Hoshizaki America F-2000MRH Installation Manual

Reliability is a beautiful thing
TM
MODULAR FLAKER
F-2000MWH(-C) F-2000MRH(-C) F-2000MRH3(-C)
INSTRUCTION MANUAL
ISSUED: REVISED:
February 28, 2001
December 30, 2004
IMPORTANT
Only qualified service technicians should attempt to install, service or maintain this icemaker. No installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the installation, maintenance and service of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department for assistance.
HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: (770) 487-3360
Web Site: www.hoshizakiamerica.com
Note: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem
2
• Please review this manual. It should be read carefully before the icemaker is installed and operated. Only qualified service technicians should install, service and maintain the icemaker. This manual should be made available to the technician prior to installation, maintenance or service.
• Keep this manual with the icemaker for later reference.
CONTENTS
I. Specifications .................................................................................................................... 4
1. Nameplate Rating ........................................................................................................ 4
[a] F-2000MWH, F-2000MWH-C (water-cooled) ........................................................ 4
[b] F-2000MRH, F-2000MRH-C (remote air-cooled) .................................................. 5
[c] F-2000MRH3, F-2000MRH3-C (remote air-cooled) ............................................... 6
2. Dimensions/Connections ............................................................................................. 7
[a] F-2000MWH, F-2000MWH-C ................................................................................ 7
[b] F-2000MRH, F-2000MRH-C, F-2000MRH3, F-2000MRH3-C............................... 8
[c] With Storage Bin .................................................................................................... 9
[d] Condenser Unit Model URC-20F ........................................................................ 10
II. Installation and Operating Instructions ............................................................................ 11
1. Checks Before Installation .......................................................................................... 11
2. How to Remove Panels .............................................................................................. 11
3. Location ...................................................................................................................... 12
4. Setup .......................................................................................................................... 12
5. Electrical Connection ................................................................................................. 13
6. Installation of Remote Condenser Unit ....................................................................... 14
[a] Checks Before Installation ................................................................................... 14
[b] Location ............................................................................................................... 14
[c] Setup ................................................................................................................... 15
[d] Electrical Connection .......................................................................................... 16
[e] Stacking Condenser Unit .................................................................................... 17
7. Water Supply and Drain Connections......................................................................... 17
8. Final Checklist ............................................................................................................ 19
9. Startup ........................................................................................................................ 20
10. Preparing the Icemaker for Long Storage ................................................................. 21
III. Cleaning and Maintenance ............................................................................................ 22
1. Cleaning and Sanitizing Instructions .......................................................................... 22
[a] Cleaning Solution ................................................................................................ 22
[b] Cleaning Procedure ............................................................................................ 22
[c] Sanitizing Solution............................................................................................... 23
[d] Sanitizing Procedure - Initial................................................................................ 23
[e] Sanitizing Procedure - Final ................................................................................ 24
2. Maintenance Instructions ............................................................................................ 26
3

I. Specifications

1. Nameplate Rating

[a] F-2000MWH, F-2000MWH-C (water-cooled)

HOSHIZAKI ICE MAKER
MODEL NUMBER SERIAL NUMBER AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR GEAR MOTOR FAN MOTOR OTHER MAXIMUM FUSE USE MAX. HACR BREAKER (USA ONLY) MAX. CIRC. BREAKER (CANADA ONLY) MINIMUM CIRCUIT AMPACITY DESIGN PRESSURE REFRIGERANT 404A MOTOR-COMPRESSOR THERMALLY PROTECTED NOT INTENDED FOR OUTDOOR USE
240V 10.8RLA 96LRA 120V 5.6FLA 0.54HP
115V 0.51FLA 8W 120V 0.03A
HI-427PSI LO-290PSI
F-2000MWH
30 AMPS 30 AMPS 30 AMPS 30 AMPS
2 lb.
See the nameplate for electrical and refrigeration specifications. This nameplate is located on the right hand side of rear panel.
We reserve the right to make changes in specifications and design without prior notice.
NOTE: Only the “MODEL NUMBER” is replaced for F-2000MWH-C.
4

[b] F-2000MRH, F-2000MRH-C (remote air-cooled)

HOSHIZAKI ICE MAKER
MODEL NUMBER SERIAL NUMBER AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR GEAR MOTOR FAN MOTOR OTHER MAXIMUM FUSE USE MAX. HACR BREAKER (USA ONLY) MAX. CIRC. BREAKER (CANADA ONLY) MINIMUM CIRCUIT AMPACITY DESIGN PRESSURE REFRIGERANT 404A MOTOR-COMPRESSOR THERMALLY PROTECTED NOT INTENDED FOR OUTDOOR USE
REMOTE 120V 3A MAX.
240V 10.8RLA 96LRA 120V 5.6FLA 0.54HP
120V 0.03A
HI-427PSI LO-290PSI
F-2000MRH
30 AMPS 30 AMPS 30 AMPS 30 AMPS
See the nameplate for electrical and refrigeration specifications. This nameplate is located on the upper right hand side of rear panel.
We reserve the right to make changes in specifications and design without prior notice.
NOTE: Only the “MODEL NUMBER” is replaced for F-2000MRH-C.
5

[c] F-2000MRH3, F-2000MRH3-C (remote air-cooled)

HOSHIZAKI ICE MAKER
MODEL NUMBER SERIAL NUMBER AC SUPPLY VOLTAGE COMPRESSOR GEAR MOTOR FAN MOTOR OTHER MAXIMUM FUSE USE MAX. HACR BREAKER (USA ONLY) MAX. CIRC. BREAKER (CANADA ONLY) MINIMUM CIRCUIT AMPACITY DESIGN PRESSURE REFRIGERANT 404A MOTOR-COMPRESSOR THERMALLY PROTECTED NOT INTENDED FOR OUTDOOR USE
REMOTE 120V 3A MAX.
240V 9.0RLA 75LRA 120V 5.6FLA 0.54HP
120V 0.03A
HI-427PSI LO-290PSI
F-2000MRH3
208-230/60/3
20 AMPS 20 AMPS 20 AMPS 20 AMPS
See the nameplate for electrical and refrigeration specifications. This nameplate is located on the upper right hand side of rear panel.
We reserve the right to make changes in specifications and design without prior notice.
NOTE: Only the “MODEL NUMBER” is replaced for F-2000MRH3-C.
6

2. Dimensions/Connections

[a] F-2000MWH, F-2000MWH-C

Unit = inches [mm.]
7

[b] F-2000MRH, F-2000MRH-C, F-2000MRH3, F-2000MRH3-C

Unit = inches [mm.]
8

[c] With Storage Bin

Unit = inches [mm.]
9