Hurricane Rated Door Systems
Architectural Details
Horton Automatics
World Headquarters
4242 Baldwin Boulevard
Corpus Christi, Texas 78405-3399 USA
Phone: 800-531-3111, 361-888-5591
Fax: 361-888-6510
www.hortondoors.com
Horton Automatics, Ltd.
United Kingdom
Unit A, Hortonwood 31
Telford, Shropshire, England TF1-7YZ
Phone: (44) 01952 670169
Fax: (44) 01952 670181
A Division of
Overhead Door Corporation
A Sanwa Shutter Company
Form No. A503 ©2008 Horton Automatics Printed in U.S.A.
Construction
HD-Storm™Sliding Door Systems
Automatic Door System
Horton Automatics hurricane rated sliding door systems are Miami-Dade approved and meet the most
stringent windforce ratings for coastal areas as well as inland areas affected by tropical storms.
Single Slide
Wind-Debris Map
Biparting
Applications
Health Care
Office/Commercial
High Rise Residential
Home Improvement
Centers
Grocery Stores
Other Retail
Schools/Universities
Government
ProfilerStorm®Series
Sleek 4" x 6" Header
Complementing the 80 PSF HD-Storm™ Series, Horton's
ProfilerStorm
®
sliding door systems are an industry standard
for Miami-Dade compliance up to ±55 PSF windforce ratings.
A wide range of features add application versatility:
• Available for small and large missile impact and non-impact applications
• Linear operator
• Emergency egress designs including panic devices, single or full breakout
• Electric lock and power fail options
Rugged Corner Block Construction
Heavy duty rails with integral corner
blocks add structural integrity that
is far superior to mass produced
through-bolt panels.
Shown: HD-Storm™ Series
Steel Reinforced Rails
High strength steel tubes are
integrated into rails to reinforce
holding power during severe weather.
Shown: HD-Storm™ Series
Other Hurricane Rated Sliding Door Systems
ProfilerStorm®Selection Guide
SINGLE SLIDE
Breakout Opening
Unit Width Max Slide Opening Type 110 Type 310 Ratings
(Windload)
7'-0" (2134) 2'-10 1/2" (870) 3'-3 1/4" (997) 6'-3" (1905) +/-55 PSF
8'-0" (2438) 3'-4 1/2" (1029) 3'-9 1/4" (1149) 7'-3" (2210) +/-55 PSF
BIPARTING
Breakout Opening
Unit Width Max Slide Opening Type 110 Type 310 Ratings
(Windload)
10'-0" (3048) 3'-9 1/2" (1156) 4'-7" (1397) 8'-9 1/2" (2680) +/-55 PSF
12'-0" (3658) 4'-9 1/2" (1461) 5'-7" (1702) 10'-9 1/2" (3289) +/-55 PSF
14'-0" (4267) 5'-9 1/2" (1765) 6'-7" (2007) 12'-9 1/2" (3899) +/-55 PSF
16'-0" (4877) 6'-9 1/2" (2070) 7'-7" (2311) 14'-9 1/2' (4509) +/-55 PSF
up to
55 PSF
Did You Know?
The PSF requirement of
an entrance is determined
by several factors
including wind speed,
building structure, building
height, door location, and
roof configuration.