HOSEOTELNET ATM200 User Manual

Page 1
Hoseo Telnet ReFLEX Module
User Manual
The ReFLEX Module
(ATM 200)
1/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 2
Hoseo Telnet ReFLEX Module
Content
1. Description
2. Outline and Function
2.1 Outline
2.2 Description of 14 pin Connector
2.3 Sub Board & Data Link Cable
2.4 Package
3. Configure the ReFLEX Module – PPS -
3.1 logon
3.2 List
3.3 Control
4. Message receiving and sending
4.1 ATM200
4.1.1 Message sending
4.1.2 Message receiving
HOW TO SET “REFLEX” TWO WAY RADIO MODULE.
2/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 3
Hoseo Telnet ReFLEX Module
1. Description
● System Block Diagram
System
Carrier's System
ReFLEX
ReFLEX
Device
CLP Serial
Interface
Host
Device
< Drawing 1. ReFLEX system Block Diagram >
- ReFLEX : The communication protocol between Carriers system and ReFLEX device or module
through ReFLEX network.
- CLP Serial Interface : It is communication Linking Protocol (CLP), it enable the wire communication between ReFLEx device or module and Host device through the Serial Interface.
● Message receiving and sending
The Message receiving and sending is possible by pc program ( HSM8800 v1.3) which
support the CLP serial interface even thought there is no Host device.
Refer to CLP reference manual for more information for serial interface of Communication Linking Protocol (CLP).
● Configure the ReFLEX Module
The configuration of ReFLEX Module will be done by PC based program ( PPS).
3/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 4
Hoseo Telnet ReFLEX Module
2. Outline and Function
2.1 ReFLEX Module Outline
< Drawing 2. ReFLEX Module >
The interface between ReFLEX Module and Host Device will be done by 14 pin connector.
4/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 5
Hoseo Telnet ReFLEX Module
2.2 Description of 14 pin connector
1 8
2 9
3 10
4 11
5 12
6 13
7 14
< Drawing 3 14 pin connector >
Pin Configuration
PIN Name Type Description
1 VCC_Tx 4V~10V, 3A, PA Voltage 2 VCC_Main 4V~10V,200mA, Controller Voltage 3 GPIO0 CMOS, General Purpose I/O 4 GPIO1 CMOS, General Purpose I/O 5 SI0 Reserved, NC 6 SO0 Reserved, NC 7 SCK0 Reserved, NC 8 VCC Reserved, NC
9 GND Signal Ground 10 Tx_Data UART Output 11 Rx_Data UART Input 12 Enable Module Enable 13 VPP Reserved, NC 14 GND Signal Ground
*Note :CMOS Level 3V
< Table 1 pin description >
5/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 6
Hoseo Telnet ReFLEX Module
2.3 Sub Board & Data Link Cable
< Drawing 4 Sub Board >
1) Sub Board : The sub board will supply the power to module and it will be used for parameter setting (PPS)
and data receiving and sending by PC. If you apply the DC 4-10V to power terminal, then module will be activated.
The communication with PC will be able to by specific data link cable which supplied by module
supplier.
< Drawing5. Data Link Cable >
6/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 7
Hoseo Telnet ReFLEX Module
2) Data Link Cable : It will be used for communication between ReFLEX Module and PC through Sub Board. The data link cable, which is being supplied by ATM200 supplier, incorporated the RS232C converter, then you can communicate with PC without additional peripherals.
2.4 Package
< Dwaring6. Package >
7/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 8
Hoseo Telnet ReFLEX Module
● Pre caution for Module(ATM 200) interface
The serial communication default speed is being set as 9600BPS, if you can change it CLP command.
- Module (ATM 200) has a power save mode function, then you must wake up the module
whenever you are to use it. The wake up time is 20ms, and if you are to wake up the
module, send the CLP command 0x19.
- After the reset, the module will not goes to power save mode for 60 seconds, then you can
do the parameter setting during that time by PPS program.
● Module Operation Description
- If you apply the power, the LED will be On and Off.
- P LED will be ON when the Module synchronized to network.
- T LED will be ON when Module is transmitting a data..
- LED can be disabled by command.
3. Configure the ReFLEX Module – PPS ­Please refer to PPS manual for more details.
3.1 Logon
< Drawing7 Log on >
Key in the default pass word HSTMAST.
8/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 9
Hoseo Telnet ReFLEX Module
3.2 List
< Drawing8 List >
- Global Scan List : Rx frequency setting(if Space is set Spacing is 10KHz)
- IS Address : Information Service address
- SPID : Service Provide ID
- Personal Address : Cap code
- Else : refer to PPS users guide
- Menu Description
① Export : Store the PPS Parameter file. ② Import : Reading the PPS Parameter file. ③ Download : Download the data to REFLEX Module. ④ Personal Address : Put in the ReFLEX Module MSN.
9/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 10
Hoseo Telnet ReFLEX Module
3.3 Control
- Power Level(mW) : RF Power Output
- PPS password : PPS login password
< Drawing9 Control >
10/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 11
Hoseo Telnet ReFLEX Module
4. Message Sending and Receiving
If there is no Host device, you can send and receive the message through PC. The firmware , HSM8800 make you to sending and receiving the message , and you can also check the functionality of AT 200.
4.1 HSM8800
< Drawing10. HSM8800 CLP Communicator v1.3 >
11/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 12
Hoseo Telnet ReFLEX Module
4.1.1 Message Sending Sending the message to destination..
< Drawing11. BMO Message Send >
① Address Type : There are two(2) address type “P” and “E”
Address Type Description
P
E
② Address : key in the address of receiving part. ③ ReFLEX Test Message: key in the sending message. ④ Send : Click the Send button to send the message..
4.1.2 Message receiving
Download the received message on ReFLEX Module.
① Click the “Send” button to download the received message.
Send the message using PIN number of ReFLEX Module. (Ex. : 3071297 )
Sending the message using email address. ( Ex. : hjino5@hoseo.or.kr
< Table2. Address Type >
< Drawing12. Download MSG >
)
12/13
Tel 02 ) 2659 - 7345 Fax 02 ) 3662 - 0973
http://www.hstelnet.com/
Page 13
Hoseo Telnet ReFLEX Module
HOW TO SET ReEFLEX” TWO WAY RADIO MODULE.
- Check the power source , 4~10V and 3A
- Soldering the Shield Case to Ground
- Connect the 50 ohm antenna to SMA connector of module *Do not operate the module without Antenna
- Apply the power and Interface
*Remark
- Do not change the trimmer set on case
- Do not open the shield case, In this case a warranty conditions will be invalid.
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHO RITY TO OPERATE THE EQUIPMENT.
“CAUTION: Exposure to Radio Frequency Radiation. Antenna shall be mounted in such a manner to minimize the potential for human contact during normal operation. The antenna should not be contacted during operation to avoid the possibility of exceeding the FCC radio frequency exposure limit. The minimum separation distance of 20cm from the antenna to the body of user required.”
13/13