Only qualied service technicians should install, service, and maintain the
icemaker. No service or maintenance should be undertaken until the technician
has thoroughly read this Service Manual. Failure to service and maintain
the equipment in accordance with this manual may adversely affect safety,
performance, component life, and warranty coverage.
Hoshizaki provides this manual primarily to assist qualied service technicians in the
service and maintenance of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call, write, or send an e-mail message to the Hoshizaki Technical
Support Department for assistance.
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
This manual should be read carefully before the icemaker is serviced or
maintenance operations are performed. Only qualied service technicians
should install, service, and maintain the icemaker. Read the warnings contained
in this booklet carefully as they give important information regarding safety.
Please retain this booklet for any further reference that may be necessary.
CONTENTS
Important Safety Information ................................................................................................. 5
I. Specications ...................................................................................................................... 6
A. Icemaker ....................................................................................................................... 6
B. Condenser Unit ........................................................................................................... 16
II. General Information ......................................................................................................... 18
A. Construction ................................................................................................................ 18
B. Sequence of Operation ............................................................................................... 21
1. Sequence Cycles and Shutdown .......................................................................... 21
a) KM-1601SAH/3 "G" Control Board ................................................................... 21
b) KM-1601SWH/3 and KM-1601SRH/3 "E" Control Board .................................. 23
2. Sanitizing Procedure - Following Cleaning Procedure ............................................74
B. Maintenance ................................................................................................................ 75
C. Preparing the Icemaker for Long Storage ................................................................... 75
4
Important Safety Information
Throughout this manual, notices appear to bring your attention to situations which could
result in death, serious injury, or damage to the unit.
WARNING Indicates a hazardous situation which could result in death or
serious injury.
CAUTION Indicates a situation which could result in damage to the unit.
IMPORTANT Indicates important information about the use and care of the
unit.
WARNING
This icemaker should be destined only to the use for which it has been
expressly conceived. Any other use should be considered improper and
therefore dangerous. The manufacturer cannot be held responsible for injury or
damage resulting from improper, incorrect, and unreasonable use.
To reduce the risk of death, electric shock, serious injury, or re, follow
basic precautions including the following:
local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, re, or severe damage to
equipment.
proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse
can result in a tripped breaker, blown fuse, or damage to existing wiring. This
could lead to heat generation or re.
•THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the
icemaker could result in death or serious injury.
•THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power
supply and ground wire to the remote condenser unit are supplied from the
icemaker. Failure to properly ground the remote condenser unit could result
in death or serious injury.
supply to the icemaker before servicing the remote condenser unit.
Lockout/Tagout to prevent the power supply from being turned back on
inadvertently.
5
I. Specications
A. Icemaker
1. KM-1601SAH (air-cooled)
AC SUPPLY VOLTAGE208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE15.0 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1462 (663)1427 (647)1307 (593)
Reference without *marks801435 (651)1381 (627)1221 (554)
901427 (647)*1343 (609)1198 (543)
1001379 (625)1309 (594)1064 (483)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE31.4 lbs. (14.3 kg) 1440pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2630(4.70)2450(4.03)
WATER gal./24HR (gal./100 lbs.)228(17.0)709(48.5)
CEC/CEE TIER LEVEL2
ENERGY STARYES
EXTERIOR DIMENSIONS (WxDxH)48" x 27-3/8" x 27-3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 315 lbs. (143 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-PFV-237
CONDENSERAir-Cooled , Fin and tube type
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
REFRIGERANT CHARGER404A, 3 lb. 12.5 oz. (1715g)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Storage Bin
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
6
2. KM-1601SAH3 (air-cooled)
AC SUPPLY VOLTAGE208-230/60/3
AMPERAGE12.0 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1456 (660)1423 (646)1313 (596)
Reference without *marks801431 (649)1381 (626)1234 (560)
901423 (646)*1345 (610)1211 (549)
1001379 (626)1314 (596)1088 (494)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE32.5 lbs. (14.8 kg) 1440pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2610(4.65)2370(3.91)
WATER gal./24HR (gal./100 lbs.)249(18.5)708(48.6)
CEC/CEE TIER LEVEL3
ENERGY STARYES
EXTERIOR DIMENSIONS (WxDxH)48" x 27-3/8" x 27-3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 315 lbs. (143 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-TF5-237
CONDENSERAir-Cooled, Fin and tube type
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
REFRIGERANT CHARGER404A, 3 lb. 12.5 oz. (1715g)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Storage Bin
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
7
3. KM-1601SWH (water-cooled)
AC SUPPLY VOLTAGE208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE13.4 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1492 (677)1501 (681)1419 (643)
Reference without *marks801499 (680)1513 (686)1378 (625)
901501 (681)*1523 (691)1408 (639)
1001453 (659)1496 (679)1303 (591)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE30.2 lbs. (13.7 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2410(3.8)2300(3.7)
WATER gal./24HR (gal./100 lbs.)373(24.5)698(46.8)
WATER COOLED CONDENSER1493(98)930(62)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)48" x 27-3/8" x 27-3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 310 lbs. ( 141 kg ), Shipping 360 lbs. ( 163 kg )
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPTCondenser Inlet 1/2" FPT
- DRAINOutlet 3/4" FPTCondenser Outlet 3/8" FPT
3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLWater Regulating Valve
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-PFV-237
CONDENSERWater-cooled, Tube in tube type
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
REFRIGERANT CHARGER-404A, 3 lbs. 1 oz. ( 1400g )
DESIGN PRESSUREHigh 427PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Storage Bin
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
8
4. KM-1601SWH3 (water-cooled)
AC SUPPLY VOLTAGE208-230/60/3
AMPERAGE9.0 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1555 (705)1558 (707)1466 (665)
Reference without *marks801557 (706)1562 (708)1417 (643)
901558 (707)*1565 (710)1440 (653)
1001507 (684)1536 (697)1326 (601)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE30.2 lbs. (13.7 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2390(3.66)2270(3.5)
WATER gal./24HR (gal./100 lbs.)372(23.8)804(51.7)
WATER COOLED CONDENSER1565(100)910(59)
gal./24HR (gal./100 lbs.)
CEC/CEE TIER LEVEL2
ENERGY STARN/A
EXTERIOR DIMENSIONS (WxDxH)48" x 27-3/8" x 27-3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 310 lbs. ( 141 kg ), Shipping 360 lbs. ( 163 kg )
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPTCondenser Inlet 1/2" FPT
- DRAINOutlet 3/4" FPTCondenser Outlet 3/8" FPT
3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLWater Regulating Valve
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-TF5-237
CONDENSERWater-cooled, Tube in tube type
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
REFRIGERANT CHARGER-404A, 3 lbs. 1 oz. ( 1400g )
DESIGN PRESSUREHigh 427PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Storage Bin
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
9
5. KM-1601SRH with URC-21F (remote air-cooled) (auxiliary codes: R-0; R-1; some S-1)
This data applies to units with an 8 l/min water valve. The 8 l/min water valve is part
number 3U0111-02 and has J248-032 stamped on the side of the valve facing the rear of
the unit.
AC SUPPLY VOLTAGE208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1583 (718)1550 (703)1435 (651)
Reference without *marks801558 (707)1507 (684)1353 (614)
901550 (703)*1472 (668)1332 (604)
1001503 (682)1439 (653)1203 (546)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE29.4 lbs. (13.3 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2640(4.3)2440(3.7)
WATER gal./24HR (gal./100 lbs.)255(17.3)503(31.8)
EXTERIOR DIMENSIONS (WxDxH)48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-PFV
CONDENSERAir-Cooled Remote, Condenser Unit URC-21F
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
Condensing Pressure Regulator on URC-21F
REFRIGERANT CHARGER404A, 24 lb. 14.6 oz. (11300g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
10
6. KM-1601SRH with URC-21F (remote air-cooled) (auxiliary codes: some S-1; S-2 and
later)
This data applies to units with a 15 l/min or 11 l/min water valve. The 15 l/min water valve
is part number 3U0111-01 and has J248-030 stamped on the side of the valve facing the
rear of the unit. The 11 l/min water valve is either part number 4A1176-04 or 4A5251-04
and has the part number stamped on the side of the valve facing the front of the unit.
AC SUPPLY VOLTAGE208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1564 (709)1547 (702)1468 (666)
Reference without *marks801551 (703)1524 (691)1415 (642)
901547 (702)*1505 (683)1407 (638)
1001512 (686)1482 (672)1317 (597)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE31.2 lbs. (14.2 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2700(4.30)2610(4.00)
WATER gal./24HR (gal./100 lbs.)375(24.9)785(50.2)
CEC/CEE TIER LEVEL2
ENERGY STARYES
EXTERIOR DIMENSIONS (WxDxH)48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-PFV
CONDENSERAir-Cooled Remote, Condenser Unit URC-21F
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
Condensing Pressure Regulator on URC-21F
REFRIGERANT CHARGER404A, 24 lb. 14.6 oz. (11300g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
11
7. KM-1601SRH with URC-22F (remote air-cooled) (auxiliary codes: S-2 and later)
This data applies to units with an 11 l/min water valve. The 11 l/min water valve is either
part number 4A1176-04 or 4A5251-04 and has the part number stamped on the side of
the valve facing the front of the unit.
AC SUPPLY VOLTAGE208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1531 (694)1519 (689)1426 (647)
Reference without *marks801522 (690)1503 (682)1368 (620)
901519 (689)*1490 (676)1371 (622)
1001475 (669)1462 (663)1261 (572)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE31.6 lbs. (14.3 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2710(4.36)2560(4.01)
WATER gal./24HR (gal./100 lbs.)352(23.6)755(49.3)
CEC/CEE TIER LEVEL2
ENERGY STARYES
EXTERIOR DIMENSIONS (WxDxH)48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-PFV
CONDENSERAir-Cooled Remote, Condenser Unit URC-22F
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
Condensing Pressure Regulator on URC-22F
REFRIGERANT CHARGER404A, 22 lb. 14.8 oz. (10400g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 7 lb. 11.5 oz.)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
12
8. KM-1601SRH3 with URC-21F (remote air-cooled) (auxiliary codes: R-0; R-1; some S-1)
This data applies to units with an 8 l/min water valve. The 8 l/min water valve is part
number 3U0111-02 and has J248-032 stamped on the side of the valve facing the rear of
the unit.
AC SUPPLY VOLTAGE208-230/60/3
AMPERAGE7.9 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1596 (724)1556 (706)1436 (651)
Reference without *marks801565 (710)1503 (682)1347 (611)
901556 (706)*1459 (662)1316 (597)
1001510 (685)1426 (647)1184 (537)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE29.4 lbs. (13.3 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2580(4.3)2450(3.7)
WATER gal./24HR (gal./100 lbs.)261(17.9)504(31.6)
EXTERIOR DIMENSIONS (WxDxH)48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-TF5
CONDENSERAir-Cooled Remote, Condenser Unit URC-21F
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
Condensing Pressure Regulator on URC-21F
REFRIGERANT CHARGER404A, 24 lb. 14.6 oz. (11300g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
13
9. KM-1601SRH3 with URC-21F (remote air-cooled) (auxiliary codes: some S-1; S-2 and
later)
This data applies to units with a 15 l/min or 11 l/min water valve. The 15 l/min water valve
is part number 3U0111-01 and has J248-030 stamped on the side of the valve facing the
rear of the unit. The 11 l/min water valve is either part number 4A1176-04 or 4A5251-04
and has the part number stamped on the side of the valve facing the front of the unit.
AC SUPPLY VOLTAGE208-230/60/3
AMPERAGE7.9 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1585 (719)1563 (709)1464 (664)
Reference without *marks801568 (711)1535 (696)1396 (633)
901563 (709)*1511 (685)1387 (629)
1001520 (689)1482 (672)1273 (577)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE31.2 lbs. (14.2 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2960(4.70)2580(3.90)
WATER gal./24HR (gal./100 lbs.)363(24.0)781(49.3)
CEC/CEE TIER LEVEL1
ENERGY STARNO
EXTERIOR DIMENSIONS (WxDxH)48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-TF5
CONDENSERAir-Cooled Remote, Condenser Unit URC-21F
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
Condensing Pressure Regulator on URC-21F
REFRIGERANT CHARGER404A, 24 lb. 14.6 oz. (11300g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
14
10. KM-1601SRH3 with URC-22F (remote air-cooled) (auxiliary codes: S-2 and later)
This data applies to units with an 11 l/min water valve. The 11 l/min water valve is either
part number 4A1176-04 or 4A5251-04 and has the part number stamped on the side of
the valve facing the front of the unit.
AC SUPPLY VOLTAGE208-230/60/3
AMPERAGE7.9 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY20 A
MAXIMUM FUSE SIZE20 A
APPROXIMATE ICE PRODUCTIONAmbientWATER TEMP. (°F)
PER 24 HR.Temp.(°F)507090
lbs./day ( kg/day )70*1530 (694)1521 (690)1414 (641)
Reference without *marks801523 (691)1508 (684)1349 (612)
901521 (690)*1498 (679)1359 (616)
1001468 (666)1465 (665)1231 (558)
SHAPE OF ICECrescent Cube
ICE PRODUCTION PER CYCLE32.1 lbs. (14.6 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITYN/A
ELECTRIC & WATER CONSUMPTION90/70°F70/50°F
ELECTRIC W (kWH/100 lbs.)2780(4.46)2490(3.90)
WATER gal./24HR (gal./100 lbs.)348(23.2)704(46.0)
CEC/CEE TIER LEVEL2
ENERGY STARYES
EXTERIOR DIMENSIONS (WxDxH)48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISHStainless Steel, Galvanized Steel (Rear)
WEIGHTNet 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRICPermanent - Connection
- WATER SUPPLYInlet 1/2" FPT
- DRAINOutlet 3/4" FPT
- CONDENSATE DRAIN3/8" OD Tube
CUBE CONTROL SYSTEMFloat Switch
HARVESTING CONTROL SYSTEMHot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROLTimer Controlled. Overflow Pipe
COOLING WATER CONTROLN/A
BIN CONTROL SYSTEMThermostat
COMPRESSORHermetic, Model CS18K6E-TF5
CONDENSERAir-Cooled Remote, Condenser Unit URC-22F
EVAPORATORVertical type, Stainless Steel and Copper
REFRIGERANT CONTROLThermostatic Expansion Valve
Condensing Pressure Regulator on URC-22F
REFRIGERANT CHARGER404A, 22 lb. 14.8 oz. (10400g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 7 lb. 11.5 oz.)
DESIGN PRESSUREHigh 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTIONHigh Voltage Cut-out ( Internal )
COMPRESSOR PROTECTIONAuto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTIONAuto-reset High Pressure Control Switch
LOW WATER PROTECTIONFloat Switch
ACCESSORIES -SUPPLIEDN/A
-REQUIREDIce Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONSVOLTAGE RANGE187 - 253 V
AMBIENT TEMP.45 -100° F
WATER SUPPLY TEMP.45 - 90° F
WATER SUPPLY PRESSURE10 - 113 PSIG
Note: We reserve the right to make changes in specications and design without prior
notice.
15
B. Condenser Unit
1. URC-21F
AC SUPPLY VOLTAGE115/60/1 (Connection to Icemaker)
FAN MOTOR 115 VTotal 2.6FLA130W
EXTERIOR DIMENSIONS (WxDxH)46-3/8" x 15-11/16" x 25-15/16" (1178 x 398 x 659 mm)
DIMENSIONS INCLUDING LEGS (WxDxH)48-7/16" x 18-1/8" x 40-7/8" (1230 x 460 x 1039 mm)
EXTERIOR FINISHGalvanized Steel
WEIGHTNet 158 lbs. ( 72 kg ) Shipping 169 lbs. ( 77 kg )
CONNECTIONS - ELECTRICPermanent - Connection
- REFRIGERANTDischarge Line 1-1/16"-12 UNF Fitting (#10 PARKER)
Liquid Line 5/8"-18 UNF Fitting (#6 PARKER)
CONDENSERAir-cooled, Fin and tube type
FAN MOTOR PROTECTIONThermal Protection
REFRIGERANT CONTROLCondensing Pressure Regulator
REFRIGERANT CHARGER-404A9 lb. 11oz.(4400g)
DESIGN PRESSUREHigh 467 PSIG32.2 Bar
OPERATING CONDITIONSVOLTAGE RANGE104 ~ 127 V
AMBIENT TEMP.-20 ~ 122 °F
ACCESSORIES -SUPPLIEDLeg2 pcs
Hex. Head Bolt w/Washer 8 x 168 pcs
Hex. Nut88 pcs
Note: We reserve the right to make changes in specications and design without prior
notice.
16
2. URC-22F
AC SUPPLY VOLTAGE115/60/1 (Connection to Icemaker)
FAN MOTOR 115 VTotal 2.6FLA130W
EXTERIOR DIMENSIONS (WxDxH)46-3/8" x 15-11/16" x 25-15/16" (1178 x 398 x 659 mm)
DIMENSIONS INCLUDING LEGS (WxDxH)48-7/16" x 18-1/8" x 40-7/8" (1230 x 460 x 1039 mm)
EXTERIOR FINISHGalvanized Steel
WEIGHTNet 134 lbs. (61 kg )Shipping 145 lbs. ( 66 kg )
CONNECTIONS - ELECTRICPermanent - Connection
- REFRIGERANTDischarge Line 1-1/16"-12 UNF Fitting (#10 PARKER)
Liquid Line 5/8"-18 UNF Fitting (#6 PARKER)
CONDENSERAir-cooled, Fin and tube type
FAN MOTOR PROTECTIONThermal Protection
REFRIGERANT CONTROLCondensing Pressure Regulator
REFRIGERANT CHARGER-404A7 lb. 11.5 oz. (3500g)
DESIGN PRESSUREHigh 467 PSIG32.2 Bar
OPERATING CONDITIONSVOLTAGE RANGE104 ~ 127 V
AMBIENT TEMP.-20 ~ 122 °F
ACCESSORIES -SUPPLIEDLeg2 pcs
Hex. Head Bolt w/Washer 8 x 168 pcs
Hex. Nut88 pcs
Note: We reserve the right to make changes in specications and design without prior
notice.
17
II. General Information
A. Construction
1. KM-1601SAH/3 (air-cooled)
Separators
Evaporator Assembly
Cube Guides
Pump-Out
Check Valve
Water Pump
(PM)
Float Switch
(F/S)
Inlet Water Valve
(WV)
Cleaning Valve
Compressor
(Comp)
Extension
Bracket
Spray Tubes
Control Switch
Bin Control Thermostat
(TBC)
Low-Side Service Valve
High-Side Service Valve
Thermostatic Expansion Valves
(TXV)
Water Supply Inlet
Junction Box
Hot Gas Valve
(HGV)
Check Valves
Air-Cooled
Condenser
Control Box
Fan Blade
Fan Motor
(FM)
Drier
Liquid Line Valve
(LLV)
Transformer Box
KM-1601SAH3
18
2. KM-1601SWH/3 (water-cooled)
Spray Tubes
Inlet Water Valve
(WV)
Evaporator Assembly
Cube Guides
Pump-Out
Check Valve
Water Pump
(PM)
Float Switch
(F/S)
Separators
Low-Side Service Valve
High-Side Service Valve
Thermostatic Expansion Valves
(TXV)
Water Supply Inlet
Junction Box
Hot Gas Valve
(HGV)
Check Valves
Water Regulating Valve
(WRV)
Water-Cooled
Condenser
Cleaning Valve
Compressor
(Comp)
Extension
Bracket
Bin Control Thermostat
(TBC)
19
Control Switch
Capacitor Box
(KM-1601SWH)
Transformer Box
(KM-1601SWH3)
Control Box
Drier
Liquid Line Valve
(LLV)
3. KM-1601SRH/3 (remote air-cooled)
Spray Tubes
Evaporator Assembly
Cleaning Valve
Pump-Out
Check Valve
Water Pump
(PM)
Float Switch
(F/S)
Compressor
(Comp)
Inlet Water Valve
(WV)
Low-Side Service Valve
Separators
High-Side Liquid Service Valve
High-Side Vapor Service Valve
Water Supply Inlet
Hot Gas Valve
(HGV)
Junction Boxes
Thermostatic Expansion Valves
(TXV)
Check Valves
Receiver
Control Box
Extension
Bracket
Control Switch
Bin Control Thermostat
(TBC)
Drier
Liquid Line Valve
(LLV)
Capacitor Box
(KM-1601SRH)
Transformer Box
(KM-1601SRH3)
20
B. Sequence of Operation
1. Sequence Cycles and Shutdown
a) KM-1601SAH/3 "G" Control Board
IMPORTANT
KM-1601SAH/3 utilize a "G" control board and TBC. For KM-1601SAH/3
operation, the K4 jumper (4A4883G01) must be in place on the control board
RED K4 connector or the unit will not operate.
The steps in the sequence are as outlined below. When power is supplied, CB red
"POWER OK" LED and green "BC CLOSED" LED turn on. If red "POWER OK" LED is
off, clear ice away from TBC bulb in the storage bin area. If yellow "BC OPEN" LED is
on, the unit will not start. In this case check that CB has the K4 jumper in place on CB
RED K4 connector. There is a 5-second delay before startup. Note that the order of the
component LEDs from the outer edge of CB is 1, 4, 3, 2.
(1) 1-Minute Fill Cycle
LED 4 is on. WV and X11 relay energize and the 1-minute ll cycle begins. After
1minute, CB checks for a closed F/S. If F/S is closed, the harvest cycle begins. If open,
WV remains energized through additional 1-minute ll cycles until water lls the water
tank and closes F/S. This serves as a low water safety to protect PM.
(2) Initial Harvest Cycle
LEDs 1, 4, and 2 are on. WV and X11 relay remain energized, Comp, FM, HGV, and
X10 relay energize. CB monitors the warming of the evaporator via the thermistor located
on the suction line. When the thermistor reaches 48°F (9°C), CB reads a 3.9 kΩ signal
from the thermistor and turns harvest termination over to the harvest timer (S4 dip switch
1 & 2). The harvest timer has settings of 60, 90, 120, and 180 seconds. For details, see
"II.C.3.b) Harvest Timer (S4 dip switch 1 & 2)." WV is energized during harvest for a
maximum of 6 minutes or the length of harvest minus 0 or 50 seconds (harvest pump
timer (S4 dip switch 7)), whichever is shorter. CAUTION! Do not adjust S4 dip switch
7 out of the factory default position on this model. Adjustment outside of the
factory default position may result in damage to the icemaker. LED4 turns off when
WV and X11 relay de-energize. LED 3 turns on and PM energizes and runs for the last
0 or 50 seconds of harvest depending on S4 dip switch 7 setting. This circulates water
over the evaporator for the last 0 or 50 seconds of harvest. PM is energized through
CB K1 ten-pin connector pin #5 (DBU wire) and the X10 relay. When the harvest timer
terminates, the harvest cycle is complete. CB checks the position of F/S and proceeds
to the freeze cycle if it is closed or calls for a 1-minute ll cycle if it is open. The minimum
total time allowed by CB for a complete harvest cycle is 2 minutes.
(3) Freeze Cycle
LED 1 is on. Comp and FM remain energized, PM energizes or remains energized
depending on harvest pump timer (S4 dip switch 7) setting. LLV energizes. HGV and
X10 relay de-energize. The unit is held in freeze by a 5-minute short cycle protection
timer (CB will not accept a signal from F/S during the rst 5 minutes of freeze). After the
5-minute short cycle protection timer terminates, CB turns freeze termination over to F/S.
As ice builds on the evaporator, the water level in the water tank lowers. The freeze cycle
21
continues until F/S opens and terminates the cycle. There is a 15 second delay before CB
acknowledges an open F/S.
(4) Pump-Out Cycle
LEDs 1, 3, and 2 are on. LED 4 is on when S4 dip switch 3 & 4 are set to 3 off and 4 on.
For details, see "II.C.3.c) Pump-Out Timer (S4 dip switch 3 & 4)." CAUTION! Do not
adjust S4 dip switch 3 & 4 to 3 off and 4 on. Adjustment to this position on this
model prevents the pump motor from rotating in the pump-out direction. Comp and
FM remain energized, HGV energizes, WV energizes if S4 dip switch 3 off and 4 on. LLV
de-energizes. PM stops for 2 seconds then reverses, taking water from the bottom of the
water tank and forcing pressure against the pump-out check valve seat allowing water to
go through the pump-out check valve and down the drain. At the same time, water ows
through the small tube to power ush F/S. When the pump-out timer terminates, pumpout is complete.
The rst pump-out occurs after the 11th freeze cycle, then every 10th cycle thereafter.
The pump-out frequency control is factory set, and generally no adjustment is required.
However, where water quality is bad and the icemaker needs a pump-out more often, the
pump-out frequency can be adjusted. The pump-out frequency control (S4 dip switch 5 &
6) can be set to have a pump-out occur every cycle, or every 2, 5, or 10 cycles. Timing of
the rst pump-out is dependent on S4 dip switch 5 & 6 settings. See the table below.
S4 Dip Switch Setting
No. 5No. 6
OFFOFFEvery cycleAfter 2nd freeze cycle
ONOFFEvery 2 cyclesAfter 3rd freeze cycle
OFFONEvery 5 cyclesAfter 6th freeze cycle
ONONEvery 10 cyclesAfter 11th freeze cycle
Pump-Out
Frequency
1st Pump-Out
(5) Harvest Cycle
Same as the initial harvest cycle. See "II.B.1.a)(2) Initial Harvest Cycle."
Note: Unit continues to cycle until TBC is satised or power is turned off. The unit always
restarts at the 1-minute ll cycle.
(6) Shutdown
When ice contacts TBC bulb (TBC open), TBC shuts down the unit within 10 seconds.
TBC is factory set, and generally no adjustment is required. However, adjustment may be
needed in some conditions, particularly at higher altitude locations.
gas valve; LLV –liquid line valve; PM–pump motor; TBC–thermostatic bin control;
WV–inlet water valve
22
b) KM-1601SWH/3 and KM-1601SRH/3 "E" Control Board
IMPORTANT
KM-1601SWH/3 and KM-1601SRH/3 utilize an "E" control board and TBC.
The steps in the sequence are as outlined below. When power is supplied, CB red
"POWER OK" LED turns on. There is a 5-second delay before startup. Note that the
order of the component LEDs from the outer edge of CB is 1, 4, 3, 2.
(1) 1-Minute Fill Cycle
LED 4 is on. WV energizes and the 1-minute ll cycle begins. After 1 minute, CB
checks for a closed F/S. If F/S is closed, the harvest cycle begins. If open, WV remains
energized through additional 1-minute ll cycles until water lls the water tank and closes
F/S. This serves as a low water safety to protect PM.
(2) Initial Harvest Cycle
LEDs 1, 4, and 2 are on. WV remains energized, Comp, FMR, HGV energize. CB
monitors the warming of the evaporator via the thermistor located on the suction line.
When the thermistor reaches 48°F (9°C), CB reads a 3.9 kΩ signal from the thermistor
and turns harvest termination over to the harvest timer (S4 dip switch 1 & 2). The harvest
timer has settings of 60, 90, 120, and 180 seconds. For details, see "II.C.3.b) Harvest
Timer (S4 dip switch 1 & 2)." WV is energized during harvest for a maximum of 6 minutes
or the length of harvest, whichever is shorter. LED 4 turns off when WV de-energizes.
When the harvest timer terminates, the harvest cycle is complete. CB checks the position
of F/S and proceeds to the next cycle if it is closed or calls for a 1-minute ll cycle if it is
open. The minimum total time allowed by CB for a complete harvest cycle is 2 minutes.
(3) Freeze Cycle
LED 1 is on. Comp and FMR remain energized, PM and LLV energize, HGV and WV
de-energize. The unit is held in freeze by a 5-minute short cycle protection timer (CB will
not accept a signal from F/S during the rst 5 minutes of freeze). After the 5-minute short
cycle protection timer terminates, CB turns freeze termination over to F/S. As ice builds
on the evaporator, the water level in the water tank lowers. The freeze cycle continues
until F/S opens and terminates the cycle.
(4) Pump-Out Cycle
LEDs 1, 3, and 2 are on. LED 4 is on when S4 dip switch 3 & 4 are set to 3 off and
4on. For details, see "II.C.3.c) Pump-Out Timer (S4 dip switch 3 & 4)." Comp and FMR
remain energized. HGV energizes. WV energizes if S4 dip switch 3 off and 4 on. LLV
de-energizes. PM stops for 2 seconds then reverses, taking water from the bottom of the
water tank and forcing pressure against the pump-out check valve seat allowing water to
go through the pump-out check valve and down the drain. At the same time, water ows
through the small tube to power ush F/S. When the pump-out timer terminates, the
pump-out is complete.
The rst pump-out occurs after the 1st freeze cycle, then every 10th cycle thereafter. The
pump-out frequency is factory set, and generally no adjustment is required. However,
where water quality is bad and the icemaker needs a pump-out more often, the pump-out
frequency can be adjusted. The pump-out frequency control (S4 dip switch 5 & 6) can
be set to have a pump-out occur every cycle, or every 2, 5, or 10 cycles. For details, see
"II.C.3.d) Pump-Out Frequency Control (S4 dip switch 5 & 6)."
23