HOSEOTELNET ATM300 Users Manual

Page 1
ATM300
User Manual
(ATM 300)
ReFLEX Module
ReFLEX Module
0/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 2
ATM300

Content

1. Description
2. Outline and Function
2.1 Outline
2.2 Description of 14 pin Connector
2.3 Sub Board & Data Link Cable
2.4 Package
3. Configure the ReFLEX Module – PPS -
3.1 login
3.2 List
3.3 Control
4. Message receiving and sending
4.1 HSM8800
4.1.1 Message sending
4.1.2 Message receiving
HOW TO SET “ReFLEX” TWO WAY RADIO MODULE.
ReFLEX Module
ReFLEX Module
1/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 3
1. Description
- System Block Diagram
ATM300
System
ReFLEX
Module
Host
Device
ReFLEX
Carrier’s
System
< Figure 1> ReFLEX system Block Diagram
- ReFLEX : The communication protocol between Carrier’s system and ReFLEX device or module through ReFLEX network.
- CLP Serial Interface : It is communication Linking Protocol (CLP), it enable the wire
communication between ReFLEx device or module and Host device through the Serial Interface.
● Message receiving and sending
The Message receiving and sending is possible by pc program ( HSM8800 v1.3) which
support the CLP serial interface even thought there is no Host device.
Refer to CLP reference manual for more information for serial interface of Communication Linking Protocol (CLP).
● Configure the ReFLEX Module
The configuration of ReFLEX Module will be done by PC based program ( PPS).
CLP Serial
Interface
ReFLEX Module
ReFLEX Module
2/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 4
2. Outline and Function
2.1 ReFLEX Module Outline
ATM300
< Figure 2 > ReFLEX Module
The interface between ReFLEX Module and Host Device will be done by 14 pin connector.
2.2 Description of 14 pin connector
1 8
2 9
3 10
4 11
5 12
6 13
7 14
< Figure 3 > 14 pin connector
ReFLEX Module
ReFLEX Module
3/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 5
ATM300
2.3 Pin Configuration
PIN Name Type Description
1 VCC_Tx 4V~10V, 3A, PA Voltage
2 VCC_Main 4V~10V,200mA, Controller Voltage
3 GPIO0 CMOS, General Purpose I/O
4 GPIO1 CMOS, General Purpose I/O
5 SI0 Reserved, NC
6 SO0 Reserved, NC
7 SCK0 Reserved, NC
8 VCC Reserved, NC
9 GND Signal Ground
10 Tx_Data UART Output
11 Rx_Data UART Input
12 Enable Module Enable
13 VPP Reserved, NC
14 GND Signal Ground
*Note :CMOS Level 3V
< Table 1> Pin description
2.4 Sub Board & Data Link Cable
< Figure 4 > Sub Board
ReFLEX Module
ReFLEX Module
4/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 6
ATM300
1) Sub Board :
The sub board will supply the power to module and it will be used for parameter setting (PPS) and
data receiving and sending by PC. If you apply the DC 4-10V to power terminal, then module will be activated.
The communication with PC will be able to by specific data link cable which supplied by module
supplier.
< Figure 5 > Data Link Cable
2) Data Link Cable :
It will be used for communication between ReFLEX Module and PC through Sub Board. The data link cable, which is being supplied by ATM300 supplier, incorporated the RS232C converter, then you can communicate with PC without additional peripherals.
ReFLEX Module
ReFLEX Module
5/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 7
2.5 Package
ATM300
< Figure 6 > Package
● Pre caution for Module(ATM 300) interface
The serial communication default speed is being set as 9600BPS, if you can change it CLP command.
- Module (ATM 300) has a power save mode function, then you must wake up the module
whenever you are to use it. The wake up time is 20ms, and if you are to wake up the module,
send the CLP command 0x19.
- After the reset, the module will not goes to power save mode for 60 seconds, then you can
do the parameter setting during that time by PPS program.
● Module Operation Description
- If you apply the power, the LED will be On and Off.
- ‘P’ LED will be “ON” when the Module synchronized to network.
- ‘T’ LED will be “ON” when Module is transmitting a data..
- LED can be disabled by command.
ReFLEX Module
ReFLEX Module
6/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 8
ATM300
3. Configure the ReFLEX Module – PPS -
Please refer to PPS manual for more details.
3.1 Login
< Figure 7 > Login
Key in the default password ‘HSTMAST’.
ReFLEX Module
ReFLEX Module
7/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 9
3.2 List
ATM300
< Figure 8 > List
- Global Scan List : Rx frequency setting(if Space is set Spacing is 10KHz)
- IS Address : Information Service address
- SPID : Service Provide ID
- Personal Address : Cap code
- Else : refer to PPS user’s guide
- Menu Description
① Export : Store the PPS Parameter file. ② Import : Reading the PPS Parameter file. ③ Download : Download the data to ReFLEX Module. ④ Personal Address : Put in the ReFLEX Module MSN.
ReFLEX Module
ReFLEX Module
8/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 10
3.3 Control
ATM300
- Power Level(mW) : RF Power Output
- PPS password : PPS login password
< Figure 9 > Control
ReFLEX Module
ReFLEX Module
9/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 11
ATM300
4. Message Sending and Receiving
If there is no Host device, you can send and receive the message through PC. The firmware, HSM8800 make you to sending and receiving the message, and you can also check the functionality of ATM300.
4.1 HSM8800
< Figure 10 > HSM8800 CLP Communicator v1.3
ReFLEX Module
ReFLEX Module
10/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 12
ATM300
4.1.1 Message Sending Sending the message to destination..
< Figure 11 > BMO Message Send
① Address Type : There are two(2) address type “P” and “E”
Address Type Description
P
E
② Address : key in the address of receiving part. ③ ReFLEX Test Message: key in the sending message. ④ Send : Click the “Send” button to send the message..
4.1.2 Message receiving
Download the received message on ReFLEX Module.
① Click the “Send” button to download the received message.
Send the message using PIN number of ReFLEX Module. (Ex. : 3071297 )
Sending the message using email address. ( Ex. :
hjino5@hoseo.or.kr )
< Table2 > Address Type
< Figure 12 > Download MSG
ReFLEX Module
ReFLEX Module
11/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Page 13
ATM300
HOW TO SET ReFLEX TWO WAY RADIO MODULE.
- Check the power source , 4~10V and 3A
- Soldering the Shield Case to Ground
- Connect the 50 ohm antenna to SMA connector of module *Do not operate the module without Antenna
- Apply the power and Interface
*Remark
- Do not change the trimmer set on case
- Do not open the shield case, In this case a warranty conditions will be invalid.
“CAUTION : Exposure to Radio Frequency Radiation. Antenna shall be mounted in such a manner to minimize the potential for human contact during normal operation. The antenna should not be contacted during operation to avoid the possibility of exceeding the FCC radio frequency exposure limit. The minimum separation distance of 20cm from the antenna to the body of user required.”
ReFLEX Module
ReFLEX Module
12/13
Tel 02 ) 2659 - 7345
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
http://www.hstelnet.com/
Loading...