Horstmann ChannelPlus H11XL 2 User Operating Instructions Manual

Page 1
Single Channel 24 hour Timeswitch
The ChannelPlus family of electronic programmers offer a range of advanced features
coupled with simplied ‘menu driven’ programming all designed to help save energy.
The Horstmann ChannelPlus H11XL series 2 is a single channel timeswitch
allowing up to 3 On/Off settings per day.
For day to day operation the H11XL has a manual 1 or 2 hour boost button
as well as an advance button to bring forward the next programmed operation.
designed to make the operation of the ChannelPlus H11XL as simple as possible to use.
All series 2 ChannelPlus programmers are direct replacements for earlier ChannelPlus models.
ChannelPlus H11XL Series 2
User Operating Instructions
1
Page 2
2
The ChannelPlus H11XL Series 2 Timeswitch
The simple instructions contained in this user guide are designed to help with the
programming and operation of the unit. Most of the following instructions require the front
ap to be lowered. Please replace the ap when normal operation is required.
PRODUCT OVERVIEW - DETAIL SHOWN WITH THE FLAP LOWERED
1 Current time of day 2 Day of week and date 3 Channel Heading 4 Current programme 5 Next On/Off time 6 Channel ON indicator 7 ADVANCE and ENTER button ILLUMINATED WHEN ACTIVE 8 BOOST and COPY button ILLUMINATED WHEN ACTIVE 9 PLUS button 10 MINUS button 11 Programme Select button (Coloured Blue) 12 SET button (Coloured Green) 13 Front Flap (Lowered)
1
9
10
11
4
3
5
6
7
12
8
13
2
HTG
Page 3
Display Information
The ChannelPlus H11XL Series 2 timeswitch has a fully graphical, back-lit display. The information displayed will change depending upon the settings made and which mode you are in. During different programming modes and/or setting screens the current time, day/date, holiday indicator will only appear when necessary, this is to reduce confusion during the programming process. This is explained further in later sections of this guide.
ACTIVATING THE BACK–LIT DISPLAY
The display will illuminate for approximately 1 minute whenever a button is pressed.
To illuminate the display for viewing purposes only press the green menu button under the front ap twice.
SETTING AND ADJUSTING
When setting or adjusting, the timeswitch will automatically return to the running mode if no buttons are pressed for approximately 1 minute.
If the setting or adjusting has not been nished, please start the procedure again.
TIME OF DAY
The ChannelPlus H11XL incorporates a factory set clock and calendar which means that no adjustments should be necessary to the time of day and BST/GMT time changes take place automatically.
3
Time
Day
Date
Channel
header
Holiday
function
active
Channel/
Zone
status
Page 4
4
Manual Overrides
BOOST FUNCTION - 1 OR 2 HOUR TEMPORARY OVERRIDE
The boost facility will allow the user to either activate a channel which is currently ‘OFF’ for 1 or 2 hours, or to extend a current ‘ON’ period by 1 or 2 hours. To indicate the boost being activated the ‘BOOST’ button will stay illuminated for the duration of the boost/extension period. The display will also indicate the extension to the time visually on the display.
ADVANCE FUNCTION - BRINGS FORWARD THE NEXT ON OR OFF OPERATION
The advance facility will allow the user to either switch the timeswitch ‘ON’ when currently ‘OFF’ or switch the timeswitch ‘OFF’ when currently ‘ON’. To indicate the advance feature being activated the ‘ADVANCE’ button will stay illuminated until the next programme switching time, the user display will change to also indicate the status of the channel and the next switching time.
Press BOOST button once: Your system will be boosted for 1 hour
Press ADVANCE button once to move to the next ON/OFF time
Press BOOST button twice: Your system will be boosted for 2 hours
To cancel the advance press the ADVANCE button again. This will return the unit to its normal programme
Press BOOST button a third time to cancel the period and return to the normal programme
Page 5
5
Programme Override Facilities
With the ChannelPlus H11XL Series 2 timeswitch operating in the normal running mode it is possible to alter the functionality of the programme by means of the blue ‘select’ buttons under the front ap.
The options include;
AUTO - Timeswitch output follows all programmed ‘ON’ and ‘OFF’ times.
ALL DAY - Timeswitch output operates from 1st ‘ON’ time until 3rd ’OFF’, ignoring all switching times in between.
ON - Timeswitch output will be constantly ‘ON’.
OFF - Timeswitch output will be constantly ‘OFF’, there is the ability to turn off heating during summer without altering the programme times. 1 or 2 hour boost still available.
All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user.
The diagram below illustrates how to alter the setting, it assumes that the timeswitch is in the AUTO mode to begin with.
Press SELECT once. Programme goes from AUTO to ALL DAY
Timeswitch will operate from first ON until last OFF period
Press SELECT again. Programme goes from ALL DAY to ON
Timeswitch will be continuously ON
Press SELECT again. Programme goes from ON to OFF
Timeswitch will be continuously OFF
Press SELECT again. Programme goes from OFF to AUTO
Programme will return to normal ON and OFF times
Page 6
6
Setting the Programme Times
The programme times have been preset as shown in the chart below.
If any changes are required to the programme times please complete the operation as described in the owchart left.
1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF
6.30AM 8.30AM 12.00PM 12.00PM 4.30PM 10.30PM
Press the green
‘SET’ button
Use the ‘+’ and ‘-‘
buttons to adjust required on time
Repeat process for
the 2nd and 3rd
time settings
Select ‘Set ON/OFF
times’
Open cover
Press ‘ENTER’
Press ‘ENTER’
Adjust OFF timePress ‘ENTER’
Press the green
‘SET’ button
Press the green
‘SET’ button
Close cover
DEFAULT TIME SETTINGS - AM/PM
SET HOLIDAY MODE
SET DEFAULTS
SETTING ON/OFF TIMES
ON 06.30 ON 12.00 ON 16.30
OFF 08.30 OFF 12.00 OFF 22.30
PERIOD 1 PERIOD 2 PERIOD 3
SAMPLE DISPLAYS
SET ON/OFF TIMES
ON 06.30
Enter the required on and off times
Select ‘Set ON/OFF times’
ADJUSTING SETTINGS
When carrying out any alterations to the programmed times and settings the programmer will return to its normal run mode in 1 minute if no adjustments are made in that time.
Page 7
7
Setting the Holiday Mode
The holiday mode can be used to suspend the program function of the ChannelPlus timeswitch, it can be set in advance of your departure date and for as long a period as required. The holiday function operates from mid-day to mid-day, this means it can be easily set to ensure your home is warm for your return. When the holiday mode has been set a smiley face will appear on the display. When the holiday mode is active only the day/date and smiley face will be displayed.
To cancel an active holiday period please press any of the Select buttons under the front ap.
PLEASE NOTE: Any alteration to the current time or date will cancel any Holiday programme set.
N.B. Do not use the holiday programme when conditions are such that frost damage to the heating system is possible (unless a frost protection thermostat is tted to your system).
Press the green
‘SET’ button
Use the ‘+’ and ‘-’
buttons to adjust
START DATE
Repeat process for
end period
Use the ‘+’ and ‘-’
buttons to adjust
START MONTH
Use the ‘+’ and ‘-’
buttons to select
‘HOLIDAY MODE’
Open cover
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press the green
‘SET’ button
Press the green
‘SET’ button
Close cover
Use the ‘+’ and ‘-’
buttons to adjust
START YEAR
SETTING HOLIDAY MODE
START AT MID-DAY ON
SEPT 2009
FINISH AT MID-DAY ON
21 SEPT 2009
THURS 16 SEPT
SAMPLE DISPLAYS
Enter holiday dates
Display when holiday mode is set
1
Page 8
Adjusting Default Settings
The ChannelPlus H11XL Series 2 has a number of default settings which are normally installed. These settings are designed to reduce the need for user intervention upon installation of the timeswitch. However it is possible to customise the user display by following the procedures in the following pages. The factory default normally installed are illustrated below;
8
Time and Date
Options
Clock Options
Options
Headings
Options
Time and calendar
are factory set
The timeswitch has been
set with the current
time and date during
manufacture.
No alteration should be
required to the time and
date. However, if any
modication is required
please refer to the
owchart on page 9
Time displayed in
24hr clock format
24 hour
or
AM/PM
Channel heading set to
standard installation
i.e. Heating, Hot Water or
None
None
Heating
Water
22:42
Page 9
9
Adjusting Time and Date
The ChannelPlus H11XL Series 2 timeswitch has been set with the current time and date during manufacture. No alteration should be required to the time and date, however if any modication is required please refer to the owchart below.
PLEASE NOTE: Any alteration to the current time or date will cancel any Holiday programme set. It will also cause any Boost or Advance operations to be cancelled.
Press the green
‘SET’ button
Use the ‘+’ and ‘-’
buttons to adjust
‘TIME AND DATE’
Use the ‘+’ and ‘-’
buttons to adjust
THE MONTH
Use the ‘+’ and ‘-’
buttons to adjust
THE YEAR
Use the ‘+’ and ‘-’
buttons to adjust
THE CURRENT TIME
Use the ‘+’ and ‘-’
buttons to select
‘SET DEFAULTS’
Open cover
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press the green
‘SET’ button
Press the green
‘SET’ button
Close cover
Use the ‘+’ and ‘-’
buttons to adjust
THE DAY
SET ON/OFF TIMES
SET HOLIDAY MODE
SET DEFAULTS
SET DEFAULTS
TIME AND DATE
CLOCK OPTIONS
HEADINGS
TIME AND DATE
23.00
30 SEP 2009
SAMPLE DISPLAYS
SET DEFAULTS
TIME AND DATE
23.00
30 SEP 2009
Page 10
10
Adjusting Clock Options
The timeswitch has been preset to display the time in 24 hour clock format, should you prefer AM/PM format then please use
the procedure given in the owchart opposite.
General Information
BATTERY
The timeswitch is tted with a non-rechargeable, non-serviceable long life battery, which will maintain the clock and programmed time settings with the mains supply disconnected.
THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank.
SERVICE AND REPAIR
This timeswitch is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE CHANNELPLUS H11XL section on the right. If this fails to resolve the problem please contact a local heating engineer or a qualied electrician.
Press the green
‘SET’ button
Use the ‘+’ and ‘-’
buttons to adjust
‘CLOCK OPTIONS’
Use the ‘+’ and ‘-’
buttons to adjust
24 HRS OR AM/PM
Use the ‘+’ and ‘-’
buttons to select
‘SET DEFAULTS’
Open cover
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press the green
‘SET’ button
Press the green
‘SET’ button
Close cover
SAMPLE DISPLAYS
SET ON/OFF TIMES
SET HOLIDAY MODE
SET DEFAULTS
SET DEFAULTS
TIME AND DATE
CLOCK OPTIONS
HEADINGS
CLOCK OPTIONS
24 HOURS
AM/PM
SET DEFAULTS
CLOCK OPTIONS
24 HOURS
Page 11
11
Adjusting Channel Headings
The timeswitch has been preset without a channel heading on the display. If you require either the ‘Water’ or ‘Heating’ options then
please follow the owchart opposite.
General Information
RESETTING THE CHANNELPLUS H11XL SERIES 2
Electronic equipment can in some circumstances be affected by electrical interference. If the display becomes frozen or scrambled; or if you wish to revert back to the default settings please use the following procedure:
RESET PROCEDURE
PLEASE NOTE: Using this procedure will restore the ChannelPlus to the original factory programme settings, the time setting will remain correct.
Press the green
‘SET’ button
Use the ‘+’ and ‘-’
buttons to adjust
‘HEADINGS’
Use the ‘+’ and ‘-‘
buttons to adjust
HEATING/WATER
OR NONE
Use the ‘+’ and ‘-’
buttons to select
‘SET DEFAULTS’
Open cover
Press ‘ENTER’
Press ‘ENTER’
Press ‘ENTER’
Press the green
‘SET’ button
Press the green
‘SET’ button
Close cover
ADVANCE
SELECT
BOOST
SAMPLE DISPLAYS
SET DEFAULTS
TIME AND DATE
CLOCK OPTIONS
HEADINGS
HEADINGS
NONE
HEATING
WATER
HEADINGS
WATER
Lower the front ap of the unit. On the right hand Channel press the ADVANCE (Enter) and SELECT (Blue) buttons together, then release and the timeswitch will return to the preset factory settings.
RESET
SET ON/OFF TIMES
SET HOLIDAY MODE
SET DEFAULTS
SET DEFAULTS
Page 12
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
Horstmann Controls Limited, Bristol BS4 1UP
Leaflet number P82719 – Issue 2
... an explantion for householders.
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time; while others allow the domestic hot water and heating to come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types have to be adjusted in Spring and Autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.
The above explanation also applies to your timeswitch, which operates as a single circuit programmer.
12
What is a programmer?
Loading...