Horton 4100LE User Manual

Specify Swing Door Operators In The Proper Section
Problem
Low Energy/ADA compliant automatic swing door operators are sometimes incorrectly specified in MasterFormat™ 2004 Section 08 06 71 or 08 71 00 “Door Hardware,” typically resulting in an unsatisfied owner and improper entrance operation.
Solution
Specify automatic swing door operators in Section 08 42 29.33 “Swinging Automatic Entrances” or Section 08 71 13 “Automatic Door Operators” for code compliance, professional installation and years of trouble-free service. With AAADM* certified installation, your clients are assured that:
• Automatic operators are properly calibrated and meet applicable codes for mode of operation
• Operators are paired correctly with the doors and associated hardware
• Product and labor warranties are backed by qualified professionals
Use These Specifications
08 42 29.33 or 08 71 13
Automatic Door Operators
Not These Specifications
08 06 71 or 08 71 00
Door Hardware
For automatic door operators
Architect Specification Guide
*Specify Horton and demand AAADM certied installation
LH-RH
LHR-RH
LH RH
All hand combinations available
Arm & Header above
8"
Door Panel
Door clearance (If limited use Parallel Arm)
6" Side Load
6"
Operator Access
Arm & Header above
Door Panel
Emergency break-out feature for center pivoted door panels
Operator Access
4 1/2"
Bottom
Load
6"
Push Plate
60" (1524)
32" (813)
Minimum
120 V AC
Required
24" (610)
Minimum
(Alternate Switch Location)
Series 4100 LE
Architect Specification Guide
Activating device to be located on each side of opening for two-way traffic as per ANSI Safety Standard A117.1
Installation and Operation
Architectural Details
Horton Automatics World Headquarters
4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 USA
Phone: 800-531-3111, 361-888-5591 Fax: 361-888-6510
www.hortondoors.com
Horton Automatics, Ltd. United Kingdom
Unit A, Hortonwood 31 Telford, Shropshire, England TF1-7YZ
Phone: 01952 670169 Fax: 01952 670181
A Division of
Overhead Door Corporation
A Sanwa Holdings Company
Form No. B700 ©2010 Horton Automatics Printed in U.S.A.
HD-Swing®4100LE & EasyAccess 7100 Low Energy Operators
Once the activating switch is pressed, the Series 4100LE or 7100 operator slowly opens the door and holds it open for an adjustable length of time. This creates a barrier-free doorway and gives the pedestrian time to pass through the door before it slowly closes using spring force of less than 15 pounds (67 N).
Adjustments:
Selection Guide
Electrical Requirements:
120 or 220 VAC, 50 - 60 Hz, single phase, 15 amp service. Current draw - 3.15 amps.
• Opening speed: 3 to 6 sec. to 80° (Open check)
• Closing speed: 3 to 6 sec. from 90° to 10° (Close Check)
• Time delay: 2 to 30 sec. (ANSI A156.19 requires 5 sec. minimum time delay)
Standard Single Units
Door Width Header Width
3'-0" (914) 3'-3" (991)
3'-6" (1067) 3'-9" (1143)
4'-0" (1219) 4'-3" (1295)
Standard Pair Units
Pair Width Header Width
6'-0" (1829) 6'-9" (1905)
7'-0" (2133) 7'-3" (2210)
8'-0" (2438) 8'-3" (2515)
Maximum Door Width:
4100LE 4'-6" (1524) 7100 3'-6" (1067)
Maximum Door Weight:
4100LE 700 lbs (320kg) 7100 200 lbs (91kg)
Did You Know?
Low energy operators move the door slowly at a rate considered intrinsically safe
Surface Mount Bottom Access with Out Swing Arm Assembly
Surface Mount Side Access
with In Swing Arm Assembly
Surface Mount Bottom Access
with In Swing Parallel Arm Assembly
Shown: EasyAccess
®
Series 7100 Operator
Shown: HD-Swing
®
Series 4100 Operator
Shown: HD-Swing
®
Series 4100LE
4"
Side Load
Arm & Header above
Exterior
Operator Access
6"
Door Panel
Loading...