Hot Point AV447 Installation Manual

Safety Instructions ............ 2
Warranty ...................... 4
Assistance / Accessories ..... 5
Using The Hood
Controls .........................6
Care and Cleaning
Filters ............................6
Surfaces.........................7
Light .............................7
Installation Instructions ......8
Troubleshooting Tips ........16
Owner’s Manual and
Installation Instructions
JV247*– Vent & Recirculation options JV248*– Vent & Recirculation options JN327–Recirculation only JN328–Recirculation only JV338*–Vent options only JV347*– Vent & Recirculation options JV348*– Vent & Recirculation options JV367*– Vent & Recirculation options RN328–Recirculation only AV447*– Vent & Recirculation options
*
Range Hoods
Write the model and serial numbers here: Model # ______________________ Serial # _______________________
You can find them on a label on the back wall of the hood.
Español
For a Spanish version of this manual, visit our Website at
GEAppliances.com.
Para consultar una version
en español de este manual de
instrucciones, visite nuestro sitio
de internet GEAppliances.com.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These words are defined as:
DANGER
WARNING
CAUTION
Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
SAFETY PRECAUTIONS
SAFETY INFORMATION
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power
off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Do not use this unit with any solid-state speed
control device.
D. This unit must be grounded.
CAUTION
ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION
PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE. DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.
TO REDUCE THE RISK OF FIRE,
FOR GENERAL VENTILATING USE
TO REDUCE RISK OF FIRE AND TO
WARNING
TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
A. SMOTHER FLAMES with a close-fitting lid,
cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN—You may
be burned.
C. DO NOT USE WATER, including wet dishcloths
or towels—a violent steam explosion will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
*Based on “Kitchen Fire Safety” published by NFPA.
TO REDUCE THE RISK OF INJURY
READ AND SAVE THESE INSTRUCTIONS
2
49-80589-6
SAFETY PRECAUTIONS
SAFETY INFORMATION
WARNING
RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking on high heat
or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
C. Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
D. Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion
and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
TO REDUCE THE RISK OF A
TO REDUCE THE RISK OF FIRE,
C. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the
outdoors.
E. When applicable, install any makeup
(replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions.
F. Turn off breaker to adjacent rooms while
working.
WARNING
USE ONLY METAL DUCTWORK.
Ŷ Do not attempt to repair or replace any part of
your hood unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.
TO REDUCE THE RISK OF FIRE,
49-80589-6
READ AND SAVE THESE INSTRUCTIONS
3
Thank You! ... for your purchase of a GE Brand appliance.
Register Y our Appliance: Register your new appliance on-line at your convenience!
www.geappliances.com/service_and_support/register/
Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.
WARRANTY
GE Warranty
GEAppliances.com
All warranty service is provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, visit us at www.geappliances.com/service_and_support/, or call 800.GE.CARES (800.432.2737). Please have serial number and model number available when calling for service.
Servicing your appliance may require the use of the onboard data port for diagnostics. This gives a GE factory service technician the ability to quickly diagnose any issues with your appliance and helps GE improve its products by providing GE with information on your appliance. If you do not want your appliance data to be sent to GE, please advise your technician not to submit the data to GE at the time of service.
For the period of one year from the date of the original purchase, GE will provide any part of the hood which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.
What GE will not cover:
Ŷ Service trips to your home to teach you how to use
the product.
Ŷ Improper installation, delivery or maintenance. Ŷ Failure of the product if it is abused, misused,
modified or used for other than the intended purpose or used commercially.
Ŷ Replacement of house fuses or resetting of circuit
breakers.
Ŷ Damage to the product caused by accident, fire,
floods or acts of God.
Ŷ Damage to finish, such as surface rust, tarnish, or
small blemishes not reported within 48 hours of delivery.
Ŷ Incidental or consequential damage caused by
possible defects with this appliance.
Ŷ Damage caused after delivery. Ŷ Product not accessible to provide required service. Ŷ Service to repair or replace light bulbs, except for
LED lamps.
EXCLUSION OF IMPLIED WARRANTIES
Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home. Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
Staple your receipt here. Proof of the original purchase
date is needed to obtain service under the warranty.
Extended Warranties: Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime
www.geappliances.com/service_and_support/shop-for-extended-service-plans.htm
or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.
4
49-80589-6
Have a question or need assistance with your appliance?
Try the GE Appliances Website (www.geappliances.com/service_and_support/) 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line.
Schedule Service: Expert GE repair service is only one step away from your door. Get on-line and schedule your service at www.geappliances.com/service_and_support/ Or call 800.GE.CARES (800.432.2737) during normal business hours.
Parts and Accessories: Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted).Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.
Real Life Design Studio: GE supports the Universal Design concept of products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).
Contact Us: If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to:
General Manager, Customer Relations GE Appliances, Appliance Park Louisville, KY 40225
Accessories
Looking For Something More? GE offers a variety of accessories to improve your cooking and maintenance experiences!
To place an order visit us online at:
www.GEApplianceParts.com
or call 800.626.2002
The following products and more are available:
ASSISTANCE / ACCESSORIES
Parts
Charcoal Filter WB02X10700
How to Remove Protective Shipping Film and Packaging Tape
Carefully grasp a corner of the protective shipping film with your fingers and slowly peel it from the appliance surface. Do not use any sharp items to remove the film. Remove all of the film before using the appliance for the first time.
To assure no damage is done to the finish of the product, the safest way to remove the adhesive from packaging tape on new appliances is an application of a household liquid dishwashing detergent. Apply with a soft cloth and allow to soak.
NOTE: The adhesive must be removed from all parts.
49-80589-6
5
Controls
Throughout this manual, features and appearance may vary from your model.
Control Knobs (on some models)
OFF
LO HI
MED NITE
1
OFF OFF
HI ON
MED
LO
1
1. FAN Control: Turn to HI, MED or LO as needed.
Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling moisture that create a frequent need for cleaning.
2. LIGHT Control: Turn to ON while cooking or to
NITE for use as a night light.
OFF
ON
2
NITE
(AV447 models only)
2
Switch Pad Controls (on some models)
ON
OFF
12
1. LIGHT Control: Press the pad at the top to turn
the light ON.
2. Fan Settings Buttons: Press the pad at the
top to turn the fan on HI and at the bottom to turn it on LO. The center position is OFF.
Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling moisture that create a frequent need for cleaning.
OF
LO
HI
F
Filters
Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood.
5HXVDEOH0HWDO*UHDVH)LOWHU³'XFWHG,QVWDOODWLRQV2QO\
The efficiency of your hood depends on a clean filter. Frequency of cleaning depends on hood use and the
USING THE HOOD: Controls / CARE AND CLEANING: Filters
type of cooking you do. However, the grease filter should be cleaned at least once a month.
To remove:
Pull down on the center of the front edge of the filter. The filter will then slip out of the retaining tabs on the back.
To replace:
Slip the back edge of the filter into the retaining tabs and push the front edge up until it snaps into place.
To clean:
Soak and then agitate it in a hot water and detergent solution. Light brushing can be used to remove embedded dirt. Rinse, shake and let it dry before replacing.
NEVER OPERATE THE HOOD WITHOUT THE FILTER IN PLACE.
With careful handling, the metal filter will last for years. If a new replacement filter becomes necessary, order the part from your dealer. Order genuine GE part number WB02X8391.
Grease filter
6
49-80589-6
Filters (Cont.)
&KDUFRDO)LOWHU³5HFLUFXODWLQJ,QVWDOODWLRQV2QO\
The charcoal filter cannot be cleaned. It must be replaced. Order filter no. WB02X10700. Replacement filters can be ordered from your GE supplier.
If the hood is not vented to the outside, the air will be recirculated through a disposable charcoal filter that helps remove smoke and odors.
The charcoal filter should be replaced after 6 to 12 months (depending on hood usage).
To remove:
Pull down on the center of the front edge of the filter. The filter will then slip out of the retaining tabs on the back.
Surfaces
Stainless Steel Surfaces (on some models)
Do not use a steel-wool pad; it will scratch the surface.
To clean the stainless steel surface, use warm sudsy water or a stainless steel cleaner or polish. Always wipe the surface in the direction of the grain. Follow the cleaner instructions for cleaning the stainless steel surface.
CARE AND CLEANING: Filters / Surfaces / Light
To replace:
Slip the back edge of the filter into the retaining tabs and push the front edge up until it snaps into place.
Replaceable charcoal filter
NOTE: DO NOT rinse, or put charcoal filters in an automatic dishwasher.
To inquire about purchasing stainless steel appliance cleaner or polish, or to find the location of a dealer nearest you, please call our toll-free number:
National Parts Center
800.626.2002 GEApplianceParts.com
Painted Surfaces (on some models)
Do not use steel-wool pads or other abrasive cleaners. They will scratch the surface.
Clean grease-laden surfaces of the hood frequently. To clean the hood surface, use a hot, damp cloth with a mild detergent suitable for painted surfaces. About one tablespoon of ammonia may be added to the water. Use a clean, hot, damp cloth to remove soap. Dry with a dry, clean cloth.
Light
CAUTION
removing. A warm or hot bulb may break if touched with a moist cloth or hand.
Remove the bulb and replace it with a type A15 incandescent light bulb with an ordinary screw base, not more than 60 Watts, or a type A17 or T2 Compact Fluorescent (CFL) light bulb with an ordinary screw base, not more than 13 Watts. NOTE: Use only incandescent bulbs in models RN328, JN327, JN328 and JV338.
IMPORTANT: For installation, handling and disposal precautions, refer to the fluorescent bulb packaging literature.
To remove the light cover (on some models):
Ŷ 3UHVVWKHVLGHVZLWKWZRILQJHUVXQWLO
the side prongs are released.
Ŷ /LIWWKHOLJKWFRYHUDQGVOLGHLWWRZDUG
you in one motion.
Let the light bulb cool completely before
NOTE: When cleaning, take care not to come in contact with filters and other non-enameled surfaces.
CAUTION
certain that you do not touch the light bulb with moist hands or cloth. A warm or hot light bulb may break if touched with a moist surface. Always let the light bulb cool completely before cleaning around it.
To replace the light cover:
Ŷ ,QVHUWWKHSURQJORFDWHGDWWKHHQGRIWKHFRYHULQWR
the top opening.
Ŷ *HQWO\SXVKWKHFRYHUXSDQGSUHVVWKHVLGHVWRILW
the side prongs into the side openings.
Ŷ 5HOHDVHDQGWKHFRYHUZLOOORFNLQSRVLWLRQ
When cleaning the hood surfaces, be
When using an energy saving bulb in your GE hood make sure you use either:
GE Long Life Energy Smart™ Spiral® T2 Product Code: 85383 Description: FLE13HT2/2/SW/CD
Light cover
or GE Long Life Energy Smart™ A17
Product Code: 47486 Description: FLE11/2/A17XL/CD
Available at www.gelighting.com
49-80589-6
7
Installation
Range Hood
Instructions
“If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: GEAppliances.com”
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
INSTALLATION INSTRUCTIONS
instructions with the Consumer.
Note to Consumer – Keep these instructions for future reference.
Skill level – Installation of this vent hood requires basic mechanical and electrical skills.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under the Warranty.
FOR YOUR SAFETY:
WARNING
switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Before beginning the installation,
OPTIONAL POWER CORD KIT JXHC1
An optional Power Cord Connection Kit, model JXHC1, is available at extra cost from your GE supplier for installation using a standard 3-prong, grounded wall outlet. Follow the Installation Instructions packed with the kit to connect the power cord to the range hood.
DUCTWORK REQUIREMENTS
NOTE: Read the ductwork sections only if you do not have existing ductwork. If you have existing ductwork, skip to the “Damage” section and proceed.
WARNING
TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE—DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.
The venting system must exhaust to the outside. This hood can be vented vertically through upper
cabinets or horizontally through an outside wall. Ductwork is not included.
Exhaust connection:
The hood exhaust has been designed to mate with
VWDQGDUG»Ǝ[ƎUHFWDQJXODUGXFWLQJRUƎGLDPHWHU
round ducting.
,IDƎURXQGGXFWLVUHTXLUHGDUHFWDQJXODUWRURXQG
transition adaptor must be used*. Do not use less than DƎ diameter duct.
Duct length:
It is important that ducting be installed using the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps prevent blockages. Also, make sure dampers swing freely and nothing is blocking the ducts. When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions.
• Plan the route for venting exhaust to the outdoors. To maximize the ventilation performance of the vent system:
1. Minimize the duct run length and number of
transitions and elbows.
2. Maintain a constant duct size.
3. Seal all joints with duct tape to prevent any leaks.
4. Do not use any type of flexible ducting.
• Install a wall cap or roof cap with damper at the
exterior opening. Purchase the wall or roof cap and any transition and length of duct needed in advance.
TO REDUCE THE RISK OF FIRE AND
* IMPORTANT: If a rectangular-to-round
transition adaptor is used, the bottom corners of the damper will have to be cut to fit, using the tin snips, in order to allow free movement of the damper. Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any hood.
8
49-80589-6
Installation Instructions
INSTALLATION INSTRUCTIONS
DAMAGE – SHIPMENT/INSTALLATION
If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer.
MOUNTING SPACE
Bottom edge of
cabinet needs
to be 30s or
more from
the cooking
surface
24s,30s or 36
match cooktop
width
66s or more from the floor to the top of the hood
s to
NOTES:
• Hood width may be greater than the width of the range or cooktop, but it may not be smaller.
• Ensure the range or cooktop is installed per manufacturer’s installation instructions.
• If you are going to vent your range hood to the outside, see the “Ducting Requirements” section for exhaust duct preparation.
30s
min.
TOOLS YOU WILL NEED
Flat-blade and Phillips
screwdrivers
Saw (saber or
keyhole)
1/4s
pivoting
hex socket
Flashlight
Pliers
Caulking
Pencil
Electric drill
Tape measure
Level
Duct tape
Metal snips
(in some
applications)
Wire stripper
1/4s Nutdriver
PARTS INCLUDED
PART QUANTITY
Grease Filter only (JV338) 1 Charcoal Filter only
(JN327, JN328 and RN328) Grease Filter and
Charcoal Filter (JV24X, JV347, JV348, JV367 and AV447)
Mounting Screws (8 - 18" x 3/4" Phillips pan head)
Exhaust Adaptor (for 3 1/4" x 10" rect. venting)
Exhaust Adaptor Screw (8 - 18" x 3/8" Phillips pan head or hex head)
1
2
4
1
1
49-80589-6
9
Installation Instructions
1
CHOOSE VENT OPTION
Determine the vent option that your installation
will require and that is available for your model from the below choices.
IMPORTANT: If the hood is to be installed in a recirculating, non-vented, ductless manner, do not knock out any vent openings in the hood. Only an electrical access hole will be knocked out of the hood.
Outside top exhaust
A
(Vertical duct–3-1/4" x 10" Rectangular)
JV338 JV338
INSTALLATION INSTRUCTIONS
JV247 JV248 JV347 JV348 JV367 AV447
Outside rear exhaust
C
(Horizontal duct–3-1/4" x 10" Rectangular)
JV247 JV248 JV347 JV348 JV367 AV447
10
Outside top exhaust
B
(Vertical duct–7" Round)
JV338
JV247 JV248 JV347 JV348 JV367 AV447
Recirculating
D
(non-vented/ductless)
JN327 JN328 RN328
JV247 JV248 JV347 JV348 JV367 AV447
49-80589-6
Loading...