Hoshizaki KML-400MAE, KML-400MWE Operator’s Manual

ISSUED:
APRIL 4, 1997
HOSHIZAKI
MODULAR CRESCENT CUBER
MODEL
KML-400MAE
KML-400MWE
INSTRUCTION MANUAL
FOREWORD
IMPORTANT
Only qualified service technicians should attempt to install, service or maintain this icemaker. No such installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the installation, maintenance and service of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily ad­dressed, please call or write to the HOSHIZAKI Care Department for assistance.
HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City, GA 30269
Attn: HOSHIZAKI Care Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: (770) 487-3360
NOTE: To expedite assistance, all correspondence/communication MUST include the following
information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem
A1BA10A9704
• Please review this manual. It should be read carefully before the icemaker is installed and operated. Only qualified service technicians should install, service and maintain the icemaker. This manual should be made available to the technician prior to installation, maintenance or service.
• Keep this manual with the icemaker for later reference.
CONTENTS
PAGE
I. SPECIFICATIONS..................................................................................................... 4
1. NAMEPLATE RATING ............................................................................................ 4
[a] KML-400MAE (Air-cooled).................................................................................. 4
[b] KML-400MWE (Water-cooled)............................................................................ 5
2. DIMENSIONS/CONNECTIONS............................................................................... 6
[a] KML-400MAE..................................................................................................... 6
[b] KML-400MWE .................................................................................................... 7
II. INSTALLATION AND OPERATING INSTRUCTIONS.............................................. 8
1. CHECKS BEFORE INSTALLATION ....................................................................... 8
2. HOW TO REMOVE PANELS .................................................................................. 8
3. LOCATION .............................................................................................................. 9
4. SET UP ................................................................................................................... 9
5. ELECTRICAL CONNECTION................................................................................ 10
6. WATER SUPPLY AND DRAIN CONNECTIONS................................................... 11
7. FINAL CHECK LIST .............................................................................................. 13
8. START UP............................................................................................................. 14
9. PREPARING THE ICEMAKER FOR LONG STORAGE ....................................... 15
III. MAINTENANCE AND CLEANING INSTRUCTIONS ............................................. 17
1. CLEANING INSTRUCTIONS ................................................................................ 17
[a] CLEANING PROCEDURE............................................................................... 17
[b] SANITIZING PROCEDURE............................................................................. 19
2. MAINTENANCE .................................................................................................... 20
A1BA10A9704
I. SPECIFICATIONS
1. NAMEPLATE RATING
[a] KML-400MAE (Air-cooled)
MODEL NUMBER SERIAL NUMBER AC SUPPLY VOLTAGE COMPRESSOR PUMP 120V FAN OTHER MAXIMUM FUSE SIZE MAX. HACR BREAKER (USA ONLY) MAX. CIRC. BREAKER (CANADA ONLY) MINIMUM CIRCUIT AMPACITY DESIGN PRESSURE REFRIGERANT 22 MOTOR-COMPRESSOR THERMALLY PROTECTED NOT INTENDED FOR OUTDOOR USE
115-120V 11.5RLA 75LRA
0.6 FLA 14W 120V 1 FLA 30W 115-120V 0.15A
HI-427PSI LO-206PSI
KML-400MAE
115-120/60/1
20AMPS 20AMPS 20AMPS 20AMPS
1 lb. 5 oz.
See the Nameplate for electrical and refrigeration speci­fications. This Nameplate is located on the upper right hand side of the rear panel. Since this Nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specifications and design without prior notice.
A1BA10A9704
[b] KML-400MWE (Water-cooled)
MODEL NUMBER SERIAL NUMBER AC SUPPLY VOLTAGE COMPRESSOR PUMP FAN OTHER MAXIMUM FUSE SIZE MAX. HACR BREAKER (USA ONLY) MAX. CIRC. BREAKER (CANADA ONLY) MINIMUM CIRCUIT AMPACITY DESIGN PRESSURE REFRIGERANT 22 MOTOR-COMPRESSOR THERMALLY PROTECTED NOT INTENDED FOR OUTDOOR USE
115-120V 11RLA 75LRA 120V 0.6 FLA 14W 120V 0.3 FLA 4W 115-120V 0.15A
HI-395PSI LO-206PSI
KML-400MWE
115-120/60/1
20AMPS 20AMPS 20AMPS 20AMPS
15 oz.
See the Nameplate for electrical and refrigeration speci­fications. This Nameplate is located on the upper right hand side of rear panel. Since this Nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specifications and design without prior notice.
A1BA10A9704
2. DIMENSIONS/CONNECTIONS
[a] KML-400MAE
Unit: inches (mm.)
A1BA10A9704
[b] KML-400MWE
Unit: inches (mm.)
A1BA10A9704
Loading...