Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section
numbers and titles per CSI "MasterFormat" and specifier's practice. Consult with manufacturer regarding
performance requirements for units applicable to project, as well as, related equipment and accessories required.
PART I – GENERAL
1.01 SUMMARY
A. WORK INCLUDED: Furnish complete automatic aluminum lead lined door system, as specified, that has been
manufactured, fabricated and installed to maintain performance criteria stated by manufacturer without defects,
damage or failure.
B. RELATED WORK:
1. Concrete: Division 03, applicable sections.
2. Masonry: Division 04, applicable sections.
3. Thermal and Moisture Protection: Division 07, applicable sections.
5. Openings: Division 08, applicable sections.
6. Electrical: Division 26, applicable sections.
1.02 REFERENCES
A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar
Materials.
B. AMERICAN ASSOCIATION OF AUTOMATIC DOOR MANUFACTURERS (AAADM).
C. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI Z97.1: Safety Glazing Materials Used in
Buildings - Methods of Test.
D. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) B221: Aluminum-Alloy Extruded Bars, Rods,
Shapes and Tubes.
E. THE ALUMINUM ASSOCIATION (AA) Aluminum Finishes Manual.
1.03 SUBMITTALS
A. PRODUCT DATA: Submit manufacturer's complete product and installation data.
B. SHOP DRAWINGS: Submit drawings showing layout, profiles, product components including anchorage,
accessories, finish and glazing details (where required).
1.04 QUALITY ASSURANCE AND PERFORMANCE REQUIREMENTS
A. INSTALLERS QUALIFICATIONS: Installer shall be factory trained, certified by AAADM, and experienced to
perform work of this section.
B. MANUFACTURER’S QUALIFICATIONS: Manufacturer to have minimum (5) five years successful experience in
the fabrication of automatic doors of the type required for this project. Manufacturer capable of providing field
service representation during installation, approving acceptable installer and approving application method.
1.05 WARRANTIES
A. MANUFACTURER'S WARRANTY: Units to be warranted against defect in material and workmanship for a
period of one year from the Date of Substantial Completion.
ARCHITECTURAL SPECS
Pro
Slide
®
Telescoping
Series
2003T-LL
®
2
4242 Baldwin Boulevard
Corpus Christi, Texas
USA 78405-3399
Tel: 800-531-3111, 361-888-5591
Fax: 800-531-3108, 361-888-6510
www.hortondoors.com
The Automatic Choice
AUTOMATIC SLIDING DOORS
Lead lined Sliding Door System
with Electric Belt Drive Operator
Page 2 of 4,
A25.2
Feb 15
Manufacturer's warranty is in addition to, and not a limitation of, other rights owner may have under Contract
Documents.
B. DISTRIBUTOR'S WARRANTY: One year warranty: Labor & transportation charges for defective parts
replacement.
1.06 PROJECT CONDITIONS
FIELD MEASUREMENTS: Verify actual dimensions/openings by field measurements before fabrication and record
on shop drawings. Coordinate with fabrication and construction schedule to avoid construction delays.
1.07 DELIVERY, STORAGE AND HANDLING
A. ORDERING AND DELIVERY: Comply with factory's ordering instructions and lead time requirements. Delivery
shall be in factory's original, unopened, undamaged containers with identification labels intact.
B. STORAGE AND PROTECTION: Provide protection from exposure to harmful weather conditions and vandalism.
PART II – PRODUCTS
2.01 MANUFACTURER
HORTON AUTOMATICS, a division of Overhead Door Corporation, shall manufacture automatic sliding door(s) of
type(s) and size(s) specified on plans and door schedule.
2.02 EQUIPMENT
A. MANUFACTURED DOOR UNITS: Shall include operator, header with roller track, carrier assemblies, framing
jambs, sliding door panel(s), activation, safety devices and accessories required for complete installation.
Leading slide panel will open twice as fast as adjacent sliding panel.
1. Configuration: ‘P-X-X’ or ‘X-X-P’ (handing as viewed from face plate side).
2. Mounting Type: Surface mounted.
3. Door Type: Type 010T: Sliding panels sliding along wall.
B. OPERATOR: The Electric Operating Mechanism shall be ProSlide® Telescoping Series 2003T Belt Drive. The
operator shall be mounted and concealed within the header.
1. Operating force shall be accomplished through a 1/8 HP DC permanent magnet motor with worm gear
transmission and 1800 RPM working with drive belt, attached door hangers, and idler pulley. Maximum
current draw shall not exceed 3.15 amps. Drive belt to be steel reinforced nylon, 1/2" (13 mm) wide. Idler
pulley to be reinforced, metallic material.
2. Master Control shall be 16 bit microprocessor controller with dual on-board seven-segment alphanumeric
diagnostic display and position encoder. The encoder shall monitor revolutions of the operator shaft and send
signals to microprocessor controller to define door position and speed. The control shall have minimum of 28
programmable parameters including the following functions:
a. Adjustable opening and closing speeds.
b. Adjustable back-check and latching with adjustable braking.
c. Adjustable hold-open time between 1 to 30 seconds.
d. Adjustable Reversing Circuit will reopen door unit if closing path is obstructed.
e. Separate day and night modes of operation with security over-ride.
3. On/Off Switch shall be supplied. When switched OFF, unit reverts to free manual operation (likewise during
electrical power failure).
C. SECURITY AND SAFETY POWER FAIL OPTIONS:
1. Automatic lock: Automatically locks slide function of door when in closed position. Additional power supply for
autolock not acceptable.
ARCHITECTURAL SPECS
Pro
Slide
®
Telescoping
Series
2003T-LL
®
3
4242 Baldwin Boulevard
Corpus Christi, Texas
USA 78405-3399
Tel: 800-531-3111, 361-888-5591
Fax: 800-531-3108, 361-888-6510
www.hortondoors.com
The Automatic Choice
AUTOMATIC SLIDING DOORS
Lead lined Sliding Door System
with Electric Belt Drive Operator
Page 3 of 4,
A25.3
Feb 15
a. Autolock Fail Secure: If power fails the lock engages.
b. Autolock Fail Safe: If power fails the lock disengages.
2. Uninterrupted Power Supply (UPS) Battery Backup:
a. Power Fail Open: If power fails the door slides open.
b. Power Fail Close: If power fails the door slides closed.
D. PROSLIDE® TELESCOPING HEADER: Shall be 8" (152 mm) deep by 6" (152 mm) high. Header shall be
aluminum construction with removable face plate.
E. CARRIER ASSEMBLIES AND HEADER ROLLER TRACK: Shall be double track system that will provide for
two-speed travel of sliding panels. Carrier assemblies shall support door panels with four rollers per panel.
Rollers will be non-metallic, high quality ball bearing wheels 2" (51 mm) diameter. Anti-Derailing shall be
accomplished by means of two additional adjustable rollers per panel. Overhead header roller track shall be
continuous aluminum and replaceable.
F. SLIDING PANEL(S) AND SIDELITE(S): Shall be aluminum, 1-3/4" (44 mm) deep medium stile rails with a
structural core of resin impregnated Kraft honeycomb. Panels will be provided with 1/16” factory lead lining, vinyl
weatherstripping and nylon sweeps and clad all around with stainless steel or aluminum. Sliding panels shall
have concealed bottom guides to stabilize slide travel.
Optional Vision Lite: 7/16” leaded glass glazing with maximum size of 15 3/4” x 15 3/4” (400 mm x 400 mm).
G. JAMBS/FRAME: Shall be aluminum with dimensions of 1 3/4" (44mm) deep by 6" (152mm) wide.
2.03 RELATED EQUIPMENT
A. ACTIVATING DEVICE: Shall be 24 VAC, class ll circuit. Switch to be located on each side of the opening and
shall be one of the following:
1. Touchless wall mounted switch (optional jamb mounted) using diffused scanning technology with adjustable
range up to 15" (381 mm). Junction box included.
2. Motion Sensor: Mounted above opening on header or wall.
3. Push Plate Wall Switch: Momentary contact switch, 6 1/4” (159 mm) dia. stainless steel plate on standard
junction box.
B. THRESHOLD PRESENCE SENSORS:
1. Header mounted sensors shall provide active infrared presence detection on each side of the door unit and
shall remain active throughout the entire door opening and closing cycle.
2. Hold-open beams: Two pulsed infrared photoelectric beams to be mounted in vertical rails of sidelite or in
jambs. Sender/receiver arrangement parallels door opening.
2.04 RELATED WORK REQUIREMENTS
A. ELECTRICAL: 120 VAC, 50/60 cycle, single phase, dedicated 20 amp circuit per operator. Non-North American
voltages can be 240 VAC 50/60 cycle (operator must have 240 volt power supply).
B. GLASS AND GLAZING: Glass stops, glazing vinyl and setting blocks for field glazing as per Safety Glazing
standard ANSI Z97.1.2. Contractor to coordinate acquisition of glass in thickness and type in accordance with
manufacturer's recommendations for prescribed design.
2.05 MATERIALS, FINISHES AND FABRICATION
A. EXTRUDED ALUMINUM: ASTM B221, 6063-T5 alloy and temper, anodized:
4242 Baldwin Boulevard
Corpus Christi, Texas
USA 78405-3399
Tel: 800-531-3111, 361-888-5591
Fax: 800-531-3108, 361-888-6510
www.hortondoors.com
The Automatic Choice
AUTOMATIC SLIDING DOORS
Lead lined Sliding Door System
with Electric Belt Drive Operator
Page 4 of 4,
A25.4
Feb 15
B. FINISHES (for all exposed aluminum surfaces): Shall be one of the following:
1. Clad with stainless steel #4 brushed finish.
2. Clad with aluminum 204-R1 Clear: Arch. Class 2 Clear Anodized Coating, AA-MI2C22A31.
C. PANEL CONSTRUCTION:
1. Corner block type with 3/16” steel backup plate construction, mechanically secured with minimum of four
hardened steel screws. Sash consists of snap-in glass stops, snap-in glazing beads and vinyl gaskets.
D. FRAME CONSTRUCTION: Butt joints, mechanically secured with screws and formed aluminum corner
brackets.
E. OPERATOR CONSTRUCTION: Electromechanical, modular type construction.
PART III - EXECUTION
3.01 EXAMINATION
SITE VERIFICATION OF CONDITIONS: Installer must verify that base conditions previously installed under other
sections are acceptable for product installation according to with manufacturer's instructions. Notify the Contractor
in writing of conditions detrimental to the proper and timely completion of work. Do not start work until all negative
conditions are corrected in a manner acceptable to the installer and manufacturer.
3.02 INSTALLATION
A. GENERAL: Installer shall be factory trained, certified by AAADM, and experienced to perform work of this
section. Install door units plumb, level and true to line, without warp or rack of frames or sash with
manufacturer's prescribed tolerances. Provide support and anchor in place.
B. DISSIMILAR MATERIALS: Comply with AAMA 101, Appendix Dissimilar Materials by separating aluminum
materials and other corrodible surfaces from sources of corrosion or electrolytic action contact points.
C. ELECTRICAL: General or electrical contractor to install all wiring to operator on a separate circuit breaker routed
into header, as well as, install all required power and low voltage wiring.
3.03 CLEANING, ADJUSTMENT AND PROTECTION
A. CLEANING: After installation, installer to take following steps:
1. Remove construction debris from construction site and legally dispose of debris.
2. Repair or replace damaged installed products.
3. Clean product surfaces and lubricate operating equipment for optimum condition and safety.
B. ADJUSTMENT: AAADM certified technician to inspect and adjust installation.
C. ADVISE CONTRACTOR: Of precautions required through the remainder of the construction period, to ensure
that doors will be without damage or deterioration (other than normal weathering) at the time of acceptance.
Note: Horton Automatics reserves the right to make product improvements and change specifications without notice
.
END OF SECTION
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.