Horton 4000LE User Manual

Low Energy Swing Door Operators
HD-Swing® LE
Series 4000LE Heavy Duty Low Energy
Handicap Accessible
For High Trafc or Extra Large Barrier-Free Doors
Compliant with ANSI A156.19, A117.1 and Americans With Disabilities Act of 1990
Standard system features & benets:
• Heavy duty gear drive and 1/8 HP motor designed for high wind conditions, stack pressure and high volume pedestrian trafc. Appropriate for heavy or oversized doors.
• Choice of mounting type: Surface mount or overhead concealed
• Choice of header: 6" x 6" side access or 4 1/2" x 6" bottom access
• Available for butt hung, center pivoted or off set pivot door assemblies
• Installs easily with no structural changes required
Push Plate or Push Button Activation
Additional Features/Benets
• Push-N-Go activation by pushing or pulling door panel
• SoftTouch obstruction sensing
• Easily adjustable opening & closing speeds
• Manual operation in case of power failure
• Available in a variety of anodized, paint or clad nishes
®
automatic
®
reversing and
Did You Know?
Low energy
Specify Horton and demand AAADM certied installation
operators move the door slowly at a rate considered intrinsically safe.
Low Energy Swing Door Operators
HD-Swing® LE
Series 4000LE Heavy Duty Low Energy
Once the activating switch is pressed, the Series 4000 LE operator slowly opens the door and holds it open for an adjustable, delayed length of time. This creates a barrier-free doorway and gives the pedestrian time to pass through the door before it slowly closes using spring force of less than 15 pounds (67 N.)
Installation and Operation
Electrical
Activating device to be located on each side of opening for two-way trafc as per ANSI Safety Standard A117.1
Requirements:
32" (812)
Minimum
120, 220 VAC, 50 - 60 Hz, single phase, 15 amp service. Current draw - 3.15 amps.
Adjustments:
• Opening speed: 3 to 6 sec. to 80° (Open check)
• Closing speed: 3 to 6 sec. from 90° to 10° (Close Check)
• Time delay: 2 to 30 sec. (ANSI A156.19 requires 5 sec. minimum time delay).
Selection Guide Architectural Details
Standard Single Units
Door Width Header Width
3'-0" (914) 3'-3" (991)
3'-6" (1067) 3'-9" (1143)
Standard Pair Units
Pair Width Header Width
5'-0" (1524) 5'-3" (1600)
6'-0" (1829) 6'-9" (1905)
7'-0" (2133) 7'-3" (2210)
Maximum Door Width:
4'-6" (1524)
4 1/2" (114)
4000LE
Operator
Operator Access
Surf ace Mount Bot tom Acce ss
with Outswing Arm Assembly
Arm & Header above
Door Panel
Ext erior
24" (610)
Minimum
( Alternate Switch Location )
6" (152)
Ceil ing Line
8"
(203)
60" (1524)
6" (152)
4000LE
Operator
Surfa ce Mount Side Access
with Inswing Arm Assembly
Interior
Arm & Header above
Appr oximat e door clearance.
Door Panel
Push Butt on
Operator Access
120 VAC
Required
Series 4100 LE
Push
OR
Pl ate
6" (152)
Hinge Assem bly by Others
Overhead Concealed Side Access
with Of fset Ar m Assembly
6" (152)
4000LE
Operator
Operator Access
Power Arm
Drive Block
6" (152)
Horton Automatics World Headquarters
4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 USA
Phone: 800-531-3111, 361-888-5591 Fax: 361-888-6510
www.hortondoors.com
Horton Automatics, Ltd. United Kingdom
Unit A, Hortonwood 31 Telford, Shropshire, England TF1-7YZ
Phone: 01952 670169 Fax: 01952 670181
Form No. B501, Rev. 2/2015 ©2015 Horton Automatics Printed in U.S.A.
A Division of
Overhead Door Corporation
A Sanwa Shutter Company