Only qualied service technicians should install and service the appliance. To
obtain the name and phone number of your local Hoshizaki Certied Service
Representative, visit www.hoshizaki.com. No installation or service should be
undertaken until the technician has thoroughly read this Instruction Manual.
Likewise, the owner/manager should not proceed to operate the appliance until the
installer has instructed them on its proper operation. Failure to install, operate, and
maintain the appliance in accordance with this manual will adversely affect safety,
performance, component life, and warranty coverage and may result in costly water
damage. Proper installation is the responsibility of the installer. Product failure or
property damage due to improper installation is not covered under warranty.
Hoshizaki provides this manual primarily to assist qualied service technicians in the
installation, maintenance, and service of the appliance.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call, send an e-mail message, or write to the Hoshizaki Technical
Support Department for assistance.
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: Hoshizaki Technical Support Department
NOTE: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem.
2
IMPORTANT
This manual should be read carefully before the appliance is installed and operated.
Read the warnings and guidelines contained in this manual carefully as they
provide essential information for the continued safe use and maintenance of the
appliance. Retain this manual for any further reference that may be necessary.
CONTENTS
Important Safety Information ................................................................................................. 4
I. Specications ...................................................................................................................... 6
A. Electrical and Refrigerant Data ..................................................................................... 6
2. Line Set ................................................................................................................. 15
3. Line Set Installation ............................................................................................... 16
F. Electrical Connection ................................................................................................... 18
G. Water Supply and Drain Connections ......................................................................... 21
H. Final Checklist ............................................................................................................. 23
I. Startup .......................................................................................................................... 24
III. Maintenance ................................................................................................................... 25
A. Maintenance Schedule ................................................................................................ 25
B. Cleaning and Sanitizing Instructions ........................................................................... 26
IV. Preparing the Icemaker for Periods of Non-Use ............................................................. 30
V. Disposal ........................................................................................................................... 31
3
Important Safety Information
Throughout this manual, notices appear to bring your attention to situations which could
result in death, serious injury, damage to the appliance, or damage to property.
WARNING Indicates a hazardous situation which could result in death or
serious injury.
NOTICE Indicates a situation which could result in damage to the
appliance or property.
IMPORTANT Indicates important information about the installation, use, and
care of the appliance.
WARNING
This appliance should be destined only to the use for which it has been expressly
conceived. Any other use should be considered improper and therefore dangerous.
The manufacturer cannot be held responsible for injury or damage resulting
from improper, incorrect, and unreasonable use. Failure to install, operate, and
maintain the appliance in accordance with this manual will adversely affect safety,
performance, component life, and warranty coverage and may result in costly water
damage.
To reduce the risk of death, electric shock, serious injury, or re, follow basic
precautions including the following:
• Only qualied service technicians should install and service the appliance.
• The appliance must be installed in accordance with applicable national, state, and
local codes and regulations.
• To reduce the risk of electric shock, do not touch the control switch with damp
hands.
• Move the control switch to the "OFF" position and turn off the power supply to
the remote condensing unit before servicing. Place the icemaker disconnect
(ifapplicable) in the "OFF" position. Lockout/Tagout to prevent the power supply
from being turned back on inadvertently.
• Do not make any alterations to the appliance. Alterations could result in electric
shock, injury, re, or damage to the appliance.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory, or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
• Children should be properly supervised around this appliance.
• Do not climb, stand, or hang on the appliance or allow children or animals to do so.
Serious injury could occur or the appliance could be damaged.
• Do not use combustible spray or place volatile or ammable substances near the
appliance. They might catch re.
• Keep the area around the appliance clean. Dirt, dust, or insects in the appliance
could cause harm to individuals or damage to the appliance.
4
WARNING, continued
Icemaker
• Do not connect the icemaker to an external power source. Icemaker power supply
and ground connection are supplied from the remote condensing unit via the wire
bundle provided with the remote condensing unit.
• Wire bundle routing (conduit) and disconnect (if required) must meet national, state,
and local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, re, or damage.
• THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the icemaker
could result in death or serious injury.
Remote Condensing Unit
• Remote condensing unit electrical connection must be hard-wired and must meet
national, state, and local electrical code requirements. Failure to meet these code
requirements could result in death, electric shock, serious injury, re, or damage.
• The remote condensing unit requires an independent power supply of proper
capacity. See the nameplate for electrical specications. Failure to use an
independent power supply of proper capacity can result in a tripped breaker, blown
fuse, damage to existing wiring, or component failure. This could lead to heat
generation or re.
• THE REMOTE CONDENSING UNIT MUST BE GROUNDED. Failure to properly
ground the remote condensing unit could result in death or serious injury.
NOTICE
• Follow the water supply, drain connection, and maintenance instructions carefully to
reduce the risk of costly water damage.
• In areas where water damage is a concern, install in a contained area with a oor
drain.
• Install the icemaker in a location that stays above freezing. Normal operating
ambient temperature must be within 45°F to 100°F (7°C to 38°C).
• Do not leave the icemaker on during extended periods of non-use, extended
absences, or in sub-freezing temperatures. To properly prepare the icemaker for
these occasions, follow the instructions in "IV. Preparing the Icemaker for Periods of
Non-Use."
• Do not place objects on top of the appliance.
• The dispenser unit/ice storage bin is for ice use only. Do not store anything else in
the dispenser unit/ice storage bin.
5
I. Specications
A. Electrical and Refrigerant Data
The rating label (KMS) and nameplate (KMS and SRK) provide electrical and refrigerant
data. The rating label can be seen by removing the front panel. The nameplate is located
on the rear panel of the icemaker and on the side panel of the remote condensing unit.
Forcertication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. KMS-822MLH
Model NumberKMS-822MLH
AC Supply Voltage115-120/60/1
Pump120V 1.2FLA 60W
Other115V 0.8A
Design PressureHI-467PSI LO-230PSI
Total Refrigerant
Charge
2. SRK-10H
404A
Total Refrigerant Charge
with Hoshizaki Remote
Condensing Unit
SRK-10H: 15 LB.
Note: Legs are included with remote condensing unit.
8
II. Installation and Operating Instructions
WARNING
• The icemaker and remote condensing unit must be installed in accordance with
applicable national, state, and local codes and regulations.
• Failure to install, operate, and maintain the appliance in accordance with this
manual will adversely affect safety, performance, component life, and warranty
coverage and may result in costly water damage.
• CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews
are securely in place after installation. Make sure that none have fallen into the
dispenser unit/ice storage bin.
A. Location
1. Icemaker
NOTICE
• This icemaker is not intended for outdoor use. Normal operating ambient
temperature must be within 45°F to 100°F (7°C to 38°C); Normal operating
water temperature must be within 45°F to 90°F (7°C to 32°C). Operation of the
icemaker, for extended periods, outside of these normal temperature ranges may
affect icemaker performance.
• This icemaker will not work at sub-freezing temperatures. To prevent damage
to the water supply line, drain the icemaker if the air temperature is going to go
below 32°F (0°C). See "IV. Preparing the Icemaker for Periods of Non-Use."
• The icemaker should not be located next to ovens, grills, or other high heat producing
equipment.
• Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of
maintenance and/or service should they be required.
• The location must provide a rm and level foundation for the equipment.
9
2. Remote Condensing Unit
NOTICE
• The remote condensing unit is intended for outdoor use. Normal operating ambient
temperature must be within -20°F to 122°F (-29°C to 50°C). Operation of the
remote condensing unit, for extended periods, outside of this normal temperature
range may affect performance.
• The maximum line set length is 66' (20 m). No refrigerant charge adjustment is
necessary.
• The maximum vertical distance between the remote condensing unit and icemaker
is 33' (10 m) above or 10' (3 m) below the icemaker. These distances are measured
tting to tting. See Fig. 1.
• If the vertical distance between the remote condensing unit and the icemaker
is greater than 20' (6 m) (not to exceed 33' (10 m)), an "S" oil-trap (5/8"OD
copper tubing) must be installed in the suction line. The "S" oil-trap must be
located halfway between the icemaker and remote condensing unit. This ensures
sufficient oil return to the compressor.
The remote condensing unit must be positioned in a permanent site under the following
guidelines:
• A rm and at site.
• A dry and well ventilated area with 24" (61 cm) clearance in both front and rear for proper
air circulation and ease of maintenance and/or service should they be required. See Fig. 2.
Remote
Condensing
Unit
Suction Line
"S" Oil-Trap
Icemaker
Ice Storage
Bin
Max.
16.5
Feet
Max.
33
Feet
Max.
16.5
Feet
Service Loop
Fig. 1
Icemaker
Ice Storage
Bin
Remote
Condensing
Unit
Service Loop
Max.
10
Feet
Min. 24" (61 cm) Clearance
24"
(61 cm)
Air
Fig. 2
24"
(61 cm)
Air
10
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.