Horstmann CentaurPlus C21 2 User Operating Instructions Manual

Page 1
Two Channel Central Heating and Hot Water Programmer
The Horstmann CentaurPlus C21 two channel programmer
gives independent control over hot water and heating
with up to 3 ON/OFF settings per 24 hours.
It also has a 1 hour manual boost button for the hot water and
an advance button for the central heating.
There is also a programming switch allowing permanent selection of:
CentaurPlus C21 Series 2
User Operating Instructions
1
Page 2
2
The CentaurPlus C21 Programmer
The simple instructions contained in this user guide are designed to help with the
programming and operation of the unit.
1 SET indicator - RUN is the normal position 2 Time of day 3 Switch period symbol 4 SET button 5 Hot Water BOOST or adjust (-) button 6 Central Heating ADVANCE or adjust (+) button 7 Hot Water (HW) programme select button or ENTER button 8 Central Heating (CH) programme select button 9 Hot Water ON indicator 10 Central Heating ON indicator 11 SET positions 12 PROGRAMME positions 13 BOOST symbol 14 ADVANCE symbol 15 AM/PM symbol 16 PROGRAMME indicators
1 15
11
3
9
12
4 5 6 7 8
2 16
13
14
10
Page 3
Manual Overrides
BOOST FUNCTION - 1 HOUR TEMPORARY OVERRIDE (HOT WATER ONLY)
The boost facility will allow the user to boost the hot water channel which is currently ‘OFF’ for 1 hour. To indicate the boost being activated BOOST will be shown on the display for the duration of the boost period. The hot water channel ON indicator will also be illuminated.
ADVANCE FUNCTION – BRINGS FORWARD THE NEXT ON OR OFF OPERATION (CENTRAL HEATING ONLY)
The advance facility will allow the user to switch the central heating channel ‘ON’ which is currently ‘OFF’ or switch the central heating channel ‘OFF’ which is currently ‘ON’. To indicate the advance feature being activated ADVANCE will be shown on the display until the next programme switching time. The central heating ON indicator will also be illuminated.
Fully Pumped or Gravity System
The installer will have set the programmer to suit the installed system. This is normally a Fully Pumped system which will allow independent control of the central heating and hot water, however on an old Gravity system the central heating and hot water are linked so that it is not possible to use the central heating independently. This will allow only one common time setting for both hot water and central heating, and will become apparent when setting the ON and OFF times as both will be indicated together.
3
Press BOOST button once for 1 hour of hot water
Press ADVANCE button once to move to the next ON/OFF time
At any time during a BOOST period press BOOST again to return to normal programming
To cancel the advance press the ADVANCE button again. This will return the unit to its normal programme
AUTO ALL DAY 24 HRS OFF
HW CH
AUTO ALL DAY 24 HRS OFF
6:35
6:35
PM
PM
RUN
CLOCK
HW PROG
CH PROG
RUN
CLOCK
HW PROG
CH PROG
BOOST
ADVANCE
HW CH
Page 4
Programme Override Facilities
With the CentaurPlus C21 programmer operating in the normal running mode it is possible to alter the functionality of the programme on each individual channel by means of the CH and HW buttons. The options include;
AUTO - Channel follows all programmed ‘ON’ and ‘OFF’ times.
ALL DAY - Channel operates from 1st ‘ON’ time until 3rd ’OFF’, ignoring all
switching times in between.
24hrs - Channel will be constantly ‘ON’.
OFF - Channel will be constantly ‘OFF’, there is the ability to turn off the
heating during the summer without altering the programme times. On the hot water channel the boost is still available. As both channels are totally independent it is possible to have them set differently if necessary.
All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user.
The diagram below illustrates how to alter the setting, it assumes that the channel is in the AUTO mode to begin with.
Press HW or CH once. Programme goes from AUTO to ALL DAY
Programme will operate from 1st ON until 3rd OFF period
Press HW or CH again. Programme goes from ALL DAY to 24 HRS
Programme will be continuously ON
Press HW or CH again. Programme goes from 24 HRS to OFF
Programme will be continuously OFF
Press HW or CH again. Programme goes from OFF to AUTO
Programme will return to normal ON and OFF times
4
AUTO ALL DAY 24 HRS OFF
6:35
PM
HW CH HW CH HW CH HW CH
AUTO ALL DAY 24 HRS OFF
6:35
PM
AUTO ALL DAY 24 HRS OFF
6:35
PM
AUTO ALL DAY 24 HRS OFF
6:35
PM
Page 5
5
Setting Time of Day and Date
Setting the On and Off Times
To alter these settings please proceed as follows:-
NB. The factory default settings for the 2nd ON/OFF times are both set at 12:00pm (midday) which cancels this ‘ON’ period giving 2 ON/OFF periods for 24hrs. If a midday ‘ON’ period is required set the 2nd ON and OFF times accordingly. If not press ENTER twice.
Once the year is set and the ENTER button is pressed the process is complete and the display will return to the run position
Check that the correct time and day are showing in the display. If the wrong day is showing in the display that would indicate that the date has not been set correctly and the above process should be repeated
Press the set button until the set indicator is next to the ‘clock’ position
Use the + and – buttons to adjust the hour and press ENTER
Use the + and – buttons to adjust the minutes and press ENTER
Use the + and – buttons to set the date and press ENTER
Use the + and – buttons to set the month and press ENTER
Use the + and – buttons to set the year and press ENTER
1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF
6.30AM 8.30AM 12.00PM 12.00PM 4.30PM 10.30PM
DEFAULT TIME SETTINGS
The default time settings shown above are preset at the factory
The CentaurPlus C21 series 2 programmer has a built in clock and calendar. This will mean that you will need to enter the date as well as the time on initial set up or if the factory re-set has been used. Having done this, the clock will automatically adjust for BST/GMT time changes throughout the year.
Press the SET button until SET indicator is next to PROG position
Repeat this process for 2nd and 3rd settings
Use PLUS and MINUS buttons to adjust 1st ON time
Press the SET button until SET indicator is returned to RUN position
Use PLUS and MINUS buttons to adjust 1st OFF time
Press
ENTER
Press
ENTER
6:35
AM
ON
RUN
CLOCK
PROG
1
Page 6
6
Resetting the Programmer
Electronic equipment can in some circumstances be affected by electrical interference. If the programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time settings please reset by pressing the SET and CH buttons together as shown below.
After initial installation it is advisable, before programming the CentaurPlus for the first time, to reset the unit. Resetting can only be achieved with the power ‘ON’ by pressing the SET and CH buttons together. This will return the programmer to the factory set default times.
SET
CH
Press the SET and CH buttons together then release the buttons and the programmer will return to preset factory settings
General Information
BATTERY
The programmer is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank, after 3 days the current time of day will be lost. These measures are to prolong the battery life.
SERVICE AND REPAIR
This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide shown above. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician.
Page 7
7
... an explantion for householders.
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time; while others allow the domestic hot water and heating to come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types have to be adjusted in Spring and Autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.
What is a programmer?
Page 8
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
Horstmann Controls Limited, Bristol BS4 1UP