GENERAL SAFETY WARNINGS
Do not install your hermetic stove into traditional chimney
Do not use bottled gas upside down or tilted.
Hose of your stove must not be longer than 130 cm.
Use TSE certified bottled gas. Do not use crushed and crooked bottled gas.
Absolutely use hood with 300mmSS constant pressure for the usage of LPG
Keep bottled gas away from flames. Check gas leakage with soap bubbles and special liquid.
Tighten hose terminations with clamp.
Do not put any container having liquids in it on your stove.
Attention! failures causing from these reasons are not covered by this guarantee
WARNING: Fire ,burning,inhalation and explosion hazard.Keep all flammable object as follows building materials,paper or carton unites away from heater according to the instructions.Never use this appliance in such rooms where there are flammable volatile materials or the following materials,which can get into the device petrol,solvent,thinner,fine grained dusty or unknown cemical materials.
2
CE MARKING CE marking fulfills the requirement of appliances burning gaseous fuels 90/396/EEC (GD453/2003) directive.Stove comply to. EN 613 Independent gas-fired convection heaters UE 2016/426 Gas Appliance Regulation (GAR) 2011/65/EU Directive on the restriction of use of certain hazardous substance (RoHS) 2009/125/ECEcodesign requirements forenergy-reletad products(ErP)
Regular control (e.g: yearly maintenance) of stove must be ensured.
In the replacement of parts of device, only original parts specified by the manufacturer must be used.
3
INDEX
1. Hermetic stove features
………………………………………………
4
2. Warnings before installation
………………………………………………
4
3. Site Selection
………………………………………………
4
4. Installation
………………………………………………
7
5. Feature of Vented Stove
………………………………………………
7
5.1. Connecting vented stove to the flue
………………………………………………
8
5.2. Placement of flue to the stove
………………………………………………
8
6. Gas connection type
………………………………………………
9
6.1 Natural Gas Connection
………………………………………………
10
6.2 Bottled gas (LPG) Connection
………………………………………………
10
6.3 Gas Leakage Control
………………………………………………
11
7. Commissioning of the device
………………………………………………
12
8. Usage of device
………………………………………………
12
8.1- Combustion of pilot
………………………………………………
13
8.2- Adjusting Ambient Temperatures
………………………………………………
13
8.3 Extinguishing of the stove
………………………………………………
13
9. Cleaning of device
………………………………………………
14
10. Technical information
………………………………………………
14
11. Gas conversion
………………………………………………
15
12. Safety rules
………………………………………………
15
13. Transport and shipping
………………………………………………
15
14. Important Notes
………………………………………………
16
15. Declaration of Conformity
………………………………………………
18
16. Producer-Manufacturer Info
………………………………………………
18
17. Authorized service centers
………………………………………………
18
4
1. HERMETIC STOVE FEATURES
It operates independently from its environment with special smoke duct. It takes necessary fresh air from external environment thanks to special smoke duct, and also it releases exhaust gas with special smoke duct to the external environment. When pilot flame extinguishes due to any reason, system automatically closed itself and secured.
It burns its fuel in high efficiency and with blue flame. Due to superior gas control system, it is ignited easily by only pressing lighter button. It is pilot light safety. In case of extinguishing flame, it has a magnet valve safety system, which cuts gas automatically. It has minimum and maximum combustion setting to provide fuel savings. The efficiency is increased due to the special design of combustion chamber.
The combustion can be observed due to special thermal shock resistant glass, which is made from ceramic material. The heated surfaces are covered with high quality enamel. External body color is specially designed in order to complete decoration of your house.
2. WARNING BEFORE INSTALLATION
The specification published by Local Gas Distribution Company must be followed for the installation and the place, where the device will be installed. Follow this instruction manual in order to use your stove in safety and high efficiency. The installation and mounting of stove belongs to the user.
Ensure that your stove will be mounted by authorized service or qualified plumber. Be careful that whether your stove is adjusted for natural gas or LPG or not. Do not touch any parts of the stove except for the matters referred in this instruction manual. Secure the legs of stove with screws.
3. SITE SELECTION
Your natural gas stove is a device with atmospheric burners, which takes air from external environment as independently from internal environment and discharge burned gases. The installation of the device must be carried out in the wall, which has facade to the outside atmosphere.
Hermetic kit installation is not permitted in the following locations. Closed balcony, underpasses and building entrances, staircase, areas and building spaces, which are narrow and air circulation is not available, etc.
5
The wall, where device connection will be done, must be fireproof and resistant to minimum 270C. The outlet in the external wall cannot be opened to everywhere. Take measures by replacing protective marble, plates, etc. under your stove. Do not connect hermetic kit to the flue.
Hermetic kit connection must be at least 60 cm in each direction of flammable surface coating and vertical distance must be at least 1.5 m to the roof eaves. In the area shown in the figure; the distance of location, where hermetic kit holes are connected from wall, must be as shown in the figure.
Figure 1: Stove mounting distances
WARNING: The specified fire protection distance as shown in the İnstruction .It must be
strictly kept and checked. The installation must comply for valid standards. Disregard of
these instruction can result in death ,injury or property damage.
WARNING: The installation of appliance must be only executed by authorized persons.
Quarantee of appliance can be ensured only in this case.
WARNING: Before every maintanance ,the appliance must be turned off electrical and gas
Supply.
Disregard of these instruction can result in death ,injury or property damage
6
Diameter of hole to be drilled on the wall is 27 cm. Hermetic stove must be mounted to the wall, of which external side is open. Lower edge of the exhaust duct outlet mouth must be at least 30 cm above from ground. Wall thickness must be maximum 42 cm, minimum 20 cm. Make sure that minimum 1 cm, maximum 5 cm between air inlet holes and wall surface.
This distance can be adjusted with telescopic flue kit. At least 2,5 meters distance must be available between exhaust gas pipes in the building façade If stove will be mounted under the window, the distance between lower edge of window and upper edge of pipe must be at least 30 cm.
In the mounting of device to the sidewalk-fronted walls, the distance between exhaust pipe outlet and ground must be 2m. For places such as semi-basement, on condition that to take safety measures it can be 1 m.
Figure-2: Mounting towards pavement Exhaust gas pipe outlet must be at least 40 cm above the roof surface.
Figure 3: Mounting to penthouse
7
4. INSTALLATION
Remove stove from its packaging by holding its sides. Drill flue hole of your Hoşseven natural gas stove according to wall mounts scheme as shown in Figure 9. Drill screw holes and insert dowels on condition that measures will be taken into account in the same way. Ensure that the wall, where installation to be done, is heat resistant or necessary isolations are done in order to make it resistant, due to rear body of the stove will be heated during combustion.
To remove body completely by removing screws on the each side of device. Replace exhaust gas pipe to the combustion chamber by fixing with screws and mount it with 4 screws as shown in Figure 7.
Hermetic kit must be installed as 3% inclined downwards.
Figure 4: Flue installation slope
The distance between gas outlet and external wall surface must be at most 5 cm. Please note this distance. Gas outlet pipe of your stove is telescopic; make distance adjustment according to this standard size.
Reinstall body to its place, after make necessary connections and tests.
5. VENTED STOVE FEATURES
It is used by connecting flue in its environment. Gas connection is located outside of the
stove, it is not necessary to dismantle any part for connection. It is connected to flue by using ø
13cm pipe thanks to adaptor provided with your stove. Special flue safety system completely turn-off your stove, when flue draught is insufficient or backlash of flue. It prevents the spreading of flue gas to the environment. It burns its fuel in high efficiency and with blue flame. It is easy to use due to superior gas control system. Due to Piezo igniter system, it is ignited easily by only pressing lighter button.
It is pilot light safety. In case of extinguishing flame, it has a magnet valve safety system, which cuts gas automatically. It has minimum and maximum combustion setting to provide fuel savings. The efficiency is increased due to the special design of combustion chamber. The