attention! The exhausting pipe is not supplied and must be purchased apart. Diameter of the exhausting pipe must be equal to that of the connection ring = 150mm. In the horizontal runs the exhausting pipe must be slightly slanted (about 10°) and directed upwards to vent the air easily from the room to the outside. Attention! If the hood is supplied with active charcoal filter, then it must be removed.
Filter version
One active charcoal filter is needed for this and can be obtained from your usual retailer. The filter removes the grease and smells from the extracted air before sending it back into the room through the upper outlet grid.
EN
9
Page 10
EN
CONTROLS
1 ON/OFF motor
Pressing the button, the hood turns on at speed 1. Pressing the button during functioning, the hood turns OFF.
2 Speed Increase
Pressing the button the hood passes from the OFF state to speed 1. Pressing the button (hood in ON state) the motor speed is increased from
speed 1 to intensive. To each speed corresponds the ignition of the respective led. Speed 1 led L1 Speed 2 led L2 Speed 3 led L3 Intensive Speed led L4 (flashing) The intensive speed is timed. The standard timing is 5’, at the end of which
the hood positions itself to speed 2. To deactivate the function before the time expires press key 2, the hood
positions itself to speed 1, pressing key 1 the hood will turn off.
3 ON/OFF lights 4 Speed timing 5 Function state indicator
Speed Timing
The timing of the speed is enabled by pressing key 4, once the timing expires the hood turns off. The timing is subdivided as follows: Speed 1 - 20 minutes (led L1 flashing) Speed 2 - 15 minutes (led L2 flashing) Speed 3 - 10 minutes (led L3 flashing) Intensive Speed - 5 minutes (led L4 flashing)
During the timed functioning presseing key 1 the hood turns offf, if you press key
2 or key 4 the hood returns to the set speed.
Grease trap Signal
After 40 hours of operation the led L5 turns on. When such signal appears the installed grease trap needs to be washed. To reset the signal hold down key 1 for 3”.
Carbon filter Signal
After 160 hours of operation the led L5 flashes. When such signal appears the installed carbon filter must be substituted. To reset the signal hold down key 1 for 3”.
In the case of both filters signalling at the same time, the led L5 will indicate the alarms alternately remaining on for 3" and subsequently flashing 3 times. The reset takes place by carrying out the procedure described above 2 times. The first time resets the grease trap signal, the second resets the carbon filter signal.
In the standard mode the carbon filter signal is not active. In case one uses the hood in filter version is it necessary to enable the carbon filter signal.
Carbon filter signal activation:
Position the hood in OFF and simultaneously hold down keys 1 and 4 for 3”. The led L1 and L2 will flash for 5”. Carbon filter signal deactivation: Position the hood in OFF and simultaneously hold down keys 1 and 4 for 3”. The led L1 will flash for 2”.
Temperature Alarm
The hood is equipped with a temperature sensor that activates the motor to speed 3 in the case that the temperature in the control zone becomes too elevated. The alarm condition is indicated with the sequential flash of the leds L1, L2, L3. This condition remains until the temperature falls below the alarm threshold. You can get out of this mode by pressing key 1 or 2. Every 30” the sensor checks the environmental temperature of the display zone.
10
Page 11
MAINTENANCE
ATTENTION! Before performing any maintenance operation, isolate the hood from the electrical supply by switching off at the connector and removing the connector fuse. Or if the appliance has been connected through a plug and socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the same frequency with which you carry out maintenance of the fat filters) internally and externally. Clean using the cloth dampened with neutral liquid detergent. Do not use abrasive products. DO NOT USE ALCOHOL! WARNING: Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks. Therefore, we recommend oserving these instructions. The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
Maintenance of the anti-grease filters
Traps cooking grease particles. This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity. To remove the grease filter, pull the spring release handle.
Maintenance of the charcoal filter
It absorbs unpleasant odours caused by cooking.
The saturation of the activated charcoal occurs after more or less prolonged use, depending on the type of cooking and the regularity of cleaning of the grease filter. In any case it is necessary to replace the cartridge at least every four mounths. The carbon filter may NOT be washed or regenerated.
Assembly
Hook the charcoal filter at the back on the metal tongue of the hood first, then on the front with the two knobs.
Disassembly
Remove the charcoal filter by turning the knobs fixing it to the hood by 90°.
EN
Replacing lamps
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are cooled down.
1. Using a flat head screwdriver or equivalent tool, carefully pry loose the light
cover.
2. Remove the damaged light and replace with a new 12 Volt, 20 Watt (Maximum) halogen light made for a G-4 base SUITABLE FOR USE IN OPEN LUMINAIRES. Follow package directions and do not touch new light with bare hands.
3. Reinstall the light cover. (it will snap shut).
11
Page 12
EN
DISPOSAL
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
The symbol product, indicates that this appliance may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal.
MALFUNCTIONS
If something appears not to be working properly, do the following simple checks before calling Technical Service:
If the hood is not working: Check that:
- The power has not been disconnected.
- A speed has been selected.
If the hood performs inefficiently: Check that:
- The motor speed selected is sufficient for the amount of smoke and vapours released.
- The kitchen is sufficiently ventilated to allow air intake.
- The charcoal filter is not worn (hood in filtering version).
If the hood has turned off during normal functioning:
Check that:
- The power has not been disconnected.
- the omnipolar disconnection device has not tripped.
If the hood fails to operate correctly, briefly disconnect it from the mains power supply for almost 5 sec. by pulling out the plug. Then plug it in again and try once more before contacting the Technical Assistance Service.
on the product, or on the documents accompanying the
LIB0007537
12/2009
TECHNICAL DATA
Model HS9EIX - HSD9EIX
Height 70-115 cm Width 89,8 cm Depth 45 cm Gross weight: 23,3 Kg (HS9EIX) - 25,6 Kg (HSD9EIX) Total absorption 215 W Motor absorption 1x175 W Lamp absorption 2x20 W (G4 - 12V) Exhaust pipe Ø 15 cm
Model HSD7EIX
Height 70-115 cm Width 69,8 cm Depth 45 cm Gross weight: 22,1 Kg Total absorption 215 W Motor absorption 1x175 W Lamp absorption 2x20 W (G4 - 12V) Exhaust pipe Ø 15 cm
Model HS6EIX - HSD6EIX
Height 70-115 cm Width 59,8 cm Depth 45 cm Gross weight: 19,9 Kg (HS6EIX) - 21,3 Kg (HSD6EIX) Total absorption 215 W Motor absorption 1x175 W Lamp absorption 2x20 W (G4 - 12V) Exhaust pipe Ø 15 cm
This appliance conforms to the following EEC Directive:
“Low Voltage Equipment” Directive 2006/95/EC (12-12-2006)
• “Electromagnetic Compatibility” Directive 2004/108/EC (15-12-2004)
Components not provided with the product