Hoshizaki America KM-131SRH3 Installation Manual

Hoshizaki America, Inc.
Hoshizaki
Stackable Crescent Cuber
Models KM-1301SAH/3
“A Superior Degree
of Reliability”
www.hoshizaki.com
KM-1301SWH/3 KM-1301SRH/3
INSTRUCTION MANUAL
Issued: 9-4-2008
IMPORTANT
Only qualied service technicians should attempt to install, service, or maintain this icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation. Failure to install, operate, and maintain the equipment in accordance with this manual may adversely affect safety, performance, and warranty coverage.
Hoshizaki provides this manual primarily to assist qualied service technicians in the installation, maintenance, and service of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, write, or send an e-mail message to the Hoshizaki Technical Support Department for assistance.
HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City, GA 3069
Attn: Hoshizaki Technical Support Department
Phone: 1-800-33-1940 Technical Service (770) 487-331 Fax: 1-800-843-1056 (770) 487-3360 E-mail: techsupport@hoshizaki.com
Web Site: www.hoshizaki.com
NOTE: To expedite assistance, all correspondence/communication MUST include the following information:
• Model Number ________________________
• Serial Number ________________________
• Complete and detailed explanation of the problem.
IMPORTANT
This manual should be read carefully before the icemaker is installed and operated. Only qualied service technicians should install, service, and maintain the icemaker. Read the warnings contained in this booklet carefully as they give important information regarding safety. Please retain this booklet for any further reference that may be necessary.
CONTENTS
I. Specications ..................................................................................................................... 4
A. Nameplate Rating ......................................................................................................... 4
1. KM-1301SAH (air-cooled) ....................................................................................... 4
. KM-1301SAH3 (air-cooled) .....................................................................................
3. KM-1301SWH (water-cooled) ................................................................................. 6
4. KM-1301SWH3 (water-cooled) ............................................................................... 7
5. KM-1301SRH (remote air-cooled) ........................................................................... 8
6. KM-1301SRH3 (remote air-cooled) ......................................................................... 9
B. Dimensions/Connections ............................................................................................ 10
1. KM-1301SAH/3 ..................................................................................................... 10
. KM-1301SWH/3 .................................................................................................... 11
3. KM-1301SRH/3 ..................................................................................................... 1
II. Installation and Operating Instructions ............................................................................ 13
A. Checks Before Installation .......................................................................................... 13
B. How to Remove Panels .............................................................................................. 13
C. Location ...................................................................................................................... 14
D. Setup .......................................................................................................................... 14
E. Installation of Second Unit .......................................................................................... 16
F. Electrical Connection .................................................................................................. 18
G. Installation of Remote Condenser Unit ....................................................................... 19
1. Checks Before Installation ..................................................................................... 19
. Location ................................................................................................................. 19
3. Setup ..................................................................................................................... 0
4. Line Set ................................................................................................................. 0
5. Electrical Connection ............................................................................................. 
6. Stacking Remote Condenser Unit ......................................................................... 3
H. Water Supply and Drain Connections......................................................................... 3
I. Final Checklist ............................................................................................................. 7
J. Startup ......................................................................................................................... 8
III. Cleaning and Maintenance ............................................................................................. 9
A. Cleaning and Sanitizing Instructions .......................................................................... 9
1. Cleaning Procedure ............................................................................................... 30
. Sanitizing Procedure - Following Cleaning Procedure .......................................... 31
B. Maintenance Instructions ............................................................................................ 3
C. Preparing the Icemaker for Long Storage .................................................................. 3
5
3
I. Specications
HOSHIZAKI ICE MAKER
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT

A. Nameplate Rating

1. KM-1301SAH (air-cooled)

MODEL NUMBER KM-1301SAH SERIAL NUMBER AC SUPPLY VOLTAGE
COMPRESSOR 208-230V 10.0RLA 61LRA PUMP 120V 1.2FLA 60W FAN 115V 0.85FLA 50W OTHER 115-120V 0.3A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER(USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-467PSI LO-230PSI REFRIGERANT 404A 3 LBS. 15.4 OZ.
208-230/60/1 (3 WIRE
WITH NEUTRAL FOR
115V)
See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel. Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
4

2. KM-1301SAH3 (air-cooled)

HOSHIZAKI ICE MAKER
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
MODEL NUMBER KM-1301SAH3 SERIAL NUMBER AC SUPPLY VOLTAGE
COMPRESSOR 208-230V 7.1RLA 55LRA PUMP 120V 1.2FLA 60W FAN 115V 0.85FLA 50W OTHER 115-120V 0.3A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER(USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-467PSI LO-230PSI REFRIGERANT 404A 3 LBS. 15.4 OZ.
208-230/60/3
See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel. Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
5

3. KM-1301SWH (water-cooled)

HOSHIZAKI ICE MAKER
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
MODEL NUMBER KM-1301SWH SERIAL NUMBER AC SUPPLY VOLTAGE
COMPRESSOR 208-230V 8.2RLA 56LRA PUMP 120V 1.2FLA 60W FAN --- --- --­OTHER 115-120V 0.3A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER(USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-427PSI LO-230PSI REFRIGERANT 404A 2 LBS. 8.2 OZ.
208-230/60/1 (3 WIRE
WITH NEUTRAL FOR
115V)
See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel. Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
6

4. KM-1301SWH3 (water-cooled)

HOSHIZAKI ICE MAKER
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
MODEL NUMBER KM-1301SWH3 SERIAL NUMBER AC SUPPLY VOLTAGE
COMPRESSOR 208-230V 6.1RLA 51LRA PUMP 120V 1.2FLA 60W FAN --- --- --­OTHER 115-120V 0.3A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER(USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-427PSI LO-230PSI REFRIGERANT 404A 2 LBS. 8.2 OZ.
208-230/60/3
See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel. Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
7

5. KM-1301SRH (remote air-cooled)

HOSHIZAKI ICE MAKER
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
MODEL NUMBER KM-1301SRH SERIAL NUMBER AC SUPPLY VOLTAGE
COMPRESSOR 208-230V 9.3RLA 56LRA PUMP 120V 1.2FLA 60W FAN REMOTE 120V 3A MAX OTHER 115-120V 0.3A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER(USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-467PSI LO-230PSI REFRIGERANT 404A
208-230/60/1 (3 WIRE
WITH NEUTRAL FOR
115V)
See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel. Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
8

6. KM-1301SRH3 (remote air-cooled)

HOSHIZAKI ICE MAKER
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
MODEL NUMBER KM-1301SRH3 SERIAL NUMBER AC SUPPLY VOLTAGE
COMPRESSOR 208-230V 6.2RLA 51LRA PUMP 120V 1.2FLA 60W FAN REMOTE 120V 3A MAX OTHER 115-120V 0.3A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER(USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-467PSI LO-230PSI REFRIGERANT 404A
208-230/60/3
See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel. Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
9

B. Dimensions/Connections

1. KM-1301SAH/3

Unit: (mm) inches
Note: When used with a storage bin not recommended by Hoshizaki, the icemaker
needs the space at the bottom opening as in the illustration.
10

2. KM-1301SWH/3

Unit: (mm) inches
Note: When used with a storage bin not recommended by Hoshizaki, the icemaker
needs the space at the bottom opening as in the illustration.
11