Hoshizaki America F-1500MAH Service Manual

Reliability is a beautiful thing
TM
MODULAR FLAKER
F-1500MAH(-C) F-1500MWH(-C)
SERVICE MANUAL
F-1500MRH(-C)
ITEM #: ISSUED:
REVISED:
73111
May 25, 2004
October 11, 2005
IMPORTANT
Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department for assistance.
HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: (770) 487-3360
Web Site: www.hoshizakiamerica.com
Note: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem
2
CONTENTS
I. Specifications .................................................................................................................... 5
1. Icemaker ....................................................................................................................... 5
F-1500MAH................................................................................................................ 5
F-1500MAH-C ............................................................................................................ 6
F-1500MWH ............................................................................................................... 7
F-1500MWH-C ........................................................................................................... 8
F-1500MRH ............................................................................................................... 9
F-1500MRH-C.......................................................................................................... 10
2. Condenser Unit .......................................................................................................... 11
URC-12F.................................................................................................................. 11
II. General Information ........................................................................................................ 13
1. Construction ............................................................................................................... 13
F-1500MAH(-C)........................................................................................................ 13
F-1500MWH(-C) ....................................................................................................... 14
F-1500MRH(-C) ....................................................................................................... 15
2. Control Box Layout ..................................................................................................... 16
F-1500MAH(-C)........................................................................................................ 16
F-1500MWH(-C), F-1500MRH(-C) ........................................................................... 17
III. Technical Information ..................................................................................................... 18
1. Water Circuit and Refrigeration Circuit........................................................................ 18
F-1500MAH(-C)........................................................................................................ 18
F-1500MWH(-C) ....................................................................................................... 19
F-1500MRH(-C) ....................................................................................................... 20
2. Wiring Diagrams ......................................................................................................... 21
F-1500MAH(-C)........................................................................................................ 21
F-1500MWH(-C) ....................................................................................................... 22
F-1500MRH(-C) ....................................................................................................... 23
3. Sequence of Electrical Circuit .................................................................................... 24
4. Timing Chart ............................................................................................................... 32
5. Performance Data ....................................................................................................... 37
F-1500MAH.............................................................................................................. 37
F-1500MAH-C .......................................................................................................... 38
F-1500MWH ............................................................................................................. 39
F-1500MWH-C ......................................................................................................... 40
F-1500MRH ............................................................................................................. 41
F-1500MRH-C.......................................................................................................... 42
IV. Adjustment of Components ............................................................................................ 43
1. Adjustment of Water Regulating Valve (water-cooled model only).............................. 43
2. Adjustment of Flake Size ............................................................................................ 44
3. Adjustment of Cubelet Size ........................................................................................ 44
V. Service Diagnosis ........................................................................................................... 45
1. No Ice Production ....................................................................................................... 45
2. Low Ice Production ..................................................................................................... 48
3. Other ........................................................................................................................... 49
3
VI. Removal and Replacement of Components .................................................................. 50
1. Service for Refrigerant Lines ...................................................................................... 50
[a] Refrigerant Recovery........................................................................................... 50
[b] Evacuation and Recharge [R-404A] .................................................................... 50
2. Brazing ....................................................................................................................... 51
3. Removal and Replacement of Compressor ................................................................ 52
4. Removal and Replacement of Drier ........................................................................... 53
5. Removal and Replacement of Expansion Valve........................................................ 54
6. Removal and Replacement of Water Regulating Valve (water-cooled models only) .. 55
7. Removal and Replacement of Condensing Pressure Regulator (C.P.R.)
(remote air-cooled model only) ................................................................................... 56
8. Removal and Replacement of Evaporator Assembly ................................................. 57
9. Removal and Replacement of Fan Motor ................................................................... 61
10. Removal and Replacement of Control Water Valve .................................................. 61
11. Removal and Replacement of Flush Water Valve ..................................................... 62
VII. Cleaning and Maintenance .......................................................................................... 63
1. Preparing the Icemaker for Long Storage ................................................................... 63
2. Cleaning and Sanitizing Instructions .......................................................................... 65
[a] Cleaning Solution ................................................................................................ 65
[b] Cleaning Procedure ............................................................................................ 65
[c] Sanitizing Solution............................................................................................... 66
[d] Sanitizing Procedure - Initial................................................................................ 66
[e] Sanitizing Procedure - Final ................................................................................ 67
3. Maintenance Instructions ............................................................................................ 69
4

I. Specifications

1. Icemaker

F-1500MAH

AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 9.8 RLA 56 LRA GEAR MOTOR 120 V 5.6 FLA 1/2 HP FAN MOTOR 115 V 0.85FLA 1/15 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *1590 (721) 1514 (687) 1447 (656) Reference without *marks 80 1382(627) 1321 (599) 1262 (572)
90 1206 (547) *1170 (531) 1100 (499)
100 1051 (477) 1005 (456) *945 (429) SHAPE OF ICE Flake ICE QUALITY Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 1863 (3.83) 1820 (2.74) POTABLE WATER 140 (12) 191 (12) gal./24HR (gal./100 lbs.) EXTERIOR DIMENSIONS (W xDxH) 30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT, appoximate Net 300 lbs. ( 136 kg ), Shipping 325 lbs. ( 148 kg ) CONNECTIONS - ELECTRIC Permanent - Connect ion
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/2 HP Gear Motor ) ICE MA KING W ATER CONTROL Float Switch COOLING W ATER CONTROL N/A BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermet ic, Model CS10K6E-PFV CONDENSER Air-cooled, Fin and tube type EVAPORATOR Copper Tube on Cylinder REFRIGERANT CONTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 2 lb.5oz. (1050g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay COMPRESSOR PROTECTION Internal Protector GEAR MOTOR PROTECTION Circuit Protector (10A) REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch LOW WATER PROTECTION Float Switch and Timer ACCESSORIES -SUPPLIED Spare Fuse
-REQUIRED Ice Storage Bin OPERATING CONDITIONS VOLTAGE RANGE 187-253 V
AMBIENT TEMP. 45-100° F WATER SUPPLY TEMP. 45-90° F WATER SUPPLY PRESSURE 10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
5

F-1500MAH-C

AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMP RESSOR 240 V 9.8 RLA 56 LRA GEAR MOTOR 120 V 5.6 FLA 1/2 HP FAN MOTOR 115 V 0.85FLA 1/15 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 1300 (590) 1245 (565) 1194 (542) Reference without *marks 80 1145(520) 1099 (498) 1054 (478)
90 1011 (458) 990 (449) 930 (422)
100 892 (404) 855 (388) 800 (363) SHAPE OF ICE Cubelet ICE QUALITY Approx. 70% , Ice (90/70°F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELE CTRIC & WA TER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 1863 (4.5) 1820 (3.36) POTABLE WATER 119 (12) 156 (12) gal./24HR (gal./100 lbs.) EXTERIOR DIMENSIONS (W xDxH) 30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT, appoximate Net 300 lbs. ( 136 kg ), Shipping 325 lbs. ( 148 kg ) CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/2 HP Gear Motor ) ICE MAKING WATER CONTROL Float Switch COOLING W ATER CONTROL N/A BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model CS10K6E-PFV CONDENSER Air-cooled, Fin and tube type EVAPORATOR Copper Tube on Cylinder REFRIGERANT CONTROL Thermos tat ic Expansion Valve REFRIGERANT CHARGE R-404A, 2 lb.5oz. (1050g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG P.C. BOARD CIRCUIT PROTECTION High V oltage Cut-off Relay COMPRESSOR PROTECTION Internal Protector GEAR MOTOR PROTECTION Circuit Protector (10A) REFRIGERANT CIRCUIT PROTECTION Auto-res et High Pressure Control Switch LOW WATER PROTECTION Float Switch and Timer ACCESSORIES -SUPPLIED Spare Fuse
-REQUIRED Ice Storage Bin OPERATING CONDITIONS VOLTAGE RANGE 187-253 V
AMBIENT TEMP. 45-100° F WATER SUPPLY TEMP. 45-90° F WATER SUPPLY PRESSURE 10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
6

F-1500MWH

AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 9.8 RLA 56 LRA GEAR MOTOR 120 V 5.6 FLA 1/2 HP FAN MOTOR 115 V 0.51A 8W OTHER 120 V 0.03A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/ day ) 70 *1435 (652) 1390(632) 1360(618) Reference without *marks 80 1335(607) 1310(595) 1285(584)
90 1260(573) *1245 (566) 1210(546)
100 1185(539) 1160(527) *1075 (489) SHAPE OF ICE Flake ICE QUALITY Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 1780(3.4) 1792(3.0) POTABLE WATER 149 (12) 172 (12) WAER COOLED CONDENSER 675 (54) 435 (30) gal./24HR (gal./100 lbs.) EXTERIOR DIMENSIONS (Wx DxH) 30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm) EXTERIOR FINISH Stainless Steel, Galvanized St eel (Rear) WEIGHT, approximate Net 300 lbs. ( 136 kg ), Shipping 325 lbs. ( 148 kg ) CONNECTIONS - ELECTRIC P ermanent - Connection
- WATER SUPPLY Inlet 1/2" FPT Cond. Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT Cond. Outlet 3/8" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/2 HP Gear Motor ) ICE MA KING W ATER CONTROL Float Switch COOLING WATER CONTROL N/ A BIN CONTROL SYSTEM Mechanic al Bin Control ( Prox imity Sw. ) COMPRESSOR Hermetic, Model CS10K6E -PFV CONDENSER Water-cooled, Tube in tube type EVAPORATOR Copper Tube on Cylinder REFRIGERANT CONTROL Thermostat ic Expansion Valve REFRIGERANT CHARGE R-404A, 1 lb.4oz . (575g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay COMPRESSOR PROTECTION Internal Protector GEAR MOTOR PROTECTION Circuit Protector (10A) REFRIGERANT CIRCUIT PROTE CTION A uto-reset High Pressure Control Switch LOW WATER PROTECTION Float Switch and Timer ACCESSORIES -SUPPLIED Spare Fuse
-REQUIRED Ice Storage Bin OPERATING CONDITIONS VOLTAGE RANGE 187-253 V
AMBIENT TEMP. 45-100° F WATER SUPPLY TEMP. 45-90° F WATER SUPPLY PRESSURE 10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
7

F-1500MWH-C

AC SUPPLY V OLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 9.8 RLA 56 LRA GEAR MOTOR 120 V 5.6 FLA 1/2 HP FAN MOTOR 115 V 0.51A 8W OTHER 120 V 0.03A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAK ER (USA ONLY ) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *1125 (511) 1075 (488) 1060 (482) Reference without *marks 80 1050 (477) 1040 (470) 1025 (465)
90 1015 (460) *975 (443) 990 (449)
100 980 (445) 970 (439) *905 (411) SHAPE OF ICE Cubelet ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELE CTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 1756 (4.3) 1852 (4.0) POTABLE WATER 116.57 (12) 135 (12) WATER-COOLED CONDENSER 632 (65) 435 (39) gal./24HR (gal./100 lbs.) EXTERIOR DIMENSIONS (W xDxH) 30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm) EXTERIOR FINISH Stainless St eel, Galvanized Steel (Rear) WEIGHT, approximate Net 300 lbs. ( 132 kg ), S hipping 325 lbs. ( 143 k g ) CONNECTIONS - ELECTRIC Permanent - Connection
- W ATER SUPPLY Inlet 1/2" FPT Cond. Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT Cond. Outlet 3/8" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/2 HP Gear Motor ) ICE MAKING WATER CONTROL Float Switch COOLING WATER CONTROL N/A BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model CS10K6E-PFV CONDENSER Air-c ooled Remote Condenser Unit URC-12F Recommended EVAPORATOR Copper Tube on Cylinder REFRIGERANT CONTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 1 lb. 4oz. (575g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG P.C. BOARD CIRCUIT PROTECTION High Volt age Cut-off Relay COMPRESSOR PROTECTION Internal Protector GEAR MOTOR PROTECTION Circuit Protector (10A) REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch LOW WATER PROTECTION Float Switch and Timer ACCESSORIES -SUPPLIED Spare Fuse
-REQUIRED Ice Storage Bin OPERATING CONDITIONS VOLTAGE RANGE 187-253 V
AMBIENT TEMP. 45-100° F WATER SUPPLY TEMP. 45-90° F WATER SUPPLY PRESSURE 10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
8

F-1500MRH

AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 9.8 RLA 56 LRA GEAR MOTOR 120 V 5.6 FLA 1/2 HP FAN MOTOR 115 V 3A MAX
0.51A 8W OTHER 120 V 0.03A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *1585 (720) 1532(695) 1484(673) Reference without *marks 80 1439(653) 1394(632) 1351(613)
90 1309(594) *1300 (590) 1230(558)
100 1192(541) 1155(524) *1070 (485) SHAPE OF ICE Flake ICE QUALITY Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CONSUMP TION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2015(3.72) 2010 (3.01) POTABLE WATER 156 (12) 190 (12) gal./24HR (gal./100 lbs.) EXTERIOR DIMENSIONS (WxDxH) 30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT, appoximate Net 290 lbs. ( 132 kg ), Shipping 315 lbs. ( 143 kg ) CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/2 HP Gear Motor ) ICE MAKING W ATER CONTROL Float Switch COOLING WATER CONTROL N/A BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model CS10K6E-PFV CONDENSER Air-cooled Remote Condenser Unit URC-12F Recommended. EVAPORATOR Copper Tube on Cylinder REFRIGERANT CONTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 9 lb.9oz. (4350g)
(Ice Maker: 5lb. 2oz., Cond. Unit: 4lb. 7oz.) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG P. C. B OARD CIRCUIT PROTECTION High Voltage Cut-off Relay COMPRESSOR PROTECTION Internal Protector GEAR MOTOR PROTECTION Circuit Protector (10A) REFRIGERANT CIRCUIT PROTECTION A uto-reset High Pressure Control Switch LOW WATER PROTECTION Float Swit ch and Timer ACCESSORIES -SUPPLIED Spare Fuse
-REQUIRED Ice Storage Bin OPERATING CONDITIONS VOLTAGE RANGE 187-253 V
AMBIENT TEMP. 45-100° F
WATER SUPPLY TEMP. 45-90° F
WATER SUPPLY PRESSURE 10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
9

F-1500MRH-C

AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 9.8 RLA 56 LRA GEAR MOTOR 120 V 5.6 FLA 1/2 HP FAN MOTOR 115 V 3A MAX
0.51A 8W OTHER 120 V 0.03A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *1335 (606) 1294 (587) 1258 (571) Reference without *marks 80 1223 (555) 1188 (539) 1155 (524)
90 1123 (509) *1120 (508) 1060 (481)
100 1031 (468) 1002 (454) *925 (420) SHAPE OF ICE Cubelet ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CONSUMP TION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 1949 (4.18) 1947 (3.50) POTABLE WATER 134 (12) 160 (12) gal./24HR (gal./100 lbs.) EXTERIOR DIMENSIONS (WxDxH) 30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT, appoximate Net 290 lbs. ( 132 kg ), Shipping 315 lbs. ( 143 kg ) CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT ICE MAKING SYSTEM Auger type HARV ESTING SYSTEM Direct Driven Auger ( 1/ 2 HP Gear Motor ) ICE MAKING W ATER CONTROL Float Switch COOLING WATER CONTROL N/A BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model CS10K6E-PFV CONDENSER Air-cooled Remote Condenser Unit URC-12F Recommended EVAPORATOR Copper Tube on Cylinder REFRIGERANT CONTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 9 lb.9oz. (4350g)
(Ice Maker: 5lb. 2oz., Cond. Unit: 4lb. 7oz.) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG P. C. B OARD CIRCUIT PROTECTION High Voltage Cut-off Relay COMPRESSOR PROTECTION Internal Protector GEAR MOTOR PROTECTION Circuit Protector (10A) REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch LOW WATER PROTECTION Float Switch and Timer ACCE SSORIES -SUPPLIED Spare Fuse
-REQUIRED Ice Storage Bin OPERATING CONDITIONS VOLTAGE RANGE 187-253 V
AMBIENT TEMP. 45-100° F
WATER SUPPLY TEMP. 45-90° F
WATER SUPPLY PRESSURE 10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
10

2. Condenser Unit

URC-12F

11
SPECIFICATIONS
MODEL: URC-12F
AC SUPPLY VOLTAGE 115/60/1 (Connection to Icemaker)
FAN MOTOR (QTY. 2) 115 V Total 2.6FLA 130W
EXTERIOR DIMENSIONS (WxDxH) 35-11/16" x 15-11/16" x 21-15/16" (907.2 x 398 x 557.8 mm)
DIMENSIONS INCLUDING LEGS (WxDxH) 37-13/16" x 18-1/8" x 36-15/16" (960 x 460 x 937.8 mm)
EXTERIOR FINISH Galvanized Steel
WEIGHT Net 80 lbs. ( 36 kg ) Shipping 115 lbs. ( 52 kg )
CONNECTIONS - ELECTRIC Permanent - Connection
- REFRIGERATION Discharge Line 1-1/16-12 UNF Fitting (#10 AEROQUIP)
Liquid Line 5/8-18 UNF Fitting (#6 AEROQUIP)
CONDENSER Air-cooled, Fin and tube type
FAN MOTOR PROTECTION Thermal Protection
REFRIGERANT CONTROL Condensing Pressure Regulator
REFRIGERANT CHARGE R-404A 4 lbs. 7oz. (2000g)
DESIGN PRESSURE High 467 PSIG
OPERATING CONDITIONS VOLTAGE RANGE 104 ~ 127 V
AMBIENT TEMP. -20 ~ 122 °F
ACCESSORIES -SUPPLIED Leg 2 pcs
Hex. Head Bolt w/Washer 8 x 16 8 pcs
Hex. Nut 8 8 pcs
We reserve the right to make changes in specifications and design without prior notice.
12

II. General Information

1. Construction

F-1500MAH(-C)

Control Water Valve
Evaporator
Gear Motor
Water Supply Inlet
Ice Chute
Fan Motor
Condenser
Compressor
Junction Box
Expansion Valve
Flush Water Valve
Drier
Bin Control
Control Box
13

F-1500MWH(-C)

Control Water Valve
Evaporator
Water Supply Inlet
Ice Chute
Water Regulator
Condenser
Gear Motor
Junction Box
Expansion Valve
Compressor
Drier
Bin Control
Control Box
Flush Water Valve
14

F-1500MRH(-C)

Control Water Valve
Evaporator
Gear Motor
Water Supply Inlet
Ice Chute
Receiver Tank
Compressor
Drier
Junction Box
Expansion Valve
Flush Water Valve
Bin Control
Control Box
15

2. Control Box Layout

F-1500MAH(-C)

A 12P Plug Housing L Starting Capacitor
B Cam Timer M Timer Board
C Relay N Rocker Switch
D Transformer O 4P Plug Housing
E Circuit Protect Relay P Toggle Switch
F Water Control Relay Q 6P Plug Housing
G Ge ar Motor Protect Relay R Fuse
H Spout Control Relay S 3P Plug Housing
I Starter T 4P Plug Housing
J Capacitor U Protector
K Run Capacitor V Spout Indicator
W Capacitor
Note: The above component names are identical with the Wiring Label, but not with
the Parts List.
16

F-1500MWH(-C), F-1500MRH(-C)

A 12P Plug Housing L Starting Capacitor
B Cam Timer M Timer Board
C Relay N Rocker Switch
D Transformer O 4P Plug Housing
E Circuit Protect Relay P Toggle Switch
F Water Control Relay Q 6P Plug Housing
G Ge ar Motor Prote ct Re lay R Fuse
H Spout Control Relay S 3P Plug Housing
I Starter T 4P Plug Housing
J Capacitor U Protector
K Run Capacitor V Spout Indicator
17

III. Technical Information

1. Water Circuit and Refrigeration Circuit

F-1500MAH(-C)

18

F-1500MWH(-C)

19

F-1500MRH(-C)

20

2. Wiring Diagrams

F-1500MAH(-C)

21
Loading...