The Z222 valve with auxiliary switch has been designed to control the water circulation in fully pumped systems, which employ a single pump for both hot water and central heating circuits by allowing the flow to either or
both circuits using separate valves.
ZonePlus Z222 zone valve
Installation and commissioning
2
Operation
Installation
Valve position - In the event that mains power is disconnected the valve automatically spring-returns to the closed position.
Override lever: For manually operating systems to open valve for system draining or filling. During normal operation, the lever must be in the auto position
The Z222 consists of a 2 port valve body (Ref. B222) to which a self contained actuator (Ref. A222) is attached
POSITIONING OF VALVE
On new installations fit the Z222 valve ensuring that the actuator head is NOT below the horizontal level of the pipe work and that the flow is in the direction of the arrow. Also check that neither the open vent or the cold feed are isolated. This will ensure system and product safety at all times. Remember to make allowances for working, maintenance and replacement.