Hotpoint CX64SP4 User Manual

Operating Instructions
COOKER AND OVEN
GB
English,1
CX64SP4 IL CX64SP4 X IL
Contents
GB
Installation, 2-5
Positioning and levelling Electrical connection Gas connection Adapting to different types of gas Table of burner and nozzle specifications Table of characteristics
Description of the appliance, 6
Overall view Control panel
Start-up and use, 7-10
Using the hob Setting the time Using the oven Cooking modes Planning your cooking Practical cooking advice Oven cooking advice table
Precautions and tips, 11
General safety Disposal Respecting and conserving the environment
Care and maintenance, 12
Switching the appliance off Cleaning the appliance Replacing the oven light bulb Gas tap maintenance Assistance
Installation
GB
Before operating your new appliance please read this instruction booklet carefully. It contains important information concerning the safe installation and operation of the appliance.
Please keep these operating instructions for future reference. Make sure that the instructions are kept with the appliance if it is sold, given away or moved.
The appliance must be installed by a qualified professional according to the instructions provided.
Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply.
Room ventilation
The appliance may only be installed in permanently­ventilated rooms, in accordance with current national legislation. The room in which the appliance is installed must be ventilated adequately so as to provide as much air as is needed by the normal gas combustion process (the flow of air must not be lower than 2 m
3
/h per kW of installed power). The air inlets, protected by grilles, should have a duct with an inner cross section of at least 100 cm
2
and should be positioned so that they are not liable to even partial obstruction (see figure A). These inlets should be enlarged by 100% - with a minimum of 200 cm
2
- whenever the surface of the hob is not equipped with a flame failure safety device. When the flow of air is provided in an indirect manner from adjacent rooms (see figure B), provided that these are not communal parts of a building, areas with increased fire hazards or bedrooms, the inlets should be fitted with a ventilation duct leading outside as described above.
Adjacent room Room requiring
ventilation
AB
Disposing of combustion fumes
The disposal of combustion fumes should be guaranteed using a hood connected to a safe and efficient natural suction chimney, or using an electric fan that begins to operate automatically every time the appliance is switched on (see figure).
Fumes channelled Fumes channelled through straight outside a chimney or a branched
flue system (reserved for cooking appliances)
The liquefied petroleum gases are heavier than air and collect by the floor, therefore all rooms containing LPG cylinders must have openings leading outside so that any leaked gas can escape easily. LPG cylinders, therefore, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc.). Only the cylinder being used should be stored in the room; this should also be kept well away from sources of heat (ovens, chimneys, stoves) that may cause the temperature of the cylinder to rise above 50°C.
Positioning and levelling
It is possible to install the appliance alongside cupboards whose height does not exceed that of the hob surface.
Make sure that the wall in contact with the back of the appliance is made from a non-flammable, heat­resistant material (T 90°C).
A
Ventilation opening Increase in the gap between for comburent air the door and the flooring
After prolonged use of the appliance, it is advisable to open a window or increase the speed of any fans used.
2
To install the appliance correctly:  Place it in the kitchen, the dining room or the bed-
sit (not in the bathroom).
 If the top of the hob is higher than the cupboards,
the appliance must be installed at least 600 mm away from them.
 If the cooker is installed underneath a wall cabinet, there must be a minimum distance of 420 mm between this cabinet and the top of
700 mm. without hood
the hob.
min. 650 mm. with hood
min.
mm.
420
Min.
HOOD
Min. mm.
600
420
Min. mm.
This distance should be increased to 700 mm if the wall cabinets are
flammable (see figure).
 Do not position blinds behind the cooker or less
than 200 mm away from its sides.
 Any hoods must be installed according to the
instructions listed in the relevant operating manual.
Levelling
 The voltage is in the range between the values
indicated on the data plate.
 The socket is compatible with the plug of the
appliance. If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets.
Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced
by authorised technicians only.
The manufacturer declines any liability should these safety measures not be observed.
GB
If it is necessary to level the appliance, screw the adjustable feet into the places provided on each corner of the base of the cooker (see figure).
The legs* fit into the slots on the underside of the base of the cooker.
Electrical connection
Install a standardised plug corresponding to the load indicated on the appliance data plate (see Technical data table). The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the circuit-breaker). The supply cable must be positioned so that it does not come into contact with temperatures higher than 50°C at any point.
Before connecting the appliance to the power supply, make sure that:  The appliance is earthed and the plug is compliant with
the law.
 The socket can withstand the maximum power of the
appliance, which is indicated by the data plate.
Gas connection
Connection to the gas network or to the gas cylinder may be carried out using a flexible rubber or steel hose, in accordance with current national legislation and after making sure that the appliance is suited to the type of gas with which it will be supplied (see the rating sticker on the cover: if this is not the case see below). When using liquid gas from a cylinder, install a pressure regulator which complies with current national regulations. To make connection easier, the gas supply may be turned sideways*: reverse the position of the hose holder with that of the cap and replace the gasket that is supplied with the appliance.
Check that the pressure of the gas supply is consistent with the values indicated in the Table of burner and nozzle specifications (see below). This will ensure the safe operation and durability of your appliance while maintaining efficient energy consumption.
Gas connection using a flexible rubber hose
Make sure that the hose complies with current national legislation. The internal diameter of the hose must measure: 8 mm for liquid gas supply; 13 mm for methane gas supply.
Once the connection has been performed, make sure that the hose:  Does not come into contact with any parts that
reach temperatures of over 50°C.
 Is not subject to any pulling or twisting forces and
that it is not kinked or bent.
 Does not come into contact with blades, sharp
corners or moving parts and that it is not compressed.
3
GB
 Is easy to inspect along its whole length so that its
condition may be checked.  Is shorter than 1500 mm.  Fits firmly into place at both ends, where it will be
fixed using clamps that comply with current
regulations.
If one or more of these conditions is not fulfilled or if the cooker must be installed according to the conditions listed for class 2 - subclass 1 appliances (installed between two cupboards), the flexible steel hose must be used instead (see below).
Connecting a flexible jointless stainless steel pipe to a threaded attachment
Make sure that the hose and gaskets comply with current national legislation. To begin using the hose, remove the hose holder on the appliance (the gas supply inlet on the appliance is a cylindrical threaded 1/2 gas male attachment).
Perform the connection in such a way that the hose length does not exceed a maximum of 2 metres, making sure that the hose is not compressed and does not come into contact with moving parts.
Checking the tightness of the connection
Adapting to different types of gas
It is possible to adapt the appliance to a type of gas other than the default type (this is indicated on the rating label on the cover).
Adapting the hob
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off their seats.
2. Unscrew the nozzles using a 7 mm socket spanner (see figure), and replace them with nozzles suited to the new type of gas (see Burner and nozzle specifications table).
3. Replace all the components by following the above
instructions in reverse.
Adjusting the hob burners minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory screw, which is positioned inside or next to the tap pin, until the flame is small but steady. If the appliance is connected to a liquid gas supply, the regulatory screw must be fastened as tightly as possible:
When the installation process is complete, check the hose fittings for leaks using a soapy solution. Never use a flame.
3. While the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame is not extinguished.
The hob burners do not require primary air adjustment.
After adjusting the appliance so it may be used with a
different type of gas, replace the old rating label with a new one that corresponds to the new type of gas (these labels are available from Authorised Technical Assistance Centres).
Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet hose in accordance with current national regulations relating to regulators for channelled gas.
4