Only qualified service technicians should attempt to install, service or maintain
this icemaker. No installation, service or maintenance should be undertaken
until the technician has thoroughly read this Instruction Manual. Likewise, the
owner/manager should not proceed to operate the icemaker until the installer
has instructed them on its proper operation.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the
installation, maintenance and service of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call or write to the HOSHIZAKI Technical Support Department for
assistance.
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: (770) 487-3360
Web Site: www.hoshizakiamerica.com
Note: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem
2
Page 3
• Please review this manual. It should be read carefully before the icemaker is installed
and operated. Only qualified service technicians should install, service and maintain the
icemaker. This manual should be made available to the technician prior to installation,
maintenance or service.
• Keep this manual with the icemaker for later reference.
CONTENTS
I. Specifications .................................................................................................................... 4
See the nameplate for electrical and refrigeration
specifications. This nameplate is located on the
upper right hand side of rear panel.
We reserve the right to make changes in specifications and design without prior notice.
NOTE: Only the “MODEL NUMBER” is replaced for F-1500MAH-C.
4
Page 5
[b] F-1500MWH, F-1500MWH-C (water-cooled)
See the nameplate for electrical and refrigeration
specifications. This nameplate is located on the
upper right hand side of rear panel.
We reserve the right to make changes in specifications and design without prior notice.
NOTE: Only the “MODEL NUMBER” is replaced for F-1500MWH-C.
5
Page 6
[c] F-1500MRH, F-1500MRH-C (remote air-cooled)
See the nameplate for electrical and refrigeration
specifications. This nameplate is located on the
upper right hand side of rear panel.
We reserve the right to make changes in specifications and design without prior notice.
NOTE: Only the “MODEL NUMBER” is replaced for F-1500MRH-C.
6
Page 7
2. Dimensions/Connections
[a] F-1500MAH, F-1500MAH-C
Unit = [inches] mm.
BACK VIEW
SIDE VIEW
FRONT VIEW
7
BOTTOM VIEW
Page 8
[b] F-1500MWH, F-1500MWH-C
Unit = [inches] mm.
BACK VIEW
SIDE VIEW
FRONT VIEW
8
BOTTOM VIEW
Page 9
[c] F-1500MRH, F-1500MRH-C
Unit = [inches] mm.
BACK VIEW
SIDE VIEW
FRONT VIEW
9
BOTTOM VIEW
Page 10
[ d] With Storage Bin
Unit = inches [mm.]
10
Page 11
[e] Condenser Unit Model URC-12F
Unit = inches (mm)
11
Page 12
II. Installation and Operating Instructions
1. Checks Before Installation
WARNING
Remove shipping carton, tape(s) and packing. If packing material is left in the
icemaker, it will not work properly.
IMPORTANT
Ensure all components, fasteners, and thumbscrews are securely in place.
1) Remove the front, top and side panels to prevent damage when installing the icemaker.
(See “2. How to Remove Panels.”)
2) Remove the package containing the accessories from inside the icemaker.
3) Remove the protective plastic film from the panels. If the icemaker is exposed to the sun
or to heat, remove the film after the icemaker cools.
4) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade turns freely.
5) Check that the compressor is snug on all mounting pads.
6) See the nameplate on the rear panel, and check that your voltage supplied corresponds
with the voltage specified on the nameplate.
7) This icemaker needs a storage bin. The recommended storage bin is HOSHIZAKI ICE
STORAGE BIN, Model B-500 series.
8) On remote air-cooled models, a remote condenser unit is needed. The recommended
remote condenser unit is HOSHIZAKI CONDENSER UNIT, Model URC-12F.
12
Page 13
2. How to Remove Panels
- See Fig. 1
a) Front Panel .............. Remove the screw.
Lift up and pull toward you.
b) Top Panel ................ Lift up front, push away,
and then lift off.
c) Side Panel ............... Remove the screw.
Pull slightly toward you, and
lift off.
3. Location
WARNING
This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within +45°F to +100°F; Normal operating water
temperature should be within +45°F to +90°F. Operation of the icemaker,
for extended periods, outside of these normal temperature ranges may
affect production capacity.
Fig. 1
For best operating results:
• Icemaker should not be located next to ovens, grills or other high heat producing
equipment.
• Location should provide a firm and level foundation for the equipment.
• Allow 6" clearance at rear and sides for proper air circulation and ease of maintenance
and /or service should they be required. Allow 24" clearance at top to allow for
removal of the auger.
4. Setup
1) Unpack the storage bin, and attach the four adjustable legs
provided (bin accessory) to the bottom of the storage bin.
2) Position the storage bin in the selected permanent position.
3) Place the icemaker on the top of the storage bin.
4) Secure the icemaker to the storage bin, by using
the two universal braces and two bolts
provided. See Fig. 2.
13
Fig. 2
Page 14
5) Seal the seam between the icemaker and the storage bin.
6) Level the icemaker/storage bin in both the left-to- right and front-to-rear directions. Adjust
the ice bin legs to make the icemaker level.
7) On flake machines, the flake size is adjustable to small (fine flakes) or large (coarse
flakes). The unit is shipped from the factory to produce fine flakes. To produce coarse
flakes, the upper cutter head must be removed. If adjustment is desired, please contact
an authorized Hoshizaki service company.
Cubelet machines can also be adjusted to produce small or large pieces of ice. The unit
is shipped from the factory to produce large pieces of ice. To produce small pieces, the
washer must be placed on top of the cutter instead of below. If adjustment is desired,
please contact an authorized Hoshizaki service company.
8) Replace the top panel and the front panel in their correct positions, and secure the front
panel with the screw.
5. Electrical Connection
WARNING
1. Electrical connection must be made in accordance with the instructions on a
“WARNING” tag provided with the pig tail leads in the junction box.
2. This icemaker requires a ground that meets the national and local electrical
code requirements. To prevent possible electrical shock to individuals or
extensive damage to the equipment, install a proper ground wire to the
icemaker.
• The white lead must be connected to the
neutral conductor of the power source.
Miswiring results in severe damage to the
icemaker. See Fig. 3.
• This icemaker must have a separate power
supply or receptacle of proper capacity. See
the nameplate.
• The opening for the power supply connection is
7/8" DIA to fit a 1/2" trade size conduit.
• Usually an electrical permit and services of
a licensed electrician are required
Fig. 3
14
Page 15
6. Installation of Remote Condenser Unit
[a] Checks Before Installation
1) Unpack and remove shipping carton, tape(s) and packing.
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that
the fan blade turns freely.
Make sure that the icemaker, line sets and remote condenser unit all use R-404A
3)
refrigerant.
[b] Location
The condenser unit must be positioned in a permanent site under the following
guidelines.
• A firm and flat site.
• A dry and well ventilated area with 24" clearance on both front and rear for ease of
maintenance and service should they be required.
• Normal condenser ambient temperature: -20°F to +122°F. Temperatures not within this
operating range may affect the production capacity of the icemaker.
• The maximum line length for the standard refrigerant charge is 66 feet. Should an
installation require a longer line length, please call 1-800-233-1940 for
recommendations concerning the correct additional refrigerant charge to be added.
Fig. 4
Note: If the recommended guidelines of the installation are exceeded, the icemaker
performance may be reduced.
15
Page 16
[c] Setup
1) Secure the legs to the condenser unit with eight M8 x 16 mm hexagon bolts and M8 nuts
as shown in the illustration. See Fig. 5.
Note: Locate the legs symmetrically.
2) The legs have eight mounting holes. Secure the legs with eight bolts (not included).
3) Install enough length of two copper tubings provided with Aeroquip couplings between
the icemaker and the condenser unit. The two copper tubings should be insulated
separately. See Fig. 6.
• Precharged tubing kits, available as optional equipment from HOSHIZAKI AMERICA,
are recommended.
4) Line sets fabricated in the field should be evacuated through the charging ports on the
Aeroquip couplings and charged with R-404A refrigerant vapor to a pressure of
15-30 PSIG.
Note: Factory fabricated tubing kits are precharged and do not need to be evacuated.
5) Remove the plastic caps protecting the couplings. Attach the two refrigerant lines to the
male couplings on the icemaker and the remote condenser unit. Each refrigerant line
must be connected as follows:
Icemaker discharge refrigerant line - 1/2" OD tubing to “DIS” of condenser unit
Icemaker liquid refrigerant line - 3/8" OD tubing to “LIQ” of condenser unit
Note: Make the connections at the remote condenser first and then at the icemaker.
.
Fig. 5
Fig. 6
16
Page 17
[d] Electrical Connection
WARNING
This remote condenser unit requires a ground that meets the national and
local electrical code requirements. To prevent possible electrical shock to
individuals or extensive damage to equipment, install a proper ground wire to
this condenser unit.
• This condenser unit must be connected to the fan motor junction box on the icemaker.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
• Usually an electrical permit and services of a licensed electrician are required.
1) Remove the louver panel.
2) Remove the junction box cover.
3) Connect the fan motor leads in the junction box of the remote condenser unit to the fan
motor leads in the junction box of the HOSHIZAKI remote air-cooled icemaker.
4) Install a ground wire from the icemaker to the remote condenser unit.
5) Replace the junction box cover and the louver panel in their correct positions.
Fig. 7
17
Page 18
[e] Stacking Condenser Unit
1) Secure the lower condenser unit to the legs
with eight bolts (not included).
2) Attach the upper condenser unit on the top of
the lower.
3) Secure the upper condenser unit with the four
screws provided.
4) Install refrigerant lines, and make electrical
connection for each fan motor as shown in
Items [c] and [d].
Fig. 8
7. Water Supply and Drain Connections
- See Fig. 9
• External filters, strainers or softeners may be required depending on the water quality.
• Water supply inlet is 1/2" female pipe thread (FPT).
Note: On water-cooled model, two water supply inlets are provided. One is
• A water supply line shut-off valve and drain valve should be installed. A minimum of 3/8"
OD copper tubing is recommended for the water supply lines.
• Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
• Drain outlet for icemaking is 3/4" FPT. The icemaker drain and the condenser drain
piping connections must be made separately from the bin drain.
Note: On water-cooled model, a 3/8" FPT is provided for the cooling water outlet.
• The drains must have 1/4" fall per foot on horizontal runs to get a good flow.
• The drains should not be piped directly to the sewer system. An air gap of a minimum of
2 vertical inches should be between the end of the drain pipe from the icemaker or the ice
bin and the floor drain.
for ice making water, and the other is for cooling water.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• In some areas, a back flow preventer may be required in the cooling water circuit.
18
Page 19
F-1500MAH, F-1500MAH-C
F-1500MRH, F-1500MRH-C
F-1500MWH, F-1500MWH-C
Fig. 9
19
Page 20
8. Final Checklist
1) Is the icemaker level?
2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F and
the water temperature within +45°F to +90°F all year around?
3) Is there at least 6" clearance at rear and sides and 24" at top for maintenance or
service?
4) Have all shipping carton, tape(s) and packing been removed from the icemaker?
5) Are all components, fasteners and thumbscrews securely in place?
6) Have all electrical and piping connections been made?
7) Has the power supply voltage been checked or tested against the nameplate rating and
the correct voltage selected? And has a proper ground been installed in the icemaker?
8) Are the water supply line shut-off valve and drain valve installed? Has the water
supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of
113 PSIG?
Note: The icemaker may stop running when the water supply is OFF, or if the pressure
is below 10 PSIG. When the proper water pressure is reached, the icemaker
automatically starts running again.
9) Have the compressor hold-down bolts and refrigerant lines been checked against
vibration and possible failure?
10) Has the bin control switch been checked for correct operation? Move the actuator
located on the top of the chute. The compressor should stop in 6 seconds, and the gear
motor in 6 seconds.
11) Has the end user been given the instruction manual, and instructed on how to operate
the icemaker and the importance of the recommended periodic maintenance?
12) Has the end user been given the name and telephone number of an authorized service
agent?
13) Has the warranty tag been filled out and forwarded to the factory for warranty
registration?
20
Page 21
9. Startup
WARNING
1. All parts are factory-adjusted. Improper adjustments may result in failure.
2. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
1) Clean the storage bin. (See “III. 2. Maintenance.”)
2) Open the water supply line shut-off valve.
3) Move the flush switch on the control box to the “ICE” position.
4) Turn on the power switch on the control box.
5) Replace the side, top and front panels in their correct positions.
6) Turn on the power supply.
21
Page 22
10. Preparing the Icemaker for Long Storage
- See Fig. 10
WARNING
When shutting off the icemaker for an extended time, drain out all water from
the water line and remove the ice from the storage bin. The storage bin should
be cleaned and dried. Drain the icemaker to prevent damage to the water
supply line at sub-freezing temperatures, using air or carbon dioxide. Shut off
the icemaker until the proper ambient temperature is resumed.
• Air-Cooled and Remote Air-Cooled Models
1) Run the icemaker with the water supply line shut-off valve closed.
2) Open the drain valve and blow out the water inlet line by using air pressure.
3) Turn off the power supply.
4) Remove the front panel.
5) Move the flush switch on the control box to the “FLUSH” position.
6) Turn on the power supply, and then drain out all water from the water line.
7) Turn off the power supply.
8) Turn off the power switch on the control box.
9) Replace the front panel in its correct position.
10) Close the drain valve.
11) Remove all ice from the storage bin, and clean the bin.
• Water-Cooled Model
1) Turn off the power supply and wait for 3 minutes.
2) Turn on the power supply and wait for 20 seconds.
3) Close the water supply line shut-off valve.
Fig. 10
4) Open the drain valve and quickly blow the water supply line from the drain valve to drain
water in the condenser.
5) Follow the above steps 3) through 11) in “• Air-Cooled and Remote Air-Cooled Models.”
22
Page 23
III. Cleaning and Maintenance
IMPORTANT
Ensure all components, fasteners and thumbscrews are securely in place after
any maintenance or cleaning is done to the equipment.
1. Cleaning and Sanitizing Instructions
WARNING
1. HOSHIZAKI recommends cleaning this unit at least once a year. More
frequent cleaning, however, may be required in some existing water
conditions.
2. To prevent injury to individuals and damage to the icemaker, do not use
ammonia type cleaners.
3. Always wear liquid-proof gloves to prevent the cleaning and sanitizing
solutions from coming into contact with skin.
[a] Cleaning Solution
Dilute 4.8 fl. oz. (142 ml) of recommended cleaner Hoshizaki “Scale Away” or
“LIME-A-WAY” (Economics Laboratory, Inc.) with 0.8 gallons (3 l) of warm water. This is a
minimum amount. Make more solution if necessary.
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after
dilution.
[b] Cleaning Procedure
1) Remove the front panel and top panel, then turn off the power supply.
2) Close the water supply line shut-off valve.
3) Remove all ice from the storage bin.
4) Move the flush switch to the “FLUSH” position.
5) Turn on the power supply and drain out all water from the water line.
6) Turn off the power supply.
Note: This unit is designed to start operating when the reservoir is filled with water.
7) Remove the strap connecting the spout to the chute assembly.
8) Remove the thumbscrews securing the spout and lift it off.
23
Page 24
9) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are filled and the solution starts to overflow into the drain pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between the
reservoir and evaporator assembly to block flow. Pour additional cleaning fluid
over the extruding head until the evaporator assembly is completely full.
10) Replace the spout and strap in their correct positions.
11) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on
the reservoir hose in step 9, remove it before operation.
12) Move the flush switch to the “ICE” position, then turn on the power supply. Replace the
top panel and front panel in their correct positions. Make ice using the solution until the
icemaker stops making ice.
13) Remove the front panel.
14) Move the flush switch to the “FLUSH” position to drain the remainder of the solution.
15) After the solution is drained, move the flush switch to the “ICE” position.
16) Replace the front panel in its correct position.
17) Open the water supply line shut-off valve and supply water to the reservoir.
18) When the gear motor starts, remove the front panel and turn off the power supply.
19) Drain out all water from the water line. See 4) through 6).
[c] Sanitizing Solution
Dilute 2.5 fl. oz. (74 ml or 5 tbs) of IMS-II Sanitizer or a 5.25% sodium hypochlorite solution
(chlorine bleach) with 5 gallons (19 l) of warm water.
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after
dilution.
[d] Sanitizing Procedure - Initial
1) Close the water supply line shut-off valve.
2) Remove the strap connecting the spout to the chute assembly.
3) Remove the thumbscrews securing the spout and lift it off. Remove the rubber O-ring
and nylon O-ring at the top of the cylinder and remove the packing between the spout
and chute.
24
Page 25
4) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are filled and the solution starts to overflow into the drain pan.
5) Remove the thumbscrews securing the proximity switch to the chute assembly.
6) Remove the chute assembly from the icemaker.
7) Remove the packing at the bottom of the ice chute.
8) Remove the three ties and the chute insulation.
9) Remove the six wing nuts and two baffles.
10) Remove the two thumbscrews, the plate and the packing from the top of the ice chute,
then remove the bin control assembly by sliding it slightly toward the chute opening and
lifting it off.
11) Disassemble the bin control assembly by removing the two snap pins, shaft and
actuator.
12) Remove the four thumbscrews, spout switch cover, belt switch, and actuator.
13) Soak the removed parts in .25 gallons (1 l) of sanitizing solution for 10 minutes then
wipe them down.
14) Rinse the parts thoroughly.
IMPORTANT
If the solution is left on these parts, they will rust.
15) Replace all parts in their correct positions.
IMPORTANT
When installing the baffles, make sure that the bent surface (the one without the
studs) faces the actuator so that the bent surface can guide the ice to the center
of the actuator.
16) Move the flush switch to the “ICE” position, then turn on the power supply. Replace the
top panel and front panel in their correct positions. Make ice using the solution until the
icemaker stops making ice.
[e] Sanitizing Procedure - Final
1) Remove the front panel and top panel, then turn off the power supply.
2) Move the flush switch to the “FLUSH” position.
3) Turn on the power supply and drain out all water from the water line.
25
Page 26
4) Turn off the power supply.
5) Remove the strap connecting the spout to the chute assembly.
6) Remove the thumbscrews securing the spout and lift it off.
7) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are filled and the solution starts to overflow into the drain pan.
8) Replace the spout and strap in their correct positions.
9) Allow the icemaker to sit for about 10 minutes before operation.
10) Move the flush switch to the “ICE” position, then turn on the power supply. Replace the
top panel and front panel in their correct positions. Make ice using the solution until the
icemaker stops making ice.
11) Remove the front panel.
12) Move the flush switch to the “FLUSH” position to drain the remainder of the solution.
13) After the solution is drained, move the flush switch to the “ICE” position.
14) Replace the front panel in its correct position.
15) Open the water supply line shut-off valve and supply water to the reservoir.
16) When the gear motor starts, remove the front panel and turn off the power supply.
17) Drain out all water from the water line. See 2) and 3).
18) Move the flush switch to the “ICE” position and run the icemaker.
19) Turn off the power supply after 30 minutes.
20) Pour warm water into the storage bin to melt all ice, then clean the bin liner with the
solution.
21) Flush out any solution from the storage bin.
22) Turn on the power supply and start the automatic icemaking process.
IMPORTANT
1. After cleaning, do not use ice made from the sanitizing solution. Be careful
not to leave any solution in the storage bin.
2. Follow carefully any instructions provided with the bottles of cleaning or
sanitizing solution.
3. Never run the icemaker when the reservoir is empty.
26
Page 27
2. Maintenance Instructions
1. This icemaker must be maintained individually, referring to the instruction
manual and labels provided with the icemaker.
2. To have the optimum performance of this icemaker, the following
consumable parts need periodic inspection, maintenance and
replacement:
Extruding Head
Housing
Gear Motor
Auger
Mechanical Seal
These parts should be inspected at least once a year or every 10,000 hours of
operation. Their service life, however, depends on water quality and
environment. More frequent inspection and maintenance are recommended.
Consult with your local distributor about inspection and maintenance service.
To obtain the name and phone number of your local distributor, call Hoshizaki
Technical Support at 1-800-233-1940 in the USA.
IMPORTANT
1) Stainless Steel Exterior
To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a
damp cloth containing a neutral cleaner to wipe off oil or dirt build up.
2) Storage Bin and Scoop
• Wash your hands before removing ice. Use the plastic scoop provided (accessory).
• The storage bin is for ice use only. Do not store anything else in the bin.
• Keep the scoop clean. Clean using a neutral cleaner and rinse thoroughly.
• Clean the bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
3) Air Filter
A plastic mesh air filter removes dirt or dust from the air, and keeps the condenser
from getting clogged. As the filter gets clogged, the icemaker’s performance will be
reduced. Check the filter at least twice a month. When clogged, use warm water and
a neutral cleaner to wash the filter.
4) Condenser (except water-cooled model)
Check the condenser once a year, and clean if required by using a brush or vacuum
cleaner. More frequent cleaning may be required depending on the location of the
icemaker.
27
Page 28
HOSHIZAKI AMERICA, INC.
618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A2OA10B
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.