WARNING: Do not assemble, install, or operate this equipment without reading ALL of this manual
and the safety precautions and warnings illustrated in this manual.
KDAR Company Tel: (314) 692-8555
1 Mulch Lane Fax: (314) 692-8578
St. Louis, MO 63044 Web Site: www.hotmaxtorches.com
SAFETY PRECAUTIONS AND WARNINGS
PLEASE READ BEFORE USING EQUIPMENT
WARNING
ELECTRIC SHOCK CAN KILL.
The input circuits are live and hot when the power is on
Do not touch live electrical parts
Wear dry, hole free insulated work gloves and body protection when operating
Do not touch torch components if in contact with the work piece or ground
Always turn off power before cleaning, checking, or changing parts
Properly ground this piece of equipment per state and federal requirements
Inspect and replace any worn or damaged torch cables or leads
Keep all panels and covers securely in place
Keep away from the torch tip and weld arc when trigger is pressed
Ground the metal or work piece to the ground cable (Earth Clamp)
Never dip the tip into water to cool or attempt to use welder in or under water
This DC equipment holds a lot of power in the off position, before touching, make sure voltage is
near zero on input capacitors before touching any parts.
Keep children away from this equipment
Protect yourself and others from possible injury
Pacemaker wearers should consult with their doctor before operating
Read and follow all instructions in this manual before operating
All installation, operation, and maintenance procedures are to be
performed only by qualified individuals
ARC RAYS CAN BURN SKIN AND EYES
Arc rays when welding produce intense ultraviolet and infrared rays that can burn skin and eyes
Wear face protection, either helmet or shield, when operating. ANSI Z49.1 approved shade #9
recommended for all cutting currents less than 300 amperes. The lens should conform to ANSI
Z87.1 standards for testing.
Wear approved safety glasses with side shields under the face protection
Warn others not to stare at the arc as it can cause damage to the eyes. Provide barriers to protect
other workers in the area from the arc while operating
Wear flame resistant gloves, clothing, and shoes when operating
FUMES AND GASES CAN BE HAZARDOUS
Arc welding produces fumes and gases and breathing these gases is hazardous to your health
Keep your head out of the fumes and do not breath the fumes while welding
Work only in a confined area if it has sufficient ventilation, or while wearing an air supplied
respirator. Fumes from welding deplete the oxygen supply and can be harmful. Always be sure
there is ample breathing air
Read the MSDS sheets and the instructions from manufacturers for metals to be welded, coatings,
and cleaners
Do not use the welder near hydrocarbon vapors coming from degreasing, cleaning, or spraying
operations. The heat and rays can react with solvent vapors to create the gas phosgene, a very toxic
gas and other irritating gases
Do not weld coated metals, such as galvanized, lead, or cadmium plated steel. Before welding, all
plating must be removed. The area must be well ventilated or an air supplied hood must be used.
The coatings and chemicals when burned cause highly irritating and toxic fumes.
Do not weld containers with toxic, flammable, or reactive elements stored in them. They must be
emptied and properly prepared before welding.
KDAR Company 1
WELDING SPARKS CAN CAUSE INJURY, FIRE, OR EXPLOSION
Remove all flammable materials from the welding area
Always have a charged fire extinguisher available in the welding area
When not welding make sure the welding tip is not grounded, this causes a heat build up and
possible fire
Avoid welding near hydraulic lines, fuel lines, electrical cords, air hoses, or welding guns and
cables
Sparks and hot metal fly out from the work area when welding, wear approved safety glasses with
side shields under approved helmets, wear proper body and hand protection, and wear flame
resistant ear plugs to keep sparks from entering the ears
CYLINDERS CAN EXPLODE IF DAMAGED
Gas cylinders contain gas under very high pressure. If damaged they can result in that cylinder ex-
ploding. Gas cylinders are a major part of metalworking and must be treated with care.
Protect gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs
Always keep cylinders in an upright position securely fastened to a fixed support
Valve protection caps should always be in place and hand tight except when the cylinder is in use
Keep all cylinders away from any welding or electrical circuits
Never allow the arc from a welder to contact a cylinder
Never cut any type of pressurized cylinder, an explosion could result
Always turn your face away from the valve when opening the cylinder
Read and follow all instructions on compressed gas cylinders, associated equipment, and CGA pub-
lication P-1 listed in the Safety Standards before using
ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS
Electric current used in arc welding can create Electro-Magnetic Fields (EMF)
Magnetic fields can affect pacemakers and wearers should avoid proximity to EMF. Wearers need
to contact their doctors before operating this type of equipment
Exposure to EMF during operation of this equipment may have other health effects which are not
yet known
Route the work and torch cables together and not around your body
Do not place your body between the torch cable and the ground cable. They both need to be on the
same side of your body when operating
Do not work next to the welding machine
ELECTRICALLY POWERED EQUIPMENT
Disconnect power source or turn off circuit breaker at the power panel before working on any
equipment
Only install equipment using the US National Electrical Code, all local codes, and the man-
ufacturer’s recommendations
HOT PARTS CAN CAUSE SERIOUS BURNS
Do not touch hot parts without wearing protection.
Allow the torch to cool sufficiently before working with parts that could potentially be hot.
KDAR Company 2
NOISE CAN DAMAGE HEARING
Prolonged noise exposure from welding equipment can cause damage if levels of noise exceed the
OSHA standards
Wear approved hearing protectors
Warn other workers nearby of the high noise level and hazard
CALIFORNIA PROPOSITION 65 WARNINGS
Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause
birth defects, and in some cases, cancer. (California Health and Safety Code Section 25249.5 et seq.)
PRINCIPAL SAFETY STANDARDS
AMERICAN WELDING SOCIETY
AWS C5.2, Recommended Practices for Plasma Arc Cutting
AWS F4.1, Recommended Safe Practices for the Preparation for Welding and Cutting
OSHA STANDARDS
OSHA 29 CFR 1910, Safety and Health Standards
NATIONAL FIRE PROTECTION ASSOCIATION
NFPA Standard 70, National Electric Code
NFPA Standard 51B, Cutting and Welding Processes
AMERICAN NATIONAL STANDARDS INSTITUTE
ANSI Standard Z87.1, Safe Practices for Occupation and Educational Eye and Face Protection
ANSI Standard Z49.1, Safety in Welding and Cutting
Light weight, small size all steel case.
Easy to use.
MIG/MAG ready, regulator and 5’ hose in-
cluded.
Optional spool gun available.
Infinite output voltage level.
Infinite wire feed speed control.
Wire at gun is “cold” when not welding.
Power on indicator light and overload indicator
light equipped.
Fan cooled.
20% duty cycle minimum.
Welds 22 gauge to 3/8” with flux cored wire.
Built in wire feeder with easy to use tension
adjustment lever.
Dual size groove drive roller to fit sizes .23”
to .35” wire (.6 to .9 mm).
.025”-.030” (0.6-0.8mm) solid steel
.030”-.035” (0.8-0.9mm) Flux-Cored
4”x2” (100mmx50mm)
Table 1
Easy polarity change for switching to and from
gas.
Flux covered (FCAW) set up from the factory,
ready to weld.
Welds steel, aluminum, and stainless (special
gas required for aluminum and stainless).
2 year limited warranty on the machine.
90 day limited warranty on gun and hose.
Comes with the following components.
2 replacement tips
Hex wrench to change wire feed roller.
Gas nozzle for MIG welding.
10# spool adaptor.
Gas regulator
5’ gas hose
2# Spool .030” Flux Core Wire
KDAR Company 4
Safety Considerations
Warning
Electric Shock Can Kill
Only qualified personnel should attempt to install this equipment.
Turn off the input power at the power panel or disconnect switch and discharge
capacitors before working inside the equipment.
Take care not to touch electrically hot parts
Make sure the unit is switched off before plugging it into a the power outlet.
Package Contents