BX2000
Water Heating Boost Control
This simple boost control is intended for use with electric
water heating systems where the immersion heater(s) are
controlled by the Electricity Company's Radio Teleswitch,
Radio Telemeter or Tariff time switch.
The BX2000 allows the user to 'top up' the hot water if extra
supplies are needed during the day time with the main
water heating taking place overnight using off peak
electricity.
Ÿ Makes the most effective use of the latest cheap-rate
tariff structures, electronically
Ÿ 1 hour or 2 hour boost
Ÿ Always gives priority to off-peak supply
Specification
BX2000
Automatically cancels any boost that has been
Ÿ
selected prior to the off-peak supply becoming
available
Indicator lights show when 'boost' or 'off-peak' are
Ÿ
operational
Incorporates two double pole switches: one for 24
Ÿ
hour supply: one for off-peak (cheap rate) supply
Accepts all incoming and outgoing wiring for single,
Ÿ
dual or two separate 3kW immersion heater
applications
CONTACT RATING 13 Amps 230V AC
Suitable for
immersion heaters up
to 3kW
CONTACT TYPE Disconnection to
immersion heater on
double-pole switch
POWER SUPPLY 230 V 50Hz
POLLUTION DEGREE Degree 2
ENCLOSURE PROTECTION IP30
SHOCK PROTECTION Class 1
LIVE PARTS Enclosed
OPERATING TEMPERATURE 0 °C to 35 °C
RANGE
TIME PERIOD 1 or 2 hours
DIMENSIONS 170 x 115 x 62 mm
BRITISH STANDARDS Designed to meet BS-
EN 60730-2-7
South Bristol Park, Roman Farm Road, Bristol BS4 1UP
t: +44 117 978 8700 | f: +44 117 9788701 | e: sales@horstmann.co.uk | www.horstmann.co.uk
Horstmann is a trading name of Secure Controls (UK) Ltd., a wholly owned subsidiary of Secure Holdings PTE Ltd.
Registered office: Secure House, Moorside Road, Winnall Trading Estate, Winchester, Hampshire, SO23 7RX. Registered in England No. 457553
© January 2013: Secure Controls (UK) Ltd: All rights reserved. The company reserves the right to alter product specifications without notice.
Part No. P81259 Issue 6